Using environment-friendly and low-cost biowaste adsorbents as toxic metal ion removal substrates from aqueous solutions has a great economic advantage. This work evaluated pumpkin and potato peel biowastes for the ad...Using environment-friendly and low-cost biowaste adsorbents as toxic metal ion removal substrates from aqueous solutions has a great economic advantage. This work evaluated pumpkin and potato peel biowastes for the adsorption of cadmium ions. The biowastes were treated with acid or base. Batch experiments were carried out by introducing a known concentration of metal ion solution into the biowaste sorbent at various pH levels. The pH and metal ion concentration was monitored with pH and cadmium ion-selective electrode continuously for two hours, and the final concentration for the metal ion after 24 hours was measured with the cadmium electrode and then confirmed with ICP-OES. L-type isotherms were obtained that fit to Freundlich model. Adsorption isotherms showed chemical adsorption and the kinetics following the second order model. Equilibrium adsorption capacity is higher than 29 mg/g at pH 5.6 when the initial concentration is 220 ppm. Dynamic cadmium adsorption capacity is 17 mg/g from aqueous solution when the feed solution is 220 ppm with pumpkin peel biowaste sorbent. The biowaste materials can be regenerated with acid washing.展开更多
A flexible counter electrode(CE) for dye-sensitized solar cells(DSCs) has been fabricated using a micro-porous polyvinylidene fluoride membrane as support media and sputtered Pt as the catalytic material.Non-conventio...A flexible counter electrode(CE) for dye-sensitized solar cells(DSCs) has been fabricated using a micro-porous polyvinylidene fluoride membrane as support media and sputtered Pt as the catalytic material.Non-conventional structure DSCs have been developed by the fabricated CEs. The Pt metal was sputtered onto one surface of the membrane as the catalytic material. DSCs were assembled by attaching the Ti O2 electrode to the membrane surface without Pt coating. The membrane was with cylindrical pore geometry. It served not only as a substrate for the CE but also as a spacer for the DSC. The fabricated DSC with the flexible membrane CE showed higher photocurrent density than the conventional sandwich devices based on chemically deposited Pt/FTO glass, achieving a photovoltaic conversion efficiency of 4.43%. The results provides useful information in investigation and development of stable, low-cost, simple-design, flexible and lightweight DSCs.展开更多
High energy density lithium-ion batteries using Ni-rich cathode(such as LiNi0.6Co0.2Mn0.2O2) suffer from severe capacity decay.P-toluenesulfonyl fluoride(pTSF) has been investigated as a novel film-forming electrolyte...High energy density lithium-ion batteries using Ni-rich cathode(such as LiNi0.6Co0.2Mn0.2O2) suffer from severe capacity decay.P-toluenesulfonyl fluoride(pTSF) has been investigated as a novel film-forming electrolyte additive to enhance the cycling performances of graphite/LiNi0.6Co0.2Mn0.2O2 pouch cell.In comparison with the baseline electrolyte,a small dose of pTSF can significantly improve the cyclic stability of the cell.Theoretical calculations together with experimental results indicate that pTSF would be oxidized and reduced to construct protective interphase film on the surfaces of LiNi0.6Co0.2Mn0.2O2 cathode and graphite anode,respectively.These S-containing surface films derived from pTSF effectively mitigate the decomposition of electrolyte,reduce the interphasial impedance,as well as prevent the dissolution of transition metal ions from Ni-rich cathode upon cycling at high voltage.This finding is beneficial for the practical application of high energy density graphite/LiNi0.6Co0.2Mn0.2O2 cells.展开更多
A K+-selective electrode and a Na+-selective electrode were used to construct a measuring cell without liquid-junction for the determination of the ion activity ratio of K+ to Na+ in soil suspensions. The measured cel...A K+-selective electrode and a Na+-selective electrode were used to construct a measuring cell without liquid-junction for the determination of the ion activity ratio of K+ to Na+ in soil suspensions. The measured cell potential was not affected by the total electrolyte concentration when the total cation concentration was 10-1-10-3 mol L-1 and the concentration ratio CK+ / CNa+. was 10:1 to 1:50. When the concentration ratios were equal to 1and the total electrolyte concentrations were 10-2 and 10-3 mol L-1, the ion activity ratio measurement would not be affected by pH in the pH range of 3.5 to 11.5 and 4.4 to 11 respectively. Ions other than H+ have no remarkable influence on the measurement. The ion activity ratio of K+ to Na+ measured directly in soil suspension agree well with those in centrifuged supernant solution. The relative deviation was within 4%. From the measured ion activity ratio, the difference of the bonding energies of K+ and Na+ ions was calculated.展开更多
CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted comple...CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted completely at lower temperature. The redox behavior and the crystallization process of the dried gel were studied by thermogravimetric analysis and infrared spectroscopy. The synthesized powders were characterized by X-ray powder diffraction and transmission electron microscopy. In addition, rare earth elements ion-selective electrodes based on acetyl cellulose were prepared using ultra fine cerium oxide powders.展开更多
A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride...A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride. The simulation indicated that the permissible aluminum masked at a certain p H value was limited and hardly related to F-concentration and boric acid. It is better to control p H value below 11.5 and the aluminum concentration within 0.025 mol/L to minimize the interference of hydroxide to the fluoride ISE. The decomposition conditions of boron trifluoride by aluminum chloride were investigated. It is found that the F-detection ratio will approach 1.0 if the Al/F molar ratio is 0.3—0.7 and aluminum concentration is no more than 0.02 mol/L when heated at 80 ℃ for 10 min. In one word, hydroxide is quite fit to mask aluminum for samples which contain high content of fluoride and aluminum and the BF3 content can be successfully determined by this method.展开更多
The thermodynamic and dynamic behaviour of Ni^(2+)|Ni couple in FLINAK melt is investigated by us- ing EMF measurement and micropolarization method.The couple shows the Nernstian reversibility and a large exchange cur...The thermodynamic and dynamic behaviour of Ni^(2+)|Ni couple in FLINAK melt is investigated by us- ing EMF measurement and micropolarization method.The couple shows the Nernstian reversibility and a large exchange current density(6 mA·cm^(-2)).A single crystal LaF_3 which is a fluoride ion conductor used as a membrane of the Ni^(2+)|Ni couple reference electrode is reliable in FLINAK melts at 973 K.The poten- tial of LaF_3 membrane reference electrode is constant within±2 mV.The boron nitride used as a salt bridge was not good in FLINAK melts.The platinum electrode is studied by using micropolarization.The equilibrium potential of Pt electrode is dependent on the absorption and the electrochemical reaction.The potential is stable for a constant composition at constant temperature.展开更多
A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet o...A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.展开更多
Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,alterin...Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,altering the measured potential.Therefore,the characteristics of the effect of other ions on ammonium ion-selective electrode-based urea biosensors are considered.Based on the experimental results,the urea biosensor based on entrapment had a high response voltage of around 189 mV and fast response time of around 16 sec.Moreover,selectivity of the urea biosensor in different interfering ions was considered to elucidate the characteristics of ammonium ion-selective electrode-based biosensors.展开更多
A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coeffic...A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+).展开更多
Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health a...Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.展开更多
Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effe...Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...展开更多
The polyvinylidene fluoride(PVDF)nanofiber web by electrospinning technology has the characteristics of fast response,high sensitivity,wide range of pressure,etc.,and provides new sensitive materials for the sensor te...The polyvinylidene fluoride(PVDF)nanofiber web by electrospinning technology has the characteristics of fast response,high sensitivity,wide range of pressure,etc.,and provides new sensitive materials for the sensor testing the dynamic pressure such as foot pressure during walking.Because of the nanofiber mesh structure,it must be packaged to collect piezoelectric charge and bear strong mechanical behavior before industrial practice.The PVDF nanofiber web is usually packaged by incorporating a pair of flexible electrode as well as the lead of signal output.This present work will introduce the detailed packaging process and technology of PVDF nanofiber web,and three different types of packaging electrode materials(adhesive copper foil tape,indium tin oxide(ITO)thin plate,and adhesive conductive cloth)in previously published literatures are compared by the piezoelectric response of their sensor prototypes to a periodic mechanical activation.The results showed that the surface property of packaging material had a significant effect on the piezoelectric response of sensor by PVDF nanofiber web.For PVDF nanofiber web sensor,therefore,it needed a deep investigation on the specific packaging technology in terms of different working conditions.展开更多
A global optimum location algorithm called Variable Step-Size Generalized Simulated Annealing(VSGSA) was applied to treating the data obtained by using an array of ion-electrodes in solutions containing mixtures of Na...A global optimum location algorithm called Variable Step-Size Generalized Simulated Annealing(VSGSA) was applied to treating the data obtained by using an array of ion-electrodes in solutions containing mixtures of Na+, K+, Ca2+. Unlike traditional optimization algorithms such as simplex procedure, VSGSA can be used to determine the model parameters without any priori information about the analytical system under investigation and overcome the disadvantage of simplex method which might converge to local extrema depending on the starting positions. The algorithm was applied to po-tentiometric determination of ions in mixture solutions.展开更多
The binding mechanism of the interactions of halide ions (F–, Br– and I–) with bovine serum albumin (BSA) and hemoglobin (Hb) were studied at different temperatures, by using ion-selective electrodes. The experimen...The binding mechanism of the interactions of halide ions (F–, Br– and I–) with bovine serum albumin (BSA) and hemoglobin (Hb) were studied at different temperatures, by using ion-selective electrodes. The experimental data were treated according to Klotz equation, and the number of binding sites and the binding constants were determined. The results show that the binding sites of F– on protein molecules are more than those of Br– and I–. Additionally, the number of the binding sites for halide ions on protein molecules increases with increasing temperature. This study also indicates that the binding constants for the interactions of halide ions with proteins gradually decrease as the size of halide ions and temperature increases. These behaviors were reasonably interpreted with the structural and thermodynamic factors. The thermodynamic functions at different temperatures were calculated with thermodynamic equations, and the enthalpy change for the interactions were also determined by isothermal titration calorimetry (ITC) at 298.15 K, which indicate that the interactions of halide ions with proteins are mainly electrostatic interaction.展开更多
The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulf...The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.展开更多
文摘Using environment-friendly and low-cost biowaste adsorbents as toxic metal ion removal substrates from aqueous solutions has a great economic advantage. This work evaluated pumpkin and potato peel biowastes for the adsorption of cadmium ions. The biowastes were treated with acid or base. Batch experiments were carried out by introducing a known concentration of metal ion solution into the biowaste sorbent at various pH levels. The pH and metal ion concentration was monitored with pH and cadmium ion-selective electrode continuously for two hours, and the final concentration for the metal ion after 24 hours was measured with the cadmium electrode and then confirmed with ICP-OES. L-type isotherms were obtained that fit to Freundlich model. Adsorption isotherms showed chemical adsorption and the kinetics following the second order model. Equilibrium adsorption capacity is higher than 29 mg/g at pH 5.6 when the initial concentration is 220 ppm. Dynamic cadmium adsorption capacity is 17 mg/g from aqueous solution when the feed solution is 220 ppm with pumpkin peel biowaste sorbent. The biowaste materials can be regenerated with acid washing.
基金supported by National Natural Science Foundation of China(No.10774046)Shanghai Municipal Science&Technology Committee(No.09JC1404600+1 种基金No.0852nm06100 and No.08230705400)Singapore Ministry of Education innovation fund(MOE IF Funding MOE2008-IF-1-016)
文摘A flexible counter electrode(CE) for dye-sensitized solar cells(DSCs) has been fabricated using a micro-porous polyvinylidene fluoride membrane as support media and sputtered Pt as the catalytic material.Non-conventional structure DSCs have been developed by the fabricated CEs. The Pt metal was sputtered onto one surface of the membrane as the catalytic material. DSCs were assembled by attaching the Ti O2 electrode to the membrane surface without Pt coating. The membrane was with cylindrical pore geometry. It served not only as a substrate for the CE but also as a spacer for the DSC. The fabricated DSC with the flexible membrane CE showed higher photocurrent density than the conventional sandwich devices based on chemically deposited Pt/FTO glass, achieving a photovoltaic conversion efficiency of 4.43%. The results provides useful information in investigation and development of stable, low-cost, simple-design, flexible and lightweight DSCs.
基金supported by the National Natural Science Foundation of China (21573080)the Guangdong Program for Support of Distinguished Young Scholar (2017B030306013)the Science and Technology Planning Project of Guangdong Province (2017B090901020)。
文摘High energy density lithium-ion batteries using Ni-rich cathode(such as LiNi0.6Co0.2Mn0.2O2) suffer from severe capacity decay.P-toluenesulfonyl fluoride(pTSF) has been investigated as a novel film-forming electrolyte additive to enhance the cycling performances of graphite/LiNi0.6Co0.2Mn0.2O2 pouch cell.In comparison with the baseline electrolyte,a small dose of pTSF can significantly improve the cyclic stability of the cell.Theoretical calculations together with experimental results indicate that pTSF would be oxidized and reduced to construct protective interphase film on the surfaces of LiNi0.6Co0.2Mn0.2O2 cathode and graphite anode,respectively.These S-containing surface films derived from pTSF effectively mitigate the decomposition of electrolyte,reduce the interphasial impedance,as well as prevent the dissolution of transition metal ions from Ni-rich cathode upon cycling at high voltage.This finding is beneficial for the practical application of high energy density graphite/LiNi0.6Co0.2Mn0.2O2 cells.
文摘A K+-selective electrode and a Na+-selective electrode were used to construct a measuring cell without liquid-junction for the determination of the ion activity ratio of K+ to Na+ in soil suspensions. The measured cell potential was not affected by the total electrolyte concentration when the total cation concentration was 10-1-10-3 mol L-1 and the concentration ratio CK+ / CNa+. was 10:1 to 1:50. When the concentration ratios were equal to 1and the total electrolyte concentrations were 10-2 and 10-3 mol L-1, the ion activity ratio measurement would not be affected by pH in the pH range of 3.5 to 11.5 and 4.4 to 11 respectively. Ions other than H+ have no remarkable influence on the measurement. The ion activity ratio of K+ to Na+ measured directly in soil suspension agree well with those in centrifuged supernant solution. The relative deviation was within 4%. From the measured ion activity ratio, the difference of the bonding energies of K+ and Na+ ions was calculated.
基金The work was financially supported by the Project KJCXGC-O1 of Northwest Normal University, Lanzhou and theExcellent Young Te
文摘CeO2 nanoparticles with an average diameter of about 30 nm were prepared by sol-gel method at lower temperature. The gel, transformed from the aqueous solution of metal nitrate and citric acid, can be combusted completely at lower temperature. The redox behavior and the crystallization process of the dried gel were studied by thermogravimetric analysis and infrared spectroscopy. The synthesized powders were characterized by X-ray powder diffraction and transmission electron microscopy. In addition, rare earth elements ion-selective electrodes based on acetyl cellulose were prepared using ultra fine cerium oxide powders.
基金Supported by the Independent Innovation Fund of Tianjin University(No.1307)
文摘A method was proposed to determine boron trifluoride in boron trifluoride complex using fluoride ion selective electrode(ISE). Hydroxide was chosen to mask aluminum for the determination of 0.01—0.1 mol/L of fluoride. The simulation indicated that the permissible aluminum masked at a certain p H value was limited and hardly related to F-concentration and boric acid. It is better to control p H value below 11.5 and the aluminum concentration within 0.025 mol/L to minimize the interference of hydroxide to the fluoride ISE. The decomposition conditions of boron trifluoride by aluminum chloride were investigated. It is found that the F-detection ratio will approach 1.0 if the Al/F molar ratio is 0.3—0.7 and aluminum concentration is no more than 0.02 mol/L when heated at 80 ℃ for 10 min. In one word, hydroxide is quite fit to mask aluminum for samples which contain high content of fluoride and aluminum and the BF3 content can be successfully determined by this method.
文摘The thermodynamic and dynamic behaviour of Ni^(2+)|Ni couple in FLINAK melt is investigated by us- ing EMF measurement and micropolarization method.The couple shows the Nernstian reversibility and a large exchange current density(6 mA·cm^(-2)).A single crystal LaF_3 which is a fluoride ion conductor used as a membrane of the Ni^(2+)|Ni couple reference electrode is reliable in FLINAK melts at 973 K.The poten- tial of LaF_3 membrane reference electrode is constant within±2 mV.The boron nitride used as a salt bridge was not good in FLINAK melts.The platinum electrode is studied by using micropolarization.The equilibrium potential of Pt electrode is dependent on the absorption and the electrochemical reaction.The potential is stable for a constant composition at constant temperature.
文摘A PVC membrane enoxacin ion-selective electrode based on a needle-shaped inner reference electrode was prepared. A Ag/AgCl wire was used as the substrate of this electrode. It was previously coated with a thin sheet of urea-formaldehyde resin containing Cl - ions to form a needle-shaped inner reference electrode, then the inner reference electrode was coated with a thin sheet of a PVC membrane containing an enoxacin tetraphenylborate ion-pair complex. The influences of various ion-pair complexes, concentrations of the active components in the membrane and the plasticizers on the performance of the electrode were studied by orthogonal design. The linear response range of the electrode was 7.9×10 -5 -1.0×10 -2 mol/L. The detection limit was 2.0×10 -5 mol/L. The slope was 30.4 mV/decade(25 ℃). The electrode can be used for the potentiometric determination of enoxacin tablets directly. The average recovery was 100.4%, and the RSD was 0.9%. The results agreed with those determined by the method in Chinese Pharmacopoeia.
文摘Enzyme was immobilized on an ammonium ion-selective electrode by different methods.An ion-selective electrode is not completely ion-specific,and interfering ions react with the ion-selective electrode membrane,altering the measured potential.Therefore,the characteristics of the effect of other ions on ammonium ion-selective electrode-based urea biosensors are considered.Based on the experimental results,the urea biosensor based on entrapment had a high response voltage of around 189 mV and fast response time of around 16 sec.Moreover,selectivity of the urea biosensor in different interfering ions was considered to elucidate the characteristics of ammonium ion-selective electrode-based biosensors.
文摘A calcium ion-setective eletrode based on a new neutral carrier was studied.The electrode gives a Nernstian response in the rang 5.9-1 Pa and the response is stable in a wide pH range.Logarithms of setectivity coefficents are -2.3 Li(+),-3.5 Na(+),-4.0 K(+),-3.7NH_4(+),-4.5 Mg(2+) and -4.4Zn(2+).
文摘Fluoride is widespread in the environment, water, air, vegetation and Earth’s crust which can entre ground and surface water by natural process. Fluoride in minute quantities is essential component for human health and help in normal mineralization of bone and formation of dental enamel. The determination of fluoride in some species was performed by using fluoride ion-selective electrode by direct measurement and standard addition method. The concentration of fluoride ion was determined in drinking water (from different place at Kathmandu), toothpaste, various brand of tea and coffees. The range of fluoride concentration in water sample was 0.16 to 0.39 mg/l, tea and coffee samples were 0.011 to 0.084 mg/l and its value of toothpaste was 0.026 to 0.75 mg/l. The concentration of fluoride ion obtain from different sample was compared with the legitimate value given by the world health organization.
基金supported by the Chinese Academy of Sciences(No.KZCX2-YW-410)the National Natural Science Foundation of China(No.40776058)+1 种基金the National 863 High Technology Project of the Ministry of Science and Technology of China(No.2007AA09Z103)the Outstanding Youth Natural Science Foundation of Shandong Province(No.JQ200814)
文摘Four 20-membered N_2S_4-monoazathiacrown ethers have been synthesized and explored as neutral ionophores for Ag^+-selective electrodes.Potentiometric responses reveal that the flexibility of the ligands has great effect on the selectivity and sensitivity to Ag^+ ions.The electrode based on ionophore 9,10,20,25-tetrahydro-5H,12H-tribenzo[b,n,r][1,7,10,16,4,13]tetrathiadiaza cycloicosine 6,13-(7H,14H)-dione(C) with 2-nitrophenyl octyl ether(o-NPOE) as solvent in a poly(vinyl chloride)(PVC) membrane matrix sho...
基金“111 Project”Biomedical Textile Materials Science and Technology,China(No.B07024)National Natural Science Foundation of China(No.51405079)+2 种基金China Postdoctoral Science Foundation(No.2015M570307)the Fundamental Research Funds for the Central Universities,Chinathe Jiangsu Planned Projects for Postdoctoral Research Funds,China
文摘The polyvinylidene fluoride(PVDF)nanofiber web by electrospinning technology has the characteristics of fast response,high sensitivity,wide range of pressure,etc.,and provides new sensitive materials for the sensor testing the dynamic pressure such as foot pressure during walking.Because of the nanofiber mesh structure,it must be packaged to collect piezoelectric charge and bear strong mechanical behavior before industrial practice.The PVDF nanofiber web is usually packaged by incorporating a pair of flexible electrode as well as the lead of signal output.This present work will introduce the detailed packaging process and technology of PVDF nanofiber web,and three different types of packaging electrode materials(adhesive copper foil tape,indium tin oxide(ITO)thin plate,and adhesive conductive cloth)in previously published literatures are compared by the piezoelectric response of their sensor prototypes to a periodic mechanical activation.The results showed that the surface property of packaging material had a significant effect on the piezoelectric response of sensor by PVDF nanofiber web.For PVDF nanofiber web sensor,therefore,it needed a deep investigation on the specific packaging technology in terms of different working conditions.
基金Supported by the National Natural Science Foundation of China Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Academia Sinica
文摘A global optimum location algorithm called Variable Step-Size Generalized Simulated Annealing(VSGSA) was applied to treating the data obtained by using an array of ion-electrodes in solutions containing mixtures of Na+, K+, Ca2+. Unlike traditional optimization algorithms such as simplex procedure, VSGSA can be used to determine the model parameters without any priori information about the analytical system under investigation and overcome the disadvantage of simplex method which might converge to local extrema depending on the starting positions. The algorithm was applied to po-tentiometric determination of ions in mixture solutions.
文摘The binding mechanism of the interactions of halide ions (F–, Br– and I–) with bovine serum albumin (BSA) and hemoglobin (Hb) were studied at different temperatures, by using ion-selective electrodes. The experimental data were treated according to Klotz equation, and the number of binding sites and the binding constants were determined. The results show that the binding sites of F– on protein molecules are more than those of Br– and I–. Additionally, the number of the binding sites for halide ions on protein molecules increases with increasing temperature. This study also indicates that the binding constants for the interactions of halide ions with proteins gradually decrease as the size of halide ions and temperature increases. These behaviors were reasonably interpreted with the structural and thermodynamic factors. The thermodynamic functions at different temperatures were calculated with thermodynamic equations, and the enthalpy change for the interactions were also determined by isothermal titration calorimetry (ITC) at 298.15 K, which indicate that the interactions of halide ions with proteins are mainly electrostatic interaction.
基金We are grateful to the National Natural Science Foundation of China(22172040,21974031 and 22204026)the Project Funded by China Postdoctoral Science Foundation(2022M710859)+2 种基金the Department of Science and Techniques of Guangdong Province(2021A1515010180,2019B010933001)Guangzhou Municipal Science and Technology Bureau(202102010449)the Department of Guangdong Provincial Public Security(GZQC20-PZ11-FD084)fortheirfinancial support of thiswork.
文摘The analytical performance of H+-selective solid-contact ion-selective electrodes(SCISEs)based on solid contact polyaniline doped with chloride(PANI(Cl))and poly(3,4-ethylenedioxythiophene)doped with poly(styrene sulfonate)(PEDOT(PSS))was characterized by a developed coulometric signal transduction method.PEDOT(PSS)solid contact is covered by PVC based H+-selective membrane.The obtained coulometric signal demonstrates that the cumulated charge can be amplified by increasing the capacitance of solid contact.SCISEs covered with spin-coated membrane behave faster amperometric response than electrodes with drop-cast mem-brane.In contrast to earlier works,the amperometric response and impedance spectrum demonstrates H+transfer through SCISEs is independent from the thickness of membrane.The exceptional behavior of PANI(Cl)H+-SCISEs shows that the capacitance estimated from impedance spectrum at low frequency 10 mHz and coulometric signal of PANI(Cl)based SCISEs is influenced by the applied po-tentials,whereas PEDOT(PSS)solid contact is independent from the chosen applied potentials.Furthermore,preliminary investiga-tions of coulometric signal transduction on flexible pH sensor implies its potential applications in wearable sensors for sweat ion concentration detection.