Development of a wide-range and fast-response digitizing pulse signal acquisition and processing system for neutron flux monitoring on EAST 被引量:2
1
作者 Li Yang Hong-Rui Cao +7 位作者 Jin-Long Zhao Zi-Han Zhang Qiang Li Guo-Bin Wu Yong-Qiang Zhang Guo-Qiang Zhong Li-Qun Hu Zi-Jun Zhang 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2022年第3期126-136,共11页
The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result... The neutron count rate fluctuation reaches six orders of magnitude between the ohmic plasma scenario and high power of auxiliary heating on an experimental advanced superconducting tokamak(EAST).The measurement result of neutron flux monitoring(NFM)is a significant feedback parameter related to the acquisition of radiation protection-related information and rapid fluctuations in neutron emission induced by plasma magnetohydrodynamic activity.Therefore,a wide range and high time resolution are required for the NFM system on EAST.To satisfy these requirements,a digital pulse signal acquisition and processing system with a wide dynamic range and fast response time was developed.The present study was conducted using a field-programmable gate array(FPGA)and peripheral component interconnect extension for instrument express(PXIe)platform.The digital dual measurement modes,which are composed of the pulse-counting mode and AC coupled square integral's Campbelling mode,were designed to expand the measurement range of the signal acquisition and processing system.The time resolution of the signal acquisition and processing system was improved from 10 to 1 ms owing to utilizing highspeed analog-to-digital converters(ADCs),a high-speed PXIe communication with a direct memory access(DMA)mode,and online data preprocessing technology of FPGA.The signal acquisition and processing system was tested experimentally in the EAST radiation field.The test results showed that the time resolution of NFM was improved to 1 ms,and the dynamic range of the neutron counts rate was expanded to more than 10^(6) counts per second.The Campbelling mode was calibrated using a multipoint average linear fitting method;subsequently,the fitting coefficient reached 0.9911.Therefore,the newly developed pulse signal acquisition and processing system ensures that the NFM system meets the requirements of high-parameter experiments conducted on EAST more effectively. 展开更多
关键词 EAST Neutron flux monitoring High time resolution Wide range Pulse signal acquisition and processing system
下载PDF
High-precision and wide-range real-time neutron flux monitor system through multipoint linear calibration 被引量:4
2
作者 Ren-Jie Zhu Xiang Zhou +9 位作者 Zi-Hao Liu Wen-Di Wang Xiao-Li Mou Teng-Fei Fang Qing-Li Ma Xiu-Feng Xu Guo-Liang Yuan Li Zhao Ling-Feng Wei Ze-Jie Yin 《Nuclear Science and Techniques》 SCIE CAS CSCD 2020年第9期98-106,共9页
The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test rea... The neutron flux monitor(NFM)system is an important diagnostic subsystem introduced by large nuclear fusion devices such as international thermonuclear experimental reactor(ITER),Japan torus-60,tokamak fusion test reactor,and HL-2 A.Neutron fluxes can provide real-time parameters for nuclear fusion,including neutron source intensity and fusion power.Corresponding to different nuclear reaction periods,neutron fluxes span over seven decades,thereby requiring electronic devices to operate in counting and Campbelling modes simultaneously.Therefore,it is crucial to design a real-time NFM system to encompass such a wide dynamic range.In this study,a high-precision NFM system with a wide measurement range of neutron flux is implemented using realtime multipoint linear calibration.It can automatically switch between counting and Campbelling modes with variations in the neutron flux.We established a testing platform to verify the feasibility of the NFM system,which can output the simulated neutron signal using an arbitrary waveform generator.Meanwhile,the accurate calibration interval of the Campbelling mode is defined well.Based on the above-mentioned design,the system satisfies the requirements,offering a dynamic range of 10~8 cps,temporal resolution of 1 ms,and maximal relative error of 4%measured at the signal-to-noise ratio of 15.8 dB.Additionally,the NFM system is verified in a field experiment involving HL-2 A,and the measured neutron flux is consistent with the results. 展开更多
关键词 Multipoint linear calibration Real time Simulated neutron signal Neutron flux monitoring ITER HL-2A
下载PDF
Development of a data acquisition and control system for the International Thermonuclear Experimental Reactor neutron flux monitor 被引量:2
3
作者 Zihao LIU Xiang ZHOU +3 位作者 Renjie ZHU Li ZHAO Lingfeng WEI Zejie YIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2020年第1期96-103,共8页
To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber de... To satisfy high-precision,widc-rangc,and real-time neutron flux measurement requirements by the International Thermonuclear Experimental Reactor(ITF.R),a data acquisition and control system based on fission chamber detectors and fast controller technology,has been developed for neutron flux monitor in ITER Equatorial Port#7.The signal processing units which arc based on a field programmable gate array and the PXI Express platform arc designed to realize the neutron flux measurement with I ms time resolution and a fast response less than 0.2 ms,together with real-time timestamps provided by a timing hoard.The application of the wide-range algorithm allows the system to measure up to 10^10cps with a relative error of less than 5%.Furthermore,the system is managed and controlled by a software based on the Experimental Physics and Industrial Control System,compliant with COntrol.Data Access and Communication architecture. 展开更多
关键词 neutron flux monitor data acquisition.CODAC F.PICS
下载PDF
Development of Prototype Neutron Flux Monitor for ITER 被引量:1
4
作者 Yang Jinwei Song Xianying +6 位作者 Zhang Wei Li Xu Lee Wenzhong Wang Shiqing Xiao Gongshan Yang Bo Lu Shuangtong 《Plasma Science and Technology》 SCIE EI CAS CSCD 2005年第3期2860-2862,共3页
The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detec... The prototype neutron flux monitor consists of a high purity ^(235)U fission chamber detector and a'blank'detector,which is a fissile material free detector with the same dimension as the fission chamber detector to identify noise issues such as noise coming from gamma rays.The main parameters of the fission chamber assembly that have been measured in the laboratory are confirmed to approach the technological level of the International Thermonuclear Experimental Reactor(ITER)in the near future.This prototype neutron flux monitor will be further developed to become a neutron flux monitor suitable for the operation phase of D-D fusion on the ITER. 展开更多
关键词 neutron flux monitor fission chamber detector international thermonuclear experimental reactor(ITER) plateau characteristic curve discrimination threshold
下载PDF
Fusion Neutron Flux Monitor for ITER 被引量:1
5
作者 杨进蔚 杨青巍 +3 位作者 肖功珊 张炜 宋先瑛 李旭 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第2期141-147,共7页
Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. T... Neutron flux monitor (NFM) as an important diagnostic sub-system in ITER (international thermonuclear experimental reactor) provides a global neutron source intensity, fusion power and neutron flux in real time. Three types of neutron flux monitor assemblies with different sensitivities and shielding materials have been designed. Through MCNP (Mante-Carlo neutral particle transport code) calculations, this extended system of NFM can detect the neutron flux in a range of 10^4 n/(cm^2.s) to 10^14 n/(cm^2.s). It is capable of providing accurate neutron yield measurements for all operational modes encountered in the ITER experiments including the in-situ calibration. Combining both the counting mode and Campbelling (MSV; Mean Square Voltage) mode in the signal processing units, the requirement of the dynamic range (107) for these NFMs and time resolution (1 ms) can be met. Based on a uncertainty analysis, the estimated absolute measurement accuracies of the total fusion neutron yield can reach the required 10% level in both the early stage of the DD-phase and the DD-phase, the absolute measurement accuracy full power DT operation mode. In the advanced would be better than 20%. 展开更多
关键词 neutron flux monitor international thermonuclear experimental reactor(ITER) assembly of fission chamber
下载PDF
In-situ Calibration Techniques and Preliminary Assessment of Accuracy for NFM on ITER
6
作者 杨进蔚 杨青巍 袁国良 《Plasma Science and Technology》 SCIE EI CAS CSCD 2008年第6期676-680,共5页
Absolutely calibrated measurements of the neutron yields which need to cover both D-D and D-T phase of the international thermal-nuclear experimental reactor (ITER) are important for the evaluation of fusion power a... Absolutely calibrated measurements of the neutron yields which need to cover both D-D and D-T phase of the international thermal-nuclear experimental reactor (ITER) are important for the evaluation of fusion power and fusion gain Q in D-D and D-T operations. This paper describes the in-situ calibration techniques and methods, the neutron sources including ^252Cf and neutron generator for calibration, the preliminary accuracy assessment and the error analyses. In addition, some difficult problems regarding the in situ calibration for the neutron flux monitor (NFM) on ITER are presented and discussed. 展开更多
关键词 in situ calibration neutron flux monitor neutron generator (NG)