Soft-switching Grid-connected PV Inverter With Interleaved Flyback Topology 被引量:15
1
作者 古俊银 吴红飞 +1 位作者 陈国呈 邢岩 《中国电机工程学报》 EI CSCD 北大核心 2011年第36期I0005-I0005,共1页
提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断... 提出一种应用于单个光伏组件的软开关交错反激并网逆变器拓扑及其软开关控制策略。针对反激变压器漏感问题,提出漏感能量吸收回馈电路,实现了漏感能量吸收再利用,并实现了开关管漏源电压的钳位,提高了变换效率同时降低了开关管关断电压尖峰;提出基于数字处理器的反激变换器变开关频率谐振软开关控制策略,实现了开关管的零电压开通,同时改善了逆变器的电磁兼容特性;提出的交错并联反激逆变器有助于减小变压器和滤波器的体积,提高功率密度。详细分析变换器的工作原理,分析变开关频率谐振软开关控制方式的原理和实现条件,最后进行实验验证。 展开更多
关键词 拓扑结构 反激式 逆变器 软交换网 光伏 交错 软交换技术 低成本
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
2
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
3
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
4
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
5
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE grid-connected inverter DECOUPLING Control
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
6
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(LCL)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
7
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 Photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
8
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy Photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
基于伏秒的反激式光伏微逆变器的仿真研究
9
作者 牛萌萌 杨昊 《哈尔滨师范大学自然科学学报》 CAS 2024年第1期74-80,共7页
针对传统反激式光伏微逆变器因2倍频电压纹波引起的进网电流畸变的问题,提出了1种用于励磁电感电流断续模式下反激式光伏微逆变器的基于伏秒的控制方法.根据谐波抑制策略,对反激式光伏微逆变器进行小信号建模,利用扫频验证建模的正确性... 针对传统反激式光伏微逆变器因2倍频电压纹波引起的进网电流畸变的问题,提出了1种用于励磁电感电流断续模式下反激式光伏微逆变器的基于伏秒的控制方法.根据谐波抑制策略,对反激式光伏微逆变器进行小信号建模,利用扫频验证建模的正确性.通过推导变压器参数的设计准则,结合变压器参数与输入电压调节范围和损耗的关系对其进行优化设计并进行仿真.结果证明了所提控制方法的准确性,与传统开闭环电流控制方法相比,输出电流的THD更低,达3.783%. 展开更多
关键词 反激式光伏微逆变器 电流畸变 优化设计 仿真
下载PDF
一种带功率解耦的Flyback微型逆变器研究 被引量:7
10
作者 王晓 张立伟 +1 位作者 李艳 游小杰 《电工电能新技术》 CSCD 北大核心 2015年第2期44-49,共6页
单相光伏并网逆变器中由于输入输出瞬时功率存在差异,通常需要并联很大的电解电容来平衡这部分功率,由于电解电容寿命短,严重限制了逆变器的寿命,所以在电路中加入功率解耦单元,用长寿命的薄膜电容代替电解电容。本文研究一种带功率解耦... 单相光伏并网逆变器中由于输入输出瞬时功率存在差异,通常需要并联很大的电解电容来平衡这部分功率,由于电解电容寿命短,严重限制了逆变器的寿命,所以在电路中加入功率解耦单元,用长寿命的薄膜电容代替电解电容。本文研究一种带功率解耦的Flyback微型逆变器,并对其进行参数计算和损耗分析,推导出了通用的计算公式,最后通过仿真和实验验证了该拓扑的可行性。 展开更多
关键词 flyback微型逆变器 光伏发电 功率解耦 损耗分析
下载PDF
Generalized coupling resonance modeling, analysis, and active damping of multi-parallel inverters in microgrid operating in grid-connected mode 被引量:14
11
作者 Zhiyong CHEN Yandong CHEN +4 位作者 Josep M.GUERRERO Huimin KUANG Yuan HUANG Leming ZHOU An LUO 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2016年第1期63-75,共13页
This paper firstly presents an equivalent coupling circuit modeling of multi-parallel inverters in microgrid operating in grid-connected mode. By using the model, the coupling resonance phenomena are explicitly invest... This paper firstly presents an equivalent coupling circuit modeling of multi-parallel inverters in microgrid operating in grid-connected mode. By using the model, the coupling resonance phenomena are explicitly investigated through the mathematical approach, and the intrinsic and extrinsic resonances exist widely in microgrid.Considering the inverter own reference current, other inverters reference current, and grid harmonic voltage, the distributions of resonance peaks with the growth in the number of inverters are obtained. Then, an active damping control parameter design method is proposed to attenuate coupling resonance, and the most salient feature is that the optimal range of the damping parameter can be easily located through an initiatively graphic method. Finally,simulations and experiments verify the validity of the proposed modeling and method. 展开更多
关键词 MICROGRID grid-connected mode Multi-parallel inverters Active damping Coupling resonance
原文传递
Impedance Modeling and Stability Analysis of PV Grid-connected Inverter Systems Considering Frequency Coupling 被引量:10
12
作者 Shaojian Song Ze Wei +2 位作者 Yuzhang Lin Bin Liu Hui Liu 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期279-290,共12页
Impedance analysis is an effective method to analyze the oscillation issue associated with grid-connected photovoltaic systems.However,the existing impedance modeling of a gridconnected photovoltaic inverter usually o... Impedance analysis is an effective method to analyze the oscillation issue associated with grid-connected photovoltaic systems.However,the existing impedance modeling of a gridconnected photovoltaic inverter usually only considers the effect of a single perturbation frequency,ignoring the coupling frequency response between the internal control loops of a grid-connected inverter,which severely affects the accuracy of the stability analysis.Hence,a method of impedance modeling and stability analysis for grid-connected photovoltaic inverters considering cross-coupling frequency is proposed in this paper.First,the generation mechanism of frequency coupling in gridconnected photovoltaic inverters,and the relationship between the coupling frequency and perturbation frequency are analyzed.Secondly,a sequence impedance model of grid-connected photovoltaic systems considering the coupling frequency is established by using the harmonic linearization method.The impact of DC bus voltage control strategy on frequency coupling characteristics of a grid-connected photovoltaic system is evaluated,and the impact of a coupling frequency term on system stability is quantitatively analyzed.Finally,the advantages of the proposed method are verified by several simulations.The results show that the proposed impedance model can accurately predict the potential resonance points of the system,and the coupling frequency characteristics will become much stronger with smaller DC bus capacitance or larger bandwidth of the DC bus controller. 展开更多
关键词 DC bus voltage control frequency coupling grid-connected photovoltaic inverter system(PVs) harmonic linearization sub-synchronous oscillation
原文传递
Impact of phase-locked loop on stability of active damped LCL-filter-based grid-connected inverters with capacitor voltage feedback 被引量:6
13
作者 Xiaoqiang GUO Shichao LIU Xiaoyu WANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期574-583,共10页
Active damped LCL-filter-based inverters have been widely used for grid-connected distributed generation(DG) systems. In weak grids, however, the phase-locked loop(PLL) dynamics may detrimentally affect the stability ... Active damped LCL-filter-based inverters have been widely used for grid-connected distributed generation(DG) systems. In weak grids, however, the phase-locked loop(PLL) dynamics may detrimentally affect the stability of grid-connected inverters due to interaction between the PLL and the controller. In order to solve the problem, the impact of PLL dynamics on small-signal stability is investigated for the active damped LCL-filtered grid-connected inverters with capacitor voltage feedback. The system closed-loop transfer function is established based on the Norton equivalent model by taking the PLL dynamics into account. Using an established model, the system stability boundary is identified from the viewpoint of PLL bandwidth and current regulator gain. The accuracy of the ranges of stability for the PLL bandwidth and current regulator gain is verified by both simulation and experimental results. 展开更多
关键词 Phase-locked loop Small-signal stability grid-connected inverter Active damping LCL filter Transfer function
原文传递
Stability of LCL-filtered grid-connected inverters with capacitor current feedback active damping considering controller time delays 被引量:4
14
作者 Wei XIA Jinsong KANG 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2017年第4期584-598,共15页
This paper investigates the stability of LCL-filtered grid-connected inverters with capacitor current feedback(CCF) active damping. The impact of time delays in the digital controller on active damping and its equival... This paper investigates the stability of LCL-filtered grid-connected inverters with capacitor current feedback(CCF) active damping. The impact of time delays in the digital controller on active damping and its equivalent virtual impedance is analyzed. The inherent relationship between these time delays and stability is illustrated.Specially, a critical value of the CCF active damping coefficient kdamp_cis proposed to define three distinct regions of stability evaluation. If kdamp_c[ 0, a sufficient but smaller damping coefficient(kdamp\ kdamp_c) is recommended as optimum damping solution;if kdamp_c= 0,system will be unstable irrespective of active damping;and if kdamp_c\ 0, active damping is not necessary to design a stable system. Necessary conditions to ensure stability are identified;guidelines for controller design are then presented to optimize the performance of active damping and dynamic response. Simulation and experimental results confirm the presented analysis. 展开更多
关键词 LCL filter grid-connected inverter Controller time delays STABILITY
原文传递
LCL-resonance damping strategies for grid-connected inverters with LCL filters: a comprehensive review 被引量:6
15
作者 Jinming XU Shaojun XIE 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第2期292-305,共14页
Grid-connected LCL-filtered inverters are commonly used for distributed power generators. The LCL resonance should be treated properly. Recently, many strategies have been used to damp the resonance, but the relations... Grid-connected LCL-filtered inverters are commonly used for distributed power generators. The LCL resonance should be treated properly. Recently, many strategies have been used to damp the resonance, but the relationships between different damping strategies have not been thoroughly investigated. Thus, this study analyses the essential mechanisms of LCL-resonance damping and reviews state-of-the-art resonance damping strategies.Existing resonance damping strategies are classified into those with single-state and multi-state feedback. Singlestate feedback strategies damp the LCL resonance using feedback of a voltage or current state at the resonance frequency. Multi-state feedback strategies are summarized as zero-placement and pole-placement strategies, where the zero-placement strategy configures the zeros of a novel state combined by multi-state feedback, while the poleplacement strategy aims to assign the closed-loop poles freely. Based on these mechanisms, an investigation of single-state and multi-state feedback is presented, including detailed comparisons of the existing strategies. Finally,some future research directions that can improve LCL-filtered inverter performance and minimize their implementation costs are summarized. 展开更多
关键词 LCL filter grid-connected inverter RESONANCE DAMPING State feedback Investigation
原文传递
The Resonance Suppression for Parallel Photovoltaic Grid-connected Inverters in Weak Grid 被引量:6
16
作者 Qiu-Xia Yang Kun Li +1 位作者 Cui-Mei Zhao Hu Wang 《International Journal of Automation and computing》 EI CSCD 2018年第6期716-727,共12页
Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation o... Obvious resonance peak will be generated when parallel photovoltaic grid-connected inverters are connected to the weak grid with high grid impedance, which seriously affects the stability of grid-connected operation of the photovoltaic system. To overcome the problems mentioned above, the mathematical model of the parallel photovoltaic inverters is established. Several factors including the impact of the reference current of the grid-connected inverter, the grid voltage interference and the current disturbance between the photovoltaic inverters in parallel with the grid-connected inverters are analyzed. The grid impedance and the LCL filter of the photovoltaic inverter system are found to be the key elements which lead to existence of resonance peak. This paper presents the branch voltage and current double feedback suppression method under the premise of not changing the topological structure of the photovoltaic inverter, which effectively handles the resonance peak, weakens the harmonic content of the grid current of the photovoltaic grid-connected inverter and the voltage at the point of common coupling, and improves the stability of the parallel operation of the photovoltaic grid-connected inverters in weak grid. At last, the simulation model is established to verify the reliability of this suppression method. 展开更多
关键词 Parallel photovoltaic grid-connected inverters weak grid grid impedance resonance peak branch voltage and current double feedback.
原文传递
Highly efficient three-phase grid-connected parallel inverter system 被引量:3
17
作者 Evren ISEN Ahmet Faruk BAKAN 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第5期1079-1089,共11页
In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the gr... In this paper, a new three-phase grid-connected inverter system is proposed. The proposed system includes two inverters. The main inverter, which operates at a low switching frequency, transfers active power to the grid. The auxiliary inverter processes a very low power to compensate for the grid current ripple. Thus, no active power is processed by the auxiliary inverter. The goal is to produce a grid current with a low total harmonic distortion(THD) and to obtain the highest efficiency from the inverter system. The main inverter is controlled via a space-vector pulse-width modulation owing to its optimum switching pattern, and the auxiliary inverter is controlled via a hysteresis current-control technique owing to the technique's fast dynamic response. The proposed system is analyzed in terms of different DC-link voltage, switching frequency,and filter inductance values. The optimum system parameters are selected that provide a THD value of less than 5%.A prototype inverter system at a 10 kW output power has been implemented. The main inverter operates at a 3 kHz switching frequency, and the auxiliary inverter compensates for the grid-current ripple. In total, a THD of 4.33%and an efficiency of 97.86% are obtained using the proposed inverter system prototype. 展开更多
关键词 Active filter inverter efficiency RIPPLE CANCELLATION THREE-PHASE grid-connected inverter
原文传递
Small-signal Multi-frequency Model for Grid-connected Inverter System with PWM Effect 被引量:2
18
作者 Guocheng San Wenlin Zhang +4 位作者 Ran Luo Xiaoqiang Guo Huanhai Xin Elisabetta Tedeschi Mariusz Malinowski 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2020年第2期307-317,共11页
It is a well known fact that pulse width modulation(PWM)produces sideband effects.Taking this point into account,the accuracy of the grid-connected inverter model can be improved.In this paper,considering the aliasing... It is a well known fact that pulse width modulation(PWM)produces sideband effects.Taking this point into account,the accuracy of the grid-connected inverter model can be improved.In this paper,considering the aliasing effect of the PWM sideband components on the closed-loop control,a complete representation for the transfer function of the PWM is obtained.Furthermore,a multi-frequency model of grid-connected inverter system is derived.It is convenient for obtaining a PWM gain for grid-connected inverter system,which is PWM-controlled.In order to have an easy physical expression of the effects caused by the sideband components,an approximation is applied to simplify the PWM gain.The stability analysis is used to prove that PWM gain considering PWM effect is more precise than the conventional one.Experimental results verify the effectiveness of our proposal. 展开更多
关键词 grid-connected inverter multi-frequency model pulse width modulation stability analysis
原文传递
Improved three-vector based dead-beat model predictive direct power control strategy for grid-connected inverters
19
作者 Chen-wen CHENG Heng NIAN Long-qi LI 《Frontiers of Information Technology & Electronic Engineering》 SCIE EI CSCD 2018年第11期1420-1431,共12页
Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. ... Since only one inverter voltage vector is applied during each duty cycle, traditional model predictive direct power control(MPDPC) for grid-connected inverters(GCIs) results in serious harmonics in current and power. Moreover, a high sampling frequency is needed to ensure satisfactory steady-state performance, which is contradictory to its long execution time due to the iterative prediction calculations. To solve these problems, a novel dead-beat MPDPC strategy is proposed, using two active inverter voltage vectors and one zero inverter voltage vector during each duty cycle. Adoption of three inverter vectors ensures a constant switching frequency. Thus, smooth steady-state performance of both current and power can be obtained. Unlike the traditional three-vector based MPDPC strategy, the proposed three vectors are selected based on the power errors rather than the sector where the grid voltage vector is located, which ensures that the duration times of the selected vectors are positive all the time. Iterative calculations of the cost function in traditional predictive control are also removed, which makes the proposed strategy easy to implement on digital signal processors(DSPs) for industrial applications. Results of experiments based on a 1 kW inverter setup validate the feasibility of the proposed three-vector based dead-beat MPDPC strategy. 展开更多
关键词 grid-connected inverter Model predictive CONTROL Direct POWER CONTROL THREE vectors Constant switching frequency POWER errors
原文传递
Active and Reactive Power Decoupling Control of Grid-Connected Inverters in Stationary Reference Frame
20
作者 Xin Zhao Liuchen Chang 《Chinese Journal of Electrical Engineering》 CSCD 2017年第3期18-24,共7页
Proportion resonant(PR)controllers are able to achieve zero steady-state error for AC input signals and are widely used for simplifying control systems in the stationary reference frame.However,power decoupling in the... Proportion resonant(PR)controllers are able to achieve zero steady-state error for AC input signals and are widely used for simplifying control systems in the stationary reference frame.However,power decoupling in the stationary reference frame with a PR controller has not been investigated thoroughly.Based on the complex vector model of a grid-connected inverter(GCI),this paper deduces theoretically the power coupling relationship of GCI with the traditional PR current controller.A modified PR controller is provided for achieving the power decoupling,and the design method of the controller is presented.Simulation and experimental results verify that there is coupling between active and reactive power using the traditional PR controller and the proposed method can realize the power decoupling. 展开更多
关键词 grid-connected inverter complex vector proportion resonant controller power decoupling control