In this paper, according to the temperature and strain distribution obtained by considering the Gaussian pump profile and dependence of physical properties on temperature, we derive an analytical model for refractive ...In this paper, according to the temperature and strain distribution obtained by considering the Gaussian pump profile and dependence of physical properties on temperature, we derive an analytical model for refractive index variations of the diode side-pumped Nd:YAG laser rod. Then we evaluate this model by numerical solution and our maximum relative errors are 5% and 10% for variations caused by thermo–optical and thermo–mechanical effects; respectively. Finally, we present an analytical model for calculating the focal length of the thermal lens and spherical aberration. This model is evaluated by experimental results.展开更多
According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotr...According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results.展开更多
The paper explores the evolution of thermal behavior of the material by studying the variations in thermal diffusivity using the single beam thermal lens(TL) technique. For this purpose, the decomposition of Cu(OH)_(2...The paper explores the evolution of thermal behavior of the material by studying the variations in thermal diffusivity using the single beam thermal lens(TL) technique. For this purpose, the decomposition of Cu(OH)_(2) into CuO is studied in a time range up to 120 h, by subjecting the sample to morphological, structural, and spectroscopic characterizations. The time evolution of thermal diffusivity can be divided into three regions for demonstrating the dynamics of the reaction. When the reaction is complete, the thermal diffusivity is also found to be saturated. In addition to the morphological modifications,from rods to flakes, the variations in the amount of hydroxyl group are attributed to be responsible for the enhancement of base fluid's thermal diffusivity by 165%. Thus the study unveils the role of hydroxyl groups in the thermal behavior of CuO.展开更多
A novel method for the determination of cationic surfactant by laser thermal lens spectrometry was developed. It was based on the reaction between 1-hydroxy-2-(5-nitro-2-Pyri- dylazo)-8-aminonaphthalene-3,6-disulfoni...A novel method for the determination of cationic surfactant by laser thermal lens spectrometry was developed. It was based on the reaction between 1-hydroxy-2-(5-nitro-2-Pyri- dylazo)-8-aminonaphthalene-3,6-disulfonic acid (5-NO2-PAH) and cationic surfactant to form 1:2 ionic association complex in a weakly basic medium (pH 9.44). The determination conditions and the mechanism were discussed. The method has been applied to the analysis of wastewater and moat water samples.展开更多
Analytical propagation formulas are derived for partially coherent controllable dark-hollow beams (CDHBs) through a thin lens based on the generalized Huygens-Fresnel integral. The expressions of the position for ma...Analytical propagation formulas are derived for partially coherent controllable dark-hollow beams (CDHBs) through a thin lens based on the generalized Huygens-Fresnel integral. The expressions of the position for maximum irradiance on-axis and the relative focal shift are evaluated by the analytical propagation formulas. Our numerical results show that both the relative focal shift and the effective beam width of focused partially coherent CDHBs are mainly determined by the initial transverse coherence width 6g and the Fresnel number Nw, which are also affected by the changes of both the dark-size adjusting parameter p and the order N of CDHBs.展开更多
This paper studies the focusing properties of Gaussian Schell-model (GSM) beams by an astigmatic aperture lens. It is shown that the axial irradiance distribution, the maximum axial irradiance and its position of fo...This paper studies the focusing properties of Gaussian Schell-model (GSM) beams by an astigmatic aperture lens. It is shown that the axial irradiance distribution, the maximum axial irradiance and its position of focused GSM beams by an astigmatic aperture lens depend upon the astigmatism of the lens, the coherence of partially coherent light, the truncation parameter of the aperture and Fresnel number. The numerical calculation results are given to illustrate how these parameters affect the focusing property.展开更多
In this study, wave propagation anisotropy in a triangular lattice crystal structure and its associated waveform shaping in a crystal structure are investigated theoretically. A directional variation in wave velocity ...In this study, wave propagation anisotropy in a triangular lattice crystal structure and its associated waveform shaping in a crystal structure are investigated theoretically. A directional variation in wave velocity inside a crystal structure is shown to cause bending wave envelopes. The authors report that a triangular lattice sonic crystal possesses six numbers of a high symmetry direction, which leads to a wave convergence caused by wave velocity anisotropy inside the crystal. However, two of them are utilized mostly in wave focusing by an acoustic fiat lens. Based on wave velocity anisotropy, the pseudo ideal imaging effect obtained in the second band of the flat lens is discussed.展开更多
We demonstrate the hybrid focusing points of sonic crystals for a multi-source array applied to flat sonic crystal lenses. The contributions of different point source couples form hybrid focusing points. Ray-trace ana...We demonstrate the hybrid focusing points of sonic crystals for a multi-source array applied to flat sonic crystal lenses. The contributions of different point source couples form hybrid focusing points. Ray-trace analyses are conducted for acoustic flat lenses with multi-source configurations. The finite-difference time-domain (FDTD) simulation of flat lenses with multi-source configurations demonstrates the establishment of pure and hybrid focusing points in a pyramidal constellation. The number of focusing points in the pyramidal constellation depends on the number of point sources. We propose an acoustic device for fine-tuning the location of a far-field hybrid focusing point and discuss its benefits for acoustic energy focusing application.展开更多
The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabricatio...The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays.展开更多
A new method for the determination of utratrace silver(I) by near field thermal lens spectrometry has been developed. This method is based on the silver(I) catalyzed discoloring reaction of bromocresol green oxidized...A new method for the determination of utratrace silver(I) by near field thermal lens spectrometry has been developed. This method is based on the silver(I) catalyzed discoloring reaction of bromocresol green oxidized by sodium persulphate in the presence of a, a-bipy as activator and Triton X-100 as sensitizer. The linear range of this method is 0~1.6 ng穖L-1 of silver. The detection limit is 2?0-2 ng穖L-1. The method has been applied to the determination of silver in lead power and photographic paper with satisfactory results.展开更多
The paper employs the principles of graph theory in nanobiophotonics, where the soot-assisted intra-pigmental energy transport in leaves is unveiled through the laser-induced thermal lens(TL) technique. Nanofluids wit...The paper employs the principles of graph theory in nanobiophotonics, where the soot-assisted intra-pigmental energy transport in leaves is unveiled through the laser-induced thermal lens(TL) technique. Nanofluids with different soot concentrations are sprayed over Lablab purpureus(L) sweet leaves, and the extracted pigments are analyzed. The graph features of the constructed complex network from the TL signal of the samples are analyzed to understand their variations with optical absorbance. Besides revealing the presence of optimum soot concentration that can enhance photosynthesis,the study brings out the potential application of graph features in nanobiophotonics.展开更多
<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediat...<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.展开更多
The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal le...The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10^-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.展开更多
The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume...The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume of ultrasound beams, HIFU can selectively ablate a targeted lesion of the pancreas without any damage to surrounding or overlying tissues. Preliminary studies suggest that this approach is technical safe and feasible, and can be used alone or in combination with systemic chemotherapy for the treatment of patients with locally advanced pancreatic cancer. It can effectively alleviate cancer-related abdominal pain, and may confer an additional survival benefit with few significant complications. This review provides a brief overview of HIFU, describes current clinical applications, summarizes characteristics of continuous and pulsed HIFU, and discusses future applications and challenges in the treatment of pancreatic cancer.展开更多
AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocell...AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocellular carcinoma were used to generate antitumor vaccines.Ten mice underwent HIFU ablation,and the remaining 10 mice received a sham-HIFU procedure with no ultrasound irradiation.Sixty normal mice were randomly divided into HIFU vaccine,tumor vaccine and control groups.These mice were immunized with HIFU-generated vaccine,tumor-generated vaccine,and saline,respectively.In addition,20 mice bearing H22 tumors were successfully treated with HIFU ablation. The protective immunity of the vaccinated mice was investigated before and after a subsequent H22 tumor challenge.Using the 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide assay,the cytotoxicity of splenic lymphocytes co-cultured with H22 cells wasdetermined in vitro before the tumor challenge,and tumor volume and survival were measured in vivo after the challenge in each group.The mechanism was also explored by loading the vaccines with bone marrowderived dendritic cells(DCs). RESULTS:Compared to the control,HIFU therapy, tumor-generated and HIFU-generated vaccines significantly increased cytolytic activity against H22 cells in the splenocytes of the vaccinated mice(P<0.001). The tumor volume was significantly smaller in the HIFU vaccine group than in the tumor vaccine group(P <0.05)and control group(P<0.01).However,there was no tumor growth after H22 rechallenge in the HIFU therapy group.Forty-eight-day survival rate was 100%in mice in the HIFU therapy group,30%in both the HIFU vaccine and tumor vaccine groups,and 20% in the control group,indicating that the HIFU-treated mice displayed significantly longer survival than the vaccinated mice in the remaining three groups(P< 0.001).After bone marrow-derived DCs were incubated with HIFU-generated and tumor-generated vaccines, the number of mature DCs expressing MHC-Ⅱ + ,CD80 + and CD86 + molecules was significantly increased,and interleukin-12 and interferon-γlevels were significantly higher in the supernatants when compared with immature DCs incubated with mouse serum(P<0.001). However,no differences of the number of mature DCs and cytokine levels were observed between the HIFU- generated and tumor-generated vaccines(P>0.05). CONCLUSION:Tumor debris remaining after HIFU can improve tumor immunogenicity.This debris releases tumor antigens as an effective vaccine to develop host antitumor immune response after HIFU ablation.展开更多
Recent advances in high intensity focused ultrasound(HIFU),which was developed in the 1940s as a viable thermal tissue ablation approach,have increased its popularity.In clinics,HIFU has been applied to treat a variet...Recent advances in high intensity focused ultrasound(HIFU),which was developed in the 1940s as a viable thermal tissue ablation approach,have increased its popularity.In clinics,HIFU has been applied to treat a variety of solid malignant tumors in a well-defined volume,including the pancreas,liver,prostate,breast,uterine fibroids,and soft-tissue sarcomas.In comparison to conventional tumor/cancer treatment modalities,such as open surgery,radio-and chemo-therapy,HIFU has the advantages of non-invasion,non-ionization,and fewer complications after treatment.Over 100 000 cases have been treated throughout the world with great success.The fundamental principles of HIFU ablation are coagulative thermal necrosis due to the absorption of ultrasound energy during transmission in tissue and the induced cavitation damage.This paper reviews the clinical outcomes of HIFU ablation for applicable cancers,and then summarizes the recommendations for a satisfactory HIFU treatment according to clinical experience.In addition,the current challenges in HIFU for engineers and physicians are also included.More recent horizons have broadened the application of HIFU in tumor treatment,such as HIFU-mediated drug delivery,vessel occlusion,and soft tissue erosion(“histotripsy”).In summary,HIFU is likely to play a significant role in the future oncology practice.展开更多
An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model ...An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model has been developed and an optimization methodhas been introduced into computation for designing the electrostatic focusing field of the imagingsystem.展开更多
A parametric study was performed to design a device capable of treating small targeted regions within the prostate using high intensity focused ultrasound, while sparing the surrounding organs and minimizing the numbe...A parametric study was performed to design a device capable of treating small targeted regions within the prostate using high intensity focused ultrasound, while sparing the surrounding organs and minimizing the number of elements. The optimal focal length (L), operating frequency (f), element size (a) and central opening radius for lodging an imaging probe (r) of a device that would safely treat tissue within the prostate were obtained. Images from the Visible Human Project were used to determine simulated organ sizes and treatment locations. Elliptical tumors were placed throughout the simulated prostate and their lateral and axial limits were selected as test locations. Using graphics processors, the acoustic field and Bio-Heat Transfer Equation were solved to calculate the heating produced during a simulated treatment. L, f, a and r were varied from 45 to 75 mm, 2.25 to 3 MHz, 1.5 to 8 times the wavelength and 9 to 12.5 mm, respectively. The resulting optimal device was a 761-element concentric-ring transducer with L = 68 mm, f = 2.75 MHz, a = 2.05λ and r = 9 mm. Simulated thermal lesions showed that it was possible to treat target tumors consistent with reported locations and sizes for prostate cancer.展开更多
文摘In this paper, according to the temperature and strain distribution obtained by considering the Gaussian pump profile and dependence of physical properties on temperature, we derive an analytical model for refractive index variations of the diode side-pumped Nd:YAG laser rod. Then we evaluate this model by numerical solution and our maximum relative errors are 5% and 10% for variations caused by thermo–optical and thermo–mechanical effects; respectively. Finally, we present an analytical model for calculating the focal length of the thermal lens and spherical aberration. This model is evaluated by experimental results.
基金Project supported by the National Natural Science Foundation of China (Grant Nos. 11179010 and 11075017 )the Natural Science Foundation of Beijing,China (Grant No. 1102019)the Specialized Research Fund for the Doctoral Program of Higher Education of China (Grant No. 20100003120010)
文摘According to intensity distribution of the synchrotron radiation source focused by a toroidal mirror at the Beijing synchrotron radiation biological macromolecule station, theoretical modeling of the Beijing synchrotron radiation source is developed for capillary optics. Using this theoretical modeling, the influences of the configuration curve of the polycapillary X-ray lens on transmission efficiency and working distance are analyzed. The experimental results of the transmission efficiency and working distance at the biological macromolecule station are in good agreement with the theoretical results.
文摘The paper explores the evolution of thermal behavior of the material by studying the variations in thermal diffusivity using the single beam thermal lens(TL) technique. For this purpose, the decomposition of Cu(OH)_(2) into CuO is studied in a time range up to 120 h, by subjecting the sample to morphological, structural, and spectroscopic characterizations. The time evolution of thermal diffusivity can be divided into three regions for demonstrating the dynamics of the reaction. When the reaction is complete, the thermal diffusivity is also found to be saturated. In addition to the morphological modifications,from rods to flakes, the variations in the amount of hydroxyl group are attributed to be responsible for the enhancement of base fluid's thermal diffusivity by 165%. Thus the study unveils the role of hydroxyl groups in the thermal behavior of CuO.
文摘A novel method for the determination of cationic surfactant by laser thermal lens spectrometry was developed. It was based on the reaction between 1-hydroxy-2-(5-nitro-2-Pyri- dylazo)-8-aminonaphthalene-3,6-disulfonic acid (5-NO2-PAH) and cationic surfactant to form 1:2 ionic association complex in a weakly basic medium (pH 9.44). The determination conditions and the mechanism were discussed. The method has been applied to the analysis of wastewater and moat water samples.
基金Supported by the National Natural Science Foundation of China under Grant No 61201193
文摘Analytical propagation formulas are derived for partially coherent controllable dark-hollow beams (CDHBs) through a thin lens based on the generalized Huygens-Fresnel integral. The expressions of the position for maximum irradiance on-axis and the relative focal shift are evaluated by the analytical propagation formulas. Our numerical results show that both the relative focal shift and the effective beam width of focused partially coherent CDHBs are mainly determined by the initial transverse coherence width 6g and the Fresnel number Nw, which are also affected by the changes of both the dark-size adjusting parameter p and the order N of CDHBs.
基金Project supported by the Natural Science Foundation of Henan Province, China (Grant No 0611054000).
文摘This paper studies the focusing properties of Gaussian Schell-model (GSM) beams by an astigmatic aperture lens. It is shown that the axial irradiance distribution, the maximum axial irradiance and its position of focused GSM beams by an astigmatic aperture lens depend upon the astigmatism of the lens, the coherence of partially coherent light, the truncation parameter of the aperture and Fresnel number. The numerical calculation results are given to illustrate how these parameters affect the focusing property.
文摘In this study, wave propagation anisotropy in a triangular lattice crystal structure and its associated waveform shaping in a crystal structure are investigated theoretically. A directional variation in wave velocity inside a crystal structure is shown to cause bending wave envelopes. The authors report that a triangular lattice sonic crystal possesses six numbers of a high symmetry direction, which leads to a wave convergence caused by wave velocity anisotropy inside the crystal. However, two of them are utilized mostly in wave focusing by an acoustic fiat lens. Based on wave velocity anisotropy, the pseudo ideal imaging effect obtained in the second band of the flat lens is discussed.
文摘We demonstrate the hybrid focusing points of sonic crystals for a multi-source array applied to flat sonic crystal lenses. The contributions of different point source couples form hybrid focusing points. Ray-trace analyses are conducted for acoustic flat lenses with multi-source configurations. The finite-difference time-domain (FDTD) simulation of flat lenses with multi-source configurations demonstrates the establishment of pure and hybrid focusing points in a pyramidal constellation. The number of focusing points in the pyramidal constellation depends on the number of point sources. We propose an acoustic device for fine-tuning the location of a far-field hybrid focusing point and discuss its benefits for acoustic energy focusing application.
基金Project supported by the National Natural Science Foundation of China (Grant No 10174079), the Natural Science Foundation of Zhejiang Province, China (Grant No Y104203) and BEPC National Laboratory (Grant No sr-03062).
文摘The x-ray compound lens is a novel refractive x-ray optical device. This paper reports the authors' recent research on a polymethyl methacrylate (PMMA) compound x-ray lens. Firstly the designing and LIGA fabrication process for the PMMA compound x-ray lens are briefly described. Then, a method for theoretical analysis, as well as the experimental system for measurement is also introduced. Finally, the focusing spots for 8keV monochromatic x-rays by the PMMA compound x-ray lens are measured and analysed. According to the experimental results, it is concluded that the PMMA compound x-ray lens promises a good focusing performance under the high-energy x-rays.
文摘A new method for the determination of utratrace silver(I) by near field thermal lens spectrometry has been developed. This method is based on the silver(I) catalyzed discoloring reaction of bromocresol green oxidized by sodium persulphate in the presence of a, a-bipy as activator and Triton X-100 as sensitizer. The linear range of this method is 0~1.6 ng穖L-1 of silver. The detection limit is 2?0-2 ng穖L-1. The method has been applied to the determination of silver in lead power and photographic paper with satisfactory results.
文摘The paper employs the principles of graph theory in nanobiophotonics, where the soot-assisted intra-pigmental energy transport in leaves is unveiled through the laser-induced thermal lens(TL) technique. Nanofluids with different soot concentrations are sprayed over Lablab purpureus(L) sweet leaves, and the extracted pigments are analyzed. The graph features of the constructed complex network from the TL signal of the samples are analyzed to understand their variations with optical absorbance. Besides revealing the presence of optimum soot concentration that can enhance photosynthesis,the study brings out the potential application of graph features in nanobiophotonics.
文摘<strong>Purpose:</strong> To clinically evaluate a new extended depth of focus intraocular lens (ISOPURE, PhysIOL) with optic design modification based on a unique polynomial concept to improve intermediate vision while keeping the quality of distance vision equal to a monofocal lens. <strong>Methods:</strong> 18 patients (11 female, 7 male, mean age of 69.4 years) with bilateral cataract and regular corneal astigmatism ≤ 1.0 D underwent bilateral cataract surgery with ISOPURE implantation. Patients were followed for up to 6 months. Measured parameters were uncorrected (UDVA) and corrected distance visual acuity (CDVA), uncorrected (UIVA) and distance-corrected intermediate visual acuity at 80 cm and 66 cm (DCI80VA, DCI66VA) subjective refraction, defocus curve, tolerance of cylinder induction, and contrast sensitivity. The data from all implanted eyes (all-eyes) and a subset only including the first eye implanted for each patient were analysed. <strong>Results:</strong> The mean manifest refraction spherical equivalent (MRSE) decreased from 1.05 D pre-operatively to ?0.15 D at the 4 - 6 month assessment, with 80.6% of eyes within ±0.50 D of emmetropia. At the final follow-up, mean (SD) monocular CDVA was ?0.06 (0.04) logMAR, DCI80VA was 0.18 (0.08) logMAR and DCI66VA was 0.27 (0.13) logMAR. Despite a cylinder induction of ?0.50 D, uncorrected distance visual acuity of 0.02 logMAR was still achieved. <strong>Conclusion:</strong> The ISOPURE intraocular lens provides excellent distance corrected visual acuity for far and intermediate distances along with high contrast sensitivity and good tolerance of residual refractive cylinder.
文摘The thermal lens effect has emerged in recent years as a novel ,highly sensitive tool for the study of the very weak molecular absorption of light energy,This paper discusses the theory and technique of the thermal lens measurement.Some opplications of the thermal lens measurement are described.A mode-mismatched dual-beam thermal lens experimental arragement with a modulated probe beam ,designed by the authors.for trace analysis is presented,and its detection limit was found to be 4.1×10^-7 for Cu(Ⅱ) in ethanol and 80 mW excitation power.
文摘The noninvasive ablation of pancreatic cancer with high intensity focused ultrasound(HIFU) energy is received increasingly widespread interest. With rapidly temperature rise to cytotoxic levels within the focal volume of ultrasound beams, HIFU can selectively ablate a targeted lesion of the pancreas without any damage to surrounding or overlying tissues. Preliminary studies suggest that this approach is technical safe and feasible, and can be used alone or in combination with systemic chemotherapy for the treatment of patients with locally advanced pancreatic cancer. It can effectively alleviate cancer-related abdominal pain, and may confer an additional survival benefit with few significant complications. This review provides a brief overview of HIFU, describes current clinical applications, summarizes characteristics of continuous and pulsed HIFU, and discusses future applications and challenges in the treatment of pancreatic cancer.
基金Supported by The Foundation of Ministry of Education of China,No.IRT0454
文摘AIM:To investigate whether tumor debris created by high-intensity focused ultrasound(HIFU)could trigger antitumor immunity in a mouse hepatocellular carcinoma model. METHODS:Twenty C57BL/6J mice bearing H22 hepatocellular carcinoma were used to generate antitumor vaccines.Ten mice underwent HIFU ablation,and the remaining 10 mice received a sham-HIFU procedure with no ultrasound irradiation.Sixty normal mice were randomly divided into HIFU vaccine,tumor vaccine and control groups.These mice were immunized with HIFU-generated vaccine,tumor-generated vaccine,and saline,respectively.In addition,20 mice bearing H22 tumors were successfully treated with HIFU ablation. The protective immunity of the vaccinated mice was investigated before and after a subsequent H22 tumor challenge.Using the 3-(4,5-dimethylthiazol-2-yl)-2,5- diphenyltetrazolium bromide assay,the cytotoxicity of splenic lymphocytes co-cultured with H22 cells wasdetermined in vitro before the tumor challenge,and tumor volume and survival were measured in vivo after the challenge in each group.The mechanism was also explored by loading the vaccines with bone marrowderived dendritic cells(DCs). RESULTS:Compared to the control,HIFU therapy, tumor-generated and HIFU-generated vaccines significantly increased cytolytic activity against H22 cells in the splenocytes of the vaccinated mice(P<0.001). The tumor volume was significantly smaller in the HIFU vaccine group than in the tumor vaccine group(P <0.05)and control group(P<0.01).However,there was no tumor growth after H22 rechallenge in the HIFU therapy group.Forty-eight-day survival rate was 100%in mice in the HIFU therapy group,30%in both the HIFU vaccine and tumor vaccine groups,and 20% in the control group,indicating that the HIFU-treated mice displayed significantly longer survival than the vaccinated mice in the remaining three groups(P< 0.001).After bone marrow-derived DCs were incubated with HIFU-generated and tumor-generated vaccines, the number of mature DCs expressing MHC-Ⅱ + ,CD80 + and CD86 + molecules was significantly increased,and interleukin-12 and interferon-γlevels were significantly higher in the supernatants when compared with immature DCs incubated with mouse serum(P<0.001). However,no differences of the number of mature DCs and cytokine levels were observed between the HIFU- generated and tumor-generated vaccines(P>0.05). CONCLUSION:Tumor debris remaining after HIFU can improve tumor immunogenicity.This debris releases tumor antigens as an effective vaccine to develop host antitumor immune response after HIFU ablation.
文摘Recent advances in high intensity focused ultrasound(HIFU),which was developed in the 1940s as a viable thermal tissue ablation approach,have increased its popularity.In clinics,HIFU has been applied to treat a variety of solid malignant tumors in a well-defined volume,including the pancreas,liver,prostate,breast,uterine fibroids,and soft-tissue sarcomas.In comparison to conventional tumor/cancer treatment modalities,such as open surgery,radio-and chemo-therapy,HIFU has the advantages of non-invasion,non-ionization,and fewer complications after treatment.Over 100 000 cases have been treated throughout the world with great success.The fundamental principles of HIFU ablation are coagulative thermal necrosis due to the absorption of ultrasound energy during transmission in tissue and the induced cavitation damage.This paper reviews the clinical outcomes of HIFU ablation for applicable cancers,and then summarizes the recommendations for a satisfactory HIFU treatment according to clinical experience.In addition,the current challenges in HIFU for engineers and physicians are also included.More recent horizons have broadened the application of HIFU in tumor treatment,such as HIFU-mediated drug delivery,vessel occlusion,and soft tissue erosion(“histotripsy”).In summary,HIFU is likely to play a significant role in the future oncology practice.
文摘An inverse design of electrostatic focusing field for electrostatic and magneticimaging is investigated.Using the potential superimposition theorem of electrostatic field inmulti-electrode system,a mathematical model has been developed and an optimization methodhas been introduced into computation for designing the electrostatic focusing field of the imagingsystem.
文摘A parametric study was performed to design a device capable of treating small targeted regions within the prostate using high intensity focused ultrasound, while sparing the surrounding organs and minimizing the number of elements. The optimal focal length (L), operating frequency (f), element size (a) and central opening radius for lodging an imaging probe (r) of a device that would safely treat tissue within the prostate were obtained. Images from the Visible Human Project were used to determine simulated organ sizes and treatment locations. Elliptical tumors were placed throughout the simulated prostate and their lateral and axial limits were selected as test locations. Using graphics processors, the acoustic field and Bio-Heat Transfer Equation were solved to calculate the heating produced during a simulated treatment. L, f, a and r were varied from 45 to 75 mm, 2.25 to 3 MHz, 1.5 to 8 times the wavelength and 9 to 12.5 mm, respectively. The resulting optimal device was a 761-element concentric-ring transducer with L = 68 mm, f = 2.75 MHz, a = 2.05λ and r = 9 mm. Simulated thermal lesions showed that it was possible to treat target tumors consistent with reported locations and sizes for prostate cancer.