期刊文献+
共找到3篇文章
< 1 >
每页显示 20 50 100
Focused electron beam transport through a long narrow metal tube at elevated pressures in the forevacuum range
1
作者 Ilya BAKEEV Kirill KARPOV +2 位作者 Aleksandr KLIMOV Efim OKS Aleksey ZENIN 《Plasma Science and Technology》 SCIE EI CAS CSCD 2023年第1期128-134,共7页
We present here our investigations of the features of focused electron beam transport in free space at elevated pressures of a few pascals.We have explored the effect of the beam accelerating voltage,operating gas pre... We present here our investigations of the features of focused electron beam transport in free space at elevated pressures of a few pascals.We have explored the effect of the beam accelerating voltage,operating gas pressure,and magnetic focusing upon the trajectory of beam electrons in the crossover region,in particular on the beam convergence and divergence angles.It is shown that for the forevacuum pressure range of 2-5 Pa explored,a distinctive feature of the propagation of a focused electron beam with a current of up to 20 mA at an accelerating voltage of 10-20 kV is the difference in the angles of convergence(before the focus)and divergence(after the focus).Whereas at a low pressure of 2 Pa the divergence angle is smaller than the convergence angle,as the pressure increases the divergence angle increases and for pressures greater than 5 Pa the divergence angle is greater than the convergence angle.The results obtained were used in experiments on electron beam transport through a long narrow metal tube with a diameter of 5.8-9.2 mm and length of 10-30 cm.We show that for a 30 cm long tube of 7.5 mm diameter,the focused beam transmission can exceed 70%. 展开更多
关键词 focused electron beam plasma electron source forevacuum pressure range long metal tube
下载PDF
预真空灭菌器BD试验失败原因分析及护理干预 被引量:5
2
作者 尹若袁 黄美红 徐洲 《护理实践与研究》 2010年第1期75-76,共2页
目的:对BD试验失败原因进行分析,明确原因后制定相应对策,以指导工作。方法:对2004年1月~2008年12月BD试验的效果进行分析。结果:监测结果为成功率呈上升趋势。结论:由于操作技术和设备因素等原因造成BD试验失败,提高工作人员的技术水... 目的:对BD试验失败原因进行分析,明确原因后制定相应对策,以指导工作。方法:对2004年1月~2008年12月BD试验的效果进行分析。结果:监测结果为成功率呈上升趋势。结论:由于操作技术和设备因素等原因造成BD试验失败,提高工作人员的技术水平,加强规范操作,提升素质,完善设备的维护保养,及时排除故障,可提高BD试验的成功率,达到确保医疗安全的目的。 展开更多
关键词 BD试验 预真空灭菌器 失败原因
下载PDF
预真空蒸汽灭菌器B-D试验监测效果分析 被引量:1
3
作者 张鲜利 张红军 付敏 《医疗卫生装备》 CAS 2007年第6期64-64,共1页
通过脉动预真空压力蒸汽灭菌器B-D试验监测,分析并找出影响B-D试验结果的不合格因素。采取有效方法,排除影响B-D监测结果因素,及时发现问题,对灭菌器进行检修。经常对预真空蒸汽灭菌器进行保养,严格管理,确保预真空压力蒸汽灭菌器灭菌... 通过脉动预真空压力蒸汽灭菌器B-D试验监测,分析并找出影响B-D试验结果的不合格因素。采取有效方法,排除影响B-D监测结果因素,及时发现问题,对灭菌器进行检修。经常对预真空蒸汽灭菌器进行保养,严格管理,确保预真空压力蒸汽灭菌器灭菌按程序安全运行,保证灭菌质量合格,使临床使用安全、可靠。 展开更多
关键词 B-D试验 脉动预真空压力蒸汽灭菌器 监测
下载PDF
上一页 1 下一页 到第