The increasing demand for wastewater treatment has become a notable trend for addressing global water scarcity.However,fouling is a significant challenge for wastewater distribution engineering systems.This study prov...The increasing demand for wastewater treatment has become a notable trend for addressing global water scarcity.However,fouling is a significant challenge for wastewater distribution engineering systems.This study provides an approach using nanobubbles(NBs)to control fouling.The antifouling capacities of three types of NBs,six oxygen concentrations,and two application procedures(prevention and removal)are investigated.The results show that NBs effectively mitigate composite fouling—including biofouling,inorganic scaling,and particulate fouling—in comparison with the non-NBs group.More specifically,hydroxyl radicals generated by the self-collapse of NBs oxidize organics and kill microorganisms in wastewater.The negatively charged surfaces of the NBs transform the crystalline form of CaCO_(3)from calcite to looser aragonite,which reduces the likelihood of ion precipitation.Furthermore,the NBs gas-liquid interfaces act as gas"bridges"between colloidal particles,enhancing the removal of particles from wastewater.Lastly,although the NBs inhibit the growth of fouling,they do not significantly remove the already adhered fouling in non-NBs treated groups.This study anticipates that the application of NBs will address the significant fouling issue for various wastewater distribution engineering systems in order to meet the global challenge of sustainable water supplies.展开更多
Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optim...Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optimization of CCWS often prioritizes short-term flow velocity optimization for minimizing power consumption,without considering fouling.However,low flow velocity promotes fouling.Therefore,it's crucial to balance fouling and energy/water conservation for optimal CCWS long-term operation.This study proposes a mixed-integer nonlinear programming(MINLP)model to achieve this goal.The model considers fouling in the pipeline,dynamic concentration cycle,and variable frequency drive to optimize the synergy between heat transfer,pressure drop,and fouling.By optimizing the concentration cycle of the CCWS,water conservation and fouling control can be achieved.The model can obtain the optimal operating parameters for different operation intervals,including the number of pumps,frequency,and valve local resistance coefficient.Sensitivity experiments on cycle and environmental temperature reveal that as the cycle increases,the marginal benefits of energy/water conservation decrease.In periods with minimal impact on fouling rate,energy/water conservation can be achieved by increasing the cycle while maintaining a low fouling rate.Overall,the proposed model has significant energy/water saving effects and can comprehensively optimize the CCWS through its incorporation of fouling and cycle optimization.展开更多
A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid do...A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact.展开更多
The membrane fouling phenomenon,reflected with various fouling characterization in the membrane bioreactor(MBR)process,is so complicated to distinguish.This paper proposes a multivariable identification model(MIM)base...The membrane fouling phenomenon,reflected with various fouling characterization in the membrane bioreactor(MBR)process,is so complicated to distinguish.This paper proposes a multivariable identification model(MIM)based on a compacted cascade neural network to identify membrane fouling accurately.Firstly,a multivariable model is proposed to calculate multiple indicators of membrane fouling using a cascade neural network,which could avoid the interference of the overlap inputs.Secondly,an unsupervised pretraining algorithm was developed with periodic information of membrane fouling to obtain the compact structure of MIM.Thirdly,a hierarchical learning algorithm was proposed to update the parameters of MIM for improving the identification accuracy online.Finally,the proposed model was tested in real plants to evaluate its efficiency and effectiveness.Experimental results have verified the benefits of the proposed method.展开更多
In this research,an Underwater Biofouling Panel(UWBFP)system was erected for the qualitative and quantitative estimation of macro fouling organisms in the Gulf of Mannar.Forty-four biofoulers were identified from four...In this research,an Underwater Biofouling Panel(UWBFP)system was erected for the qualitative and quantitative estimation of macro fouling organisms in the Gulf of Mannar.Forty-four biofoulers were identified from four types of selected test panels.Among these biofoulers,Amphibalanus amphitrite(Darwin,1854)was the dominant one.The concrete panel encouraged the highest barnacle density compared to the other panels.Three series of test panels were used to assess the seasonal density of biofouling communities.The overall variation in barnacle count in the seaward and shoreward sides of all these three series were tested.They were found to be significantly different from each other.The greater variations in the barnacle density observed in this study in A-series of test panels could be due to the lack of or absence of other foulers to compete within the fortnight.The Shannon-Wiener species diversity index showed the highest diversity in wood substratum among the three series with greater accumulation of different types of fouling organisms.Multivariate analyses were also performed to understand the seasonal variation as well as the settlement pattern on the different directions of test panels based on validated data.PCA showed a strong variability(PC1 between 70.8%and 98.6%variance)between the directions of the panels in connection with barnacle density.The shade plot and CAP analysis segregated the short-term A-series test panels from the long-term(B-and C-series)test panels.Hence,the output was helpful in understanding the recruitment status of various faunal resources involved in the biofouling processes.展开更多
A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four type...A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four types of engineering plastic particles with different physical properties are selected as the solid working media. The effect of particle types on the fluidization and distribution of particles in the boiler is investigated under different feedwater flow rates and amount of added particles by using the charge couple device image measurement and acquisition system. The results show that all kinds of particles can't be normally fluidized and accumulate in the drum at low amount of added particles and feedwater flow rate. The particles with great density and low sphericity are more likely to accumulate. The average solid holdup in the riser tubes increases with the increase in feedwater flow rate and the amount of added particles. The non-uniform degree of particle distribution in the riser tubes generally decreases with the increase in feedwater flow rate and the amount of added particles. The particles with small density and settling velocity have high average solid holdup in the riser tubes under close sphericity. In generally,the smaller the density and settling velocity, the more uniform the particle distribution in the riser tubes.Three-dimensional diagrams of the non-uniform degree of particle distribution in the riser tubes of the boiler are established.展开更多
To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge me...To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge mechanism,the multi-physical field coupling software COMSOL was used to numerically simulate the fouling characteristics,explored the calculation method of ESDD,and demonstrated its rationality.Based on this method,the pollution characteristics of the composite insulator under the pollution fog environment were studied,and the influence of wind speed,droplet size,and voltage type on the pollution characteristics of the composite insulator was analyzed.The results showed that:with the increase in wind speed,the amount of accumulated pollution of insulator increases in the range of droplet size,and the relationship between wind speed and accumulated pollution is approximately linear;at the same wind speed,the amount of accumulated pollution increases with the increase of droplet size under the action of DC voltage;when there is no voltage,the amount of dirt on the upper surface of the insulator is more than that on the lower surface,while it is the opposite under DC voltage.展开更多
Biofouling is an important factor that affects bivalve farming industry. Fouling organisms may reduce growth and survival rate of the cultured species. Fouler are often filter feeders, so they are potential competitor...Biofouling is an important factor that affects bivalve farming industry. Fouling organisms may reduce growth and survival rate of the cultured species. Fouler are often filter feeders, so they are potential competitors for food resource with the cultured species. The present study was conducted to measure the impact of fouling on food uptake and nutrient release in April, 2006 in Daya Bay near Guangzhou, China. Results showed that fouling organisms had significant effect on food uptake and nutrient release. The chlorophyll a uptake rate of fouled scallops was 7.53 / Lh ±1.416 / Lh in April, significantly higher than those of cleaned scallops, Le., 4.23 / Lh±2.744 / Lh. The consumption of total particulate matter by fouled scallops in April was 5.52 / Lh± 0.818 / Lh; the corresponding results for cleaned scallops are 2.49 / Lh ±0.614 / Lh Fouling increased ammonia release significantly. The ammonia release rate of fouled scallops was 33.81/Lh ±7.699 / Lh in April, while cleaned scallops released 2.46 / Lh ±0.511 / Lh ammonia. Phosphate uptake of fouled scallops was 2.01± 0.699 / Lh and cleaned scallops released phosphate 6.01 / Lh + 0.876 / Lh in April. There was not significant difference in nitrate consumption between fouled and cleaned scallops. According to the phytoplankton classification of input and output water samples, fouled scallops filtered more phytoplankton species than cleaned scallops. Therefore, this study showed that fouling contributed much to phytoplankton depletion and concentration increase of ammonia in water.展开更多
This paper summarizes a nontoxic Anti-fouling coating utilizing capsaicin as an anti-fouling agent. The capsaicin constituent used in the coating has a rating from about 100 000 to about 1 500 000 Scoville Heat Units....This paper summarizes a nontoxic Anti-fouling coating utilizing capsaicin as an anti-fouling agent. The capsaicin constituent used in the coating has a rating from about 100 000 to about 1 500 000 Scoville Heat Units. The capsaicin is mixed with a silicon dioxide and then solubilized into a free-flowing homogeneous liquid oleoresin composition by adding a solvent to increase solubility and facilitate mixing. The oleoresin capsaicin liquid solution is mixed with a suitable corrosion resistant epoxy resin, which is then mixed with a hardening catalyst and applied to the surface to be treated.展开更多
A dielectric analysis model for the fouling layer on the polyethersulfone composite ultrafiltration (UF) membrane and solution system, which consists of the solution, concentration polarization layer (CPL), and ca...A dielectric analysis model for the fouling layer on the polyethersulfone composite ultrafiltration (UF) membrane and solution system, which consists of the solution, concentration polarization layer (CPL), and cake layer, was established by virtue of the interfacial polarization and the electrostatic field theory. The effect of some important parameters, such as the depth, conductivity of CPL, and cake layer, on the dielectric spectroscopy (or dielectric relaxation properties) of the UF system was discussed by the parameter sensitivity analysis and the dielectric measurement. The simulations indicate that the CPL can be created rapidly and the cake layer formation is the dynamic balance process of growth and erosion in the process of UF. The key factor affecting on the dielectric spectrum of UF system is the electrical properties of the CPL and the cake layer. In comparison to the results of dielectric measurement, the simulations indicate that the model proposed in this work is valid and reliable to some degree for describing and explaining the dielectric relaxation phenomenon in UF system. It is very important to further understand the fouling behavior of membrane surface and optimize the controlling techniques of membrane fouling in the process of UF.展开更多
Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, i...Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills.展开更多
The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM)....The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM). A relatively higher molecular weight (MW) of hydrophobic compounds was responsible for a rapid decline in the ultrafiltration flux. Coagulation could effectively remove the hydrophobic organics, resulting in the increase of flux. It was found that a lower MW of neutral hydrophilic compounds, which could remove inadequately by coagulation, was responsible for the slow declining flux. The fluxes in the filtration of coagulated water and supernatant water were compared and the results showed that a lower MW of neutral hydrophilic compounds remained in the supernatant water after coagulation could be rejected by a membrane, resulting in fouling. It was also found that the coagulated flocs could absorb neutral hydrophilic compounds effectively. Therefore, with the coagulated flocs formed on the membrane surface, the flux decline could be improved.展开更多
Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activa...Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activated sludge system were investigated. The membrane foulants was also characterized by Fourier transform infrared (FTIR) spectroscopy technique. The results showed that the aerobic granular sludge had excellent denitrification ability; the removal efficiency of TN could reach 90%. The aerobic granular sludge could alleviate membrane fouling effectively. The steady membrane flux of aerobic granular sludge was twice as much as that of activated sludge system. In addition, it was found that the aerobic granular sludge could result in severe membrane pore-blocking, however, the activated sludge could cause severe cake fouling. The major components of the foulants were identified as comprising of proteins and polysaccharide materials.展开更多
Two parallel membrane bioreactors (MBRs) were operated under different calcium dosages (168.5, 27 mg/L) to gain a better understanding of the mechanism of retarding membrane fouling by adding calcium. The results ...Two parallel membrane bioreactors (MBRs) were operated under different calcium dosages (168.5, 27 mg/L) to gain a better understanding of the mechanism of retarding membrane fouling by adding calcium. The results showed that the particle size of sludge flocs increased and the particle size distribution tended to be narrow at the optimum dosage (168.5 mg/L). Calcium was effective in decreasing loosely bound extracellular polymeric substances (LB-EPS) in microbial flocs and soluble microbial products (SMP) in the supernatant at the dosage of 168.5 mg/L by strengthening the neutralization and bridging of EPS with flocs. Furthermore, the amount of CODs and CODc decreased in both the mixed liquor and the fouling cake layer on the membrane surface. In order to compare the filtration characteristics of cake layers from the MBRs with the two calcium dosages, the specific cake resistance and the compressibility coefficient were measured. The specific cake resistance from the MBR with optimum dosage (168.5 mg/L) was distinctly lower than that with low dosage (27 mg/L). The compressibility coefficient of the cake layers under two dosages were respectively attained as 0.65, 0.91. Scanning electron microscopy (SEM) and three-dimensional confocal scanning laser microscope analysis (CLSM) images were utilized to observe the gel layer directly.展开更多
In this study, the effect of zeolite powder addition on submerged membrane bioreactor (SMBR) on membrane permeability, and the removals for COD, NH3-N, TN were investigated. Through the parallel operation of control...In this study, the effect of zeolite powder addition on submerged membrane bioreactor (SMBR) on membrane permeability, and the removals for COD, NH3-N, TN were investigated. Through the parallel operation of control and test systems, it was found that the zeolite powder addition could alleviate the ultra-filtration membrane fouling and enhance the membrane permeability. On the basis of experimental investigations, a concept of "protection coating layer" was proposed to illustrate the phenomenon of UF membrane fouling. In addition, the removal for COD in test system was more stable, a little higher compared to the control system. Due to the combination of nitrification and ion exchange, a more excellent removal for NH3-N in test system was obtained regardless of influent NH3-N loading rate. It was also found that a mean 25% higher TN removal took place in the test system, and ion exchange and simultaneous nitrification and de-nitrification were analyzed to be main factors. During the stable operation period, the SOURs of test zeolite powder added sludge and control activated sludge were measured to be 75 mgO2/(gMLVSS, h) and 24 mgO2/(gMLVSS, h) respectively, it meant that the zeolite powder addition could enhance the microorganism activity significantly.展开更多
Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV...Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV254 removals by the UF with in-line coagulation at pH 7 were increased from 28% to 53% and 40% to 78% in comparison with direct UF treatment respectively. At the same time, the analysis of high performance liquid chromatography showed that UF with coagulation had significant improvement of removal of humic acid with molecular weights less than 6000 Da in particular. Compared to direct UF, the in-line coagulation UF also kept more constant permeate flux and very slight increase oftransmembrane pressure during a filtration circle. Two typical membrane fouling models were used by inducing two coefficients Kc and Kp corresponding to cake filtration model and pore narrowing model respectively. It was found that membrane fouling by pore-narrowing effect was effectively alleviated and that by cake-filtration was much decreased by in-line coagulation. Under the condition of coagulation prior to ultrafiltration at pH 7, the cake layer formed on the membrane surface became thicker, but the membrane filtration resistance was lower than that at pH 5 with the extension of operation time.展开更多
High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave a...High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave at 300 -C for 1 h,and the treated coals were analyzed,along with the oxygen-containing functional groups determined by Fourier transform infrared spectrometer(FT-IR).Then the alkali species and other components in the coal ash were quantified by X-ray fluorescence(XRF)for evaluating the ash slagging and fouling tendency.Apart from this,FactSage was adopted to simulate the occurrence and transformation of alkali species during coal thermal conversion ending at various temperatures.The findings indicate that the treated coals are superior to the parent ones in terms of certain remarkable changes via HTP.The moisture,oxygen and sulfur of the hydrothermally treated coals decline obviously,while the calorific value rises sharply.HTP could reduce the alkali species to less than 2%(%,by weight,equivalent to Na2O in dry ash),with a maximum removal ratio of 88.9%,lowering the ash slagging and fouling tendency.The proposed mechanism of HTP was that the alkali species in coal matrix became released due to the breakage of the coal functional groups and micropores during HTP.展开更多
Ceramic ultrafiltration membranes were used to separate titanium silicalite-1 (TS-1) catalysts from the slurry of catalytic ammoximation of cyclohexanone to oxime. Silica was shown to have a great effect on membrane...Ceramic ultrafiltration membranes were used to separate titanium silicalite-1 (TS-1) catalysts from the slurry of catalytic ammoximation of cyclohexanone to oxime. Silica was shown to have a great effect on membrane fouling in the alkaline environment of this system. In the ammoximation system, there are three main silica sources, which are residual silica on the catalyst particles surface during preparation, silica dissolved from TS-1 catalyst particles by ammonia solvent, and silica sol added into the reaction slurry to inhibit the dissolution erosion of the TS-1 catalyst. The silica dissolved by ammonia has been proved to influence membrane fouling most among the three silica sources. This was because the amount of silica dissolved by ammonia was the largest, and the polymerization of silica monomers at high concentration caused colloid particles formation, which led to a dense cake layer depositing on the membrane surface. Meanwhile, the size reduction of catalyst particles caused by alkaline dissolution also increased specific resistances of cake layers.展开更多
In order to study the interaction between various fouling particles and ballast,a multi-layer and multi-scale discrete element model(DEM)including the sleeper,ballast bed and the surface layer of subgrade was develope...In order to study the interaction between various fouling particles and ballast,a multi-layer and multi-scale discrete element model(DEM)including the sleeper,ballast bed and the surface layer of subgrade was developed.Two typical fouling particles,the hard particles(sand)and soft ones(coal fines),are considered.A support stiffness test of the ballast bed under various fouling conditions was conducted to calibrate the microscopic parameters of the contact model.With the model,the influence of fouling particles on the mechanical behavior and deformation of the ballast bed was analyzed from macro and micro perspectives.The results show that the increase in the strength of the fouling particles enlarges the stiffness of the ballast bed.Hard particles increase the uniformity coefficient of the contact force bondγof ballast by 50.4%.Fouling particles increase the average stress in the subgrade,soft particles by 2 kPa and hard particles by 1 kPa.Hard particles can reduce the elasticity,plastic deformation and energy dissipation in the track structure.As the fouling particle changes from hard to soft,the proportion of the settlement in ballast bed increases to 40.5%and surface layer of swbgrade settlement decreases to 59.5%.Thus,the influence of fouling particles should be considered carefully in railway design and maintenance.展开更多
Fouling resistance of ultrafiltration(UF) membranes is critical for their long-term usages in terms of stable performance, so convenient approaches to prepare fouling-resistant membranes are always anticipated. Herein...Fouling resistance of ultrafiltration(UF) membranes is critical for their long-term usages in terms of stable performance, so convenient approaches to prepare fouling-resistant membranes are always anticipated. Herein, we demonstrate the facile fabrication of antifouling polysulfone-block-poly(ethylene glycol)(PSF-b-PEG, SFEG)composite membranes. SFEG layer was coated onto macroporous supports and cavitated by immerging them in acetone/n-propanol following the mechanism of selective swelling induced pore generation. Thus-produced SFEG membranes possessed high permeance and excellent mechanical strength. Meanwhile, the structures and separation performances of the SFEG layers can be continuously tuned through simply changing swelling durations. More importantly, the hydrophilic PEG chains were spontaneously enriched onto the pore walls through swelling treatment, endowing intrinsic antifouling property to the SFEG membranes. Bovine serum albumin(BSA)/humic acid(HA) fouling tests proved the prominent fouling resistance of SFEG membranes, and the fouling resistance is expected to be long-standing because of the firm connection between PEG chains and PSF matrix by covalent bonding.展开更多
基金support for this research was provided by the National Natural Science Foundation of China(52339004 and 52209074)Natural Science Foundation of Shandong Province(ZR2022QE079),National Key Research and Development Plan(2021YFD1900900)+3 种基金the earmarked fund for CARS-03,and the China Post-doctoral Science Foundation(BX2021363 and 2022M713394)Sunny C.Jiang was supported by US National Science Foundation(CBET 2027306,CBET 2128480,and CBET 1806066)US Bureau of Reclamation(R21AC10079-00)US Environmental Protection Agency(EPA-G2021-STAR-A1 and 84025701).
文摘The increasing demand for wastewater treatment has become a notable trend for addressing global water scarcity.However,fouling is a significant challenge for wastewater distribution engineering systems.This study provides an approach using nanobubbles(NBs)to control fouling.The antifouling capacities of three types of NBs,six oxygen concentrations,and two application procedures(prevention and removal)are investigated.The results show that NBs effectively mitigate composite fouling—including biofouling,inorganic scaling,and particulate fouling—in comparison with the non-NBs group.More specifically,hydroxyl radicals generated by the self-collapse of NBs oxidize organics and kill microorganisms in wastewater.The negatively charged surfaces of the NBs transform the crystalline form of CaCO_(3)from calcite to looser aragonite,which reduces the likelihood of ion precipitation.Furthermore,the NBs gas-liquid interfaces act as gas"bridges"between colloidal particles,enhancing the removal of particles from wastewater.Lastly,although the NBs inhibit the growth of fouling,they do not significantly remove the already adhered fouling in non-NBs treated groups.This study anticipates that the application of NBs will address the significant fouling issue for various wastewater distribution engineering systems in order to meet the global challenge of sustainable water supplies.
基金Financial support from the National Natural Science Foundation of China (22022816 and 22078358)
文摘Fouling caused by excess metal ions in hard water can negatively impact the performance of the circulating cooling water system(CCWS)by depositing ions on the heat exchanger's surface.Currently,the operation optimization of CCWS often prioritizes short-term flow velocity optimization for minimizing power consumption,without considering fouling.However,low flow velocity promotes fouling.Therefore,it's crucial to balance fouling and energy/water conservation for optimal CCWS long-term operation.This study proposes a mixed-integer nonlinear programming(MINLP)model to achieve this goal.The model considers fouling in the pipeline,dynamic concentration cycle,and variable frequency drive to optimize the synergy between heat transfer,pressure drop,and fouling.By optimizing the concentration cycle of the CCWS,water conservation and fouling control can be achieved.The model can obtain the optimal operating parameters for different operation intervals,including the number of pumps,frequency,and valve local resistance coefficient.Sensitivity experiments on cycle and environmental temperature reveal that as the cycle increases,the marginal benefits of energy/water conservation decrease.In periods with minimal impact on fouling rate,energy/water conservation can be achieved by increasing the cycle while maintaining a low fouling rate.Overall,the proposed model has significant energy/water saving effects and can comprehensively optimize the CCWS through its incorporation of fouling and cycle optimization.
基金National Natural Science Foundation of China (21878102)
文摘A study on heat transfer performance by thermal fluid coupling simulation for the fouling in a shell-tube heat exchanger used in engineering was presented. The coupling simulation was performed in a fluid and solid domains under three different fouling conditions: fouling inside the tube, fouling outside the tube, and fouling inside the shell. The flow field, temperature, and pressure distributions in the heat exchanger were solved numerically to analyze the heat transfer performance parameters, such as thermal resistance. It is found that the pressure drop of the heat exchanger and the thermal resistance of the tube wall increase by nearly 30% and 20%, respectively, when the relative fouling thickness reaches 10%. The fouling inside the tube has more impact on the heat transfer performance of the heat exchanger, and the fouling inside the shell has less impact.
基金supports by National Key Research and Development Project(2018YFC1900800-5)National Natural Science Foundation of China(61890930-5,62021003,61903010 and 62103012)+1 种基金Beijing Outstanding Young Scientist Program(BJJWZYJH01201910005020)Beijing Natural Science Foundation(KZ202110005009 and 4214068).
文摘The membrane fouling phenomenon,reflected with various fouling characterization in the membrane bioreactor(MBR)process,is so complicated to distinguish.This paper proposes a multivariable identification model(MIM)based on a compacted cascade neural network to identify membrane fouling accurately.Firstly,a multivariable model is proposed to calculate multiple indicators of membrane fouling using a cascade neural network,which could avoid the interference of the overlap inputs.Secondly,an unsupervised pretraining algorithm was developed with periodic information of membrane fouling to obtain the compact structure of MIM.Thirdly,a hierarchical learning algorithm was proposed to update the parameters of MIM for improving the identification accuracy online.Finally,the proposed model was tested in real plants to evaluate its efficiency and effectiveness.Experimental results have verified the benefits of the proposed method.
基金supported by the government of India through DOD-OSTC program entitled‘Biofouling and Antifouling Organisms in the Gulf of Mannar,Southeast Coast of India’(No.DOD/11-MRDF/4/11/UNI/97/P-15)funding by the Department of Ocean Development(Ministry of Earth Sciences,Government of India)through project(No.DOD/11-MRDF/4/11/UNI/97/P-15)。
文摘In this research,an Underwater Biofouling Panel(UWBFP)system was erected for the qualitative and quantitative estimation of macro fouling organisms in the Gulf of Mannar.Forty-four biofoulers were identified from four types of selected test panels.Among these biofoulers,Amphibalanus amphitrite(Darwin,1854)was the dominant one.The concrete panel encouraged the highest barnacle density compared to the other panels.Three series of test panels were used to assess the seasonal density of biofouling communities.The overall variation in barnacle count in the seaward and shoreward sides of all these three series were tested.They were found to be significantly different from each other.The greater variations in the barnacle density observed in this study in A-series of test panels could be due to the lack of or absence of other foulers to compete within the fortnight.The Shannon-Wiener species diversity index showed the highest diversity in wood substratum among the three series with greater accumulation of different types of fouling organisms.Multivariate analyses were also performed to understand the seasonal variation as well as the settlement pattern on the different directions of test panels based on validated data.PCA showed a strong variability(PC1 between 70.8%and 98.6%variance)between the directions of the panels in connection with barnacle density.The shade plot and CAP analysis segregated the short-term A-series test panels from the long-term(B-and C-series)test panels.Hence,the output was helpful in understanding the recruitment status of various faunal resources involved in the biofouling processes.
基金supported by the open foundation of State Key Laboratory of Chemical Engineering (SKL–ChE–18B03)the Municipal Science and Technology Commission of Tianjin, China (2009ZCKFGX01900)。
文摘A liquid-solid circulating fluidized bed boiler is designed and built for visualization research by applying the fluidized bed heat transfer and fouling prevention technology to the water side of the boiler. Four types of engineering plastic particles with different physical properties are selected as the solid working media. The effect of particle types on the fluidization and distribution of particles in the boiler is investigated under different feedwater flow rates and amount of added particles by using the charge couple device image measurement and acquisition system. The results show that all kinds of particles can't be normally fluidized and accumulate in the drum at low amount of added particles and feedwater flow rate. The particles with great density and low sphericity are more likely to accumulate. The average solid holdup in the riser tubes increases with the increase in feedwater flow rate and the amount of added particles. The non-uniform degree of particle distribution in the riser tubes generally decreases with the increase in feedwater flow rate and the amount of added particles. The particles with small density and settling velocity have high average solid holdup in the riser tubes under close sphericity. In generally,the smaller the density and settling velocity, the more uniform the particle distribution in the riser tubes.Three-dimensional diagrams of the non-uniform degree of particle distribution in the riser tubes of the boiler are established.
文摘To investigate the fouling characteristics of the composite insulator surface under the salt fog environment,the FXBW-110/120-2 composite insulator was taken as the research object.Based on the field-induced charge mechanism,the multi-physical field coupling software COMSOL was used to numerically simulate the fouling characteristics,explored the calculation method of ESDD,and demonstrated its rationality.Based on this method,the pollution characteristics of the composite insulator under the pollution fog environment were studied,and the influence of wind speed,droplet size,and voltage type on the pollution characteristics of the composite insulator was analyzed.The results showed that:with the increase in wind speed,the amount of accumulated pollution of insulator increases in the range of droplet size,and the relationship between wind speed and accumulated pollution is approximately linear;at the same wind speed,the amount of accumulated pollution increases with the increase of droplet size under the action of DC voltage;when there is no voltage,the amount of dirt on the upper surface of the insulator is more than that on the lower surface,while it is the opposite under DC voltage.
基金supported by National Science Foundation of Huaihai Institute of Technology (No. KQ07102)Open Project Program of the Key Laboratory of Marine Bio-resources Sustainable Utilization, SCSIO, CAS (No. KK09001)
文摘Biofouling is an important factor that affects bivalve farming industry. Fouling organisms may reduce growth and survival rate of the cultured species. Fouler are often filter feeders, so they are potential competitors for food resource with the cultured species. The present study was conducted to measure the impact of fouling on food uptake and nutrient release in April, 2006 in Daya Bay near Guangzhou, China. Results showed that fouling organisms had significant effect on food uptake and nutrient release. The chlorophyll a uptake rate of fouled scallops was 7.53 / Lh ±1.416 / Lh in April, significantly higher than those of cleaned scallops, Le., 4.23 / Lh±2.744 / Lh. The consumption of total particulate matter by fouled scallops in April was 5.52 / Lh± 0.818 / Lh; the corresponding results for cleaned scallops are 2.49 / Lh ±0.614 / Lh Fouling increased ammonia release significantly. The ammonia release rate of fouled scallops was 33.81/Lh ±7.699 / Lh in April, while cleaned scallops released 2.46 / Lh ±0.511 / Lh ammonia. Phosphate uptake of fouled scallops was 2.01± 0.699 / Lh and cleaned scallops released phosphate 6.01 / Lh + 0.876 / Lh in April. There was not significant difference in nitrate consumption between fouled and cleaned scallops. According to the phytoplankton classification of input and output water samples, fouled scallops filtered more phytoplankton species than cleaned scallops. Therefore, this study showed that fouling contributed much to phytoplankton depletion and concentration increase of ammonia in water.
文摘This paper summarizes a nontoxic Anti-fouling coating utilizing capsaicin as an anti-fouling agent. The capsaicin constituent used in the coating has a rating from about 100 000 to about 1 500 000 Scoville Heat Units. The capsaicin is mixed with a silicon dioxide and then solubilized into a free-flowing homogeneous liquid oleoresin composition by adding a solvent to increase solubility and facilitate mixing. The oleoresin capsaicin liquid solution is mixed with a suitable corrosion resistant epoxy resin, which is then mixed with a hardening catalyst and applied to the surface to be treated.
基金This work was supported by the Natural Science Foundation of Shandong Province of China (No.Q2007B01).
文摘A dielectric analysis model for the fouling layer on the polyethersulfone composite ultrafiltration (UF) membrane and solution system, which consists of the solution, concentration polarization layer (CPL), and cake layer, was established by virtue of the interfacial polarization and the electrostatic field theory. The effect of some important parameters, such as the depth, conductivity of CPL, and cake layer, on the dielectric spectroscopy (or dielectric relaxation properties) of the UF system was discussed by the parameter sensitivity analysis and the dielectric measurement. The simulations indicate that the CPL can be created rapidly and the cake layer formation is the dynamic balance process of growth and erosion in the process of UF. The key factor affecting on the dielectric spectrum of UF system is the electrical properties of the CPL and the cake layer. In comparison to the results of dielectric measurement, the simulations indicate that the model proposed in this work is valid and reliable to some degree for describing and explaining the dielectric relaxation phenomenon in UF system. It is very important to further understand the fouling behavior of membrane surface and optimize the controlling techniques of membrane fouling in the process of UF.
文摘Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills.
基金Project supported by the Hi-Tech Research and Development Project(863) of China (No. 2002AA601130)the National Science and Technology Research Project (No, 2003BA808A17)
文摘The purpose of this study is to understand the effect and mechanism of preventing membrane fouling, by coagulation pretreatment, in terms of fractional component and molecular weight of natural organic matter (NOM). A relatively higher molecular weight (MW) of hydrophobic compounds was responsible for a rapid decline in the ultrafiltration flux. Coagulation could effectively remove the hydrophobic organics, resulting in the increase of flux. It was found that a lower MW of neutral hydrophilic compounds, which could remove inadequately by coagulation, was responsible for the slow declining flux. The fluxes in the filtration of coagulated water and supernatant water were compared and the results showed that a lower MW of neutral hydrophilic compounds remained in the supernatant water after coagulation could be rejected by a membrane, resulting in fouling. It was also found that the coagulated flocs could absorb neutral hydrophilic compounds effectively. Therefore, with the coagulated flocs formed on the membrane surface, the flux decline could be improved.
基金Project supported by the University Doctorial Research Foundation.Ministry of Education of China(No.20030141022).
文摘Aerobic granular sludge was cultivated adopting internal-circulate sequencing batch airlift reactor. The contradistinctive experiment about short-term membrane fouling between aerobic granular sludge system and activated sludge system were investigated. The membrane foulants was also characterized by Fourier transform infrared (FTIR) spectroscopy technique. The results showed that the aerobic granular sludge had excellent denitrification ability; the removal efficiency of TN could reach 90%. The aerobic granular sludge could alleviate membrane fouling effectively. The steady membrane flux of aerobic granular sludge was twice as much as that of activated sludge system. In addition, it was found that the aerobic granular sludge could result in severe membrane pore-blocking, however, the activated sludge could cause severe cake fouling. The major components of the foulants were identified as comprising of proteins and polysaccharide materials.
基金supported by the National Natural Science Foundation of China (No. 50578024)
文摘Two parallel membrane bioreactors (MBRs) were operated under different calcium dosages (168.5, 27 mg/L) to gain a better understanding of the mechanism of retarding membrane fouling by adding calcium. The results showed that the particle size of sludge flocs increased and the particle size distribution tended to be narrow at the optimum dosage (168.5 mg/L). Calcium was effective in decreasing loosely bound extracellular polymeric substances (LB-EPS) in microbial flocs and soluble microbial products (SMP) in the supernatant at the dosage of 168.5 mg/L by strengthening the neutralization and bridging of EPS with flocs. Furthermore, the amount of CODs and CODc decreased in both the mixed liquor and the fouling cake layer on the membrane surface. In order to compare the filtration characteristics of cake layers from the MBRs with the two calcium dosages, the specific cake resistance and the compressibility coefficient were measured. The specific cake resistance from the MBR with optimum dosage (168.5 mg/L) was distinctly lower than that with low dosage (27 mg/L). The compressibility coefficient of the cake layers under two dosages were respectively attained as 0.65, 0.91. Scanning electron microscopy (SEM) and three-dimensional confocal scanning laser microscope analysis (CLSM) images were utilized to observe the gel layer directly.
文摘In this study, the effect of zeolite powder addition on submerged membrane bioreactor (SMBR) on membrane permeability, and the removals for COD, NH3-N, TN were investigated. Through the parallel operation of control and test systems, it was found that the zeolite powder addition could alleviate the ultra-filtration membrane fouling and enhance the membrane permeability. On the basis of experimental investigations, a concept of "protection coating layer" was proposed to illustrate the phenomenon of UF membrane fouling. In addition, the removal for COD in test system was more stable, a little higher compared to the control system. Due to the combination of nitrification and ion exchange, a more excellent removal for NH3-N in test system was obtained regardless of influent NH3-N loading rate. It was also found that a mean 25% higher TN removal took place in the test system, and ion exchange and simultaneous nitrification and de-nitrification were analyzed to be main factors. During the stable operation period, the SOURs of test zeolite powder added sludge and control activated sludge were measured to be 75 mgO2/(gMLVSS, h) and 24 mgO2/(gMLVSS, h) respectively, it meant that the zeolite powder addition could enhance the microorganism activity significantly.
基金The National Natural Science Foundation of China (No. 50138020)
文摘Experimental and theoretical analysis were made on the natural humic acid removal and the membrane fouling of ultrafiltration (UF) with in-line coagulation. The results showed dissolved organic carbon (DOC) and UV254 removals by the UF with in-line coagulation at pH 7 were increased from 28% to 53% and 40% to 78% in comparison with direct UF treatment respectively. At the same time, the analysis of high performance liquid chromatography showed that UF with coagulation had significant improvement of removal of humic acid with molecular weights less than 6000 Da in particular. Compared to direct UF, the in-line coagulation UF also kept more constant permeate flux and very slight increase oftransmembrane pressure during a filtration circle. Two typical membrane fouling models were used by inducing two coefficients Kc and Kp corresponding to cake filtration model and pore narrowing model respectively. It was found that membrane fouling by pore-narrowing effect was effectively alleviated and that by cake-filtration was much decreased by in-line coagulation. Under the condition of coagulation prior to ultrafiltration at pH 7, the cake layer formed on the membrane surface became thicker, but the membrane filtration resistance was lower than that at pH 5 with the extension of operation time.
基金the National Key Basic Research Program of China (No. 2014CB238905)
文摘High-alkali species in coal are notorious for causing ash slagging and fouling incidents.In this paper,four high-alkali coals were individually subject to hydrothermal pretreatment(HTP),within a batch-type autoclave at 300 -C for 1 h,and the treated coals were analyzed,along with the oxygen-containing functional groups determined by Fourier transform infrared spectrometer(FT-IR).Then the alkali species and other components in the coal ash were quantified by X-ray fluorescence(XRF)for evaluating the ash slagging and fouling tendency.Apart from this,FactSage was adopted to simulate the occurrence and transformation of alkali species during coal thermal conversion ending at various temperatures.The findings indicate that the treated coals are superior to the parent ones in terms of certain remarkable changes via HTP.The moisture,oxygen and sulfur of the hydrothermally treated coals decline obviously,while the calorific value rises sharply.HTP could reduce the alkali species to less than 2%(%,by weight,equivalent to Na2O in dry ash),with a maximum removal ratio of 88.9%,lowering the ash slagging and fouling tendency.The proposed mechanism of HTP was that the alkali species in coal matrix became released due to the breakage of the coal functional groups and micropores during HTP.
基金Supported by the National Basic Research Program of China (2009CB623406), the National Natural Science Foundation of China (20806038), the Natural Science Foundation of Jiangsu Province (BK2008504), the National Science Foundation for Postdoctoral Scientists of China (20070421005) and Jiangsu Planned Projects for Postdoctoral Research Funds (0702020B).
文摘Ceramic ultrafiltration membranes were used to separate titanium silicalite-1 (TS-1) catalysts from the slurry of catalytic ammoximation of cyclohexanone to oxime. Silica was shown to have a great effect on membrane fouling in the alkaline environment of this system. In the ammoximation system, there are three main silica sources, which are residual silica on the catalyst particles surface during preparation, silica dissolved from TS-1 catalyst particles by ammonia solvent, and silica sol added into the reaction slurry to inhibit the dissolution erosion of the TS-1 catalyst. The silica dissolved by ammonia has been proved to influence membrane fouling most among the three silica sources. This was because the amount of silica dissolved by ammonia was the largest, and the polymerization of silica monomers at high concentration caused colloid particles formation, which led to a dense cake layer depositing on the membrane surface. Meanwhile, the size reduction of catalyst particles caused by alkaline dissolution also increased specific resistances of cake layers.
基金Project(51978045) supported by the National Natural Science Foundation of ChinaProject([2017]7) supported by Shenshuo Science and Technology Development Project,China。
文摘In order to study the interaction between various fouling particles and ballast,a multi-layer and multi-scale discrete element model(DEM)including the sleeper,ballast bed and the surface layer of subgrade was developed.Two typical fouling particles,the hard particles(sand)and soft ones(coal fines),are considered.A support stiffness test of the ballast bed under various fouling conditions was conducted to calibrate the microscopic parameters of the contact model.With the model,the influence of fouling particles on the mechanical behavior and deformation of the ballast bed was analyzed from macro and micro perspectives.The results show that the increase in the strength of the fouling particles enlarges the stiffness of the ballast bed.Hard particles increase the uniformity coefficient of the contact force bondγof ballast by 50.4%.Fouling particles increase the average stress in the subgrade,soft particles by 2 kPa and hard particles by 1 kPa.Hard particles can reduce the elasticity,plastic deformation and energy dissipation in the track structure.As the fouling particle changes from hard to soft,the proportion of the settlement in ballast bed increases to 40.5%and surface layer of swbgrade settlement decreases to 59.5%.Thus,the influence of fouling particles should be considered carefully in railway design and maintenance.
基金Supported by the National Natural Science Foundation of China(21776126)the National Basic Research Program of China(2015CB655301)+1 种基金the Natural Science Foundation of Jiangsu Province(BK20150063)partially supported by the Open Fund of State Key Laboratory of Separation Membranes and Membrane Processes(M1-201702).
文摘Fouling resistance of ultrafiltration(UF) membranes is critical for their long-term usages in terms of stable performance, so convenient approaches to prepare fouling-resistant membranes are always anticipated. Herein, we demonstrate the facile fabrication of antifouling polysulfone-block-poly(ethylene glycol)(PSF-b-PEG, SFEG)composite membranes. SFEG layer was coated onto macroporous supports and cavitated by immerging them in acetone/n-propanol following the mechanism of selective swelling induced pore generation. Thus-produced SFEG membranes possessed high permeance and excellent mechanical strength. Meanwhile, the structures and separation performances of the SFEG layers can be continuously tuned through simply changing swelling durations. More importantly, the hydrophilic PEG chains were spontaneously enriched onto the pore walls through swelling treatment, endowing intrinsic antifouling property to the SFEG membranes. Bovine serum albumin(BSA)/humic acid(HA) fouling tests proved the prominent fouling resistance of SFEG membranes, and the fouling resistance is expected to be long-standing because of the firm connection between PEG chains and PSF matrix by covalent bonding.