Low-NOX combustion retrofit is performed by adopting staged combustion technology for a 600 MW utility boiler with a four-corner tangential firing system. The emission data of NOX before and after retrofit are compare...Low-NOX combustion retrofit is performed by adopting staged combustion technology for a 600 MW utility boiler with a four-corner tangential firing system. The emission data of NOX before and after retrofit are compared and analyzed. The test results show that the emission concentration of NOX decreases obviously after the low-NOX retrofit. Additionally, the emission of NOX decreases by nearly 50% when the unit load is higher than 350 MW. It can also be concluded that the emission of NOX is influenced significantly by the amount of SOFA, the damper opening of auxiliary air, the differential pressure between the secondary air windbox and the furnace, and so on.展开更多
The paper describes numerical and experimental study on reduction of NO~ emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOx formation mechanism model,along w...The paper describes numerical and experimental study on reduction of NO~ emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOx formation mechanism model,along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.展开更多
In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) κ-...In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) κ-ε model and a new method for cell face velocity interpolation based on a non-staggered grid system are employed. To avoid peeudo-diffusion that is significant in modeling tangentially fired furnaces, attempts are made at improving the differential volume scheme. Some new developments on turbulent diffusion of particles are also taken into account.Thus, computational accuracy is improved substantially.展开更多
The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-...The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics(CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.展开更多
文摘Low-NOX combustion retrofit is performed by adopting staged combustion technology for a 600 MW utility boiler with a four-corner tangential firing system. The emission data of NOX before and after retrofit are compared and analyzed. The test results show that the emission concentration of NOX decreases obviously after the low-NOX retrofit. Additionally, the emission of NOX decreases by nearly 50% when the unit load is higher than 350 MW. It can also be concluded that the emission of NOX is influenced significantly by the amount of SOFA, the damper opening of auxiliary air, the differential pressure between the secondary air windbox and the furnace, and so on.
基金Supported by the National Science Foundation of Zhejiang Province.
文摘The paper describes numerical and experimental study on reduction of NO~ emissions in a 600 MW tangentially fired boiler furnace under different operating conditions. A simplified NOx formation mechanism model,along with the gas-particle multiphase flow model, is adopted. The prediction yields encouraging results as compared to experimental data.
基金Supported by the National Science Foundation of Zhejiang Province
文摘In this work, an Eulerian/Lagrangian approach has been employed to investigate numerically the flow characteristics, heat transfer and combustion in a tangentially fired furnace. The RNG (Re-normalization group) κ-ε model and a new method for cell face velocity interpolation based on a non-staggered grid system are employed. To avoid peeudo-diffusion that is significant in modeling tangentially fired furnaces, attempts are made at improving the differential volume scheme. Some new developments on turbulent diffusion of particles are also taken into account.Thus, computational accuracy is improved substantially.
文摘The control of 3-D temperature distribution in a utility boiler furnace is essential for the safe, economic and clean operation of pc-fired furnace with multi-burner system. The development of the visualization of 3-D temperature distributions in pc-fired furnaces makes it possible for a new combustion control strategy directly with the furnace temperature as its goal to improve the control quality for the combustion processes. Studied in this paper is such a new strategy that the whole furnace is divided into several parts in the vertical direction, and the average temperature and its bias from the center in every cross section can be extracted from the visualization results of the 3-D temperature distributions. In the simulation stage, a computational fluid dynamics(CFD) code served to calculate the 3-D temperature distributions in a furnace, then a linear model was set up to relate the features of the temperature distributions with the input of the combustion processes, such as the flow rates of fuel and air fed into the furnaces through all the burners. The adaptive genetic algorithm was adopted to find the optimal combination of the whole input parameters which ensure to form an optimal 3-D temperature field in the furnace desired for the operation of boiler. Simulation results showed that the strategy could soon find the factors making the temperature distribution apart from the optimal state and give correct adjusting suggestions.