期刊文献+
共找到11,236篇文章
< 1 2 250 >
每页显示 20 50 100
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
1
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode control Constant Power Load (CPL) current-Sensorless control Extended State Observer
下载PDF
RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER 被引量:6
2
作者 刘军 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第1期67-72,共6页
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple... A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters. 展开更多
关键词 high frequency switch ing INVERTERS hysteresis current control half bridge
下载PDF
Fault tolerant control of electric pitch control system based on single current detection
3
作者 李宏伟 付勃 +2 位作者 董海鹰 杨立霞 王睿敏 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2016年第1期63-70,共8页
In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is sing... In view of the current sensors failure in electric pitch system,a variable universe fuzzy fault tolerant control method of electric pitch control system based on single current detection is proposed.When there is single or two-current sensor fault occurs,based on the proposed method the missing current information can be reconstructed by using direct current(DC)bus current sensor and the three-phase current can be updated in time within any two adjacent sampling periods,so as to ensure stability of the closed-loop system.And then the switchover and fault tolerant control of fault current sensor would be accomplished by fault diagnosis method based on adaptive threshold judgment.For the reconstructed signal error caused by the modulation method and the main control target of electric pitch system,a variable universe fuzzy control method is used in the speed loop,which can improve the anti-disturbance ability to load variation,and the robustness of fault tolerance system.The results show that the fault tolerant control method makes the variable pitch control system still has ideal control characteristics in case of sensor failure although part of the system performance is lost,thus the correctness of the proposed method is verified. 展开更多
关键词 electric pitch control fault tolerant control variable universe fuzzy control single current detection
下载PDF
Design and analysis of dual-mode structure repetitive control based hybrid current regulation scheme for active power filters
4
作者 邹志翔 王政 程明 《Journal of Southeast University(English Edition)》 EI CAS 2013年第4期407-413,共7页
An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structu... An all-digital hybrid current regulation scheme for the single-phase shunt active power filter (APF) is presented. The proposed hybrid current control scheme integrates the deadbeat control and the dual-mode structure repetitive control (DMRC) so that it can offer superior steady-state performance and good transient features. Unlike the conventional schemes, the proposed scheme-based APF can compensate both the odd and the even order harmonics in grid. The detailed design criteria and the stability analysis of the proposed hybrid current controller are presented. Moreover, an improved structure which incorporates the proposed hybrid controller and the resonant controller for tracking specific order harmonics is given. The relationships between the resonant controller and different repetitive control schemes are discussed. Experimental results verify the effectiveness and advantages of the proposed hybrid control scheme. 展开更多
关键词 active power filter dual-mode structure repetitive control (DMRC) current control harmonic compensation resonant controller
下载PDF
Application of a Current and Voltage Mixed Control Mode for the New Fast Control Power Supply at EAST 被引量:4
5
作者 黄海宏 晏腾 王海欣 《Plasma Science and Technology》 SCIE EI CAS CSCD 2014年第4期420-423,共4页
A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magne... A feedback control system is needed to restrain plasma vertical displacement in EAST (Experimental Advanced Superconducting Toknmak). A fast control power supply excites active feedback coils, which produces a magnetic field to control the plasma's displacement. With the development of EAST, new demands on the new fast control power supply have led to an enhanced ability of fast response and output current, as well as a new control mode. The structure of cascaded and paralleled H-bridges can meet the demand of extended capacity, and digital control can reMize current and voltage mixed control mode. The validity of the proposed scheme is confirmed by experiments. 展开更多
关键词 EAST plasma vertical unstable displacement fast control power supply current and voltage mixed control mode
下载PDF
Effects of current waveform parameters during droplet transfer on spatter in high speed waveform controlled Short-circuiting GMAW 被引量:4
6
作者 吕小青 曹彪 +1 位作者 曾敏 黄增好 《China Welding》 EI CAS 2005年第2期121-124,共4页
Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been... Aim at improving the stability of the Short-circuiting Gas Metal Arc Welding (GMAW-S) process for the enhanced speed usage, effects of current waveform parameters during short-term on the welding stability have been investigated by experimental method. The welding power source used for the research is an inverter with a special current waveform control. It is shown that the spatter decreases at first then increases with each increase of the low current period, current increase rate and the maximum current limit. The test results are provided for welding of 1 mm and 3 mm mild steel at speed of 1.2 m/min. The stable GMA W-S process under high speed welding condition has been achieved by optimizing the parameters. 展开更多
关键词 gas metal arc welding short circuit arc current waveform control high speed welding SPATTER
下载PDF
Reaction Selectivity Improvement for Reduction of Nitrobenzene in a Packed-Bed Electrode Reactor under Periodic-Current Control 被引量:1
7
作者 丁平 杨晓勤 袁渭康 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1998年第4期44-51,共8页
Rectangular wave current control of the electrochemical reduction of nitrobenzene im-proves the selectivity for p-aminophenol(PAP) compared to direct current(d.c.) control at thesame average current density in a flow-... Rectangular wave current control of the electrochemical reduction of nitrobenzene im-proves the selectivity for p-aminophenol(PAP) compared to direct current(d.c.) control at thesame average current density in a flow-by packed-bed reactor.Optimal increase in PAP selectivitycan be obtained at about a frequency of 50Hz and a duty cycle of 0.2.A mathematical model isset up to incorporate the effects of mass transfer,hydrogen evolution and double layer charging,and is solved using the Duhamel’s superposition principle and the modified Crank-Nicolson methodwith the upwind scheme.The conventional d.c.control cases are also calculated for comparison.Calculations can be applied to predict the reaction results under periodic current and d.c.control,but both display the same trends compared to experimental data. 展开更多
关键词 NITROBENZENE ELECTROREDUCTION PACKED-BED ELECTRODE REACTOR PERIODIC current control
下载PDF
Energy-Based Current Control for Stabilizing a Flexible Electrodynamic Tether System 被引量:1
8
作者 Hao Wen Bensong Yu Dongping Jin 《Journal of Beijing Institute of Technology》 EI CAS 2017年第1期1-4,共4页
An energy-based controller of electric current is synthesized for the libration stabilization of an electrodynamic tether system,which consists of a relatively large main-satellite and a sub-satellite of much smaller ... An energy-based controller of electric current is synthesized for the libration stabilization of an electrodynamic tether system,which consists of a relatively large main-satellite and a sub-satellite of much smaller size.Two dynamic models with different levels of accuracy are considered in this work.First,a dumbbell model of the system is used for the controller design,which aims at damping injection on the libration motions via the real-time regulation of the electric current.Furthermore,the efficacy and performance of the proposed scheme are numerically verified by using a more complex multi-body model which accounts for not only the tether flexibility but also the attitude of the main-satellite. 展开更多
关键词 electrodynamic tether FLEXIBLE energy-based control current control
下载PDF
Online Learning Control for Harmonics Reduction Based on Current Controlled Voltage Source Power Inverters 被引量:2
9
作者 Naresh Malla Ujjwol Tamrakar +2 位作者 Dipesh Shrestha Zhen Ni Reinaldo Tonkoski 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第3期447-457,共11页
Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used t... Nonlinear loads in the power distribution system cause non-sinusoidal currents and voltages with harmonic components.Shunt active filters(SAF) with current controlled voltage source inverters(CCVSI) are usually used to obtain balanced and sinusoidal source currents by injecting compensation currents.However,CCVSI with traditional controllers have a limited transient and steady state performance.In this paper,we propose an adaptive dynamic programming(ADP) controller with online learning capability to improve transient response and harmonics.The proposed controller works alongside existing proportional integral(PI) controllers to efficiently track the reference currents in the d-q domain.It can generate adaptive control actions to compensate the PI controller.The proposed system was simulated under different nonlinear(three-phase full wave rectifier) load conditions.The performance of the proposed approach was compared with the traditional approach.We have also included the simulation results without connecting the traditional PI control based power inverter for reference comparison.The online learning based ADP controller not only reduced average total harmonic distortion by 18.41%,but also outperformed traditional PI controllers during transients. 展开更多
关键词 Adaptive dynamic programming(ADP) current controlled voltage source power inverter(CCVSI) online learning based controller neural networks shunt active filter(SAF) total harmonic distortion(THD)
下载PDF
Research on Pitch Control Strategies of Horizontal Axis Tidal Current Turbine 被引量:3
10
作者 WANG Bing-zhen HU Teng-yan +1 位作者 GUO Yi ZHANG Yuan-fei 《China Ocean Engineering》 SCIE EI CSCD 2020年第2期223-231,共9页
Based on blade element momentum theory and generator characteristic test,a dynamic simulation model of 150 kW horizontal-axis tidal current turbine was established.The matching of the dynamic characteristics between t... Based on blade element momentum theory and generator characteristic test,a dynamic simulation model of 150 kW horizontal-axis tidal current turbine was established.The matching of the dynamic characteristics between the turbine and generator under various current velocities is studied,and the influence of the pitch angle on the matching is analyzed.For the problem of maximum power output in case of low current speed and limiting power in high current speed,the relation between optimal pitch angle and output power is analyzed.On the basis of dynamic characteristic analysis,the variable pitch control strategy is developed.The performance of the turbine under various tidal conditions is simulated.The research results show that the designed controller enables the turbine to operate efficiently under the condition of low current speed,and achieve the goal of limited power at high current speed. 展开更多
关键词 tidal energy horizontal axis tidal current turbine(HATT) pitch control SIMULATION
下载PDF
Growth and passivation of aluminum etch tunnels at on-off controlling direct current in 6 wt.% HCI solution 被引量:1
11
作者 WANG Mei HE Yedong 《Rare Metals》 SCIE EI CAS CSCD 2008年第2期205-209,共5页
Growth and passivation of tunnels within Al foil by on-off controlling DC etching in 6 wt.% HCI solution has been investigated. It was found that, in a given etchant solution at a special temperature, the longest tunn... Growth and passivation of tunnels within Al foil by on-off controlling DC etching in 6 wt.% HCI solution has been investigated. It was found that, in a given etchant solution at a special temperature, the longest tunnel length was only a function of the turn-on interval of DC. The potential of Al foil broke at on-off controlling DC by the result from anode polarization curves and potential-time (E-t) responding curves. When DC was switched on, the potential increased abruptly over pitting potential, leading to nucleation of pits at the surface and the growth of tunnels at special length. When DC was switched off, the potential decreased rapidly to a passive value, leading to stoppage of nucleation and death of tunnels. By this way, the longest tunnel length can be controlled and a non-piercing layer can be obtained. Hence, etching of Al foil at this current is beneficial for maintaining a good mechanical strength. 展开更多
关键词 aluminum electrolytic capacitor tunnel length GROWTH PASSIVATION on-off controlling current
下载PDF
Model Predictive Current Control with Adaptive-adjusting Timescales for PMSMs 被引量:15
12
作者 Feng Niu Xi Chen +4 位作者 Shaopo Huang Xiaoyan Huang Lijian Wu Kui Li Youtong Fang 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期108-117,共10页
A model predictive current control(MPCC)with adaptive-adjusting method of timescales for permanent magnet synchronous motors(PMSMs)is proposed in this paper to improve the dynamic response and prediction accuracy in t... A model predictive current control(MPCC)with adaptive-adjusting method of timescales for permanent magnet synchronous motors(PMSMs)is proposed in this paper to improve the dynamic response and prediction accuracy in transient-state,while lessening the computational burden and improving the control performance in steady-state.The timescale characteristics of different parts of MPCC,such as signal sampling,prediction calculation,control output,model error correction,are analyzed,and the algorithm architecture of MPCC with multi-timescale is proposed.The difference between reference and actual speed,and the change rate of actual speed are utilized to discriminate the transient state of speed change and load change,respectively.Adaptive-adjusting method of control period and prediction stepsize are illustrated in detail after operation condition discrimination.Experimental results of a PMSM are presented to validate the effectiveness of proposed MPCC.In addition,comparative evaluation of single-step MPCC with fixed timescale and proposed MPCC is conducted,which demonstrates the superiority of proposed control strategy. 展开更多
关键词 Model predictive current control(MPCC) permanent magnet synchronous motor(PMSM) multi-timescale adaptive-adjusting method
下载PDF
Hybrid Predictive Control with Simple Linear Control Based Circulating Current Suppression for Modular Multilevel Converters 被引量:5
13
作者 Yuanxiang Sun Zhen Li Zhenbin Zhang 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期335-341,共7页
The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and compli... The modular multilevel converter(MMC)has become a promising topology for widespread power converter applications.However,an evident circulating current flowing between the phases will increase system losses and complicate the heatsink design.This paper proposes a novel hybrid model predictive control method for MMCs.This method utilizes an indirect structure MPC and a sorting algorithm to implement current tracking and capacitor voltages balancing,considerably resulting in reduced calculation burden.In addition,different from the conventional MPC solutions,we add a simple proportional-integral(PI)controller to suppress circulating current through modifying the submodule(SM)inserted number,which is parallel to the MPC loop.This hybrid control solution combines both advantages of MPC and linear control,evidently resulting in improved performance of circulating current.Finally,the MATLAB/Simulink results of an 11-level MMC system verify the effectiveness of the proposed solution. 展开更多
关键词 Circulating current suppression hybrid predictive control linear control modular multilevel converters.
下载PDF
Current Situation and Comprehensive Control Measures of Water Environment in the Chaohu Lake 被引量:1
14
作者 Hu Mingming Ma Jianhua Zhu Xi 《Meteorological and Environmental Research》 CAS 2016年第6期45-50,共6页
Based on the analysis of current situation of water environment in the Chaohu Lake,general ideas and measures of controlling the water environment were proposed. In respect of control ideas,controlling outbreaks of bl... Based on the analysis of current situation of water environment in the Chaohu Lake,general ideas and measures of controlling the water environment were proposed. In respect of control ideas,controlling outbreaks of blue-green algae should be as one of control goals; it is needed to combine reducing the quantity of blue-green algae with decreasing eutrophication level to make the decrease in the quantity of blue-green algae larger than their natural increase until outbreaks of blue-green algae are eliminated; all kinds of techniques should be combined closely,integrated and innovated,and corresponding safeguard measures should be adopted. In respect of control measures,controlling sources of pollution and intercepting pollutants are basic measures,of which improving sewage treatment capacity and standard greatly is a key measure,and actively controlling pollution from large-scale livestock and poultry breeding is one of main measures; rivers polluted heavily should be controlled,and using microorganisms to purify small and moderate rivers can be as one of preferred techniques; blue-green algae should be dredged deeply to reducing their quantity; water should be transferred from the Yangtze River to the Chaohu Lake or the Hauihe River to purify water bodies and increase environmental capacity; reed wetland should be restored on a large scale to increase vegetation coverage from 5% to 20%; dredging should be combined with the elevation of basement of restored reed wetland. 展开更多
关键词 The CHAOHU LAKE Water environment control measures current SITUATION China
下载PDF
Predictive current control system of PMSM based on LADRC 被引量:2
15
作者 Wang Xiaopeng Zhao Jun +1 位作者 Wang Bohui Li Baomin 《Journal of Southeast University(English Edition)》 EI CAS 2022年第3期227-234,共8页
For a permanent magnet synchronous motor(PMSM)model predictive current control(MPCC)system,when the speed loop adopts proportional-integral(PI)control,speed regulation is easily affected by motor parameters,resulting ... For a permanent magnet synchronous motor(PMSM)model predictive current control(MPCC)system,when the speed loop adopts proportional-integral(PI)control,speed regulation is easily affected by motor parameters,resulting in the inability to balance the system robustness and dynamic performance.A PMSM optimal control strategy combining linear active disturbance rejection control(LADRC)and two-vector MPCC(TV-MPCC)is proposed.Firstly,a mathematical model of a PMSM is presented,and the PMSM TV-MPCC model is developed in the synchronous rotation coordinate system.Secondly,a first-order LADRC controller composed of a linear extended state observer and linear state error feedback is designed to reduce the complexity of parameter tuning while linearly simplifying the traditional active disturbance rejection control(ADRC)structure.Finally,the conventional PI speed regulator in the motor speed control system is replaced by the designed LADRC controller.The simulation results show that the speed control system using LADRC can effectively deal with the changes in motor parameters and has better robustness and dynamic performance than PI control and similar methods.The system has a fast motor speed response,small overshoot,strong anti-interference,and no steady-state error,and the total harmonic distortion is reduced. 展开更多
关键词 permanent magnet synchronous motor(PMSM) two-vector model predictive current control linear active disturbance rejection control speed control system
下载PDF
Adaptive controller design based on input-output signal selection for voltage source converter high voltage direct current systems to improve power system stability 被引量:2
16
作者 Abdolkhalegh Hamidi Jamal Beiza +1 位作者 Ebrahim Babaei Sohrab Khanmohammadi 《Journal of Central South University》 SCIE EI CAS CSCD 2016年第9期2254-2267,共14页
An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is w... An input-output signal selection based on Phillips-Heffron model of a parallel high voltage alternative current/high voltage direct current(HVAC/HVDC) power system is presented to study power system stability. It is well known that appropriate coupling of inputs-outputs signals in the multivariable HVDC-HVAC system can improve the performance of designed supplemetary controller. In this work, different analysis techniques are used to measure controllability and observability of electromechanical oscillation mode. Also inputs–outputs interactions are considered and suggestions are drawn to select the best signal pair through the system inputs-outputs. In addition, a supplementary online adaptive controller for nonlinear HVDC to damp low frequency oscillations in a weakly connected system is proposed. The results obtained using MATLAB software show that the best output-input for damping controller design is rotor speed deviation as out put and phase angle of rectifier as in put. Also response of system equipped with adaptive damping controller based on HVDC system has appropriate performance when it is faced with faults and disturbance. 展开更多
关键词 input-output signal selection online adaptive damping controller nonlinear high voltage direct current power systemstability
下载PDF
Design of a Control Device for Synthetic Making Test Based on Pre-Arcing Current Detection and Phase Control 被引量:1
17
作者 Zhengyang ZHOU Minfu LIAO Xingming FAN 《Journal of Electromagnetic Analysis and Applications》 2009年第4期279-283,共5页
The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated vol... The synthetic making test has been widely used in evaluating the break ability of high-voltage circuit breaker. However, the test research and application are still inadequate, especially in the condition of rated voltage. According to the realistic conditions of test stations in China, a control device based on pre-arcing current detection and phase control is proposed in this paper. A sample of the control device made up of DSP TMS320LF2407A is fabricated, in which the CPLD MAX7064 is used to transmit signals for EMC design. It can be applied in full voltage synthetic making test at a level of 126kV/63kA. The test results show that, it is accurate to control the making phase of the applied voltage, whether the closing is demanded at voltage peak or zero. 展开更多
关键词 SYNTHETIC MAKING Test Pre-Arcing current PHASE control
下载PDF
The Current Status and Challenges Regarding Tuberculosis Infection Control in Health Care Facilities in China 被引量:3
18
作者 ZHAO Fei CHENG Jun +9 位作者 CHENG Shi Ming ZHANG Hui ZHAO Yan Lin ZHANG Can You HU Dong Mei FAN Hai Ying HUANG Fei QU Yan HE Guang Xue WANG Li Xia 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2015年第11期848-854,共7页
Health care facilities are a high-risk environment for generating and spreading respiratory infectious diseases such as tuberculosis (TB). The TB prevention and treatment staff in health care facilities are responsi... Health care facilities are a high-risk environment for generating and spreading respiratory infectious diseases such as tuberculosis (TB). The TB prevention and treatment staff in health care facilities are responsible for the identification, diagnosis, treatment, supervision, and management of TB patients . 展开更多
关键词 TB The current Status and Challenges Regarding Tuberculosis Infection control in Health Care Facilities in China
下载PDF
Flow separation control over an airfoil using continuous alternating current plasma actuator 被引量:1
19
作者 Jian-Guo Zheng 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期346-355,共10页
The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to re... The flow separation control over an NACA 0015 airfoil using continuous alternating current(AC)dielectric barrier discharge(DBD)plasma actuator is investigated experimentally and numerically.This work is intended to report some observations made from our experiment,to which little attention is paid in the previous studies,but which is thought to be important to the understanding of control of complex flow separation with AC DBD.To this end,the response of separated flow to AC plasma actuation is visualized through the time-resolved particle image velocimetry(PIV)measurement,whereas numerical simulation is carried out to complement the experiment.The flow control process at chord-based Reynolds number(Re)of 3.31×105 is investigated.It is found that the response of external flow to plasma forcing is delayed for up to tens of milliseconds and the delay time increases with angle of attack increasing.Also observed is that at the intermediate angle of attack near stall,the forced flow features a well re-organized flow pattern.However,for airfoil at high post-stall angle of attack,the already well suppressed flow field can recover to the massively separated flow state and then reattach to airfoil surface with the flow pattern fluctuating between the two states in an irregular manner.This is contrary to one’s first thought that the forced flow at any angles of attack will become well organized and regular,and reflects the complexity of flow separation control. 展开更多
关键词 dielectric barrier discharge plasma actuator alternating current plasma discharge flow separation flow control delayed response
下载PDF
An Adaptive Single Neural Control for Variable Step-Size P&O MPPT of Marine Current Turbine System 被引量:1
20
作者 LI Ming-zhu WANG Tian-zhen +1 位作者 ZHOU Fu-na SHI Ming 《China Ocean Engineering》 SCIE EI CSCD 2021年第5期750-758,共9页
Marine current energy has been increasingly used because of its predictable higher power potential.Owing to the external disturbances of various flow velocity and the high nonlinear effects on the marine current turbi... Marine current energy has been increasingly used because of its predictable higher power potential.Owing to the external disturbances of various flow velocity and the high nonlinear effects on the marine current turbine(MCT)system,the nonlinear controllers which rely on precise mathematical models show poor performance under a high level of parameters’uncertainties.This paper proposes an adaptive single neural control(ASNC)strategy for variable step-size perturb and observe(P&O)maximum power point tracking(MPPT)control.Firstly,to automatically update the neuron weights of SNC for the nonlinear systems,an adaptive mechanism is proposed to adaptively adjust the weighting and learning coefficients.Secondly,aiming to generate the exact reference speed for ASNC to extract the maximum power,a variable step-size law based on speed increment is designed to strike a balance between tracking speed and accuracy of P&O MPPT.The robust stability of the MCT control system is guaranteed by the Lyapunov theorem.Comparative simulation results show that this strategy has favorable adaptive performance under variable velocity conditions,and the MCT system operates at maximum power point steadily. 展开更多
关键词 marine current turbine system perturb and observe single neural control adaptive mechanism maximum power point tracking
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部