Purpose: Patient-specific quality assurance (PSQA) requires manual operation of different workstations, which is time-consuming and error-prone. Therefore, developing automated solutions to improve efficiency and accu...Purpose: Patient-specific quality assurance (PSQA) requires manual operation of different workstations, which is time-consuming and error-prone. Therefore, developing automated solutions to improve efficiency and accuracy is a priority. The purpose of this study was to develop a general software interface with scripting on a human interactive device (HID) for improving the efficiency and accuracy of manual quality assurance (QA) procedures. Methods: As an initial application, we aimed to automate our PSQA workflow that involves Varian Eclipse treatment planning system, Elekta MOSAIQ oncology information system and PTW Verisoft application. A general platform, the AutoFrame interface with two imbedded subsystems—the AutoFlow and the PyFlow, was developed with a scripting language for automating human operations of aforementioned systems. The interface included three functional modules: GUI module, UDF script interpreter and TCP/IP communication module. All workstations in the PSQA process were connected, and most manual operations were automated by AutoFrame sequentially or in parallel. Results: More than 20 PSQA tasks were performed both manually and using the developed AutoFrame interface. On average, 175 (±12) manual operations of the PSQA procedure were eliminated and performed by the automated process. The time to complete a PSQA task was 8.23 (±0.78) minutes for the automated workflow, in comparison to 13.91 (±3.01) minutes needed for manual operations. Conclusion: We have developed the AutoFrame interface framework that successfully automated our PSQA procedure, and significantly reduced the time, human (control/clicking/typing) errors, and operators’ stress. Future work will focus on improving the system’s flexibility and stability and extending its operations to other QA procedures.展开更多
This paper proposes a novel clamping device for leveling equipment mounted on offshore oil platform jacket,which solves the problem of leveling equipment clamping lifting force of more than 2000 tons.The main features...This paper proposes a novel clamping device for leveling equipment mounted on offshore oil platform jacket,which solves the problem of leveling equipment clamping lifting force of more than 2000 tons.The main features are that lifting force transmits to clamp claw through wedge force amplifier,embed the teeth of claw into the pile,and the embedded depth increases with the lifting force,resulting in a gravitational self-locking function.This theoretical model of clamping device was established,and the force and material characteristic were analyzed,and the feasibility of the theoretical model was verified by thin shell elastic-plastic stability theory and thin-walled structures theory.An experimental prototype of clamping device was produced to test gravity self-locking function and bearable leveling force.Compared with the theoretical model and the experimental results,it proved that the embedded clamping devices have gravitational self-locking function and can meet the need of actual leveling equipment.展开更多
In order to resolve the conflict between the limited resources of embedded devices and the growing amount of massive image data to be shown, a solution for fast images rendering in embedded devices is proposed and imp...In order to resolve the conflict between the limited resources of embedded devices and the growing amount of massive image data to be shown, a solution for fast images rendering in embedded devices is proposed and implemented. First, an improved algorithm of a multi-resolution file-pyramid construction which is used for the organization of massive image data is presented. Then, a strategy, adopting technologies such as view-dependent levels of detail, target-tiles quick search and tiles seamless connection, is presented for fast scheduling and viewing of images. The results show that compared with the solution of multi-scale image representations based on wavelet, the proposed solution can improve the rendering speed, and the rendering speed does not depend on the image size, though it increases some data storage space. And the proposed solution is suitable for embedded devices and friendly experience.展开更多
Conducting polymer polydimethylsiloxane (PDMS) is studied for the high performance electrode of organic electroluminescence devices. A method to prepare the electrode consisting of a SiC thin film and PDMS is invest...Conducting polymer polydimethylsiloxane (PDMS) is studied for the high performance electrode of organic electroluminescence devices. A method to prepare the electrode consisting of a SiC thin film and PDMS is investigated. By using ultra thin SiC films with different thicknesses, the organic electroluminescence devices are obtained in an ultra vacuum system with the model device PDMS/SiC/PPV/Alq3, where PPV is poly para-phenylene vinylene and Alq3 is tris(S-hydroxyquinoline) aluminium. The capacitance voltage (C - V), capacitance-frequency (C - F), current-voltage (I - V), radiation intensity-voltage (R - V) and luminance eFficiency-voltage (E - V) measurements are systematically studied to investigate the conductivity, Fermi alignment and devices properties in organic semiconductors. Scanning Kelvin probe measurement shows that the work function of PDMS/SiC anode with a 2.5-nm SiC over layer can be increased by as much as 0.28eV, compared to the conventional ITO anode. The result is attributed to the charge transfer effect and ohmic contacts at the interface.展开更多
文摘Purpose: Patient-specific quality assurance (PSQA) requires manual operation of different workstations, which is time-consuming and error-prone. Therefore, developing automated solutions to improve efficiency and accuracy is a priority. The purpose of this study was to develop a general software interface with scripting on a human interactive device (HID) for improving the efficiency and accuracy of manual quality assurance (QA) procedures. Methods: As an initial application, we aimed to automate our PSQA workflow that involves Varian Eclipse treatment planning system, Elekta MOSAIQ oncology information system and PTW Verisoft application. A general platform, the AutoFrame interface with two imbedded subsystems—the AutoFlow and the PyFlow, was developed with a scripting language for automating human operations of aforementioned systems. The interface included three functional modules: GUI module, UDF script interpreter and TCP/IP communication module. All workstations in the PSQA process were connected, and most manual operations were automated by AutoFrame sequentially or in parallel. Results: More than 20 PSQA tasks were performed both manually and using the developed AutoFrame interface. On average, 175 (±12) manual operations of the PSQA procedure were eliminated and performed by the automated process. The time to complete a PSQA task was 8.23 (±0.78) minutes for the automated workflow, in comparison to 13.91 (±3.01) minutes needed for manual operations. Conclusion: We have developed the AutoFrame interface framework that successfully automated our PSQA procedure, and significantly reduced the time, human (control/clicking/typing) errors, and operators’ stress. Future work will focus on improving the system’s flexibility and stability and extending its operations to other QA procedures.
文摘This paper proposes a novel clamping device for leveling equipment mounted on offshore oil platform jacket,which solves the problem of leveling equipment clamping lifting force of more than 2000 tons.The main features are that lifting force transmits to clamp claw through wedge force amplifier,embed the teeth of claw into the pile,and the embedded depth increases with the lifting force,resulting in a gravitational self-locking function.This theoretical model of clamping device was established,and the force and material characteristic were analyzed,and the feasibility of the theoretical model was verified by thin shell elastic-plastic stability theory and thin-walled structures theory.An experimental prototype of clamping device was produced to test gravity self-locking function and bearable leveling force.Compared with the theoretical model and the experimental results,it proved that the embedded clamping devices have gravitational self-locking function and can meet the need of actual leveling equipment.
基金The National Public Benefit Research Foundation of China (No. 201111013-02)
文摘In order to resolve the conflict between the limited resources of embedded devices and the growing amount of massive image data to be shown, a solution for fast images rendering in embedded devices is proposed and implemented. First, an improved algorithm of a multi-resolution file-pyramid construction which is used for the organization of massive image data is presented. Then, a strategy, adopting technologies such as view-dependent levels of detail, target-tiles quick search and tiles seamless connection, is presented for fast scheduling and viewing of images. The results show that compared with the solution of multi-scale image representations based on wavelet, the proposed solution can improve the rendering speed, and the rendering speed does not depend on the image size, though it increases some data storage space. And the proposed solution is suitable for embedded devices and friendly experience.
基金Supported by the Hunan Province Natural Science Foundation of China under Grant No 06JJ20034.
文摘Conducting polymer polydimethylsiloxane (PDMS) is studied for the high performance electrode of organic electroluminescence devices. A method to prepare the electrode consisting of a SiC thin film and PDMS is investigated. By using ultra thin SiC films with different thicknesses, the organic electroluminescence devices are obtained in an ultra vacuum system with the model device PDMS/SiC/PPV/Alq3, where PPV is poly para-phenylene vinylene and Alq3 is tris(S-hydroxyquinoline) aluminium. The capacitance voltage (C - V), capacitance-frequency (C - F), current-voltage (I - V), radiation intensity-voltage (R - V) and luminance eFficiency-voltage (E - V) measurements are systematically studied to investigate the conductivity, Fermi alignment and devices properties in organic semiconductors. Scanning Kelvin probe measurement shows that the work function of PDMS/SiC anode with a 2.5-nm SiC over layer can be increased by as much as 0.28eV, compared to the conventional ITO anode. The result is attributed to the charge transfer effect and ohmic contacts at the interface.