期刊文献+
共找到36,119篇文章
< 1 2 250 >
每页显示 20 50 100
Meta-analysis of the efficacy of volar plate internal fixation versus closed reduction and external fixation in the treatment of adult distal radius fractures
1
作者 CHEN Jian-ge ZHANG Hai-ning +4 位作者 ZHAO Hong-zhou LIU Ming-jun XING Jia-hui WANG Ping WANG Wei-min 《Journal of Hainan Medical University》 CAS 2023年第19期44-56,共13页
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ... Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority. 展开更多
关键词 Volar plate internal fixation Closed reduction External fixation PLASTER SPLINT Distal radius fracture Meta analysis
下载PDF
Selection of internal fixation method for femoral intertrochanteric fractures using a finite element method 被引量:6
2
作者 Jia-Xuan Mu Shi-Yang Xiang +1 位作者 Qing-Yu Ma Hai-Lun Gu 《World Journal of Clinical Cases》 SCIE 2021年第22期6343-6356,共14页
BACKGROUND Failure to fix unstable intertrochanteric fractures impairs return to daily activities.AIM To simulate five different internal fixation methods for unstable proximal femoral fractures.METHODS A three-dimens... BACKGROUND Failure to fix unstable intertrochanteric fractures impairs return to daily activities.AIM To simulate five different internal fixation methods for unstable proximal femoral fractures.METHODS A three-dimensional model of the femur was established from sectional computed tomography images,and an internal fixation model was established.Finite element analysis of the femur model was established,and three intertrochanteric fracture models,medial defect,lateral defect,and medial-lateral defects,were simulated.Displacement and stress distribution after fixation with a proximal femoral anti-rotation intramedullary nail(PFNA),integrated dual-screw fixation(ITN),PFNA+wire,PFNA+plate,and PFNA+wire+plate were compared during daily activities.RESULTS The maximum displacement and stress of PFNA and ITN were 3.51 mm/473 MPa and 2.80 mm/588 MPa for medial defects;2.55 mm/288 MPa and 2.10 mm/307 MPa for lateral defects;and 3.84 mm/653 MPa and 3.44 mm/641 MPa for mediallateral defects,respectively.For medial-lateral defects,reconstructing the medial side alone changed the maximum displacement and stress to 2.79 mm/515 MPa;reconstructing the lateral side changed them to 3.72 mm/608 MPa,when both sides were reconstructed,they changed to 2.42 mm/309 MPa.CONCLUSION For medial defects,intramedullary fixation would allow early low-intensity rehabilitation exercise,and ITN rather than PFNA reduces the risk of varus and cut-out;for lateral wall defects or weakness,intram-edullary fixation allows higher-intensity rehabilitation exercise,and ITN reduces the risk of varus.For both medial and lateral defects,intramedullary fixation alone will not allow early functional exercise,but locating lateral or medial reconstruction will.For defects in both the inner and outer sides,if reconstruction cannot be completed,ITN is more stable. 展开更多
关键词 Hip fractures fracture fixation Intramedullary Finite element analysis
下载PDF
Open reduction and internal fixation for radial head fractures: A prospective observational study 被引量:4
3
作者 Imran Khan Mangi Arslan Ahmed Abro +4 位作者 Muhammad Naveed Memon Shahjahan Siyal Naveed Khan Nouman Memon Muhammad Kazim Rahim Najjad 《Journal of Acute Disease》 2020年第4期166-169,共4页
Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to J... Objective: To evaluate the effect of open reduction and internal fixation on radial head fracture and assess the post-operative function. Methods: This prospective observational study was conducted from June 2016 to July 2017 at Liaquat National Hospital and Medical College, Karachi. Altogether, 28 patients with radial head and neck fractures were enrolled in our study. These patients were admitted to the hospital and their fractures were fixed with open reduction and internal fixation. Baseline information of the patients was collected, and patient-rated elbow evaluation scores were calculated. Results: Out of the 28 patients, 21 were male and 7 were female. Besides, 16 fractures were on the right side and 12 were on the left side and 17 involving the dominant hands. In addition, 8 patients had Mason type Ⅱ fracture and 20 had Mason type Ⅲ fracture. The mean age of patients was (31.0 ± 8.0) years, and the mean follow-up is (1.2 ± 0.5) years. The mean average patient-rated elbow evaluation scores were (27.64 ± 1.60) at 1-year follow-up. Conclusions:The majority of the patients who had radial head fractures and treated by open reduction and internal fixation have attained an excellent range of motion postoperatively. 展开更多
关键词 Radial head fractures Open reduction and internal fixation Functional outcome
下载PDF
Functional Outcomes of Traumatic Complex Acetabulum Fractures with Open Reduction and Internal Fixation: 200 Cases 被引量:3
4
作者 Keykhosro Mardanpour Mahtab Rahbar +2 位作者 Maryam Rahbar Nyosha Mardanpour Sourena Mardanpour 《Open Journal of Orthopedics》 2016年第12期363-377,共15页
Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We ana... Objective: Acetabular fractures are common injuries in Iran. We assess the functional outcome of open reduction and internal fixation management of displaced Complex acetabular fractures. Materials and Methods: We analyzed a case series of patients with open reduction and internal fixation (ORIF) for complex acetabular fractures. Two hundred patients (132 men, 68 women) in four age groups including with a mean age of 43.39 ± 6.18 years (range 20 - 59 years) and a mean follow-up of 82.34 ± 12.48 months (range 18 - 109 months) met the inclusion criteria. Functional outcome at final follow-up was graded assessed according to Harris score. Factors affecting were defined. Results: Anatomic reduction was achieved in 192 hips, imperfect in 8 and poor in none. Radiological outcome revealed excellent results in 128 (64%) hips, good in eight, fair in five and none in poor. Harris score were excellent in 139 (69.5%) hips, good in 43 (21.5%) and fair in 18 (9%) and poor in none. The anatomical reduction results had a favorable final functional outcome. (0.003) However, BMI (P Conclusion: Optimal functional and radiological outcomes have been achieved with anatomic postoperative reduction. Also experience of specialist, on time surgery and good recovery lead to receiving excellent functional outcome with at least complications. 展开更多
关键词 Complex Acetabular fracture internal fixation Open Reduction OUTCOME
下载PDF
Effects of bridge combined internal fixation system internal fixation on fracture healing and shoulder joint function in elderly patients with displaced midshaft clavicle fractures 被引量:1
5
作者 Wang Guang-Xin Xiao Wan-Jun +1 位作者 Wang Chen Liang Qing-Wei 《Journal of Hainan Medical University》 2019年第18期35-39,共5页
Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphaticall... Objective:To compare the clinical therapeutic effect of bridge combined internal fixation system and locking compression plate internal fixation in the treatment of displaced midshaft clavicle fractures by emphatically observing fracture healing and shoulder joint function.Methods:Totally 44 elderly patients with Robinson type 2B displaced midshaft clavicle fractures were included from the Department of Orthopaedics,Shenyang Fourth People's Hospital during February 2016 and December 2018,including 23 males and 21 females,mean age(69.8±10.2)years old.The patients were divided into a bridge combined internal fixation system group(bridge group,n=22)and a locking compression plate internal fixation group(plate group,n=22)according to the internal fixation methods.The operation time,intraoperative blood loss,fracture healing time,and postoperative complications were recorded.At 12 months after surgery,the shoulder joint Constant-Murley score and DASH score were used to assess the recovery of joint function.The serum levels of bone turnover biochemical markers procollagen I N-terminal peptide(P1NP),cross-linked Carboxy-terminal telopeptide of typeⅠcollagen(CTX-I),and osteoblast specific factor(OSF)were measured before and 3 months after surgery.Results:The operation time,intraoperative blood loss and fracture healing time of the bridge group were significantly shorter than those of the plate group(P<0.05).Constant scores and DASH scores in the bridge group were significantly better than those of the plate group at 12 months after surgery(P<0.05).Serum levels of CTX-I was significantly decreased,while the P1NP and OSF were significantly increased compared with before surgery in the both groups(P<0.05),and the changes were more obvious in the bridge group(P<0.05).The incidence of complications was similar between the two groups(P<0.05).Conclusion:Compared with the locking plate system,the bridge combined internal fixation system can effectively improve the operation efficiency,have more benefits on fracture healing,better promote the recovery of patients'function,and reduce the failure rate of internal fixation,thus providing a better choice to treat displaced midshaft clavicle fractures by intraoperative internal fixation. 展开更多
关键词 BRIDGE COMBINED internal fixation Locking plate old age Mid-clavicular displacement fracture internal fixation fracture healing shoulder function Bone turnover
下载PDF
Comparison of Clinical Effect of PFNA and Internal Fixation with Anatomical Locking Plate of Proximal Femur in Treatment of Intertrochanteric Fracture of Femur 被引量:1
6
作者 Lu Wanqing Xiang Qingtian +2 位作者 Yu Yajun Wang Chunhua Wang Jiafei 《Journal of Clinical and Nursing Research》 2018年第2期23-26,共4页
Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated... Purpose:To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods:The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results:The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion:The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal. 展开更多
关键词 INTERTROCHANTERIC fracture of FEMUR ANATOMICAL locking plate of PROXIMAL FEMUR PROXIMAL FEMORAL NAIL Antirotation internal fixation surgery Therapeutic effect
下载PDF
Modified Closed Reduction and Percutaneous Kirschner Wires Internal Fixation for Treatment of Supracondylar Humerus Fractures in Children 被引量:4
7
作者 Shu-bin WANG Bin-hui LIN +4 位作者 Wei LIU Guo-jun WEI Zong-guang LI Nai-chun YU Guang-rong JI 《Current Medical Science》 2021年第4期777-781,共5页
Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children... Objective Supracondylar humerus fractures are the most frequent fractures of the paediatric elbow.The present study introduced a modified surgical procedure for treatment of supracondylar humerus fractures in children.Methods From February 2015 to August 2019,73 patients with Gartland’s type II and III supracondylar fractures were treated with this modified method.Totally,68 of all patients were followed up for 3–12 months(mean 8.25 months).The evaluation results included fracture nonunion,ulnar nerve injury,pin track infection,carrying angle and elbow joint Flynn score.Results The results showed that bone union was observed in all children,one case had an iatrogenic ulnar nerve injury,and the symptoms were completely relieved in 4 months after removing of the medial-side pin.All children had no cubitus varus deformity and no pin track infection,and the rate of satisfactory results according to Flynn’s criteria score was 100%.Conclusion The modified closed reduction and Kirschner wires internal fixation could effectively reduce the rate of open reduction,the risk of iatrogenic ulnar nerve injury,and the incidence of cubitus varus deformity in treatment of supracondylar humerus fractures in children. 展开更多
关键词 supracondylar humerus fractures closed reduction Kirschner wires internal fixation surgical method
下载PDF
Clinical Effect of Posterior Internal Fixation and Fusion in the Treatment of Thoracolumbar Fractures 被引量:1
8
作者 Tianhui Liu Jianmin Cui 《Journal of Clinical and Nursing Research》 2021年第2期38-41,共4页
Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were ... Objective:To evaluate the clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures.Methods:36 patients with thoracolumbar fractures from January 2018 to December 2020 were selected and divided into study group and control group according to the random number table model.The control group was treated with anterior internal fixation,while the study group was treated with posterior internal fixation and fusion.The indexes of the two groups were compared and analyzed.Results:Compared with the operation related indexes of the two groups,the study group had more advantages(P<0.05);The postoperative kyphosis Cobb angle,height of anterior and posterior vertebral body,wedge index of the two groups were better than those before operation(P<0.05),and there was no significant difference between the two groups(P>0.05);There was no significant difference between the two groups(P>0.05).Conclusion:The clinical effect of posterior internal fixation and fusion in the treatment of thoracolumbar fractures is significant,and the body damage is slight,which is worthy of comprehensive promotion. 展开更多
关键词 Thoracolumbar fracture of spine The back road internal fixation and fusion
下载PDF
A Study of the Mechanical Characteristics of a Mandibular Parasymphyseal Fracture with Internal Fixation Device Subject to Variable Bite Forces: Finite Element Analysis
9
作者 Victor Caraveo Scott Lovald Tariq Khraishi 《Journal of Biosciences and Medicines》 2021年第4期158-178,共21页
In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element... In recent times, research into mandibular fracture has gained momentum from advances in scanning techniques, software/algorithm developments and improvements, and numerical structural modeling using the finite-element method (FEM). In this work, the FEM is used to model a mandibular fracture (using an inhomogeneous and orthotropic jaw model) simulating the effect of different bite tasks/forces on the stability of the fixated fracture. Specifically, bilateral and unilateral clenches (using muscle data) were studied using a low-profile 3D 4 × 2 hole mini-plate deployed for fracture fixation. Here, the mandible bone was treated as orthotropic and spatially inhomogeneous. Although the results of stress and displacement analyses, for this fixation hardware, indicate sufficient fixation under normal biting conditions, the results show that the unilateral and ipsilateral bites develop, in general, the highest stresses or displacements. Such results can guide post-surgery recommendation on bite behavior. 展开更多
关键词 MANDIBLE Mandibular fracture internal fixation Finite-Element Modeling Bite Forces
下载PDF
Internal fixation and unicompartmental knee arthroplasty for an elderly patient with patellar fracture and anteromedial osteoarthritis:A case report
10
作者 Shao-Kui Nan Hai-Feng Li +2 位作者 Dong Zhang Jian-Ning Lin Li-Sheng Hou 《World Journal of Clinical Cases》 SCIE 2021年第16期3919-3926,共8页
BACKGROUND Open reduction and internal fixation(ORIF)is the traditional surgical treatment for patellar fractures,and unicompartmental knee arthroplasty(UKA),especially Oxford UKA,has been increasingly used in patient... BACKGROUND Open reduction and internal fixation(ORIF)is the traditional surgical treatment for patellar fractures,and unicompartmental knee arthroplasty(UKA),especially Oxford UKA,has been increasingly used in patients with medial knee osteoarthritis(OA).However,the process of choosing treatment for patients with both patellar fractures and anteromedial knee OA remains unclear.We present the case of a patient with a patellar fracture and anteromedial OA.CASE SUMMARY We present the case of a 72-year-old woman with a history of bilateral medial compartment OA of the knees and a right Oxford UKA.She also experienced a recent left patellar fracture.ORIF and Oxford UKA were performed in a single stage.The patient showed excellent postoperative clinical results.CONCLUSION ORIF and Oxford UKA can be performed simultaneously for patients with patellar fracture and anteromedial OA on the same knee. 展开更多
关键词 Patellar fracture Anteromedial osteoarthritis Open reduction and internal fixation Unicompartmental knee arthroplasty Elderly patient Case report
下载PDF
Internal Fixation of Gunshot Induced Fractures in Civilians: Anatomic and Functional Results of a Standard Protocol at an Urban Trauma Center
11
作者 Anani Abalo Atsi Walla +3 位作者 Gamal Ayouba Yaovi Yannick Dellanh Kosivi Fortey Assang Dossim 《Open Journal of Orthopedics》 2016年第3期63-70,共8页
Introduction: Despite extensive experience with civilian gunshot fractures or wounds, no consensus exists on a standard protocol to manage these injuries. Many authors recommended immediate debridement, but the optima... Introduction: Despite extensive experience with civilian gunshot fractures or wounds, no consensus exists on a standard protocol to manage these injuries. Many authors recommended immediate debridement, but the optimal timing of internal fixation and the use of antibiotic have not been determined. The purpose of this paper is to present and discuss our experience. Material and methods: In January 2007, a treatment protocol was put in place for the evaluation and management of fractured extremities resulting from civilian gunshot wounds. Sixty-three patients with 64 fractures had been managed by this protocol for gunshot fractures between January 2005 and January 2012. There were 56 male and seven female. Their mean age was 33.1 years (range: 17 - 61 years). Thirteen patients (20.6%) were able to provide a description of the weapon. Only 15 patients had entry and exit wounds. The mean follow-up period was 27 (range, 20 - 58) months. The main factors assessed were the surgical site infection, the fracture union and the functional status. Results: Out of the 63 patients, 14 patients developed a wound infection (five superficial and seven deep infections). Wound infection was significantly associated with associated injuries (p = 0.0388), fractures sites requiring fixation (p = 0.024), the fracture pattern (p = 0.0412), operative modalities (p = 0.0400). There were nine cases (14.1%) of fracture non-union. The mean time to union was 15 weeks (range: 5 - 32 weeks). Five patients developed chronics osteomyelitis. The average SMFA score for all of the patients was 23.8 (range: 0 - 56.3). The mean dysfunctional and bother indexes were 18.3 (range: 0 - 52.7) and 22.6 (range: 0 - 66.1), respectively. The SMFA total score and dysfunction index had a significant correlation based on presence or absence of associated injuries (p < 0.0001). But bother index did not show the same correlation (p = 0.452). The average length of hospital stay was 11.3 days (range: 3 - 64). Conclusion: In civilian’s gunshot induced fractures, internal fixation can be made according to standard protocol, with acceptable result. 展开更多
关键词 fracture Gunshot fracture internal fixation Wound Infection Surgical Treatment
下载PDF
Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation
12
作者 高广升 李凤辉 《中国组织工程研究与临床康复》 CAS CSCD 2001年第24期154-155,共2页
关键词 Chinese traditional medicine rehabilitative treatment of femoral neck fracture after screw thread needle internal fixation TIME
下载PDF
Clinical Analysis of Minimally Invasive Single-segment Reduction and Internal Fixation in Patients with Thoracolumbar Fractures
13
作者 Sun Xiuchen 《Journal of Clinical and Nursing Research》 2018年第1期23-27,共5页
Objective:To study the clinical effect of minimally invasive single-segment reduction and internal fixation in patients with thoracolumbar fractures.Methods:From June 2013 to June 2014,100 patients with thoracolumbar ... Objective:To study the clinical effect of minimally invasive single-segment reduction and internal fixation in patients with thoracolumbar fractures.Methods:From June 2013 to June 2014,100 patients with thoracolumbar fractures were selected as the subjects and they were randomly divided into observation group(50 cases)and control group(50 cases).The patients in the observation group were treated with minimally invasive singlesegment reduction and internal fixation.The patients in the control group were treated with short segmental fixation.The clinical effects of the two groups were compared.Results:There was no significant difference in the compression rate and Cobb angle between the two groups before and after operation(P>0.05).For all patients who were followed up for the last time,the Cobb angle was significantly lower in the observation group than in the control group(P<0.05).The social function,affective function and physical pain score of the observation group were significantly better than the control group(P<0.05).The amount of bleeding in the observation group was(250.4±41.0)ml,which was significantly lower than that in the control group(267.5±32.8)ml.The time required for the operation was(90.2±35.4)min,which was significantly lower than that of the control group(104.5±22.6)min(P<0.05).After treatment,the prognosis was 70.00%and the excellent and good rate was 98.00%,which was significantly higher than that of the control group(46.00%)and 78.00%(P<0.05).Conclusion:Thoracolumbar fractures in patients with dilated channel minimally invasive single-segment reduction and internal fixation treatment can effectively repair the patient's vertebral height and Cobb angle and the degree of correction after surgery was significantly better,safer and worthy of clinical recommended use. 展开更多
关键词 THORACOLUMBAR fractureS DILATED channels MINIMALLY invasive SINGLE SEGMENT reduction internal fixation
下载PDF
Effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures
14
作者 Wen-Guang Fang Yang Lin +1 位作者 Li-Cheng Huang Gui-Zhong Du 《Journal of Hainan Medical University》 2019年第16期40-44,共5页
Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with R... Objective:To investigate the effect of locking compression plate internal fixation on the injury extent and bone metabolism of Robinson 2A and 2B middle clavicular fractures.Methods:Totally 80 cases of patients with Robinson 2A and 2B middle clavicular fractures admitted to our hospital between March 2017 and January 2019 were divided into the control group(n=41)receiving conventional kirschner wire internal fixation and the observation group(n=39)receiving locking compression plate internal fixation according to the operation plans.The differences in serum contents of inflammatory factors,oxidative stress indexes and bone metabolism indexes were compared between the two groups of patients before patients entered operating room,24 h after surgery and 48 h after surgery.Results:Before patients entered operating room,there were no statistically significant differences in the serum contents of inflammatory factors,oxidative stress indexes or bone metabolism indexes between the two groups(P>0.05).At 24 h and 48 h after surgery,serum inflammatory factors interleukin-1(IL-1),interleukin-17(IL-17),high-sensitivity C-reactive protein(hs-CRP)and tumor necrosis factorα(TNF-α)contents in the observation group were lower than those in the control group;serum reactive oxygen species(ROS)and lipid hydroperoxide(LHP)contents were lower than those in the control group,while catalase(CAT)and glutathione peroxidase(GSH-Px)contents were higher than those in the control group;serum N-terminal propeptide of procollagen type I(PINP),bone gla protein(BGP)and alkaline phosphatase(ALP)contents were higher than those in the control group,while N-telopeptide of typeⅠcollagen(NTX),C-telopeptide of typeⅠcollagen(CTX)and tartrate-resistant acid phosphatase 5b(TRACP5b)contents were lower than those in the control group(P<0.05).Conclusion:Locking compression plate internal fixation can reduce the postoperative trauma extent and help promote the fracture healing in patients with Robinson 2A and 2B middle clavicular fracture. 展开更多
关键词 MIDDLE clavicular fracture LOCKING compression plate internal fixation TRAUMA Bone METABOLISM
下载PDF
Comparison of Clinical Effect of PFNA and Internal Fixation with Anatomical Locking Plate of Proximal Femur in Treatment of Intertrochanteric Fracture of Femur
15
作者 Lu Wanqing Xiang Qingtian +2 位作者 Yu Yajun Wang Chunhua Wang Jiafei 《Journal of Clinical and Nursing Research》 2018年第3期7-9,共3页
Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated... Purpose To investigate the clinical value of proximal femoral nail antirotation and anatomical locking plate of proximal femur in the treatment of intertrochanteric fracture of femur.Methods The study group is treated with PFNA internal fixation.The control group is treated by internal fixation with anatomical locking plate of proximal femur.Results The time of operation,the amount of intraoperative bleeding and the time of fracture healing in the study group are significantly less than those in the control group.The incidence rate of complication in the study group(3.23%)is significantly lower than that in the control group(17.2%).Data comparison shows P<0.05.Conclusion The curative effect and prognosis for patients with intertrochanteric fracture of femur treated by PFNA internal fixation are more ideal. 展开更多
关键词 INTERTROCHANTERIC fracture of FEMUR ANATOMICAL locking plate of PROXIMAL FEMUR PROXIMAL FEMORAL NAIL Antirotation internal fixation surgery Therapeutic effect
下载PDF
MIPPO technique and LCP internal fixation for open tibial shaft fractures
16
作者 邹海兵 《外科研究与新技术》 2011年第2期107-107,共1页
Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 ca... Objective To explore the efficacy of minimally invasive percutaneous plate osteosynthesis (MIPPO) technique and locking compression plate (LCP) for open tibial shaft fractures.Methods From March 2005 to May 2009,16 cases with open tibial 展开更多
关键词 MIPPO technique and LCP internal fixation for open tibial shaft fractures LCP
下载PDF
Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
17
作者 马立泰 《外科研究与新技术》 2011年第2期106-106,共1页
Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 pat... Objective To explore the effects of the anterior internal fixation systems on the post-operative lateral angulation in treatment of thoracolumbar fractures.Methods A retrospective study was done to analyze the 172 patients who had 展开更多
关键词 Association between anterior internal fixation systems and post-operative lateral angulation in thoracolumbar fractures
下载PDF
Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C_3 type fracture
18
作者 李衡 《外科研究与新技术》 2005年第3期176-177,共2页
To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture usin... To assess the effect of using buttress plate associated with antografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture.Methods Seventeen cases of distal femoral C3 type fracture using buttress plate associated with antografting of fibula and iliac bone were analyzed retrospectively.Results All cases were followed up for an average of 24 months(8~55 months).The average time of octets bridge forming were 4 months(3~5 months) while the average time for bone union were 8 months (6~14 months).According to Shelbourne rating system,result of all 18 cases were excellent and no malunion,infection were found.Conclusion Buttress plate associated with antografting of fibula and iliac bone is an effective alternative for the treatment of distal femoral C3 type fracture.It can provide more stable fixation to the bone and earlier functional exercises can be achieved.5 refs,3 figs,1 tab. 展开更多
关键词 Usage of buttress plate internal fixation associated with autografting of fibula and iliac bone for the treatment of distal femoral C3 type fracture
下载PDF
Effect of AXIS lateral mass screw-plate internal fixation system on functional recovery of spinal cord in fracture of lower cervical vertebrae 被引量:4
19
作者 昌耘冰 尹庆水 +5 位作者 夏虹 吴增晖 徐国洲 张余 权日 章凯 《中国临床康复》 CSCD 2003年第6期998-999,T004,共3页
AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of... AIM:To evaluate the methods and results of the AXIS lateral mass screw plate system in the treating of lower cervical spine injury.METHODS:29 cases of lower cervical vertebrae injury were fixed with AXIS system.All of them were followed up for more than 1 year.RESULTS:All cases had a good bone union without malformation.We found no complication of the injury to the vertebral arteries or nerves.There was no loosening of the plate and screw. CONCLUSION:AXIS lateral mass screw plate system has the characteristic of stable,simple and safe and is suitable for the treatment of lower cervical spine injury. 展开更多
关键词 AXIS侧板钢板螺钉 内固定系统 下颈椎骨折脱位 颈髓功能恢复
下载PDF
Comparative study of various internal fixation methods for treating patellar fractures by three-dimensional photoelasticity 被引量:2
20
作者 许硕贵 苏佳灿 +4 位作者 张春才 曾伟明 顾绍德 张林春 方如华 《Journal of Medical Colleges of PLA(China)》 CAS 2003年第6期384-387,共4页
Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin thre... Objective: To compare the biomechanical basis of 3 different internal fixation methods: nitinol patellar concentrator (NT-PC), tension band and wire circle in treating patellar fractures. Methods: The epoxy resin three dimensional photoelasticity patellar models were made by precise moulding, and were fixated by nitinol patellar concentrator (NT-PC), tension band and wire circle respectively. The patellar models with frozen stress stripes were put into the polarized light field and the stress distributions were compared. As for the model fixated by NT-PC, by dividing layer, photographing and tracing, we used the iterative method to calculate the stress value of every internal node of the epoxy resin patellar model, and the character of stress was analyzed. Results: An overall stress field was yielded when the patellar model was fixated by NT-PC, and the stripes were more than that of tension band model and wire circle model, which have only few stress stripes in the fixated layers. Further analysis indicated that there were continuous fixated stresses in the facies articularis and distal pole of patella, and the character of stresses produced by NT-PC were mainly in longitudinal direction, then in transverse direction. The shearing stresses were small. Conclusion: The initiative and continuous memorial stress of NT-PC and its overall stress distribution character are the essence of NT-PC distinguished with tension band and wire circle in treating patellar fractures. The stress character produced by NT-PC is good for the stability of fracture site and prompts fracture healing. 展开更多
关键词 内固定 膝盖骨骨折 三维光弹性 镍钛合金膝盖骨集中器 张力带 生物力学
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部