Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emp...Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emphasizing the importance of a comprehensive approach for optimal outcomes. Case Presentation: This report presents the case of a 40-year-old motorcyclist who was involved in a road accident and arrived at the emergency department shortly after the incident. Clinical examination revealed closed fractures in both forearms with mild swelling and severe tenderness. Fortunately, no neurovascular issues or compartment syndrome were detected. The patient was administered intravenous fluids and effective pain relief. Forearm splints were applied and the arms were elevated using pillows. Radiographs showed fractures in the right distal radius and ulna, as well as the left mid-shaft radius and ulna. Under general anesthesia, open reduction and internal fixation were per-formed using plates and screws for all four fractures. Postoperatively, the patient’s arms were immobilized and elevated, with gradual recovery during follow-up appointments over six months, eventually achieving full function without complaints. Conclusion: This article highlights the possibility, although infrequent, of bilateral shaft fractures of the ulna and radius. With thorough clinical assessment and radiological investigation, such fractures can be well-defined. The required definitive treatment, which usually involves open reduction and internal fixation, can be performed.展开更多
Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically....Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial side.展开更多
Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine...Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine is a reliable method for the treatment of such fractures.It not only has good clinical efficacy,but also has fewer complications and high safety.However,the traditional small splint fixation does not cover the styloid process of the ulna,and the fracture of the styloid process of the ulna is closely related to the stability of the wrist joint,which has an important impact on the prognosis of the fracture.Based on this,we believe that the ulnar elongation splint can better improve the wrist function,and further prospects for related issues,in order to guide clinical practice.展开更多
BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with lon...BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.展开更多
Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The ...Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.展开更多
BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower lim...BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.展开更多
60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly intro...60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly introduced the diagnosis and treatment of a case of radius and ulna fracture in dog, with an attempt to provide reference for clinical practice.展开更多
BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reason...BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reasonable surgical planning and careful postoperative management can improve the prognosis of patients.CASE SUMMARY We report two cases of ulnar nerve injury subsequent to fracture of the distal radius.Both patients were admitted to hospital.Both patients had persistent ulnar nerve compression syndromes.The first patient achieved rapid recovery by early nerve decompression surgery,while the second patient had no recovery at 2-3 mo after injury and had more severe symptoms.At 10 wk after injury,the second patient agreed to nerve decompression surgery.The second patient finally achieved a successful outcome after nerve decompression and neurolysis,although she still has residual symptoms.CONCLUSION For patients with ulnar nerve compression syndrome related to acute wrist fracture,if symptoms persist and signs of recovery are not observed,early release is necessary to prevent permanent neurological damage.展开更多
Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)w...Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)with distal radius fractures were enrolled in this study.The patients were randomly divided into the treatment group and the control group.The treatment group was treated with manual reduction and small splints fixation.The control group was treated with manual reduction and resin plaster fixation.Before treatment,after reduction,and 3 months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length were recorded.Before treatment and 3 months after treatment,the Cooney wrist joint scores were recorded.The time of fracture healing and related adverse events during the treatment were recorded.Results:Before treatment and after reduction,there were no statistically significant differences between the two groups in palmar tilt angle,ulnar deviation angle,or radial length(P>0.05).Three months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length of the treatment group were better than those of the control group(P<0.05).The Cooney wrist scores of the treatment group was significantly higher than that of the control group three months after the treatment(P<0.05).The time of fracture healing of the treatment group was shorter than that of the control group,but the difference was no statistically significant(P>0.05).Conclusions:Compared with resin plaster fixation,traditional small splints fixation for distal radius fractures in older patients have the advantages of less loss of fracture reduction and faster functional recovery.Besides,the method is simple and low cost thus,it needs to be promoted.展开更多
Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes...Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.展开更多
<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Wheth...<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>展开更多
Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular ...Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular fractures(AO type C3)are relatively rare and account for about 5%of all distal radius fractures.[2]Fracture comminution at the joint surface is the primary manifestation of these fractures,followed by avulsion of the bone fragments with displacement seen at both the metacarpal and ulnar bone.Treatment of these displaced and unstable fractures remains a challenge.The nature of the articular surface fracture indicates the use of either the open or close reduction technique.Treatment protocols focus on extra-articular reduction and restoration of radial length,maintaining the volar tilt.[3,4]It has been noted that incongruity of the intra-articular distal radius fracture is relevant to the development of arthritis.[5,6]展开更多
Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius...Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.展开更多
Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-ti...Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-tification of factors affecting this loss of motion is of importance. This study was conducted to evaluate the relation between extraarticular distal radius fractures associated with fracture of ulnar styloid and the rota-tional movements of the wrist and forearm. Patients and methods: 47 patients with an extraarticular distal radius fracture were enrolled in a prospective case control study. The patients were visited in regular follow up intervals after treatment and at the final follow up the rotational movements of the forearm were measured. The findings were analyzed with Independent T and Chi-square tests. Findings: Ultimately 23 patients of the group 1 (intact ulnar styloid) and 24 of the group 2 (fractured ulnar styloid) completed the follow up period. At this time supination of the wrist and forearm in group 2 was significantly less than the group 1 (p< 0.001). Conclusion: It seems that the association of an extraarticular distal radius fracture with the fracture of ulnar styloid, at least in short term causes restriction of supination of the forearm, though the mechanism and clinical significance of this finding cannot be easily explained.展开更多
Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,...Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.展开更多
Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic...Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.展开更多
Forearm fractures are prevalent which include radius fractures,ulna fractures,or both radius and ulna fractures.Proximal radius fractures combined with dislocations of the radial heads are rare and easily misdiagnosed...Forearm fractures are prevalent which include radius fractures,ulna fractures,or both radius and ulna fractures.Proximal radius fractures combined with dislocations of the radial heads are rare and easily misdiagnosed.The authors present and discuss a case of proximal radius fractures associated with radial head dislocations.A 36 years old male was admitted to the hospital due to pain and activity limitation in his left elbow for 7 hours due to a car accident.An X-ray of the left elbow joint revealed a“left radius fracture with surrounding soft tissue edema”.During the procedure,the radial head was found to be dislocated forward.A 3.0 mm anchor was used to fix the annular ligament.Radius fractures combined dislocations of the radial heads are rare and may be missing the diagnosis.Before undergoing surgery,the possibility of elbow dislocation should be evaluated.Wire anchors can provide reliable fixation.展开更多
AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necess...AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n = 29), or another treatment modality(n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living(ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: Ⅱ.展开更多
AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations lear...AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS Twenty-six of the 382 internally fixed distal radial fractures at our unit(6.8%) were deemed to require this plate in order to achieve optimal fracture fixation between November 2011 and May 2014. A further dorsal and/or radial plate was necessary in 35% and variable angle screws were used in 54% of cases. Postoperatively, mean radial height, inclination, volar tilt and ulnar variance restored were 11.7 mm, 21o, 4.3o and-1.2 mm respectively. There were no cases of non-union or flexor/extensor tendon rupture; one case of loss of fracture reduction. Overall incidence of plate removal was 15% with one plate removed for flexor and one for extensor tendon irritation CONCLUSION The use of a rim plate enables control of challenging fardistal fracture patterns. However, additional plates were required to improve and maintain reduction. Variable angle screws were necessary in half the cases to avoid intra-articular screw penetration. If used judiciously, this implant can achieve stable fixation despite the complexity of the fracture pattern.展开更多
Objective: To investigate the application of artificial tiger bone powder on fracture healing time, wrist functional recovery and quality of life (QOL) in elderly patients with distal radius fracture. Methods: The stu...Objective: To investigate the application of artificial tiger bone powder on fracture healing time, wrist functional recovery and quality of life (QOL) in elderly patients with distal radius fracture. Methods: The study was a randomised controlled trials performed from January 2015 to December 2016 in a hospital. Elderly patients with distal radius fracture were divided into the treatment and the control groups by the random sealed envelope method. All patients were given splint or plaster fixation after manipulative reduction, and functional exercise, the treatment group was also given artificial tiger bone powder orally (trade name: Jintiange capsule), the control group was given an oral placebo in their appearance and usage identical with the treatment group. Prior to treatment and 6, 12 months after treatment, the wrist function was assessed by range of motion, including flexion-extension, radial-ulnar and pronation-supination, and the QOL was assessed by the Mos 36-item Short Form Health Survey. Each patient's fracture healing time was recorded. Results: Before treatment, there were no significant differences in wrist function and QOL between the two groups. At 6 and 12 months after treatment, the wrist function and QOL in the treatment group were better than those in the control group, the differences were statistically significant (P < 0.05). The fracture healing time in the treatment group was shorter than that of the control group, and the difference was statistically significant (P < 0.05). Conclusion: The early usage of artificial tiger bone powder for elderly patients with distal radius fracture can promote the healing of fracture, recovery of wrist joint function, and ultimately improve the QOL for elderly patients.展开更多
文摘Introduction: Forearm fractures involving both the radius and ulna, present distinctive challenges in orthopedic trauma management. This case report explores the complexities of a rare case of bilateral fractures, emphasizing the importance of a comprehensive approach for optimal outcomes. Case Presentation: This report presents the case of a 40-year-old motorcyclist who was involved in a road accident and arrived at the emergency department shortly after the incident. Clinical examination revealed closed fractures in both forearms with mild swelling and severe tenderness. Fortunately, no neurovascular issues or compartment syndrome were detected. The patient was administered intravenous fluids and effective pain relief. Forearm splints were applied and the arms were elevated using pillows. Radiographs showed fractures in the right distal radius and ulna, as well as the left mid-shaft radius and ulna. Under general anesthesia, open reduction and internal fixation were per-formed using plates and screws for all four fractures. Postoperatively, the patient’s arms were immobilized and elevated, with gradual recovery during follow-up appointments over six months, eventually achieving full function without complaints. Conclusion: This article highlights the possibility, although infrequent, of bilateral shaft fractures of the ulna and radius. With thorough clinical assessment and radiological investigation, such fractures can be well-defined. The required definitive treatment, which usually involves open reduction and internal fixation, can be performed.
文摘Background: Fracture of distal radius with involvement of the ulnar styloid process is a common clinical problem. It can be treated conservatively, usually involving wrist immobilization in plaster cast or surgically. A key method of surgical fixation is external fixation by distractor. Distractor can be applied either only on the radial side or on both ulnar and radial sides. Materials and Methods: A prospective randomized and comparative study of 1 year duration was conducted on 32 patients admitted in the Department of Orthopaedics of BSMC & H in the age group of 20 to 75 years old with AO types B and C distal radius fracture along with involvement of the ulnar styloid process. The parameters studied were restoration of radial length, restoration of radial angle, intracarpal step-off and palmar tilt which were statistically evaluated and Fisher’s exact test was performed. The two tailed P-value was calculated and both the groups were statistically compared. Results: In our study, 37.5% patients in Group A and 81.25% in Group B had a radial difference Table 1, Chart 1). 43.75% patients in Group A and 87.5% in Group B had radial angle Table 2, Chart 2). 31.25% in Group A and 75% had intra carpal step off Table 3, Chart 3). 62.5% had an abnormal palmar tilt in Group A while only 6.25% had an abnormal palmar tilt in Group B which is extremely statistically significant. On an average, 2 mm of distraction was required in 75% patients of Group A while only 30% patients in Group B required distraction (Table 4, Chart 4). Conclusion: In our study, the radial difference, radial angle, intra carpal step off and palmar tilt returned significantly to normal in the patients treated with distractor on radial side only when compared with distractor application on both radial and ulnar sides for distal radius fracture with ulnar styloid process involvement. Also post-operative distraction required under image intensifier was higher in the group treated with distractor on either side than those with distractor only on radial side.
基金This study was spoorted by the Project supported by Special Fund for Basic Scientific Research Business Fees of Central Level Public Welfare Scientific Research Institutes"Special Fund for Seedling Cultivation"(ZZ11-084).
文摘Objective:The incidence of distal radius fracture combined with ulnar styloid process fracture is increasing,which seriously affects the quality of life of patients.Small splint therapy of Traditional Chinese Medicine is a reliable method for the treatment of such fractures.It not only has good clinical efficacy,but also has fewer complications and high safety.However,the traditional small splint fixation does not cover the styloid process of the ulna,and the fracture of the styloid process of the ulna is closely related to the stability of the wrist joint,which has an important impact on the prognosis of the fracture.Based on this,we believe that the ulnar elongation splint can better improve the wrist function,and further prospects for related issues,in order to guide clinical practice.
文摘BACKGROUND Elderly patients maintaining functional independence can now be candidates for primary wrist hemiarthroplasty to manage acute irreparable distal radius fractures(DRFs).However,further investigation with long-term follow-up is required to validate these initial findings.AIM To review the literature on the outcomes of distal radius hemiarthroplasty with available implants to assess its viability as a treatment option.METHODS A comprehensive review of the literature was conducted using electronic databases,including PubMed,Medline,and Scopus.The search terms employed were"distal radius fracture","hemiarthroplasty","wrist arthroplasty",and related terminology.The search was restricted to articles published in English from 1980 until June 2023.Inclusion criteria encompassed cases or case series of DRF treated with hemiarthroplasty,providing clinical or radiographic outcomes,and published in peer-reviewed journals.RESULTS A total of 2508 articles from PubMed and 883 from Scopus were identified initially.Following screening and removal of duplicates,13 articles met the inclusion criteria.These articles,predominantly clinical retrospective studies,provided insights into hemiarthroplasty outcomes,including functional improvements and complications.Hemiarthroplasty was a treatment option for complex DRF,particularly those cases with severe comminution,intraarticular involvement,or severe osteoporosis.Functional outcomes demonstrated improvements in pain relief,wrist mobility,and grip strength,with variability across studies.Complications included implant loosening,infection,nerve injury,and stiffness,with varying incidence rates influenced by surgical techniques and implant choice.Long-term outcomes were inadequately documented,warranting further research.CONCLUSION Hemiarthroplasty is a promising treatment for irreparable DRF in the elderly.Long-term outcomes and complications require further study.
基金2022 Key Specialty Construction Project of Traditional Chinese Medicine:Traditional Chinese Orthopedics and Traumatology Department (No.962042)2020 Regional Traditional Chinese Medicine (Orthopedics and Traumatology)Diagnosis and Treatment Center (Jin Wei Zhong[2020]No.5)。
文摘Objective:To compare the efficacy of open reduction and volar locking plate internal fixation with closed reduction and external fixation in the treatment of distal radius fractures by using meta analysis.Methods:The databases of CNKI,Wanfang,Weipu,Chinese biomedical literature,Pubmed,Embase,and Cochrane Library were retrieved,and the randomized controlled studies that directly compared the efficacy of plate internal fixation and closed reduction external fixation in the treatment of distal radius fractures published publicly from the establishment of the database to April 2023 were collected.The two researchers independently screened the retrieved literature according to the inclusion and exclusion criteria,extracted data,used Cochrane risk bias assessment tool for quality assessment,and used RevMan 5.4 software for meta analysis.Results:A total of 10 randomized controlled trials were included,all of which were in English.There were 1042 patients in total,and 9 of them were rated as low risk.Meta analysis results showed that one year after the treatment of distal radius fracture with volar locking plate internal fixation,DASH score[MD=-5.64,95%CI(-7.21,-4.06),P<0.00001];One year later,PRWE score[MD=-5.90,95%CI(-8.88,-2.92),P=0.001];Palm flexion[MD=5.92,95%CI(1.29,10.55),P=0.01];Pronation[MD=2.48,95%CI(0.59,4.36),P=0.01];Postrotation[MD=4.73,95%CI(2.15,7.31),P=0.0003];Grip strength[MD=0.61,95%CI(0.12,1.10),P=0.02];palmar tilt angle[MD=9.84,95%CI(5.66,14.02),P<0.00001];Radial inclination[MD=4.33,95%CI(2.97,5.69),P<0.00001]was superior to closed reduction plaster or splint external fixation.One year later,the European Five dimensional Health Scale(EQ-5D-5L)score[MD=0.02,95%CI(-0.01,0.05),P=0.27];Back extension[MD=2.22,95%CI(-4.15,8.59),P=0.49];Ulnar deviation[MD=3.49,95%CI(-0.80,7.78),P=0.11];Radial deviation[MD=2.05,95%CI(-2.39,6.50),P=0.37];Ulnar variance[MD=-1.14,95%CI(-3.16,0.88),P=0.27];There was no significant difference in complications[MD=0.77,95%CI(0.54,1.10),P=0.16](P>0.05).Conclusion:Based on the current clinical data,internal fixation with volar locking plate is more conducive to mid-term DASH score and grip strength recovery than closed reduction plaster or splint external fixation,but there is no significant difference in the quality of life and complications of patients.For adult distal radius fractures,surgical indications should be carefully grasped,and non operative treatment should be given priority.
基金Shanghai Fengxian District Osteoarthropathy Clinical Diagnosis and Treatment Center,China,No.fxlczlzx-a-201704.
文摘BACKGROUND Pulmonary thromboembolism(PTE)is a serious postoperative complication that can occur after a fracture.Generally,PTE is caused by the falling off of lower extremity deep vein thrombosis(LEDVT)after lower limb fracture surgery.LEDVT and PTE after upper extremity fracture surgery are very rare.PTE is one of the most common clinical causes of sudden death.Venous thromboembolism includes PTE and DVT.We experienced one case of LEDVT and PTE after distal ulna and radius fracture surgery.The purpose of our report is to raise awareness for orthopedic surgeons that PTE can occur after distal ulna and radius fracture surgery,and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.CASE SUMMARY We report a 51-year-old Chinese male who had severe fractures of the left distal ulna,radius and little finger after a motorcycle accident.The patient underwent external fixation,open reduction and internal fixation.On the third post-operative day,computed tomographic pulmonary angiography showed PTE.Doppler ultrasonography showed thrombus formation in the bilateral posterior tibial veins.After a period of anticoagulation therapy,on the 25th d after the PTE,computed tomographic pulmonary angiography showed that thrombus in both sides of the pulmonary artery disappeared.Furthermore,about 4 mo after the PTE,thrombosis in the deep veins of the lower limbs disappeared.About 1 year after the surgery,X-rays showed good fracture healing,and the function of the wrist joint recovered well.CONCLUSION Though rare,PTE can occur after distal ulna and radius fracture surgery and patients with high risk factors should be considered for prevention and treatment of thrombosis in a timely manner.
基金Supported by Top-notch Academic Programs Project of Jiangsu Higher Education Institutions(PPZY2015C230)
文摘60% of a dog's body weight is supported by its fore limbs, while the hind limbs mainly play the role of power, so the probability of dog's radius and ulna fracture is greatly increased. This paper mainly introduced the diagnosis and treatment of a case of radius and ulna fracture in dog, with an attempt to provide reference for clinical practice.
文摘BACKGROUND Ulnar nerve injury subsequent to a fracture of the distal radius is extremely rare compared to median nerve injury.Treatment of ulnar nerve injury after closed distal radial fracture is controversial.Reasonable surgical planning and careful postoperative management can improve the prognosis of patients.CASE SUMMARY We report two cases of ulnar nerve injury subsequent to fracture of the distal radius.Both patients were admitted to hospital.Both patients had persistent ulnar nerve compression syndromes.The first patient achieved rapid recovery by early nerve decompression surgery,while the second patient had no recovery at 2-3 mo after injury and had more severe symptoms.At 10 wk after injury,the second patient agreed to nerve decompression surgery.The second patient finally achieved a successful outcome after nerve decompression and neurolysis,although she still has residual symptoms.CONCLUSION For patients with ulnar nerve compression syndrome related to acute wrist fracture,if symptoms persist and signs of recovery are not observed,early release is necessary to prevent permanent neurological damage.
基金supported by scientific research project of China National Medicine Association(2019KYXM-Z199-35).
文摘Objective:To investigate the effect of manual reduction with traditional small splints fixation for distal radius fractures in older patients in the emergency department.Methods:Older patients(aged at least 60 years)with distal radius fractures were enrolled in this study.The patients were randomly divided into the treatment group and the control group.The treatment group was treated with manual reduction and small splints fixation.The control group was treated with manual reduction and resin plaster fixation.Before treatment,after reduction,and 3 months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length were recorded.Before treatment and 3 months after treatment,the Cooney wrist joint scores were recorded.The time of fracture healing and related adverse events during the treatment were recorded.Results:Before treatment and after reduction,there were no statistically significant differences between the two groups in palmar tilt angle,ulnar deviation angle,or radial length(P>0.05).Three months after treatment,the palmar tilt angle,ulnar deviation angle,and radial length of the treatment group were better than those of the control group(P<0.05).The Cooney wrist scores of the treatment group was significantly higher than that of the control group three months after the treatment(P<0.05).The time of fracture healing of the treatment group was shorter than that of the control group,but the difference was no statistically significant(P>0.05).Conclusions:Compared with resin plaster fixation,traditional small splints fixation for distal radius fractures in older patients have the advantages of less loss of fracture reduction and faster functional recovery.Besides,the method is simple and low cost thus,it needs to be promoted.
文摘Background: There is a large assortment of modalities for the surgical treatment/management of distal radius fractures (DRFs), where the most widely used is the fixed-angle volar plating (VLP) system, which, sometimes, is referred to as the “surgical modality of choice”. While outcomes with each modality are usually good to excellent, each has its share of shortcomings and complications. Thus, there is scope for improvements to existing modalities and/or introduction of new ones. Study Purpose: We introduce a novel modality, namely, the prototype of an intramedullary injectable bioresorbable polymer-bioresorbable balloon osteosynthesis (IPBO) system, and investigated its plausibility. Experimental Procedures: The biomechanical performance of a construct comprising a synthetic distal radius (fourth-generation Sawbones?) on which a simulated fracture was created (4-mm wide osteotomy positioned 25 mm from the most distal end of the radius) and fixated with a placement of the IPBO system (SIPBO Construct) was compared to that when the fixation was with an approved Ti-6Al-4V alloy VLP system (SVLP Construct), under a clinically-relevant compressive loading protocol. Performance involved determination of quantitative parameters of the construct (initial longitudinal stiffness (ICLS), final longitudinal stiffness (FCLS), and load-to-failure (Pf)) and observation and recording of features of the construct at the fracture point. We also determined the quantitative parameters for the intact synthetic distal radius (control). Results: For each of the quantitative parameters, the range of values for SIPBO Construct was within that for SVLP Construct, suggesting that the IPBO System is a plausible modality. Also, for SIPBO Construct, failure occurred within the polymer zone, whereas, for SVLP Construct, some failure features were fracture of the cortical wall and of the dorsal proximal fragments. Conclusion: The findings suggest that the IPBO system is plausible. As such, it merits further study;for example, determination of the influence of fracture gap fill ratio (defined as the proportion of the fracture gap that is filled by the expanding balloon as the polymer is injected into the balloon) on a large collection of quantitative biomechanical parameters.
文摘<b><span>Background:</span></b><span> Distal radius fracture surgery is performed under general (GA) or regional anesthesia with brachial plexus block (NB). </span><span>Whether anesthesia type affects patient outcomes is unclear. </span><span>This study retrospectively compared patient satisfaction between GA and NB after surgery. </span><b><span>Methods: </span></b><span>This was a historical cohort study of 80 (34 GA and 46 NB) patients who underwent volar plate fixation of distal radius fractures. Propensity score analysis was used to generate a set of matched cases (NB) and controls (GA), yielding 14 matched patient-pairs. The simplified patient satisfaction scale was compared for primary outcomes. Secondary outcomes were anesthesia and surgery duration, hospital stay length, adverse events, postoperative analgesic requirement, and wrist range of motion (ROM) 2 weeks and 3 months postoperatively.</span><span> </span><b><span>Results:</span></b><span> After propensity score matching, patients in almost all cases in both groups were “Satisfied” (effect size: 0.1, p</span><span> </span><span>=</span><span> </span><span>0.572), indicating little significant difference. Significant differences in adverse events and postoperative analgesic use observed before matching disappeared after matching. Anesthesia duration and hospital stay length were significantly shorter in the NB group (effect size: </span><span>-</span><span>1.27 and </span><span>-</span><span>0.77, p</span><span> </span><span>=</span><span> </span><span>0.00074 and p</span><span> </span><span>=</span><span> </span><span>0.0388, respectively), as was surgery duration (effect size: </span><span>-</span><span>0.84, p</span><span> </span><span>=</span><span> </span><span>0.0122) after matching. Similar to before matching, wrist ROM significantly improved in the NB group (effect size: 1.11, p</span><span> </span><span>=</span><span> </span><span>0.0279) in the early postoperative period, but the difference disappeared at 3 months postoperatively.</span><span> </span><b><span>Conclusions:</span></b><span> Patient satisfaction between distal radius fracture surgery under GA and NB was similar. Nerve block could help shorten hospital stay length and surgery duration and improve postoperative functional recovery.</span>
文摘Distal radius fracture is the most common fracture site of the human skeleton[1]and often occurs in young people resulting from high energy injury caused by severe trauma.However,complex distal radial intra-articular fractures(AO type C3)are relatively rare and account for about 5%of all distal radius fractures.[2]Fracture comminution at the joint surface is the primary manifestation of these fractures,followed by avulsion of the bone fragments with displacement seen at both the metacarpal and ulnar bone.Treatment of these displaced and unstable fractures remains a challenge.The nature of the articular surface fracture indicates the use of either the open or close reduction technique.Treatment protocols focus on extra-articular reduction and restoration of radial length,maintaining the volar tilt.[3,4]It has been noted that incongruity of the intra-articular distal radius fracture is relevant to the development of arthritis.[5,6]
文摘Objectives: This study compared the clinical and radiological outcomes of two different methods for the treatment of distal radial intra-articular fractures. Patients and Methods: Forty-six patients with distal radius intra-arti-cular fractures were divided into two groups. Group I included 24 patients with type C fracture treated by external fixator augmented by percutaneous K-wires. Group II included 22 patients with type C fracture treated by volar locked distal radial plate augmented by K-wires. Two patients had complex injuries necessitating double plating (sandwich). All patients were evaluated clinically by Mayo Wrist Score and radiologically by Sarmiento’s radiological score. Results: Both groups reported good personal satisfaction according to Mayo Wrist Score, and the results were not statistically different between the two groups. In Group I, 19 patients (79.2%) had excellent radiological outcome and five patients (20.9%) had good radiological outcome according to Sarmiento’s radiological score. In Group II, 20 patients (90.9%) had excellent outcome, and two (9.1%) had good radiological outcome;there was no or insignificant deformity. Conclusions: Complex distal radial fractures can be treated either by external fixation (ligamentotaxis) or by locked pre-contoured plating. The clinical outcome of plating and external fixator in our study did not show any statistically significant difference. The radiological outcome had no correlation with the clinical outcome.
文摘Introduction: Since distal radius fractures are among the most common fractures encountered in orthopedics and one of their common complications is restriction of rotational movements of the wrist and forearm, iden-tification of factors affecting this loss of motion is of importance. This study was conducted to evaluate the relation between extraarticular distal radius fractures associated with fracture of ulnar styloid and the rota-tional movements of the wrist and forearm. Patients and methods: 47 patients with an extraarticular distal radius fracture were enrolled in a prospective case control study. The patients were visited in regular follow up intervals after treatment and at the final follow up the rotational movements of the forearm were measured. The findings were analyzed with Independent T and Chi-square tests. Findings: Ultimately 23 patients of the group 1 (intact ulnar styloid) and 24 of the group 2 (fractured ulnar styloid) completed the follow up period. At this time supination of the wrist and forearm in group 2 was significantly less than the group 1 (p< 0.001). Conclusion: It seems that the association of an extraarticular distal radius fracture with the fracture of ulnar styloid, at least in short term causes restriction of supination of the forearm, though the mechanism and clinical significance of this finding cannot be easily explained.
基金Special Project for Seedling Cultivation funded by Special Fund of Chinese Central Government for Basic Scientific Research Operations in Commonweal Research Institutes(No.ZZ11-084)。
文摘Objective:Evaluate the efficacy,safety and economy of small splints and plate in the treatment of distal radius fractures(DRFs).Methods:Seven electronic databases,including PubMed,EMBASE,Cochrane Library,sinomed,CNKI,VIP and Wanfang,were searched for the original study.Literature was screened according to the inclusion and exclusion criteria,and the methodological quality of the included studies was evaluated by Cochrane risk bias assessment tool.The software Revman 5.4 was used for data analysis.Results:A total of 19 studies were included in the study.The clinical effective rate of the plate group[RR=0.96,95%CI(0.93,0.99),P=0.007],Radial inclination[MD=-1.85,95%CI(-2.93,-0.77),P=0.0008],Ulnar inclination[MD=-2.49,95%CI(-3.95,-1.04),P=0.0007],relative height of radius[MD=-1.63,95%CI(-2.40,-0.86),P<0.0001]were better than those in small splints group.There was no significant difference in fracture healing time[MD=-4.39,95%CI(-9.07,0.28),P=0.07]and complications[RR=1.57,95%CI(0.98,2.52),P=0.06]between the two groups.In terms of treatment cost[MD=-2.83,95%CI(-3.37,-2.30),P<0.00001],the small splint group was better than the plate treatment group.Conclusion:Compared with small splints therapy,plate internal fixation has advantages in clinical effective rate and imaging scores.There is no significant difference in fracture healing time and complications between the two groups.In terms of treatment cost,small splint therapy is better than plate therapy.Clinical treatment should be selected and formulated according to the individual situation,demands and clinical practice of patients.
文摘Background: AO type C3 distal radius fracture (DRF) is the most difficult-to-treat fracture type because of a tendency to shorten and collapse. The purpose of this study is to investigate the clinical and radiographic outcomes of comminuted intra-articular DRFs treated with a dynamic external fixator combined with a volar locking plate (VLP). Methods: Eleven patients (mean age, 61 years) with comminuted intra-articular DRFs were treated with a dynamic type of external fixator combined with a VLP. Following reduction and fixation with a VLP, the dynamic external fixator was applied and the distal ball joint of the fixator was aligned with the lunate-capitate line. The ball joint was unlocked approximately 2 weeks after surgery to allow wrist mobilization. The fixator was removed 3 - 6 weeks (mean, 5 weeks) after surgery. Consequently, clinical and radiographic assessments were carried out at the final follow-up. Results: At the final follow-up, the mean range values of wrist extension and flexion were 76°and 64°, respectively. Compared with the contralateral side, the mean grip strength was 84%. The mean Modified Mayo Wrist Score and the Disabilities of the Arm, Shoulder and Hand score were 88 and 9, respectively. No significant differences in the radiographic parameters exist between after surgery and final follow-up. Conclusions: This study indicated that the dynamic wrist fixator combined with a VLP is effective for the treatment of AO type C3 DRFs.
基金The authors acknowledge the financially support received from the Medicine and Health Project of Zhejiang Province(2022KY1288,2022KY1313)General Research Project of Zhejiang Provincial Department of Education(LY202043116,Y202145976)Science and Technology Project of Shaoxing City(2020A13011).
文摘Forearm fractures are prevalent which include radius fractures,ulna fractures,or both radius and ulna fractures.Proximal radius fractures combined with dislocations of the radial heads are rare and easily misdiagnosed.The authors present and discuss a case of proximal radius fractures associated with radial head dislocations.A 36 years old male was admitted to the hospital due to pain and activity limitation in his left elbow for 7 hours due to a car accident.An X-ray of the left elbow joint revealed a“left radius fracture with surrounding soft tissue edema”.During the procedure,the radial head was found to be dislocated forward.A 3.0 mm anchor was used to fix the annular ligament.Radius fractures combined dislocations of the radial heads are rare and may be missing the diagnosis.Before undergoing surgery,the possibility of elbow dislocation should be evaluated.Wire anchors can provide reliable fixation.
文摘AIM To compare the outcomes of displaced distal radius fractures treated with volar locking plates and with immediate postoperative mobilisation with the outcomes of these fractures treated with modalities that necessitate 6 wk wrist immobilisation.METHODS A prospective, randomised controlled single-centre trial was conducted with 56 patients who had a displaced radius fracture were randomised to treatment either with a volar locking plate(n = 29), or another treatment modality(n = 27; cast immobilisation with or without wires or external fixator). Outcomes were measured at 12 wk. Functional outcome scores measured were the Patient-Rated Wrist Evaluation(PRWE) Score; Disabilities of the Arm, Shoulder and Hand and activities of daily living(ADLs). Clinical outcomes were wrist range of motion and grip strength. Radiographic parameters were volar inclination and ulnar variance.RESULTS Patients in the volar locking plate group had significantly better PRWE scores, ADL scores, grip strength and range of extension at three months compared with the control group. All radiological parameters were significantly better in the volar locking plate group at 3 mo. CONCLUSION The present study suggests that volar locking plates produced significantly better functional and clinical outcomes at 3 mo compared with other treatment modalities. Anatomical reduction was significantly more likely to be preserved in the plating group. Level of evidence: Ⅱ.
文摘AIM To determine technical considerations and radiographic outcomes of the Synthes volar rim distal radius plate to treat complex intra-articular fractures. METHODS This review highlights technical considerations learnt using this implant since it was introduced in a major trauma unit in November 2011, including anatomical reduction and whether this was maintained radiographically. RESULTS Twenty-six of the 382 internally fixed distal radial fractures at our unit(6.8%) were deemed to require this plate in order to achieve optimal fracture fixation between November 2011 and May 2014. A further dorsal and/or radial plate was necessary in 35% and variable angle screws were used in 54% of cases. Postoperatively, mean radial height, inclination, volar tilt and ulnar variance restored were 11.7 mm, 21o, 4.3o and-1.2 mm respectively. There were no cases of non-union or flexor/extensor tendon rupture; one case of loss of fracture reduction. Overall incidence of plate removal was 15% with one plate removed for flexor and one for extensor tendon irritation CONCLUSION The use of a rim plate enables control of challenging fardistal fracture patterns. However, additional plates were required to improve and maintain reduction. Variable angle screws were necessary in half the cases to avoid intra-articular screw penetration. If used judiciously, this implant can achieve stable fixation despite the complexity of the fracture pattern.
文摘Objective: To investigate the application of artificial tiger bone powder on fracture healing time, wrist functional recovery and quality of life (QOL) in elderly patients with distal radius fracture. Methods: The study was a randomised controlled trials performed from January 2015 to December 2016 in a hospital. Elderly patients with distal radius fracture were divided into the treatment and the control groups by the random sealed envelope method. All patients were given splint or plaster fixation after manipulative reduction, and functional exercise, the treatment group was also given artificial tiger bone powder orally (trade name: Jintiange capsule), the control group was given an oral placebo in their appearance and usage identical with the treatment group. Prior to treatment and 6, 12 months after treatment, the wrist function was assessed by range of motion, including flexion-extension, radial-ulnar and pronation-supination, and the QOL was assessed by the Mos 36-item Short Form Health Survey. Each patient's fracture healing time was recorded. Results: Before treatment, there were no significant differences in wrist function and QOL between the two groups. At 6 and 12 months after treatment, the wrist function and QOL in the treatment group were better than those in the control group, the differences were statistically significant (P < 0.05). The fracture healing time in the treatment group was shorter than that of the control group, and the difference was statistically significant (P < 0.05). Conclusion: The early usage of artificial tiger bone powder for elderly patients with distal radius fracture can promote the healing of fracture, recovery of wrist joint function, and ultimately improve the QOL for elderly patients.