To obtain the fracture parameters of concrete, fracture tests were conducted with three-point bending beam method aiming at 30 concrete beams with different sizes and different intensity. The concrete specimen with pr...To obtain the fracture parameters of concrete, fracture tests were conducted with three-point bending beam method aiming at 30 concrete beams with different sizes and different intensity. The concrete specimen with prefabricated crack to determine the fracture parameters of concrete were conducted and the fracture performance of the specimen was analyzed. The test results show that, initial fracture toughness is unrelated to the size of specimens; while unstable fracture toughness is related to the size of specimens. As for specimens of bastard size, when concrete intensity is relatively low, unstable fracture toughness increases along with the increase of intensity; when concrete intensity is relatively high, unstable fracture toughness will decrease; when concrete intensity increases continuously, unstable fracture toughness will further increase somewhat. As for specimens of standard size, unstable fracture toughness will increase along with the increase of intensity. Aiming at concrete beam specimens, we conducted two-dimensional non-linear finite element analysis, obtained the stress intensity factor, and carried out contrastive analysis with the experimental results.展开更多
The fatigue performance and fracture mechanism of laser welded twinning induced plasticity(TWIP)steel joint were investigated experimentally based on the evolution of microstructure and micromechanical properties.Th...The fatigue performance and fracture mechanism of laser welded twinning induced plasticity(TWIP)steel joint were investigated experimentally based on the evolution of microstructure and micromechanical properties.The optical microscopy was used to analyze the evolution of microstructure.The variation of composition and phase structure of fusion zone were detected by energy dispersive X-ray and X-ray diffraction spectrometers.The micromechanical behaviors of the various zones were characterized using nanoindentation.The static tensile test and high cycle fatigue test were performed to evaluate the mechanical properties of welded joint and base metal.The microstructures,tensile properties and fatigue strength of base metal as well as welded metal were analyzed.The fatigue fracture surfaces of base metal and welded joint were observed by means of scanning electron microscopy,in order to identify fatigue crack initiation sites and propagation mechanisms.Moreover,the fatigue fracture characteristics and mechanisms for the laser welded TWIP steel joints were analyzed.展开更多
基金Funded by the National Natural Science Foundation of China(No.51279111)The Non-profit Industry Financial Program by the Ministry of Water Resources in2012(No.201201038)
文摘To obtain the fracture parameters of concrete, fracture tests were conducted with three-point bending beam method aiming at 30 concrete beams with different sizes and different intensity. The concrete specimen with prefabricated crack to determine the fracture parameters of concrete were conducted and the fracture performance of the specimen was analyzed. The test results show that, initial fracture toughness is unrelated to the size of specimens; while unstable fracture toughness is related to the size of specimens. As for specimens of bastard size, when concrete intensity is relatively low, unstable fracture toughness increases along with the increase of intensity; when concrete intensity is relatively high, unstable fracture toughness will decrease; when concrete intensity increases continuously, unstable fracture toughness will further increase somewhat. As for specimens of standard size, unstable fracture toughness will increase along with the increase of intensity. Aiming at concrete beam specimens, we conducted two-dimensional non-linear finite element analysis, obtained the stress intensity factor, and carried out contrastive analysis with the experimental results.
基金Item Sponsored by National Natural Science Foundation of China(51374151,21201129)Science and Technology Major Project of Shanxi Province of China(20111101053)Natural Science Foundation of Shanxi Province of China(2011011020-2)
文摘The fatigue performance and fracture mechanism of laser welded twinning induced plasticity(TWIP)steel joint were investigated experimentally based on the evolution of microstructure and micromechanical properties.The optical microscopy was used to analyze the evolution of microstructure.The variation of composition and phase structure of fusion zone were detected by energy dispersive X-ray and X-ray diffraction spectrometers.The micromechanical behaviors of the various zones were characterized using nanoindentation.The static tensile test and high cycle fatigue test were performed to evaluate the mechanical properties of welded joint and base metal.The microstructures,tensile properties and fatigue strength of base metal as well as welded metal were analyzed.The fatigue fracture surfaces of base metal and welded joint were observed by means of scanning electron microscopy,in order to identify fatigue crack initiation sites and propagation mechanisms.Moreover,the fatigue fracture characteristics and mechanisms for the laser welded TWIP steel joints were analyzed.