Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous ...Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience.展开更多
The local design and construction practices in the United Arab Emirates (UAE), together with Dubai's unique rate of development, warrant special attention to the selection of Lateral Force-Resisting Systems (LFRS...The local design and construction practices in the United Arab Emirates (UAE), together with Dubai's unique rate of development, warrant special attention to the selection of Lateral Force-Resisting Systems (LFRS). This research proposes four different feasible solutions for the selection of the LFRS for tall buildings and quantifies the impact of these selections on seismic performance and cost. The systems considered are: Steel Special Moment-Resisting Frame (SMRF), Concrete SMRF, Steel Dual System (SMRF with Special Steel Plates Shear Wall, SPSW), and Concrete Dual System (SMRF with Special Concrete Shear Wall, SCSW). The LFRS selection is driven by seismic setup as well as the adopted design and construction practices in Dubai. It is found that the concrete design alternatives are consistently less expensive than their steel counterparts. The steel dual system is expected to have the least damage based on its relatively lesser interstory drifts. However, this preferred performance comes at a higher initial construction cost. Conversely, the steel SMRF system is expected to have the most damage and associated repair cost due to its excessive flexibility. The two concrete alternatives are expected to have relatively moderate damage and repair costs in addition to their lesser initial construction cost.展开更多
The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthqu...The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthquake, resulting in too high repair costs or having to dismantle and rebuild. In order to improve and enhance the anti-seismic performance of the RC framework structure, energy consumption devices are added between the frame columns to achieve the effect of reducing the RC frame structure damage and improving the seismic performance of the RC frame structure. In this article, high-performance fiber-enhanced cement base composite materials fabricated energy consumption walls are prepared in the RC frame structure to form a new type of seismic structure system of RC frame-prefabricated HPFRCC energy consumption wall. This article uses the power timing analysis of the ABAQUS finite element software to study the anti-seismic performance, influencing factors and energy consumption distribution of the RC frame-prefabricated HPFRCC energy wall structural system.展开更多
基金Natural Science Foundation of China under Grant Nos.51178342 and 51578314
文摘Earthquake investigations have illustrated that even code-compliant reinforced concrete frames may suffer from soft-story mechanism.This damage mode results in poor ductility and limited energy dissipation.Continuous components offer alternatives that may avoid such failures.A novel infilled rocking wall frame system is proposed that takes advantage of continuous component and rocking characteristics.Previous studies have investigated similar systems that combine a reinforced concrete frame and a wall with rocking behavior used.However,a large-scale experimental study of a reinforced concrete frame combined with a rocking wall has not been reported.In this study,a seismic performance evaluation of the newly proposed infilled rocking wall frame structure was conducted through quasi-static cyclic testing.Critical joints were designed and verified.Numerical models were established and calibrated to estimate frame shear forces.The results evaluation demonstrate that an infilled rocking wall frame can effectively avoid soft-story mechanisms.Capacity and initial stiffness are greatly improved and self-centering behavior is achieved with the help of the infilled rocking wall.Drift distribution becomes more uniform with height.Concrete cracks and damage occurs in desired areas.The infilled rocking wall frame offers a promising approach to achieving seismic resilience.
文摘The local design and construction practices in the United Arab Emirates (UAE), together with Dubai's unique rate of development, warrant special attention to the selection of Lateral Force-Resisting Systems (LFRS). This research proposes four different feasible solutions for the selection of the LFRS for tall buildings and quantifies the impact of these selections on seismic performance and cost. The systems considered are: Steel Special Moment-Resisting Frame (SMRF), Concrete SMRF, Steel Dual System (SMRF with Special Steel Plates Shear Wall, SPSW), and Concrete Dual System (SMRF with Special Concrete Shear Wall, SCSW). The LFRS selection is driven by seismic setup as well as the adopted design and construction practices in Dubai. It is found that the concrete design alternatives are consistently less expensive than their steel counterparts. The steel dual system is expected to have the least damage based on its relatively lesser interstory drifts. However, this preferred performance comes at a higher initial construction cost. Conversely, the steel SMRF system is expected to have the most damage and associated repair cost due to its excessive flexibility. The two concrete alternatives are expected to have relatively moderate damage and repair costs in addition to their lesser initial construction cost.
文摘The weak layer of steel concrete (RC) frame structure is easy to destroy under the action of the earthquake, the damage mechanism is more difficult to control. Severe damage to the building structure after the earthquake, resulting in too high repair costs or having to dismantle and rebuild. In order to improve and enhance the anti-seismic performance of the RC framework structure, energy consumption devices are added between the frame columns to achieve the effect of reducing the RC frame structure damage and improving the seismic performance of the RC frame structure. In this article, high-performance fiber-enhanced cement base composite materials fabricated energy consumption walls are prepared in the RC frame structure to form a new type of seismic structure system of RC frame-prefabricated HPFRCC energy consumption wall. This article uses the power timing analysis of the ABAQUS finite element software to study the anti-seismic performance, influencing factors and energy consumption distribution of the RC frame-prefabricated HPFRCC energy wall structural system.