This paper presents the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions betwe...This paper presents the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions between outriggers and core wall as well as the finite rigidities of outriggers are also considered. One case study was carried out to analyze the horizontal top deflection and the mutation of the restraining moments caused by the variation of outrigger location. The results showed that the method adopted in the paper is simple and reasonable. Some conclusions are valuable to the safety design of high-rise building structures.展开更多
Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between ...Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between stiffness characteristic parameters of frame and outriggers and the top drift of structures under different loads is analyzed. It is indicated that when stiffness characteristic parameter of frame is large, outrigger efficiency for top drift reduction is low, and the mutation of internal forces occurs; when the stiffness characteristic parameter of frame is less than 3, installing the strengthened story is advantageous to frame-core structures.展开更多
基金Project supported by the National Natural Science Foundation of China (No. 50378041) and the Specialized Research Fund for theDoctoral Program of Higher Education (No. 20030487016), China
文摘This paper presents the restraining moments of outriggers acting on the core wall and the equation of the horizontal top deflection based on a simplified outrigger model. The deformation compatibility conditions between outriggers and core wall as well as the finite rigidities of outriggers are also considered. One case study was carried out to analyze the horizontal top deflection and the mutation of the restraining moments caused by the variation of outrigger location. The results showed that the method adopted in the paper is simple and reasonable. Some conclusions are valuable to the safety design of high-rise building structures.
基金The Natural Science Foundation of China(No.50708041)
文摘Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between stiffness characteristic parameters of frame and outriggers and the top drift of structures under different loads is analyzed. It is indicated that when stiffness characteristic parameter of frame is large, outrigger efficiency for top drift reduction is low, and the mutation of internal forces occurs; when the stiffness characteristic parameter of frame is less than 3, installing the strengthened story is advantageous to frame-core structures.