We demonstrated a continuous wave(cw) single-frequency intracavity frequency-doubled Nd:YVO_4/LBO laser with 532 nm output of 7.5 W and 1.06 μm output of 3.1 W, and low intensity noise in audio frequency region.To su...We demonstrated a continuous wave(cw) single-frequency intracavity frequency-doubled Nd:YVO_4/LBO laser with 532 nm output of 7.5 W and 1.06 μm output of 3.1 W, and low intensity noise in audio frequency region.To suppress the intensity noise of the high power 532 nm laser, a laser frequency locking system and a feedback loop based on a Mach-Zehnder interferometer were designed and used.The influences of the frequency stabilization and the crucial parameters of the MZI, such as the power splitting ratio of the beam splitters and the locking state of the MZI, on the intensity noise of the 532 nm laser were investigated in detail.After the experimental optimizations, the laser intensity noise in the frequency region from 0.4 kHz to 10 kHz was significantly suppressed.展开更多
为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局...为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。展开更多
For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PS...For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PSS). This paper introduces the principles and methods of parameter selection for PSS, in addition to field test. The test results show that the PSS installed can significantly improve the system damping.展开更多
System frequency must be kept very close to its nominal range to ensure the stability of an electric power grid.Excessive system frequency variations are able to result in load shedding,frequency instability,and even ...System frequency must be kept very close to its nominal range to ensure the stability of an electric power grid.Excessive system frequency variations are able to result in load shedding,frequency instability,and even generator damage.With increasing wind power penetration,there is rising concern about the reduction in inertia response and primary frequency control in the electric power grid.Converter-based wind generation is capable of providing inertia response and primary frequency response;nevertheless,the primary frequency and inertia responses of wind generation are different from those of conventional synchronous fleets;it is not completely understood how the primary frequency and inertia responses affect the given system under various disturbances and available kinetic energy levels.Simulations are used to investigate the influences of inertia and droop control strategies on the dynamic frequency responses,particularly the index of the second frequency drop under various disturbance and wind conditions.A quantitative analysis provides insight into setting of inertia and droop control coefficients for various wind and disturbance conditions to facilitate adequate dynamic frequency responses during frequency events.展开更多
In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power s...In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.展开更多
The 10-GW-class Jiuquan Wind Power Base in Gansu Province is to get its Phase I Project completed soon, and will further expand and become the world largest wind power base in the future. Whether electricity from the ...The 10-GW-class Jiuquan Wind Power Base in Gansu Province is to get its Phase I Project completed soon, and will further expand and become the world largest wind power base in the future. Whether electricity from the wind power base can be delivered on such a large scale becomes the focus of attention of the world. This paper analyzes four challenges facing the wind power base, including transmission capability, peak regulation and frequency modulation, capacity balance and generation accommodation, as well as system stability.展开更多
基金Project supported by the National Key R&D Program of China(Grant No.2016YFA0301401)
文摘We demonstrated a continuous wave(cw) single-frequency intracavity frequency-doubled Nd:YVO_4/LBO laser with 532 nm output of 7.5 W and 1.06 μm output of 3.1 W, and low intensity noise in audio frequency region.To suppress the intensity noise of the high power 532 nm laser, a laser frequency locking system and a feedback loop based on a Mach-Zehnder interferometer were designed and used.The influences of the frequency stabilization and the crucial parameters of the MZI, such as the power splitting ratio of the beam splitters and the locking state of the MZI, on the intensity noise of the 532 nm laser were investigated in detail.After the experimental optimizations, the laser intensity noise in the frequency region from 0.4 kHz to 10 kHz was significantly suppressed.
文摘为了演示和验证稳定器设计的就地相位补偿法在多机电力系统中的应用,介绍在多机电力系统中,就地补偿设计稳定器的2个应用实例。第1个实例是在多机电力系统中就地补偿设计电力系统稳定器(power system stabilizer,PSS),阻尼电力系统局部模振荡。第2个实例是就地补偿设计附加在静态同步补偿器(static synchronous compensator,STATCOM)上的稳定器,抑制多机电力系统中的区域模振荡,并给出在一个16机电力系统中的应用计算和仿真结果。
文摘For solving the dynamic instability problem of Yunnan Provincial Power System (YNPS) and the South China Interconnected Power System (SCIPS), Lubuge Hydropower Station was chosen to install Power System Stabilizer (PSS). This paper introduces the principles and methods of parameter selection for PSS, in addition to field test. The test results show that the PSS installed can significantly improve the system damping.
基金This work was supported by the Natural Science Foundation of the Jiangsu Higher Education Institutions of China(20KJB470026)Key Project of Smart Grid Technology and Equipment of National Key Research and Development Plan of China(2016YFB0900601).
文摘System frequency must be kept very close to its nominal range to ensure the stability of an electric power grid.Excessive system frequency variations are able to result in load shedding,frequency instability,and even generator damage.With increasing wind power penetration,there is rising concern about the reduction in inertia response and primary frequency control in the electric power grid.Converter-based wind generation is capable of providing inertia response and primary frequency response;nevertheless,the primary frequency and inertia responses of wind generation are different from those of conventional synchronous fleets;it is not completely understood how the primary frequency and inertia responses affect the given system under various disturbances and available kinetic energy levels.Simulations are used to investigate the influences of inertia and droop control strategies on the dynamic frequency responses,particularly the index of the second frequency drop under various disturbance and wind conditions.A quantitative analysis provides insight into setting of inertia and droop control coefficients for various wind and disturbance conditions to facilitate adequate dynamic frequency responses during frequency events.
基金This work is supported by Shanghai Science and Technology Planning Project(Project No.20040501200).
文摘In themarine electric power system,the marine generators will be disturbed by the large change of loads or the fault of the power system.The marine generators usually installed power system stabilizers to damp power system oscillations through the excitation control.This paper proposes a novel method to obtain optimal parameter values for Power System Stabilizer(PSS)to suppress low-frequency oscillations in the marine electric power system.In this paper,a newly developed immune clone selection algorithm was improved from the three aspects of the adaptive incentive degree,vaccination,and adaptive mutation strategies.Firstly,the typical PSS implementation type of leader-lag structure was adopted and the objective function was set in the optimization process.The performance of PSS tuned by improved immune clone selection algorithm was compared with PSS tuned by basic immune clone selection algorithm(ICSA)under various operating conditions and disturbances.Then,an improved immune clone selection algorithm(IICSA)optimization technique was implemented on two test systems for test purposes.Based on the simulations,it is found that an improved immune clone selection algorithm demonstrates superiority over the basic immune clone selection algorithm in getting a smaller number of iterations and fast convergence rates to achieve the optimal parameters of the power system stabilizers.Moreover,the proposed approach improves the stability and dynamic performance under various loads conditions and disturbances of the marine electric power system.
文摘The 10-GW-class Jiuquan Wind Power Base in Gansu Province is to get its Phase I Project completed soon, and will further expand and become the world largest wind power base in the future. Whether electricity from the wind power base can be delivered on such a large scale becomes the focus of attention of the world. This paper analyzes four challenges facing the wind power base, including transmission capability, peak regulation and frequency modulation, capacity balance and generation accommodation, as well as system stability.