Wider frequency domain for negative refraction index in a quantized composite right–left handed transmission line
1
作者 吴奇宣 赵顺才 《Chinese Physics B》 SCIE EI CAS CSCD 2018年第6期468-472,共5页
The refraction index of the quantized lossy composite right-left handed transmission line(CRLH-TL) is deduced in the thermal coherence state. The results show that the negative refraction index(herein the left-hand... The refraction index of the quantized lossy composite right-left handed transmission line(CRLH-TL) is deduced in the thermal coherence state. The results show that the negative refraction index(herein the left-handedness) can be implemented by the electric circuit dissipative factors(i.e., the resistances R and conductances G) in a higher frequency band(1.446 GHz≤ ω ≤ 15 GHz), and flexibly adjusted by the left-handed circuit components(Cl, Ll) and the right-handed circuit components(Cr, Lr) at a lower frequency(ω = 0.995 GHz). The flexible adjustment for left-handedness in a wider bandwidth will be significant for the microscale circuit design of the CRLH-TL and may make the theoretical preparation for its compact applications. 展开更多
关键词 quantized composite right-left handed transmission line negative refraction index frequency do- main
下载PDF
Small-current grounding fault location method based on transient main resonance frequency analysis 被引量:2
2
作者 Yongjie Zhang Xiaojun Wang +2 位作者 Junjuan Li Yin Xu Guohong Wu 《Global Energy Interconnection》 2020年第4期324-334,共11页
The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we t... The small-current grounding fault in distribution network is hard to be located because of its weak fault features.To accurately locate the faults,the transient process is analyzed in this paper.Through the study we take that the main resonant frequency and its corresponding component is related to the fault distance.Based on this,a fault location method based on double-end wavelet energy ratio at the scale corresponding to the main resonant frequency is proposed.And back propagation neural network(BPNN)is selected to fit the non-linear relationship between the wavelet energy ratio and fault distance.The performance of this proposed method has been verified in different scenarios of a simulation model in PSCAD/EMTDC. 展开更多
关键词 Small-current grounding fault location main resonant frequency Double-end wavelet energy ratio Backpropagation neural network(BPNN)
下载PDF
The Applications of High-voltage variable frequency speed regulation System in Main Exhauster of Sintering
3
作者 Li Jingwei 《International English Education Research》 2015年第9期8-10,共3页
关键词 高压变频调速系统 主抽风机 烧结生产 应用 钢铁企业 生产用电 节能改造 同步电机
下载PDF
大型风电腰荷接入的主网安全调度方法
4
作者 竺炜 杨子琦 +2 位作者 祁俊辉 肖魏 唐颖杰 《电力科学与技术学报》 CAS CSCD 北大核心 2024年第2期1-8,共8页
风功率波动性大,日前预测准确性较差,导致大型风电消纳与电网安全鲁棒性的矛盾。提出一种风电“腰荷”出力接入的自动调频调度方法,以减少弃风量且提高风电功率大幅波动下的主网在线安全性。首先,为提高日前风功率神经网络预测的收敛性... 风功率波动性大,日前预测准确性较差,导致大型风电消纳与电网安全鲁棒性的矛盾。提出一种风电“腰荷”出力接入的自动调频调度方法,以减少弃风量且提高风电功率大幅波动下的主网在线安全性。首先,为提高日前风功率神经网络预测的收敛性,提出时序矩阵奇异值分解的多样本数据预处理方法;其次,为得到与日前风功率预测相关的腰荷出力计划曲线,采用多项式回归拟合及基准功率偏差,得到相关性较大的光滑曲线;然后,为减小在线风功率骤减导致的频率偏差,设定调频机组自动调频的“启动”曲线族;最后,为保持自动调频后主网有功潮流分布合理并提高功角安全性,采用等效功角最小的优化模型,得到各调频机组出力增量的最优分配方案。算例验证该调度方法的可行性,对减少大型风电的弃风并提高电网安全运行水平具有理论和实际意义。 展开更多
关键词 大型风电 腰荷出力接入 自动调频 优化调度 主网功角安全性
下载PDF
基于小波变换算法的普朗铜矿爆破振动信号能量分布研究
5
作者 刘明武 黄永辉 +4 位作者 李争荣 贾皓琦 甘等俊 李洪超 张智宇 《中国矿业》 北大核心 2024年第3期226-234,共9页
小波变换算法能够对爆破振动信号的频率、能量分布特征进行研究,按照不同的主振频带对爆破振动信号进行分解及重构,已被广泛应用于爆破振动稳定性分析以及矿山安全生产管理。针对在矿山复杂条件下爆破振动信号易受干扰等问题,以普朗铜... 小波变换算法能够对爆破振动信号的频率、能量分布特征进行研究,按照不同的主振频带对爆破振动信号进行分解及重构,已被广泛应用于爆破振动稳定性分析以及矿山安全生产管理。针对在矿山复杂条件下爆破振动信号易受干扰等问题,以普朗铜矿南部拉底爆破振动数据为研究对象,采用小波变换算法分析振动信号0~125 Hz各个频率段能量分布情况,通过HHT算法、STFT算法分别对爆区近区、爆区远区开展能量分布及其衰减规律的研究。研究结果表明:在0~125 Hz频率段范围内,爆区近区和爆区远区能量衰减速度和分布不同,爆区近区能量主振频率分布在15.62~<31.20 Hz频率段,爆区远区能量主振频率分布在46.87~<93.75 Hz频率段。在15.62~<31.20 Hz频率段,爆区近区比爆区远区能量占比平均多出14.1%;在46.87~<93.75 Hz频率段,爆区远区比爆区近区能量占比平均多出18.65%。基于本次爆破施工所监测到的普朗铜矿南部巷道区域爆破振动数据得出,在0~125 Hz频率段范围内,爆区近区能量衰减速度较快且能量分布不集中,爆区远区能量衰减速度较为缓慢且能量分布密集;爆破振动能量随着传播距离增加,能量虽有所衰减,但能量分布更为集中。分析结果表明,小波变换算法可以真实反映振动信号的能量分布情况,为研究爆破振动效应下的井下构筑物的结构安全提供有效的分析手段。 展开更多
关键词 小波变换 爆破振动 能量分布 HHT算法 STFT算法 主振频率
下载PDF
TDI发动机润滑油挤压高频噪声影响因素试验研究
6
作者 刘亚奇 吴恢栋 +2 位作者 赵国超 曹永伟 马瑞瑄 《车用发动机》 北大核心 2024年第3期46-49,共4页
针对涡轮增压柴油机的运行特点,在半消声试验室进行了发动机加速工况主轴承处润滑油挤压高频噪声的影响因素测试。研究过程基于发动机主轴承座振动测试和曲轴运动轨迹测试,重点分析了润滑系统特征和主轴承结构特征以及曲轴轴承支撑方式... 针对涡轮增压柴油机的运行特点,在半消声试验室进行了发动机加速工况主轴承处润滑油挤压高频噪声的影响因素测试。研究过程基于发动机主轴承座振动测试和曲轴运动轨迹测试,重点分析了润滑系统特征和主轴承结构特征以及曲轴轴承支撑方式对高频挤压噪声的影响。结果表明:润滑油黏度、润滑油含气量、主轴承间隙、主轴颈形状和轴承支撑方式等均对主轴承座异常振动产生影响;当轴承载荷小,轴心偏心距较大,曲轴自转方向与公转方向相反时,主轴承润滑油压力升高,润滑油内的气泡被挤压产生高频的气泡破裂噪声,并伴随主轴承座异常振动;当曲轴运转稳定且轴心轨迹平顺时,主轴承座异常振动对应转速升高,高频噪声不易识别。 展开更多
关键词 柴油机 主轴承座 振动 高频噪声 轴心轨迹
下载PDF
基于小波包理论研究地下断层对爆破振动传播的影响
7
作者 贾皓琦 黄永辉 张智宇 《有色金属(矿山部分)》 2024年第2期35-44,共10页
为了研究云南某金属地下矿山断层对爆破振动波传播的影响,选用含有断层区域3736北部中段区域、无断层区域3736南部中段区域布置测点。以云南某金属地下矿山真实采集爆破振动数据为研究对象,基于小波包变换、HHT算法、STFT算法开展爆破... 为了研究云南某金属地下矿山断层对爆破振动波传播的影响,选用含有断层区域3736北部中段区域、无断层区域3736南部中段区域布置测点。以云南某金属地下矿山真实采集爆破振动数据为研究对象,基于小波包变换、HHT算法、STFT算法开展爆破振动波衰减规律的研究。结果表明:云南某地下金属矿山振动波经过断层前瞬时能量幅值达到10×10^(-4)dB,经过断层后瞬时能量幅值达到1.5×10^(-4)dB,瞬时能量幅值衰减85%;断层在一定程度上会扰乱振动波能量分布情况,延缓振动能量迅速上升;振动波经过断层后低频能量衰减60%,高频能量衰减71%,总体能量功率衰减77%,无断层区域高频能量衰减18%,低频能量衰减17%,总体能量功率衰减15%;爆破振动波经过断层后,过滤大量高频能量,能量总体分布呈现向低频域方向发展的趋势。 展开更多
关键词 爆破振动 地下断层 振动主频 小波包变换
下载PDF
On electro-acoustic characteristics of a marine broadband sparker for seismic exploration
8
作者 Jing LI Kai LIU +3 位作者 Liancheng ZHANG Chenguang LIU Yanliang PEI Baohua LIU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2024年第3期760-771,共12页
The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic explora... The construction of major marine infrastructure projects and the exploration and development of deep-sea mineral resources require fine imaging of seabed strata and structures.The highresolution marine seismic exploration based on a high broadband sparker source is an important approach to reveal seabed stratum and reservoir structure,and identify geohazard.To optimize the performance of sparker seismic source,we investigated the electro-acoustic characteristics of spark discharge under conditions of different charging voltages and electrode numbers.Results show that the sound source level increased with the increase of the charging voltage,whereas the main frequency decreased when the charging voltage increases.In addition,it was found that the charging capacitance had more obvious influence on the main frequency than the sound source level did.Although the load energy decreased with increasing electrode number,the sound source level still increased but the main frequency decreased.Meanwhile,the primary to bubble(P/B)ratio increased with the increase of the electrode number.To gain a deeper insight into the electro-acoustic characteristics,we investigate the relationship between sound source level and power peak,from which a good correlation was observed.A more practical statistical analysis on the rise rate of current was processed,and a perfect logarithmic function was derived.Furthermore,we found that the main frequency was most possibly subjected to the electrical energy,especially the charging energy per electrode.The results indicate that the charging energy per electrode less than 10 J could increase the main frequency to above 300 Hz.At last,the main frequency could be reduced to 20 Hz when the charging energy of a single-electrode discharge was enhanced to over 4 kJ.This study shall be helpful in developing a sparker seismic source and improving the performance for marine engineering exploration and geohazard assessment. 展开更多
关键词 high-resolution marine seismic exploration sparker seismic source sound source level main frequency electro-acoustic characteristics
下载PDF
速度160 km/h列车通过隧道时侧向气动力变化特征
9
作者 贲晓东 房明 +3 位作者 徐成州 岳文志 申少杰 毕海权 《城市轨道交通研究》 北大核心 2024年第5期149-153,共5页
[目的]我国某动车组以160 km/h的速度在明线运行时列车平稳性良好,但通过单线隧道时尾车出现周期性横向晃动的问题,需要对该动车组过隧道时列车气动特性进行深入研究。[方法]采用数值模拟方法,基于RNG k-ε湍流模型和滑移网格技术,建立... [目的]我国某动车组以160 km/h的速度在明线运行时列车平稳性良好,但通过单线隧道时尾车出现周期性横向晃动的问题,需要对该动车组过隧道时列车气动特性进行深入研究。[方法]采用数值模拟方法,基于RNG k-ε湍流模型和滑移网格技术,建立了带有转向架的某动车组的三维可压缩瞬态仿真模型,研究了列车通过隧道时尾车表面压力变化情况;同时,在时域和频域内分析了列车侧向气动力特征的瞬态性质。[结果及结论]由于隧道壁面对空气流动的限制和列车尾绕流的作用,列车通过隧道时车体两侧存在压差并呈现出交替变化的特征,并且尾车侧向力交变特征更明显;列车所受侧向力具有低频周期性交变特点,主频约为2.2 Hz,且在尾车刚进隧道时气动效应最强,侧向力波动幅度最大;列车侧向力变化值可作为车辆横向平稳性分析的边界条件。 展开更多
关键词 动车组 尾车横向晃动 隧道 气动载荷 侧向力主频 尾涡脱落
下载PDF
频控阵对施放随队支援电子干扰的影响研究
10
作者 张晶 王博 《空天预警研究学报》 CSCD 2024年第1期31-37,共7页
针对频控阵(FDA)雷达辐射波束“弯曲”特性对电子支援飞机遂行随队支援电子干扰任务过程产生的影响展开分析.首先,建立FDA雷达结构模型,在此基础上分析FDA雷达测向欺骗性能对敌方干扰机天线测向对准过程的影响,以及FDA雷达对干扰机施放... 针对频控阵(FDA)雷达辐射波束“弯曲”特性对电子支援飞机遂行随队支援电子干扰任务过程产生的影响展开分析.首先,建立FDA雷达结构模型,在此基础上分析FDA雷达测向欺骗性能对敌方干扰机天线测向对准过程的影响,以及FDA雷达对干扰机施放随队支援干扰的抑制效果.分析结果表明,FDA雷达能够使无源测向系统产生测角误差,进而影响干扰发射天线对干扰接收天线的空域覆盖.同时,基于FDA的自适应波束形成器能够有效抑制电子战飞机施放的随队支援干扰,进而实现对突防编队的探测及跟踪. 展开更多
关键词 频控阵 干涉仪 主瓣干扰 随队支援电子干扰 空域覆盖
下载PDF
某核电主泵变频器冷却系统高温异常处置分析 被引量:1
11
作者 史磊 刘竞婷 《机电工程技术》 2024年第1期10-13,共4页
某AP1000核电厂主泵变频器冷却系统出现出口温度异常高的情况,影响了主泵变频器内隔离变压器和功率单元的冷却效果,可能导致变频器故障,进而造成主泵停运和核电机组跳堆风险,对核电机组的安全稳定运行造成严重挑战。通过对变频器冷却系... 某AP1000核电厂主泵变频器冷却系统出现出口温度异常高的情况,影响了主泵变频器内隔离变压器和功率单元的冷却效果,可能导致变频器故障,进而造成主泵停运和核电机组跳堆风险,对核电机组的安全稳定运行造成严重挑战。通过对变频器冷却系统内特有的温度调节阀进行结构和动作原理的分析,同时对比了其他3台主泵变频器的参数变化,准确确定了主泵变频器冷却系统出口温度异常高的原因是温度调节阀故障,并成功处理了该故障。通过总结经验,为后续AP1000核电厂主泵变频器出现类似缺陷时的处理提供了借鉴。 展开更多
关键词 主泵变频器 AP1000 温度 异常处置
下载PDF
主蒸汽压力对汽轮机动态响应的影响研究
12
作者 陈晓峰 朱龙飞 +4 位作者 左川 谢昌亚 仇晓智 赵博冬 郭有福 《节能技术》 CAS 2024年第1期64-67,72,共5页
传统汽轮机模型将锅炉看作一无限大蓄热环节,并未考虑主蒸汽压力的变化,这使得主蒸汽流量仅为阀门开度的函数。然而,实际过程中主蒸汽压力会因锅炉蓄热状态以及汽轮机阀门开度变化会产生波动,并非处于恒定状态。因此若忽略主汽压影响,... 传统汽轮机模型将锅炉看作一无限大蓄热环节,并未考虑主蒸汽压力的变化,这使得主蒸汽流量仅为阀门开度的函数。然而,实际过程中主蒸汽压力会因锅炉蓄热状态以及汽轮机阀门开度变化会产生波动,并非处于恒定状态。因此若忽略主汽压影响,所建模型仿真精度将严重受限,本文在传统汽轮机模型基础上考虑主蒸汽压力变化因素,建立了更为精细的汽轮机模型,并通过仿真研究了主蒸汽压力对汽轮机动态响应的影响。 展开更多
关键词 汽轮机模型 主蒸汽压力 动态响应 调峰调频
下载PDF
主变压器噪声特性分析及复合隔声结构设计
13
作者 王坤 谢连科 +3 位作者 邢拓 巩泉泉 张国英 朱亦丹 《应用声学》 CSCD 北大核心 2024年第2期315-320,共6页
超高压变电站的主变压器的噪声影响已引起广泛关注。以某典型化设计的500kV变电站A的主变压器为例,进行了现场测试,得到其主变压器噪声能量主要集中在中低频范围内,且具备明显的线谱噪声特征。针对该噪声特点,提出了一种内插微穿孔板的... 超高压变电站的主变压器的噪声影响已引起广泛关注。以某典型化设计的500kV变电站A的主变压器为例,进行了现场测试,得到其主变压器噪声能量主要集中在中低频范围内,且具备明显的线谱噪声特征。针对该噪声特点,提出了一种内插微穿孔板的双层带孔板型声学超材料的复合隔声结构。使用传递矩阵理论对该复合结构进行了分析,并在阻抗管中进行了实验验证。实验结果表明:该复合隔声结构具备针对性隔声要求,理论与实验传递损失曲线基本吻合。 展开更多
关键词 主变噪声 低频隔声 带孔板型超材料 微穿孔板
下载PDF
扬程特性关联下矿井主泵排水智能控制方法研究
14
作者 陈刚 《自动化与仪表》 2024年第2期114-118,共5页
矿井下常常存在地下水渗积问题,通过控制主泵出水压力,能够有效地排除积水,保持井下环境相对干燥,增强煤矿地下环境的安全性。但由于矿井下的透水后压力负荷通常是不确定的,单纯以压力为传感信号的主泵排水控制的稳定性会受到较大影响,... 矿井下常常存在地下水渗积问题,通过控制主泵出水压力,能够有效地排除积水,保持井下环境相对干燥,增强煤矿地下环境的安全性。但由于矿井下的透水后压力负荷通常是不确定的,单纯以压力为传感信号的主泵排水控制的稳定性会受到较大影响,当前排水多以人工观测为主,排水控制智能化实现难度较大。提出一种扬程特性关联下矿井主泵排水智能控制方法。分析矿井下大功率变频式主泵的扬程特性(H-Q),获取变频式主泵排水压力和扬程特性(H-Q)之间的关系。利用这一关系作为传感信号,采用解耦补偿器和神经网络,利用神经网络在线调整比例、积分和微分(proportional integral derivative,PID)控制参数,组建大功率变频式主泵出水压力智能控制器,实现泵出水压力智能控制。通过实验分析证明,研究方法应用后在22 s左右矿井主泵达到最佳状态,过程中产生的相对误差均在0.5%以下。在多次迭代控制下,所提方法的控制延误始终低于0.1 ms。 展开更多
关键词 矿井环境 大功率 变频式主泵 扬程特性 出水压力 智能控制
下载PDF
煤矿主扇通风机变频控制系统的研究
15
作者 李义 《江西煤炭科技》 2024年第2期173-175,179,共4页
以FBCDZNo24/2×200对旋式轴流式通风机为研究对象,基于变频技术设计了设备的变频控制系统。该系统以S7-300系列PLC控制器为核心,变频器选用型号为SJ700-3150HFE2,配合使用风机在线调节,可达到节能降耗之目的。通过15个月时间地应... 以FBCDZNo24/2×200对旋式轴流式通风机为研究对象,基于变频技术设计了设备的变频控制系统。该系统以S7-300系列PLC控制器为核心,变频器选用型号为SJ700-3150HFE2,配合使用风机在线调节,可达到节能降耗之目的。通过15个月时间地应用实践,设备故障率降低10%,能耗降低15%。 展开更多
关键词 主扇通风机 变频技术 控制系统 PLC控制器
下载PDF
高压变频节能改造技术在煤矿主通风机中的应用
16
作者 位晓林 《中国高新科技》 2024年第1期70-72,共3页
主通风机是煤矿的主要设备之一,部分煤矿在开采后期主通风机的运行功率远超出煤矿正常生产所需运行功率,能量损耗较为严重。基于此,文章针对煤矿主通风机高压变频节能改造需求,提出了煤矿主通风机高压变频节能改造方案。经实践分析,煤... 主通风机是煤矿的主要设备之一,部分煤矿在开采后期主通风机的运行功率远超出煤矿正常生产所需运行功率,能量损耗较为严重。基于此,文章针对煤矿主通风机高压变频节能改造需求,提出了煤矿主通风机高压变频节能改造方案。经实践分析,煤矿主通风机高压变频节能改造效果较好,实现了提质增效的目的。 展开更多
关键词 高压变频 节能技术 主通风机
下载PDF
综合物探方法在城市道路典型障碍物定位研究中的应用
17
作者 杨超 《物探化探计算技术》 CAS 2024年第2期215-223,共9页
在城市主干道路改扩建工程中,为准确测定地下原水箱涵及其附属隐伏护管桥的空间位置,保障高架桥梁桩基的准确设计及顺利施工,采用高密度电法、地震面波法、探地雷达法、GEM-2多频电磁法等几种常用工程物探方法,旨在对比方法有效性,总结... 在城市主干道路改扩建工程中,为准确测定地下原水箱涵及其附属隐伏护管桥的空间位置,保障高架桥梁桩基的准确设计及顺利施工,采用高密度电法、地震面波法、探地雷达法、GEM-2多频电磁法等几种常用工程物探方法,旨在对比方法有效性,总结技术要点,为城市道路典型障碍物定位研究积累技术资料及工程经验。地下原水箱涵道及其附属隐伏护管桥为钢筋混凝土,具有特殊的工程结构,与地层具有明显的物性差异,这里利用GEM-2多频电磁法清晰地准确地探测到了护管桥的平面边界,高密度电法、地震面波法较为有效地圈定了护管桥及原水箱涵的空间位置,探地雷达法清晰地探测到了护管桥区域,并且精细地刻画了原水箱涵及护管桥的空间关系,这些成果为类似城市道路工程问题的地球物理勘察提供了实践依据及解决方案。 展开更多
关键词 城市主干道路 护管桥 原水箱涵 多频电磁法 高密度电法 地震面波 探地雷达
下载PDF
10kV高压防爆变频器在煤矿主运皮带机的应用
18
作者 任其广 高栋 +1 位作者 郭延双 张元吉 《变频器世界》 2024年第5期85-88,共4页
本文介绍了新风光10kV高压防爆变频器在贵州省大方县营兴煤矿主运皮带机中的应用情况,对应用案例进行了介绍。结果表明,采用单元级联主回路拓扑结构的防爆变电变频器装置,它相比传统井下变频器具有低频力矩大、输入输出谐波含量低、操... 本文介绍了新风光10kV高压防爆变频器在贵州省大方县营兴煤矿主运皮带机中的应用情况,对应用案例进行了介绍。结果表明,采用单元级联主回路拓扑结构的防爆变电变频器装置,它相比传统井下变频器具有低频力矩大、输入输出谐波含量低、操作供电方便、长距离供电、主从机功率平衡等优点,在煤矿皮带机输送系统上采用防爆变电变频器具有较高的经济效益和社会效益。 展开更多
关键词 高压防爆变频器 主运皮带机 长距离供电 谐波 功率平衡
下载PDF
基于熄弧后主谐振频率的系统电容电流测量方法误差分析 被引量:1
19
作者 张帆 薛永端 徐丙垠 《电力系统自动化》 EI CSCD 北大核心 2023年第2期164-172,共9页
在谐振接地系统中,系统电容电流的精确测量是接地故障消弧及保护的基础,测量方法的误差分析就显得至关重要。针对利用熄弧后暂态信息的谐振接地系统电容电流测量方法,研究发现影响该测量方法误差的主要因素为消弧线圈电流和熄弧后暂态... 在谐振接地系统中,系统电容电流的精确测量是接地故障消弧及保护的基础,测量方法的误差分析就显得至关重要。针对利用熄弧后暂态信息的谐振接地系统电容电流测量方法,研究发现影响该测量方法误差的主要因素为消弧线圈电流和熄弧后暂态过程主谐振频率测量精度,通过双变量线性规划的图解法分析了主谐振频率测量误差,用于校验系统电容电流的测量结果是否满足相关标准和规程要求。结果表明,考虑到谐振接地系统的规模与现场运行情况,建议主谐振频率测量允许误差统一取0.100 Hz。通过建模仿真验证了该误差分析方法的有效性,同时该方法也适用于不同系统失谐度和不同过渡电阻的情况,具有较强的可迁移性。 展开更多
关键词 谐振接地系统 系统电容电流 接地故障 主谐振频率 测量误差
下载PDF
基于首行波主频分量的柔性直流输电线路单端量行波保护
20
作者 邓丰 张振 +4 位作者 钟航 曾哲 冯思旭 曾祥君 潘一彬 《中国电机工程学报》 EI CSCD 北大核心 2023年第15期5797-5807,共11页
基于传统柔性直流输电线路行波保护存在耐过渡电阻能力不足,保护整定缺乏依据的问题。该文首先分析区内、外故障保护安装处首行波频率分量的衰减特征,揭示区内故障首行波频率分量衰减规律,区内、外故障首行波频率分量衰减差异性。然后,... 基于传统柔性直流输电线路行波保护存在耐过渡电阻能力不足,保护整定缺乏依据的问题。该文首先分析区内、外故障保护安装处首行波频率分量的衰减特征,揭示区内故障首行波频率分量衰减规律,区内、外故障首行波频率分量衰减差异性。然后,深入分析保护安装处故障首行波解析式,增强高频分量在能量计算中的影响,构造出能够反映故障位置和线路边界衰减特性的首行波主频分量。首行波主频分量解析式表明主频分量随故障距离增加而减小,区内、外故障首行波主频分量存在显著差异。在此基础上,提出一种基于首行波主频分量衰减特征的单端量行波保护方法,该方法充分利用了首行波全频段信息,原理上不受过渡电阻的影响且主频分量解析式也为保护阈值整定提供了理论依据。仿真结果表明所提保护方案能够快速准确识别区内、外故障,首行波主频分量能有效反映故障位置,整定简单易行,耐过渡电阻能力较强,在不同网络拓扑结构下具有较强的适应性。 展开更多
关键词 柔性直流输电 行波衰减特征 主频分量 过渡电阻 单端量保护
下载PDF