Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations ma...Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.展开更多
Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of con...Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study.展开更多
When an additional frequency control is implemented in the voltage source converter-based multi-terminal high voltage direct current(VSC-MTDC)system,the DC grid is capable of responding to a frequency disturbance in t...When an additional frequency control is implemented in the voltage source converter-based multi-terminal high voltage direct current(VSC-MTDC)system,the DC grid is capable of responding to a frequency disturbance in the AC system.However,the original additional frequency control may cause the DC voltage to exceed the limit when providing power for a severe frequency disturbance,threatening the security of the DC system.A novel dynamic additional frequency control strategy for the VSC-MTDC system is developed based on the relationship between the DC voltage and the frequency droop coefficient.A dynamic frequency droop coefficient is designed to adaptively adjust the support power of the DC grid,balancing the frequency regulation of the disturbed AC system and the voltage stability of the DC grid.A DC voltage recovery method based on multi-converter cooperation is proposed to cope with the DC voltage deviation caused by the additional frequency control.Simulations validate the advantages and satisfactory performance of the proposed method during power disturbances with different severities and for the process of DC voltage recovery.展开更多
基金This work is jointly supported by the National Key R&D Programme of China(No.2017YFB0902000)the National Natural Science Foundation of China(No.U1766206)the Science and Technology Programme of the State Grid Corporation(No.52110418000P).
文摘Frequency droop control is widely used in permanent magnet synchronous generators(PMSGs)based wind turbines(WTs)for grid frequency support.However,under frequency deviations,significant DC-link voltage fluctuations may occur during the transient process due to sudden changes in real power of such WTs.To address this issue,a current feedforward control strategy is proposed for PMSG-based WTs to reduce DC-link voltage fluctuations when the WTs are providing frequency support under grid frequency deviations.Meanwhile,the desired frequency support capability of the PMSG-based WTs can be ensured.Simulation results verify the rationality of the analysis and the effectiveness of the proposed control method.
基金the National Natural Science Foundation of China(51922061)the Science and Technology Project of State Grid Corporation of China(SGZJ0000KXJS1900418).
文摘Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study.
基金supported by the Science and Technology Project of SGCC (SGZJ0000KXJS1900419).
文摘When an additional frequency control is implemented in the voltage source converter-based multi-terminal high voltage direct current(VSC-MTDC)system,the DC grid is capable of responding to a frequency disturbance in the AC system.However,the original additional frequency control may cause the DC voltage to exceed the limit when providing power for a severe frequency disturbance,threatening the security of the DC system.A novel dynamic additional frequency control strategy for the VSC-MTDC system is developed based on the relationship between the DC voltage and the frequency droop coefficient.A dynamic frequency droop coefficient is designed to adaptively adjust the support power of the DC grid,balancing the frequency regulation of the disturbed AC system and the voltage stability of the DC grid.A DC voltage recovery method based on multi-converter cooperation is proposed to cope with the DC voltage deviation caused by the additional frequency control.Simulations validate the advantages and satisfactory performance of the proposed method during power disturbances with different severities and for the process of DC voltage recovery.