To avoid the secondary frequency dip caused by the steep drop of the electrical power of wind turbines(WTs)at the end of frequency support stage,the torque limit-based iner-tial control(TLIC)method sets the power refe...To avoid the secondary frequency dip caused by the steep drop of the electrical power of wind turbines(WTs)at the end of frequency support stage,the torque limit-based iner-tial control(TLIC)method sets the power reference as a linear function of rotor speed,rather than the step form for the step-wise inertial control.However,the compensation effect on the frequency nadir(FN)caused by the load surge is weakened as the TLIC power is no longer in the step form.Specifically,the maximum point of the frequency response component(FRC)contributed by TLIC occurs earlier than the minimum point of FRC corresponding to the load surge,so that the FN cannot be adequately raised.Therefore,this paper first investigates the relation between the peak and nadir times of FRCs stimulated by the TLIC and load power.On this basis,with the compensation principle of matching the peak and nadir times of FRCs,the improved TLIC method based on delayed support is proposed.Finally,the effectiveness of the proposed method is validated via the experiments on the test bench of wind-integrated power system.展开更多
The paper presents results from a study of a series-connected single-phase APF (active power filter) with a control system based on hysteresis control, both with and without limitation of the maximum switching frequ...The paper presents results from a study of a series-connected single-phase APF (active power filter) with a control system based on hysteresis control, both with and without limitation of the maximum switching frequency. The general purpose of the series APF is to eliminate the low order harmonics of the source (grid) voltage. The filter operation at limited and unlimited maximum switching frequency is explained and it is described using building blocks and time diagrams illustrating the tracking down of the reference curve. Waveforms from the computer simulation and waveforms from the experimental tests of the filter are presented also for the two situations. Operations at limited and unlimited maximum switching frequency are compared regarding the quality of the voltage across the load, the complexity of the implementation of the control system, and the electromagnetic compatibility. The investigation proved capability of the series APF to achieve its general purpose using the hysteresis control methods studied (limited and unlimited switching frequency).展开更多
For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motio...For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.展开更多
基金supported by the National Natural Science Foundation of China(No.51977111)the“Six Talent Peaks”High-level Talent Project in Jiangsu Province(No.XNY-025)+1 种基金the Special Fund of Jiangsu Province for Transformation of Scientific and Technological Achievements(No.BA2019045)the Jiangsu Qinglan Project。
文摘To avoid the secondary frequency dip caused by the steep drop of the electrical power of wind turbines(WTs)at the end of frequency support stage,the torque limit-based iner-tial control(TLIC)method sets the power reference as a linear function of rotor speed,rather than the step form for the step-wise inertial control.However,the compensation effect on the frequency nadir(FN)caused by the load surge is weakened as the TLIC power is no longer in the step form.Specifically,the maximum point of the frequency response component(FRC)contributed by TLIC occurs earlier than the minimum point of FRC corresponding to the load surge,so that the FN cannot be adequately raised.Therefore,this paper first investigates the relation between the peak and nadir times of FRCs stimulated by the TLIC and load power.On this basis,with the compensation principle of matching the peak and nadir times of FRCs,the improved TLIC method based on delayed support is proposed.Finally,the effectiveness of the proposed method is validated via the experiments on the test bench of wind-integrated power system.
文摘The paper presents results from a study of a series-connected single-phase APF (active power filter) with a control system based on hysteresis control, both with and without limitation of the maximum switching frequency. The general purpose of the series APF is to eliminate the low order harmonics of the source (grid) voltage. The filter operation at limited and unlimited maximum switching frequency is explained and it is described using building blocks and time diagrams illustrating the tracking down of the reference curve. Waveforms from the computer simulation and waveforms from the experimental tests of the filter are presented also for the two situations. Operations at limited and unlimited maximum switching frequency are compared regarding the quality of the voltage across the load, the complexity of the implementation of the control system, and the electromagnetic compatibility. The investigation proved capability of the series APF to achieve its general purpose using the hysteresis control methods studied (limited and unlimited switching frequency).
文摘For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.