This paper presents design, analysis and simulation performance of an active power controller for stable and reliable operation of a micro-grid system. Power balance between generation and consumer is a critical issue...This paper presents design, analysis and simulation performance of an active power controller for stable and reliable operation of a micro-grid system. Power balance between generation and consumer is a critical issue for stable and reliable operation of the micro-grid systems. This issue becomes more critical when a micro-grid system contains stochastic nature distributed generations such as wind and solar because their output power changes non-uniformly. In order to achieve accurate and fast power balance in such a micro-grid system, power in the system has to be regulated continuously. Such an objective can be achieved using droop based alternating current control technique. Because the droop characteristic employed into the developed controller initiates determining the power deviation in the system which is continuously regulated by controlling the current flow into dump power resistors. The designed controller is simulated for the operation of a micro-grid system in stand-alone mode under various operating conditions. The simulated results show the ability of the developed controller for stable and reliable operation of the micro-grid that contains renewable sources. The experimental development of the micro-grid system and the testing of the developed active power controller are presented in PART II of this paper.展开更多
During this decade,many countries have experienced natural and accidental disasters,such as typhoons,floods,earthquakes,and nuclear plant accidents,causing catastrophic damage to infrastructures.Since the end of 2019,...During this decade,many countries have experienced natural and accidental disasters,such as typhoons,floods,earthquakes,and nuclear plant accidents,causing catastrophic damage to infrastructures.Since the end of 2019,all countries of the world are struggling with the COVID-19 and pursuing countermeasures,including inoculation of vaccine,and changes in our lifestyle and social structures.All these experiences have made the residents in the affected regions keenly aware of the need for new infrastructures that are resilient and autonomous,so that vital lifelines are secured during calamities.A paradigm shift has been taking place toward reorganizing the energy social service management in many countries,including Japan,by effective use of sustainable energy and new supply schemes.However,such new power sources and supply schemes would affect the power grid through intermittency of power output and the deterioration of power quality and service.Therefore,new social infrastructures and novel management systems to supply energy and social service will be required.In this paper,user-friendly design,operation and control assist tools for resilient microgrids and autonomous communities are proposed and applied to the standard microgrid to verify its effectiveness and performance.展开更多
For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motio...For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.展开更多
In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control...In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control were both analyzed. Besides, the transient simula- tion of no-load model and generation model of the BDFG have been developed on the MATLAB/Simulink platform. The test results during cutting-in grid confirmed the good dynamic performance of grid synchronization and effective power control approach for the BDFG-based variable speed wind turbines.展开更多
随着海上风电、光伏等新能源的大规模建设,产生了直流输电、交直流互联和储能的应用需求。目前储能技术的研究和应用主要集中于交流储能领域。模块化多电平电池储能系统(modular multilevel converter based battery energy storage sys...随着海上风电、光伏等新能源的大规模建设,产生了直流输电、交直流互联和储能的应用需求。目前储能技术的研究和应用主要集中于交流储能领域。模块化多电平电池储能系统(modular multilevel converter based battery energy storage system,MMC-BESS)虽然在交直流互联的同时,实现了储能的功能,但电池中流过的工频、二倍频等脉动电流成分对电池寿命有潜在影响,且传统的模块化多电平(modular multilevel converter,MMC)换流站的改造成本高。本工作提出的直流直挂储能装置将换流和储能分离,电池电流仅为直流和高频脉动成分,工况对电池友好,且直流直挂储能系统需要电池单体数量仅为MMC-BESS的1/6,成本低。对直流直挂储能装置的拓扑结构及工作原理进行分析;对级联子模块的数量和参数进行设计;基于载波移相调制,推导直流纹波电流,进而对并网电感参数进行设计;建立直流直挂储能装置的数学模型,推导控制模型,根据控制框图进行功率控制。最后,通过仿真和样机实验,验证该半桥拓扑级联型直流直挂储能装置设计的可行性及正确性。实验证明,该设计和控制方法效果良好,对高压大容量直流直挂储能装置的设计有一定参考价值。展开更多
文摘This paper presents design, analysis and simulation performance of an active power controller for stable and reliable operation of a micro-grid system. Power balance between generation and consumer is a critical issue for stable and reliable operation of the micro-grid systems. This issue becomes more critical when a micro-grid system contains stochastic nature distributed generations such as wind and solar because their output power changes non-uniformly. In order to achieve accurate and fast power balance in such a micro-grid system, power in the system has to be regulated continuously. Such an objective can be achieved using droop based alternating current control technique. Because the droop characteristic employed into the developed controller initiates determining the power deviation in the system which is continuously regulated by controlling the current flow into dump power resistors. The designed controller is simulated for the operation of a micro-grid system in stand-alone mode under various operating conditions. The simulated results show the ability of the developed controller for stable and reliable operation of the micro-grid that contains renewable sources. The experimental development of the micro-grid system and the testing of the developed active power controller are presented in PART II of this paper.
文摘During this decade,many countries have experienced natural and accidental disasters,such as typhoons,floods,earthquakes,and nuclear plant accidents,causing catastrophic damage to infrastructures.Since the end of 2019,all countries of the world are struggling with the COVID-19 and pursuing countermeasures,including inoculation of vaccine,and changes in our lifestyle and social structures.All these experiences have made the residents in the affected regions keenly aware of the need for new infrastructures that are resilient and autonomous,so that vital lifelines are secured during calamities.A paradigm shift has been taking place toward reorganizing the energy social service management in many countries,including Japan,by effective use of sustainable energy and new supply schemes.However,such new power sources and supply schemes would affect the power grid through intermittency of power output and the deterioration of power quality and service.Therefore,new social infrastructures and novel management systems to supply energy and social service will be required.In this paper,user-friendly design,operation and control assist tools for resilient microgrids and autonomous communities are proposed and applied to the standard microgrid to verify its effectiveness and performance.
文摘For a large-scale high voltage direct current (HVDC)asynchronous interconnected power grid, the frequency issue atthe power sending side under DC faults is a crucial problem.To solve this problem, based on rotor motion equations, theeffect of unbalanced power on the system frequency under DCfaults is analyzed. The characteristics and dynamic developmentprocess of frequencies after the injection of disturbances areanalyzed. In addition, the actions and coordinated strategies ofvarious frequency control measures are also investigated. Basedon the testing projects of an asynchronous interconnection in theChina Southern Power Grid (CSG), the frequency features arestudied according to the measured PMU data. The outcome showsthat the frequency problem of the Yunnan Power Grid after anasynchronous interconnection can be solved and controlled. Italso shows that the frequency limit control (FLC) is importantfor the frequency regulation of large scale HVDC asynchronousinterconnected DC power grids. As demonstrated, DC FLC caneffectively suppress the deviation of the transient frequency.However, reasonable frequency regulation parameters shouldbe set and other area frequency control measures should becoordinated to maintain the frequency stability of the system.
文摘In this paper, based on the analysis of the mathematical model in a common synchronous reference frame of the brushless doubly-fed generator (BDFG), the grid connection strategy and maximum energy extraction control were both analyzed. Besides, the transient simula- tion of no-load model and generation model of the BDFG have been developed on the MATLAB/Simulink platform. The test results during cutting-in grid confirmed the good dynamic performance of grid synchronization and effective power control approach for the BDFG-based variable speed wind turbines.
文摘随着海上风电、光伏等新能源的大规模建设,产生了直流输电、交直流互联和储能的应用需求。目前储能技术的研究和应用主要集中于交流储能领域。模块化多电平电池储能系统(modular multilevel converter based battery energy storage system,MMC-BESS)虽然在交直流互联的同时,实现了储能的功能,但电池中流过的工频、二倍频等脉动电流成分对电池寿命有潜在影响,且传统的模块化多电平(modular multilevel converter,MMC)换流站的改造成本高。本工作提出的直流直挂储能装置将换流和储能分离,电池电流仅为直流和高频脉动成分,工况对电池友好,且直流直挂储能系统需要电池单体数量仅为MMC-BESS的1/6,成本低。对直流直挂储能装置的拓扑结构及工作原理进行分析;对级联子模块的数量和参数进行设计;基于载波移相调制,推导直流纹波电流,进而对并网电感参数进行设计;建立直流直挂储能装置的数学模型,推导控制模型,根据控制框图进行功率控制。最后,通过仿真和样机实验,验证该半桥拓扑级联型直流直挂储能装置设计的可行性及正确性。实验证明,该设计和控制方法效果良好,对高压大容量直流直挂储能装置的设计有一定参考价值。