期刊文献+
共找到10,798篇文章
< 1 2 250 >
每页显示 20 50 100
Optimization of Control Loops and Operating Parameters for Three-Phase Separators Used in Oilfield Central Processing Facilities
1
作者 Zhenfeng Li Yaqiao Li Guangjun Wei 《Fluid Dynamics & Materials Processing》 EI 2023年第3期635-649,共15页
In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to... In this study,the Stokes formula is used to analyze the separation effect of three-phase separators used in a Oilfield Central Processing Facility.The considered main influencing factors include(but are not limited to)the typical size of oil and water droplets,the residence time and temperature of fluid and the dosage of demulsifier.Using the“Specification for Oil and Gas Separators”as a basis,the control loops and operating parameters of each separator are optimized Considering the Halfaya Oilfield as a testbed,it is shown that the proposed approach can lead to good results in the production stage. 展开更多
关键词 Distributed control system(DCS) three-phase separator control loop operating parameter
下载PDF
Design and implementation of digital closed-loop drive control system of a MEMS gyroscope 被引量:5
2
作者 王晓雷 李宏生 杨波 《Journal of Southeast University(English Edition)》 EI CAS 2012年第1期35-40,共6页
In order to effectively control the working state of the gyroscope in drive mode, the drive characteristics of the micro electromechanical system (MEMS) gyroscope are analyzed in principle. A novel drive circuit for... In order to effectively control the working state of the gyroscope in drive mode, the drive characteristics of the micro electromechanical system (MEMS) gyroscope are analyzed in principle. A novel drive circuit for the MEMS gyroscope in digital closed-loop control is proposed, which utilizes a digital phase-locked loop (PLL) in frequency control and an automatic gain control (AGC) method in amplitude control. A digital processing circuit with a field programmable gate array (FPGA) is designed and the experiments are carried out. The results indicate that when the temperature changes, the drive frequency can automatically track the resonant frequency of gyroscope in drive mode and that of the oscillating amplitude holds at a set value. And at room temperature, the relative deviation of the drive frequency is 0.624 ×10^-6 and the oscillating amplitude is 8.0 ×10^-6, which are 0. 094% and 18. 39% of the analog control program, respectively. Therefore, the control solution of the digital PLL in frequency and the AGC in amplitude is feasible. 展开更多
关键词 micro electromechanical system (MEMS) digitalgyroscope drive frequency phase-locked loop (PLL) oscillating amplitude automatic gain control (AGC)
下载PDF
EFFECTIVE DOUBLE LOOP CONTROL FOR A SQUARE WAVE BRUSHLESS DC MOTOR
3
作者 周波 李先祥 朱震莲 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1996年第2期34+30-33,共5页
A new type of brushless DC motor has been developed by using a square wave rare earth permanent magnet synchronous motor with its double loop control circuit. The double loop control scheme of the drive system yie... A new type of brushless DC motor has been developed by using a square wave rare earth permanent magnet synchronous motor with its double loop control circuit. The double loop control scheme of the drive system yields a combination of desired characteristics including simplified control structure, small ripple torque, high speed accuracy, wide operating speed range, and fast dynamic response. Experimental results confirm excellent characteristics of the motor. 展开更多
关键词 synchronous motors speed control systems INVERTERS brushless DC motor double loop control square wave motors
下载PDF
A review of control loop monitoring and diagnosis:Prospects of controller maintenance in big data era 被引量:7
4
作者 Xinqing Gao Fan Yang +1 位作者 Chao Shang Dexian Huang 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2016年第8期952-962,共11页
Owing to wide applications of automatic control systems in the process industries, the impacts of controller performance on industrial processes are becoming increasingly significant. Consequently, controller maintena... Owing to wide applications of automatic control systems in the process industries, the impacts of controller performance on industrial processes are becoming increasingly significant. Consequently, controller maintenance is critical to guarantee routine operations of industrial processes. The workflow of controller maintenance generally involves the following steps: monitor operating controller performance and detect performance degradation, diagnose probable root causes of control system malfunctions, and take specific actions to resolve associated problems. In this article, a comprehensive overview of the mainstream of control loop monitoring and diagnosis is provided, and some existing problems are also analyzed and discussed. From the viewpoint of synthesizing abundant information in the context of big data, some prospective ideas and promising methods are outlined to potentially solve problems in industrial applications. 展开更多
关键词 control loop performance assessment Industrial ALARM system Process knowledge ROOT CAUSE diagnosis BIG data
下载PDF
DS-CDMA system outer loop power control and improvement for multi-service 被引量:3
5
作者 Guan Mingxiang Guo Qing Li Xing 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第3期453-460,共8页
When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (S... When a new user accesses the CDMA system, the load will change drastically, and therefore, the advanced outer loop power control (OLPC) technology has to be adopted to enrich the target signal interference ratio (Silt) and improve the system performance. The existing problems about DS-CDMA outer loop power control for multi-service are introduced and the power control theoretical model is analyzed. System simulation is adopted on how to obtain the theoretical performance and parameter optimization of the power control algorithm. The OLPC algorithm is improved and the performance comparisons between the old algorithm and the improved algorithm are given. The results show good performance of the improved OLPC algorithm and prove the validity of the improved method for multi-service. 展开更多
关键词 DS-CDMA outer loop power control MULTI-SERVICE performance.
下载PDF
Coupling vibration analysis of high-speed maglev train-viaduct systems with control loop failure 被引量:4
6
作者 GUO Wei CHEN Xue-yuan +7 位作者 YE Yi-tao HU Yao LUO Yi-kai SHAO Ping HUANG Ren-qiang WANG Xu-yixin GUO Zhen TAN Sui 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第8期2771-2790,共20页
The risk of failure of the control loop can occur when a high-speed maglev train runs on viaduct.Meanwhile,the failure of the levitation magnets which balances the gravity of the maglev train could cause the train col... The risk of failure of the control loop can occur when a high-speed maglev train runs on viaduct.Meanwhile,the failure of the levitation magnets which balances the gravity of the maglev train could cause the train collision with track.To study the dynamic response of the train and the viaduct when the levitation magnet control loop failure occurs,a high-speed maglev train-viaduct coupling model,which includes a maglev controller fitted by measured force-gap data and considers the actual structure of train and viaduct,is established.Then the accuracy and effectiveness of the established approach are validated by comparing the computed dynamic responses and frequencies with the measurement results.After that,the dynamic responses of maglev train and viaduct are discussed under normal operation and control loop failures,and the most disadvantageous combination of control loop failures is obtained.The results show that when a single control loop fails,it only has a great influence on the failed electromagnet,and the maglev response of adjacent electromagnets has no obvious change and no collision occurs.But there is a risk of rail collisions when the dual control loop fails. 展开更多
关键词 high-speed maglev train control loop failure coupling vibration maglev control
下载PDF
Reliability and sensitivity analysis of loop-designed security and stability control system in interconnected power systems 被引量:4
7
作者 Shenghu Li Huimin Zhou +2 位作者 Yunsong Yan Wei Han Jianfeng Ren 《Global Energy Interconnection》 EI CAS CSCD 2022年第5期501-511,共11页
Security and stability control system(SSCS)in power systems involves collecting information and sending the decision from/to control stations at different layers;the tree structure of the SSCS requires more levels.Fai... Security and stability control system(SSCS)in power systems involves collecting information and sending the decision from/to control stations at different layers;the tree structure of the SSCS requires more levels.Failure of a station or channel can cause all the execution stations(EXs)to be out of control.The randomness of the controllable capacity of the EXs increases the difficulty of the reliability evaluation of the SSCS.In this study,the loop designed SSCS and reliability analysis are examined for the interconnected systems.The uncertainty analysis of the controllable capacity based on the evidence theory for the SSCS is proposed.The bidirectional and loop channels are introduced to reduce the layers and stations of the existing SSCS with tree configuration.The reliability evaluation and sensitivity analysis are proposed to quantify the controllability and vulnerable components for the SSCS in different configurations.By aiming at the randomness of the controllable capacity of the EXs,the uncertainty analysis of the controllable capacity of the SSCS based on the evidence theory is proposed to quantify the probability of the SSCS for balancing the active power deficiency of the grid. 展开更多
关键词 Security and stability control system(SSCS) loop design controlLABILITY VULNERABILITY Interconnected power systems Evidence theory Uncertainty controllable capacity.
下载PDF
Recent developments on applications of sequential loop closing and diagonal dominance control schemes to industrial multivariable system 被引量:4
8
作者 A.H.Mazinan M.F.Kazemi 《Journal of Central South University》 SCIE EI CAS 2013年第12期3401-3420,共20页
With a focus on an industrial multivariable system, two subsystems including the flow and the level outputs are analysed and controlled, which have applicability in both real and academic environments. In such a case,... With a focus on an industrial multivariable system, two subsystems including the flow and the level outputs are analysed and controlled, which have applicability in both real and academic environments. In such a case, at first, each subsystem is distinctively represented by its model, since the outcomes point out that the chosen models have the same behavior as corresponding ones. Then, the industrial multivariable system and its presentation are achieved in line with the integration of these subsystems, since the interaction between them can not actually be ignored. To analyze the interaction presented, the Gershgorin bands need to be acquired, where the results are used to modify the system parameters to appropriate values. Subsequently, in the view of modeling results, the control concept in two different techniques including sequential loop closing control(SLCC) scheme and diagonal dominance control(DDC) schemes is proposed to implement on the system through the Profibus network, as long as the OPC(OLE for process control) server is utilized to communicate between the control schemes presented and the multivariable system. The real test scenarios are carried out and the corresponding outcomes in their present forms are acquired. In the same way, the proposed control schemes results are compared with each other, where the real consequences verify the validity of them in the field of the presented industrial multivariable system control. 展开更多
关键词 multivariable system diagonal dominance control sequential loop closing control Profibus network OPC server orifice relation interaction analysis Gershogerin bands non-minimum phase system
下载PDF
Transfigured Loop Shaping Controller and its Application to Underwater Vehicle 被引量:1
9
作者 Xian-Ku Zhang Yi-Cheng Jin 《International Journal of Automation and computing》 EI 2005年第1期48-51,共4页
A kind of transfigured loop shaping controller is presented in this paper. A transfigured loop shaping system puts a controller K in a feedback loop, while putting the dc gain of the controller K on the reference sign... A kind of transfigured loop shaping controller is presented in this paper. A transfigured loop shaping system puts a controller K in a feedback loop, while putting the dc gain of the controller K on the reference signal line. It is shown through frequency domain analysis and simulation that a transfigured controller can improve the dynamic behavior of a system. The transfigured loop shaping controller method is simple and effective and corresponds to the mixed sensitivity method of robust control theory, which improves the behavior of a system by iterative tuning of weighting functions. Satisfactory control results are obtained when it is applied to the design of an underwater vehicle. Keywords Loop shaping controller - underwater vehicle - transfiguration Zhang Xianku graduated from Beijing Institute of Clothing Technology, China, in 1990. He received the M. S. degree from Dalian Maritime University (DMU), China, in 1993 and the Ph.D. degree from DMU, in 1998. He is currently a professor at the Laboratory of Simulation and Control of Navigation Systems, Dalian Maritime University. His research interests include ship motion control and robust control.Jin Yicheng graduated from Zhejiang University, China, in 1967. He is currently a professor at the Laboratory of Simulation and Control of Navigation Systems, Dalian Maritime University. His research interests include simulating system of ship steering and visual control. 展开更多
关键词 loop shaping controller underwater vehicle transfiguration
下载PDF
Analysis and design of DSP-based dual-loop controlled UPS inverters 被引量:2
10
作者 吴燮华 言超 《Journal of Zhejiang University Science》 EI CSCD 2003年第3期276-280,共5页
This paper presents a novel digital dual-loop control scheme of the PWM(PUlse width modulate)inverter. Deadbeat control technique are employed to enhance the performance. Half switching period delayed sampling and con... This paper presents a novel digital dual-loop control scheme of the PWM(PUlse width modulate)inverter. Deadbeat control technique are employed to enhance the performance. Half switching period delayed sampling and control timing strategy is used to improve the system dynamic response. Simulation and experimental results presented in the paper verified the validity of the proposed control scheme. 展开更多
关键词 Digital control Inductor current mode Dual loop
下载PDF
Open loop control of vortex-induced vibration of a circular cylinder 被引量:4
11
作者 陈志华 范宝春 +1 位作者 周本谋 李鸿志 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第4期1077-1083,共7页
In this paper both numerical and experimental investigations have been carried out to suppress the vortex-induced vibration (VIV) of a circular cylinder in an electrically low-conducting fluid. The electromagnetic f... In this paper both numerical and experimental investigations have been carried out to suppress the vortex-induced vibration (VIV) of a circular cylinder in an electrically low-conducting fluid. The electromagnetic forces (Lorentz forces) in the azimuthal direction were generated through the mounted electrodes and magnets locally on the surface of the cylinder, which have been proved having an accelerating effect to the fluid on the surface of the cylinder. Results of computations are presented for synchronous vibration phenomenon of a cylinder at Re = 200, which are in good agreement with previous computational results. With the Lorentz forces loaded, the VIV of the cylinder has been suppressed successfully. Experimental results have also shown the same tendency and are in reasonable agreement with the numerical results. 展开更多
关键词 vortex-induced vibration open-loop control flow control Lorentz force
下载PDF
Dynamics and adaptive control of a dual-arm space robot with closed-loop constraints and uncertain inertial parameters 被引量:20
12
作者 Ying-Hong Jia Quan Hu Shi-Jie Xu 《Acta Mechanica Sinica》 SCIE EI CAS CSCD 2014年第1期112-124,共13页
A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of contro... A dynamics-based adaptive control approach is proposed for a planar dual-arm space robot in the presence of closed-loop constraints and uncertain inertial parameters of the payload. The controller is capable of controlling the po- sition and attitude of both the satellite base and the payload grasped by the manipulator end effectors. The equations of motion in reduced-order form for the constrained system are derived by incorporating the constraint equations in terms of accelerations into Kane's equations of the unconstrained system. Model analysis shows that the resulting equations perfectly meet the requirement of adaptive controller design. Consequently, by using an indirect approach, an adaptive control scheme is proposed to accomplish position/attitude trajectory tracking control with the uncertain parameters be- ing estimated on-line. The actuator redundancy due to the closed-loop constraints is utilized to minimize a weighted norm of the joint torques. Global asymptotic stability is proven by using Lyapunov's method, and simulation results are also presented to demonstrate the effectiveness of the proposed approach. 展开更多
关键词 Space robot Dynamics. Adaptive control Closed-loop constraint Parameter uncertainty - Kane's equation
下载PDF
A Software-in-the-Loop Implementation of Adaptive Formation Control for Fixed-Wing UAVs 被引量:5
13
作者 Jun Yang Ximan Wang +2 位作者 Simone Baldi Satish Singh Stefano Fari 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第5期1230-1239,共10页
This paper discusses the design and software-in-theloop implementation of adaptive formation controllers for fixedwing unmanned aerial vehicles(UAVs) with parametric uncertainty in their structure, namely uncertain ma... This paper discusses the design and software-in-theloop implementation of adaptive formation controllers for fixedwing unmanned aerial vehicles(UAVs) with parametric uncertainty in their structure, namely uncertain mass and inertia. In fact, when aiming at autonomous flight, such parameters cannot assumed to be known as they might vary during the mission(e.g.depending on the payload). Modeling and autopilot design for such autonomous fixed-wing UAVs are presented. The modeling is implemented in Matlab, while the autopilot is based on ArduPilot, a popular open-source autopilot suite. Specifically, the ArduP ilot functionalities are emulated in Matlab according to the Ardupilot documentation and code, which allows us to perform software-in-the-loop simulations of teams of UAVs embedded with actual autopilot protocols. An overview of realtime path planning, trajectory tracking and formation control resulting from the proposed platform is given. The software-inthe-loop simulations show the capability of achieving different UAV formations while handling uncertain mass and inertia. 展开更多
关键词 ArduPilot ADAPTIVE formation control FIXED-WING UAVs software-in-the-loop simulations
下载PDF
Outer Loop Power Control Algorithm Based on T-norms Information Fusion Technology in TD-SCDMA
14
作者 孙毅 李芹 唐良瑞 《China Communications》 SCIE CSCD 2011年第3期180-188,共9页
An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,t... An outer loop power control algorithm based on triangle norm(t-norm) information fusion technology is proposed in this paper.According to the difference between block error rate and bit error rate with target values,the membership function calculation and level dividing of the two differences are dealt with.And then t-norm operator is used to fuse the two membership function values to determine the adjustment step-size.The algorithm can acquire the optimal adjustment step-size in the light of the channel status and avoid the overshoot phenomenon of the existing outer power control methods.As a result,the block error rate can converge to the target value quickly.Experiment results verify the excellent property of the algorithm. 展开更多
关键词 outer loop power control BLER t-norm operator information fusion TD-SCDMA
下载PDF
H_∞Loop Shaping Control for Plasma Vertical Position Instability on QUEST
15
作者 刘晓龙 Kazuo NAKAMURA +12 位作者 Tatsuya YOSHISUE Osamu MITARAI Makoto HASEGAWA Kazutoshi TOKUNAGA 薛二兵 Hideki ZUSHI Kazuaki HANADA Akihide FUJISAWA Hiroshi IDEI Shoji KAWASAKI Hisatoshi NAKASHIMA Aki HIGASHIJIMA Kuniaki ARAKI 《Plasma Science and Technology》 SCIE EI CAS CSCD 2013年第3期295-299,共5页
QUEST has a divertor configuration with a high and a negative n-index, and the problem of plasma vertical position instability control in QUEST is still under extensive study for achieving high efficiency plasma. The ... QUEST has a divertor configuration with a high and a negative n-index, and the problem of plasma vertical position instability control in QUEST is still under extensive study for achieving high efficiency plasma. The instability we considered is that the toroidal plasma moves either up or down in the vacuum chamber until it meets the vessel wall and is extinguished. The actively controlled coils (HCU and HCL) outside the vacuum vessel are serially connected in feedback with a measurement of the plasma vertical position to provide stabilizing control. In this work, a robust controller is employed by using the loop synthesis method, and provides robust stability over a wide range of n-index. Moreover, the gain of the robust controller is lower than that of a typical proportional derivative (PD) controller in the operational frequency range; it indicates that the robust controller needs less power consumption than the PD controller does. 展开更多
关键词 vertical position instability robust control loop shaping QUEST
下载PDF
Study on a Closed-Loop Air-Fuel Control System of Gasoline Engines by Simulation
16
作者 张付军 赵长禄 +1 位作者 黄英 郝利军 《Journal of Beijing Institute of Technology》 EI CAS 2003年第3期296-301,共6页
In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model... In order to study the factors that influence the air fuel ratio(A/F), the amplitude and frequency of A/F fluctuation, to reform the control strategy, and to improve the efficiency of three way catalyst(TWC), a model of closed loop control system including the engine, air fuel mixing and transportation, oxygen sensor and controller, etc., is developed. Various factors that influence the A/F control are studied by simulation. The simulation results show that the reference voltage of oxygen sensor will influence the mean value of A/F ratio, the controller parameters will influence the amplitude of A/F fluctuation, and the operating conditions of the engine determine the frequency of A/F fluctuations, the amplitude of A/F fluctuation can be reduced to within demanded values by logical selection of the signal acquisition method and controller parameters. Higher A/F fluctuation frequency under high speed and load can be reduced through software delay in the controller. The A/F closed loop control system based on the simulation results, accompanied with a rare earth element TWC, gives a better efficiency of conversion against harmful emissions. 展开更多
关键词 air fuel ratio closed loop control SIMULATION
下载PDF
Open-closed Loop ILC Corrected with Angle Relationship of Output Vectors for Tracking Control of Manipulator 被引量:8
17
作者 WANG Hong-Bin WANG Yan 《自动化学报》 EI CSCD 北大核心 2010年第12期1758-1765,共8页
关键词 ILC 自动化 跟踪控制 仿真
下载PDF
Closed-loop control of weld penetration in keyhole plasma arc welding 被引量:2
18
作者 陈强 孙振国 +1 位作者 孙久文 王耀文 《中国有色金属学会会刊:英文版》 CSCD 2004年第1期116-120,共5页
To improve the penetrating ability and the welding quality of keyhole plasma arc welding, a novel penetration closed loop control system was established. In the system, welding current and plasma gas flow rate were se... To improve the penetrating ability and the welding quality of keyhole plasma arc welding, a novel penetration closed loop control system was established. In the system, welding current and plasma gas flow rate were selected as adjusting variables. The wavelet method was used to detect penetration status from welding arc voltage in real time. The control strategy of one keyhole per pulse was adapted to fulfill stable and high quality welding process. Experimental results show that the developed system can apparently increase the penetrating force of plasma arc and keyhole plasma arc welding is realized successfully in stainless steel with 10 mm in thickness. Moreover, the disturbances of gradual change and break change from 3 mm to 6 mm in thickness are come over due to the good response property of the developed system. 展开更多
关键词 焊缝 熔深 闭环控制 等离子弧焊 PAW
下载PDF
Study of measurement and control of free loop of hot steel strip in twin-roll strip casting
19
作者 YE Changhong FANG Yuan ZHANG Qing 《Baosteel Technical Research》 CAS 2018年第1期27-33,共7页
In the twin-roll strip casting process, hot cast strips can be broken or tom if the casting speed does not match the rolling speed. Usually, a certain length of hot steel strip is hung freely between the caster and ro... In the twin-roll strip casting process, hot cast strips can be broken or tom if the casting speed does not match the rolling speed. Usually, a certain length of hot steel strip is hung freely between the caster and rolling mill to deal with the effect of this speed difference. In this paper,the freely hanging hot steel strip is referred to as the free loop of hot steel strip. Accurately measuring and controlling the height of this free loop is the key factor in maintaining a stable casting operation. Several methods for measuring the loop height of a steel strip are discussed and a method for accurately measuring and controlling the free loop height of hot steel strip is presented. Based on the results of the casting loop quantity change curve, this control method is confirmed to be effective and able to meet the requirements of continuous casting strip production. 展开更多
关键词 twin-roll strip casting free loop height of free loop measurement method measurement error control of free loop height
下载PDF
Application of Single Neuron Adaptive PID Regulators with Auto-tuning Gain in Industrial Parameter(Pressure)Closed-loop Process Control Systems 被引量:1
20
作者 Shaoyuan Sun Huade Li +1 位作者 Bin Qian Jianping Wei(Information Engineering School, University of Science and Technology Beijing, Beijing 100083, China) 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 1999年第2期152-153,共2页
A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of ind... A type of single neuron adaptive PID regulator with auto-tuning gain is proposed and applied to the work control of fans, waterpumps and air-pressers etc. in Handan Iron & Steel Compel China. The robusthess of induStrial parameter closed-loop process controlsystems is improved, and the work quality of the systems bettered. 展开更多
关键词 single neuron GAIN adaptiVe PID regulator pressure closed-loop control
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部