In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer an...In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer and winter. The results show that while the volume of the treated fresh-air is 125 m3/h,in summer,at the outlet of the device,the air temperature is 21.5-24.0 ℃,the air humidity ratio is about 17 g/kg,the greatest temperature drop is about 9 ℃ ,and the largest dehydration quantity is about 6 g/kg. In winter,at the outlet of the device,the air temperature is 15-17 ℃,the air humidity ratio is about 11 g/kg,the largest temperature rise is about 11 ℃,and the largest humidification quantity is about 6 g/kg. Therefore,the application of this new fresh-air handing device can take full advantage of the natural energy,thus effectively reduce the traditional energy consumption for fresh-air handing.展开更多
Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero ...Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.展开更多
“双碳”目标背景下,为解决热电联产机组“以热定电”模式导致的大规模弃风问题,本文提出基于先进绝热压缩空气储能电站(advanced adiabatic compressed air energy storage,AA-CAES)和综合需求响应的综合能源系统(integrated energy sy...“双碳”目标背景下,为解决热电联产机组“以热定电”模式导致的大规模弃风问题,本文提出基于先进绝热压缩空气储能电站(advanced adiabatic compressed air energy storage,AA-CAES)和综合需求响应的综合能源系统(integrated energy system,IES)供暖期弃风消纳策略。首先,在“源-储”两侧建立热电联产机组与AA-CAES电站耦合运行模型,分析耦合运行实现热电解耦机理;其次,在“荷”侧引入价格型和替代型需求响应机制来探寻负荷侧优化系统调度潜力;然后,在IES中引入碳捕集系统和阶梯型碳交易机制来约束碳排放,并在碳排放量最少、综合成本最低为目标构建IES运行基础上,引入模糊机会规划约束模型来分析风、光不确定性对系统调度影响;最后,利用西北某地区实际数据进行算例验证。结果表明:热电机组与AA-CAES电站耦合运行相较于未耦合运行可提高风电消纳率84.55%、降低总成本11.42%、减少碳排放20.28%;综合需求响应机制的引入可进一步提高风电消纳率35.00%、降低总成本20.93%、减少碳排放24.43%;风光不确定性的上升会提高与外部电网的交互成本。展开更多
辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的...辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的室内热舒适和房间能耗。结果表明:3种辐射供冷模型下,室内的相对湿度都在40%~60%舒适范围内;墙面和顶板辐射供冷的预测平均投票(Predicted Mean Vote, PMV)值在0.25~0.50之间,而预测不满意百分数(Predicted Percentage of Dissatisfied, PPD)值小于10%,PMV-PPD指标达到了Ⅰ级,热舒适性较好;在设计日运行时间内,地面、顶板、墙面辐射供冷的总能耗分别为5.59、6.23、6.16 kW·h,地面辐射供冷的节能性最好。展开更多
为加强先进绝热压缩空气储能(Advanced Adiabatic Compressed Air Energy Storage,AA-CAES)与综合能源系统(Integrated Energy Systems,IES)的多能互补协同,提高系统运行效率,文中提出了一种含AA-CAES能源站的电-热综合能源系统优化运...为加强先进绝热压缩空气储能(Advanced Adiabatic Compressed Air Energy Storage,AA-CAES)与综合能源系统(Integrated Energy Systems,IES)的多能互补协同,提高系统运行效率,文中提出了一种含AA-CAES能源站的电-热综合能源系统优化运行方法。构建了含AA-CAES能源站的IES基本调度架构,详细分析了AA-CAES装置在压缩和膨胀工况下的储热、换热及供热等特性,建立了AA-CAES电热联供联储运行模型;基于热网管道传热延迟和损耗等动态特性,建立了考虑供热网储热惯性的热网方程;在此基础上,考虑了用户侧可调度资源,提出了计及综合需求响应的含AA-CAES能源站的IES日前优化运行模型;在修改的IEEE 33节点配电网和巴厘岛32节点区域供热网进行算例分析。仿真结果表明,所提方法可有效降低IES运行成本,提高IES可再生能源消纳能力。展开更多
基金Project(2006BAJ01A02) supported by the Chinese of Science and Technology during the 11th Five-Year Plan Period
文摘In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer and winter. The results show that while the volume of the treated fresh-air is 125 m3/h,in summer,at the outlet of the device,the air temperature is 21.5-24.0 ℃,the air humidity ratio is about 17 g/kg,the greatest temperature drop is about 9 ℃ ,and the largest dehydration quantity is about 6 g/kg. In winter,at the outlet of the device,the air temperature is 15-17 ℃,the air humidity ratio is about 11 g/kg,the largest temperature rise is about 11 ℃,and the largest humidification quantity is about 6 g/kg. Therefore,the application of this new fresh-air handing device can take full advantage of the natural energy,thus effectively reduce the traditional energy consumption for fresh-air handing.
基金the support from National Natural Sci-ence Foundation of China(52276178)Natural Science Foundation of Jiangsu Province,China(BK20200373).
文摘Building fresh air supply needs to meet certain regulations and fit people’s ever-growing indoor air quality de-mand.However,fresh air handling requires huge energy consumption that goes against the goal of net-zero energy buildings.Thus,in this work,an adaptive fresh air pre-handling system is designed to reduce the cool-ing and heating loads of HVAC system.The sky-facing surface of the system uses electrochromic mechanism to manipulate the optical properties and thus make full use of solar energy(solar heating)and deep space cold source(radiative cooling)by switching between heating and cooling modes.In the cooling mode,the sky-facing surface shows a transmittance of down to zero,while the reflectance is high at 0.89 on average.In the heating mode,the electrochromic glass is highly transparent,allowing the sunlight to reach the solar heat absorber.To obtain the energy-saving potential under different climates,six cities were selected from various climate regions in China.Results show that the adaptive fresh air pre-handling system can be effective in up to 55.4%time of a year.The maximum energy-saving ratios for medium office,warehouse,and single-family house can reach up to 11.52%,26.62%,and 18.29%,respectively.In addition,the system shows multi-climate adaptability and broad application scenarios,making it a potential solution to building energy saving.
文摘“双碳”目标背景下,为解决热电联产机组“以热定电”模式导致的大规模弃风问题,本文提出基于先进绝热压缩空气储能电站(advanced adiabatic compressed air energy storage,AA-CAES)和综合需求响应的综合能源系统(integrated energy system,IES)供暖期弃风消纳策略。首先,在“源-储”两侧建立热电联产机组与AA-CAES电站耦合运行模型,分析耦合运行实现热电解耦机理;其次,在“荷”侧引入价格型和替代型需求响应机制来探寻负荷侧优化系统调度潜力;然后,在IES中引入碳捕集系统和阶梯型碳交易机制来约束碳排放,并在碳排放量最少、综合成本最低为目标构建IES运行基础上,引入模糊机会规划约束模型来分析风、光不确定性对系统调度影响;最后,利用西北某地区实际数据进行算例验证。结果表明:热电机组与AA-CAES电站耦合运行相较于未耦合运行可提高风电消纳率84.55%、降低总成本11.42%、减少碳排放20.28%;综合需求响应机制的引入可进一步提高风电消纳率35.00%、降低总成本20.93%、减少碳排放24.43%;风光不确定性的上升会提高与外部电网的交互成本。
文摘辐射供冷空调系统是一种舒适、节能的新型空调系统。为了对比地面、顶板、墙面3种辐射供冷末端位置的室内热舒适和能耗情况,以济南市某办公建筑为例,利用仿真软件建立了辐射供冷加独立新风的复合空调系统,对比分析了3种辐射供冷方式的室内热舒适和房间能耗。结果表明:3种辐射供冷模型下,室内的相对湿度都在40%~60%舒适范围内;墙面和顶板辐射供冷的预测平均投票(Predicted Mean Vote, PMV)值在0.25~0.50之间,而预测不满意百分数(Predicted Percentage of Dissatisfied, PPD)值小于10%,PMV-PPD指标达到了Ⅰ级,热舒适性较好;在设计日运行时间内,地面、顶板、墙面辐射供冷的总能耗分别为5.59、6.23、6.16 kW·h,地面辐射供冷的节能性最好。
文摘为加强先进绝热压缩空气储能(Advanced Adiabatic Compressed Air Energy Storage,AA-CAES)与综合能源系统(Integrated Energy Systems,IES)的多能互补协同,提高系统运行效率,文中提出了一种含AA-CAES能源站的电-热综合能源系统优化运行方法。构建了含AA-CAES能源站的IES基本调度架构,详细分析了AA-CAES装置在压缩和膨胀工况下的储热、换热及供热等特性,建立了AA-CAES电热联供联储运行模型;基于热网管道传热延迟和损耗等动态特性,建立了考虑供热网储热惯性的热网方程;在此基础上,考虑了用户侧可调度资源,提出了计及综合需求响应的含AA-CAES能源站的IES日前优化运行模型;在修改的IEEE 33节点配电网和巴厘岛32节点区域供热网进行算例分析。仿真结果表明,所提方法可有效降低IES运行成本,提高IES可再生能源消纳能力。