Air content, spacing factor and specific surface of fresh concrete and hardened concrete with different air contents, slumps and mineral admixtures (fly ash, slag, fly ash + slag, fly ash + slag + silica fume composit...Air content, spacing factor and specific surface of fresh concrete and hardened concrete with different air contents, slumps and mineral admixtures (fly ash, slag, fly ash + slag, fly ash + slag + silica fume composite) were studied by the air-void analyzer (AVA) method and the microscopical method. The correlations between the test results obtained from different methods were analyzed. The results show that, there is a close correlation of air content and spacing factor between the fresh concrete and the hardened concrete, but the specific surface correlation is weak. The air content of concrete measured by the AVA method is smaller than that of the pressure method and the microscopical method, because AVA device captures only the air voids with the size smaller than 3 mm. Spacing factor of the fresh concrete measured by the AVA method is greater than that of the hardened concrete measured by the microscopical method, while the specific surface is smaller. When the criterion of 4%-7% air content measured by the pressure method and microscopical method is acceptable for concrete freezing-thawing (F-T) durability in cold weather, the air content measured by the AVA method should be 2.4%-4.6%. For the concrete F-T durability, when the criterion of the spacing factor measured by the microscopical method is 300 μm, the spacing factor measured by the AVA method should be 360 μm.展开更多
To explore the method to evaluate air-void parameters of fresh concrete rapidly, the spacing factor and specific surface of freshly mixed concrete of different air contents, different slumps and different mineral admi...To explore the method to evaluate air-void parameters of fresh concrete rapidly, the spacing factor and specific surface of freshly mixed concrete of different air contents, different slumps and different mineral admixtures (fly ash, fly ash-slag, fly ash-slag-silica fume composite) are studied by air-void analyzer (AVA), and the correlation between the air content measured by AVA and air content determinator is compared. The results show that the spacing factor of the fresh concrete decreases firstly and then increases with the increase of air content, however the specific surface has the opposite rule. When the air content is more than 8%, the spacing factor of fresh concrete increases and the specific surface decreases. For the fresh concrete samples with similar air content, the specific surface increases firstly and then decreases with the increase of slump, but the spacing factor decreases firstly and then increases. Mineral admixalre can reduce the spacing factor of fresh concrete and increase the specific surface to some degree. There is a good correlation between the air content measured by two methods, and the air content measured by AVA is about 70% of the air content measured by the air content determinator.展开更多
The process of air—sea fresh water exchange is included successfully in the Global— Ocean—Atmosphere Land—System model developed at the State Key Laboratory of Atmospheric Sciences and Geophysical Fluid Dynamics (...The process of air—sea fresh water exchange is included successfully in the Global— Ocean—Atmosphere Land—System model developed at the State Key Laboratory of Atmospheric Sciences and Geophysical Fluid Dynamics (LASG). The results of the coupled integration show that the climate drift has been controlled successfully. Analyses on the responses of ocean circulation to the changes of surface fresh water or salinity forcing show that the ocean spin-up stage under flux condition for salinity is the key to the implementation of air-sea fresh water flux coupling. This study also demonstrates that the Modified—Monthly—Flux—Anomaly coupling scheme (MMFA) brought forward by Yu and Zhang (1998) is suitable not only for daily air—sea heat flux coupling but also for daily fresh water flux coupling. Key words Fresh water flux - Air-sea coupling - Thermohaline circulation This work was co-supported by the National Key Project (Grant No.96-908-02-03), the Excellent National Key Laboratory Research Project (Grant No.49823002) and Chinese Academy of Sciences (CAS) under grant “ Bai Ren Ji Hua? for “Validation of Coupled Climate Models”.展开更多
In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer an...In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer and winter. The results show that while the volume of the treated fresh-air is 125 m3/h,in summer,at the outlet of the device,the air temperature is 21.5-24.0 ℃,the air humidity ratio is about 17 g/kg,the greatest temperature drop is about 9 ℃ ,and the largest dehydration quantity is about 6 g/kg. In winter,at the outlet of the device,the air temperature is 15-17 ℃,the air humidity ratio is about 11 g/kg,the largest temperature rise is about 11 ℃,and the largest humidification quantity is about 6 g/kg. Therefore,the application of this new fresh-air handing device can take full advantage of the natural energy,thus effectively reduce the traditional energy consumption for fresh-air handing.展开更多
The relevant standard requirements both in domestic and abroad provide the basis for designing air-conditioning system of railway vehicles present. However, there are great differences in the fresh air volume indicato...The relevant standard requirements both in domestic and abroad provide the basis for designing air-conditioning system of railway vehicles present. However, there are great differences in the fresh air volume indicators among different standards requirements, and the requirements of each vehicle procurement contracts are also different. The design of air-conditioning become difficult above these. In this paper, the fresh air volume of different type railway vehicles is analyzed from health and equipment electricity consumption according to the railway vehicles air-conditioning system standard requirements in domestic and abroad. Some advises for designing air-conditioning system of railway vehicles through the fresh air volume calculation and comparison for domestic air-conditioning system of railway vehicles was provided.展开更多
In this article, a new kind of solar fresh air system is designed in order to realize the improvement of thermal efficiency by the integrated application of the PCMs and heat pipe technology. Under the adequate sunshi...In this article, a new kind of solar fresh air system is designed in order to realize the improvement of thermal efficiency by the integrated application of the PCMs and heat pipe technology. Under the adequate sunshine condition, the fresh air is directly delivered into the indoor environment after being heated by the solar collector. When the sun radiation is reduced, the heated air temperature can not satisfy the need of supply of air temperature.The main heat source is changed to phase change heat storage equipment instead of solar energy. The system adopt heat pipe for a high-efficiency and isothermal heat transfer which recover the shortcomings of PCMs such as: low coefficient of thermal conductivity and poor thermal efficiency. This article establishes the physical model of phase change solar energy fresh air thermal storage system and creates the mathematical model of its unsteady heat transfer to simulate and analyse the operation process by using Fluent software. The results of the study show that, compared to normal fresh air system, the phase change solar energy fresh air thermal storage system has a significant improvement in energy saving and indoor comfort level and will play an important role in the energy sustainable development.展开更多
Heavy smog shrouded China's central and eastern regions for days this past January, and experts are advising citizens to stay inside. But how much safer is our indoor air? The U.S. Environmental Protection Agency'...Heavy smog shrouded China's central and eastern regions for days this past January, and experts are advising citizens to stay inside. But how much safer is our indoor air? The U.S. Environmental Protection Agency's research shows that 24 million people in the world die every year as a result of poor indoor air quality, said Song Guangsheng, Secretary General of China's Indoor Environment Test Center (CIETC).展开更多
基金Project(50908229) supported by the National Natural Science Foundation of ChinaProjects(2008G031-N, 50908229, 10125C131) supported by Technological Research and Development Programs of the Ministry of Railways, China
文摘Air content, spacing factor and specific surface of fresh concrete and hardened concrete with different air contents, slumps and mineral admixtures (fly ash, slag, fly ash + slag, fly ash + slag + silica fume composite) were studied by the air-void analyzer (AVA) method and the microscopical method. The correlations between the test results obtained from different methods were analyzed. The results show that, there is a close correlation of air content and spacing factor between the fresh concrete and the hardened concrete, but the specific surface correlation is weak. The air content of concrete measured by the AVA method is smaller than that of the pressure method and the microscopical method, because AVA device captures only the air voids with the size smaller than 3 mm. Spacing factor of the fresh concrete measured by the AVA method is greater than that of the hardened concrete measured by the microscopical method, while the specific surface is smaller. When the criterion of 4%-7% air content measured by the pressure method and microscopical method is acceptable for concrete freezing-thawing (F-T) durability in cold weather, the air content measured by the AVA method should be 2.4%-4.6%. For the concrete F-T durability, when the criterion of the spacing factor measured by the microscopical method is 300 μm, the spacing factor measured by the AVA method should be 360 μm.
基金Supported by National Natural Science Foundation of China(No.50908229)and the Technological Research and Development Programs of the Ministry of Railways(No.2008G031-N. 2010G004-E)
文摘To explore the method to evaluate air-void parameters of fresh concrete rapidly, the spacing factor and specific surface of freshly mixed concrete of different air contents, different slumps and different mineral admixtures (fly ash, fly ash-slag, fly ash-slag-silica fume composite) are studied by air-void analyzer (AVA), and the correlation between the air content measured by AVA and air content determinator is compared. The results show that the spacing factor of the fresh concrete decreases firstly and then increases with the increase of air content, however the specific surface has the opposite rule. When the air content is more than 8%, the spacing factor of fresh concrete increases and the specific surface decreases. For the fresh concrete samples with similar air content, the specific surface increases firstly and then decreases with the increase of slump, but the spacing factor decreases firstly and then increases. Mineral admixalre can reduce the spacing factor of fresh concrete and increase the specific surface to some degree. There is a good correlation between the air content measured by two methods, and the air content measured by AVA is about 70% of the air content measured by the air content determinator.
文摘The process of air—sea fresh water exchange is included successfully in the Global— Ocean—Atmosphere Land—System model developed at the State Key Laboratory of Atmospheric Sciences and Geophysical Fluid Dynamics (LASG). The results of the coupled integration show that the climate drift has been controlled successfully. Analyses on the responses of ocean circulation to the changes of surface fresh water or salinity forcing show that the ocean spin-up stage under flux condition for salinity is the key to the implementation of air-sea fresh water flux coupling. This study also demonstrates that the Modified—Monthly—Flux—Anomaly coupling scheme (MMFA) brought forward by Yu and Zhang (1998) is suitable not only for daily air—sea heat flux coupling but also for daily fresh water flux coupling. Key words Fresh water flux - Air-sea coupling - Thermohaline circulation This work was co-supported by the National Key Project (Grant No.96-908-02-03), the Excellent National Key Laboratory Research Project (Grant No.49823002) and Chinese Academy of Sciences (CAS) under grant “ Bai Ren Ji Hua? for “Validation of Coupled Climate Models”.
基金Project(2006BAJ01A02) supported by the Chinese of Science and Technology during the 11th Five-Year Plan Period
文摘In order to reduce the fresh-air handing energy consumption,a fresh-air handing device using earth energy was presented. The major part is a double pipe soil-air heat exchanger. Its performance was tested in summer and winter. The results show that while the volume of the treated fresh-air is 125 m3/h,in summer,at the outlet of the device,the air temperature is 21.5-24.0 ℃,the air humidity ratio is about 17 g/kg,the greatest temperature drop is about 9 ℃ ,and the largest dehydration quantity is about 6 g/kg. In winter,at the outlet of the device,the air temperature is 15-17 ℃,the air humidity ratio is about 11 g/kg,the largest temperature rise is about 11 ℃,and the largest humidification quantity is about 6 g/kg. Therefore,the application of this new fresh-air handing device can take full advantage of the natural energy,thus effectively reduce the traditional energy consumption for fresh-air handing.
文摘The relevant standard requirements both in domestic and abroad provide the basis for designing air-conditioning system of railway vehicles present. However, there are great differences in the fresh air volume indicators among different standards requirements, and the requirements of each vehicle procurement contracts are also different. The design of air-conditioning become difficult above these. In this paper, the fresh air volume of different type railway vehicles is analyzed from health and equipment electricity consumption according to the railway vehicles air-conditioning system standard requirements in domestic and abroad. Some advises for designing air-conditioning system of railway vehicles through the fresh air volume calculation and comparison for domestic air-conditioning system of railway vehicles was provided.
文摘In this article, a new kind of solar fresh air system is designed in order to realize the improvement of thermal efficiency by the integrated application of the PCMs and heat pipe technology. Under the adequate sunshine condition, the fresh air is directly delivered into the indoor environment after being heated by the solar collector. When the sun radiation is reduced, the heated air temperature can not satisfy the need of supply of air temperature.The main heat source is changed to phase change heat storage equipment instead of solar energy. The system adopt heat pipe for a high-efficiency and isothermal heat transfer which recover the shortcomings of PCMs such as: low coefficient of thermal conductivity and poor thermal efficiency. This article establishes the physical model of phase change solar energy fresh air thermal storage system and creates the mathematical model of its unsteady heat transfer to simulate and analyse the operation process by using Fluent software. The results of the study show that, compared to normal fresh air system, the phase change solar energy fresh air thermal storage system has a significant improvement in energy saving and indoor comfort level and will play an important role in the energy sustainable development.
文摘Heavy smog shrouded China's central and eastern regions for days this past January, and experts are advising citizens to stay inside. But how much safer is our indoor air? The U.S. Environmental Protection Agency's research shows that 24 million people in the world die every year as a result of poor indoor air quality, said Song Guangsheng, Secretary General of China's Indoor Environment Test Center (CIETC).