Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS...Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms.展开更多
A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then...A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then the equation of motion for the system is analytically derived by applying the theorem of the relative kinetic energy for a system of particles in differential form in the non-inertial reference system described as a nonlinear differential equation. In the case of the small angular displacement, the natural frequency of the corresponding undamped linear system is obtained, which is consistent with the experimental observation. The derived equation is useful for the study of dynamic characteristics of novel FPS, and its solution directly expedites the simulation of the system in a control loop, and further facilitates the semi-active control process including novel FPS.展开更多
The seismic behavior of base isolated structures with friction pendulum slide bearings devices subjected to near fault events characterized by significant vertical ground motion components is investigated. In particul...The seismic behavior of base isolated structures with friction pendulum slide bearings devices subjected to near fault events characterized by significant vertical ground motion components is investigated. In particular, in order to evaluate the effects of vertical components on seismic response, non-linear dynamic analysis, carried out by using several numerical models, have been performed by considering two near-fault seismic events, L’Aquila 2009 and Emilia Romagna 2012. The obtained results show that increasing vertical seismic motion base shear significantly increases while relative displacements increase very little.展开更多
The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were sy...The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were systematically studied.First,the seismic responses of the base isolated structure with each control system under white noise excitation were obtained.Then,the structural parameter optimizations of the TVMD,TID and TMD were conducted by using three different objectives.The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses,including the base shear of the BIS,the absolute acceleration of structural SDOF,and the relative displacement between the base isolation floor and the foundation.Finally,considering the superstructure as a structural MDOF,a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations.The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases,and the effectiveness of TID was always better than TMD with the same mass ratio.The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD.Furthermore,the TVMD,when compared with TMD and TID,had better activation sensitivity and a smaller stroke.展开更多
The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in t...The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in this paper is effective in the resolution of difficulties in strong vertical capacity and vertical damping of three dimensional isolation bearings. It effectively suppresses rocking motions as well. The analytical model and motion equations of multi dimensional seismic responses of 3D base isolated frame structures are established. Taking a five storey frame structure as an example, an extensive simulation analysis is carried out. The results show that the 3D base isolated structure with the proposed 3DB is effective in 3D isolation; it can reduce seismic responses by 50 % compared to a non isolated structure. Therefore, the 3D isolation problem in building can be solved easily and effectively with the 3DB proposed in this paper.展开更多
The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a nat...The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a natural period independent of the structure's seismic mass.This property makes FPS an ideal choice for isolating rack structures since merchandise may be placed on the racks in several possible arrangements.The results of a comprehensive parametric study aimed at evaluating the seismic performance of a four-shelf,two-bay selective pallet rack isolated with FPS is presented in this paper.The influence of radius of curvature of the FPS,seismic mass,and mass irregularity on the rack's seismic response is examined.The effect of variation of the coefficient of friction due to axial loading is studied by choosing friction values from two distinct friction characterization studies.The coefficient of friction calculated from these studies shows mild and significant variations,respectively,for the whole range of static axial loads expected on the isolator,and from different pallet mass arrangements considered.The optimum radius of curvature and the appropriate range of friction coefficient,for the defined range of static axial loads,to attain a desirable seismic performance are determined.展开更多
An inter-story shear model of asymmetric base-isolated structures incorporating deformation of each isolation bearing was built, and a method to simultaneously simulate bi-directional near-fault and far-field ground m...An inter-story shear model of asymmetric base-isolated structures incorporating deformation of each isolation bearing was built, and a method to simultaneously simulate bi-directional near-fault and far-field ground motions was proposed. A comparative study on the dynamic responses of asymmetric base-isolated structures under near-fault and far-field ground motions were conducted to investigate the effects of eccentricity in the isolation system and in the superstructures, the ratio of the uncoupled torsional to lateral frequency of the superstructure and the pulse period of near-fault ground motions on the nonlinear seismic response of asymmetric base-isolated structures. Numerical results show that eccentricity in the isolation system makes asymmetric base-isolated structure more sensitive to near-fault ground motions, and the pulse period of near-fault ground motions plays an import role in governing the seismic responses of asymmetric base-isolated structures.展开更多
The paper deals on a significant retrofit project currently under construction of an existing hospital building in Avellino (Italy). The seismic retrofit was realized by connecting together the first floors of the t...The paper deals on a significant retrofit project currently under construction of an existing hospital building in Avellino (Italy). The seismic retrofit was realized by connecting together the first floors of the three existing structures and by creating a unique isolation system composed of high damping rubber bearings and sliding devices. The base isolation is achieved by gradually cutting the building from foundation and installing the isolators at the level of upper edge of the columns. The study allows the verification of the adequacy of the isolation system, showing the benefits of the application of the isolation devices, the limitations and the characteristics of their performance.展开更多
Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set...Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set-back in the upper body of the large chassis structure.In the parts with stiffness mutation,the torsion effect caused by the tower is far greater than that of the chassis itself.In this study,a total of 273 ground motions are collected and then filtered into four types,including the near-field ordinary,near-field pulse,far-field ordinary,and far-field harmonic.An 8-degree(0.2 g)fortified large chassis base-isolated structure is established.Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions.The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower.When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010),it is recommended to adopt composite seismic isolation technology or add limit devices.Under the condition of long-period ground motions,the base-isolated structure reduces the lateral-torsional coupling effect of the large chassis structure,while the torsion response of large chassis’top layer increases.Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code.展开更多
A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bea...A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bearings is developed. Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS. The influence of frictional coefficients and radius of the FPS on seismic performance are discussed. Based on the study, some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.展开更多
The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as iso...The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modem isolation systems.展开更多
To investigate the effect of soil-pile-structure interaction(SPSI effect)on the dynamic response of a baseisolated structure with buried footings on a pile foundation,certain shake table tests are previously conducted...To investigate the effect of soil-pile-structure interaction(SPSI effect)on the dynamic response of a baseisolated structure with buried footings on a pile foundation,certain shake table tests are previously conducted.Based on the test results and the existing related studies,an efficient simplified model and a corresponding calculation method are verified for estimating the dynamic characteristics of a base-isolated structure with buried footings on a pile foundation with the SSI effect.In this method,the solutions by Veletsos and co-workers for a non-isolated structure with the SSI effect are verified and advanced for a base-isolated structure,and the solutions by Maravas and co-workers for a non-isolated structure on a pile foundation are introduced to consider the effect of the piles.By comparison with the shake table test,this work proves that the simplified method can efficiently estimate the dynamic responses of a base-isolated structure with buried footings on a pile foundation.Using parameter analysis,this work also shows that the dynamic characteristics of a non-isolated structure are quite similar to those of the base-isolated structure when the soil foundation is sufficiently soft,which means that the isolation layer gradually loses its isolation function as the soil foundation softens.展开更多
The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 eart...The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.展开更多
文摘Current structural analysis software programs offer few if any applicable device-specifi c hysteresis rules or nonlinear elements to simulate the precise mechanical behavior of a multiple friction pendulum system(MFPS) with numerous sliding interfaces.Based on the concept of subsystems,an equivalent series system that adopts existing nonlinear elements with parameters systematically calculated and mathematically proven through rigorous derivations is proposed.The aim is to simulate the characteristics of sliding motions for an MFPS isolation system with numerous concave sliding interfaces without prior knowledge of detailed information on the mobilized forces at various sliding stages.An MFPS with numerous concave sliding interfaces and one articulated or rigid slider located between these interfaces is divided into two subsystems: the fi rst represents the concave sliding interfaces above the slider,and the second represents those below the slider.The equivalent series system for the entire system is then obtained by connecting those for each subsystem in series.The equivalent series system is validated by comparing numerical results for an MFPS with four sliding interfaces obtained from the proposed method with those from a previous study by Fenz and Constantinou.Furthermore,these numerical results demonstrate that an MFPS isolator with numerous concave sliding interfaces,which may have any number of sliding interfaces,is a good isolation device to protect structures from earthquake damage through appropriate designs with controllable mechanisms.
文摘A novel friction pendulum system (FPS) with dual rollers is studied based on the multibody dynamics theory. By analyzing kinematic characteristics of the system, it is reduced to a one degree-of-freedom system. Then the equation of motion for the system is analytically derived by applying the theorem of the relative kinetic energy for a system of particles in differential form in the non-inertial reference system described as a nonlinear differential equation. In the case of the small angular displacement, the natural frequency of the corresponding undamped linear system is obtained, which is consistent with the experimental observation. The derived equation is useful for the study of dynamic characteristics of novel FPS, and its solution directly expedites the simulation of the system in a control loop, and further facilitates the semi-active control process including novel FPS.
文摘The seismic behavior of base isolated structures with friction pendulum slide bearings devices subjected to near fault events characterized by significant vertical ground motion components is investigated. In particular, in order to evaluate the effects of vertical components on seismic response, non-linear dynamic analysis, carried out by using several numerical models, have been performed by considering two near-fault seismic events, L’Aquila 2009 and Emilia Romagna 2012. The obtained results show that increasing vertical seismic motion base shear significantly increases while relative displacements increase very little.
基金National Key Research and Development Program of China under Grant No.2017YFC0703600 and No.2017YFC0703604。
文摘The optimal design and effectiveness of three control systems,tuned viscous mass damper(TVMD),tuned inerter damper(TID)and tuned mass damper(TMD),on mitigating the seismic responses of base isolated structures,were systematically studied.First,the seismic responses of the base isolated structure with each control system under white noise excitation were obtained.Then,the structural parameter optimizations of the TVMD,TID and TMD were conducted by using three different objectives.The results show that the three control systems were all effective in minimizing the root mean square value of seismic responses,including the base shear of the BIS,the absolute acceleration of structural SDOF,and the relative displacement between the base isolation floor and the foundation.Finally,considering the superstructure as a structural MDOF,a series of time history analyses were performed to investigate the effectiveness and activation sensitivity of the three control systems under far field and near fault seismic excitations.The results show that the effectiveness of TID and TMD with optimized parameters on mitigating the seismic responses of base isolated structures increased as the mass ratio increases,and the effectiveness of TID was always better than TMD with the same mass ratio.The TVMD with a lower mass ratio was more efficient in reducing the seismic response than the TID and TMD.Furthermore,the TVMD,when compared with TMD and TID,had better activation sensitivity and a smaller stroke.
文摘The three dimensional lead rubber dish spring bearing (3DB) is proposed in this paper. The 3DB is composed of lead rubber bearing (LRB) and dish spring bearing (DSB) with damper in series. The 3DB put forward in this paper is effective in the resolution of difficulties in strong vertical capacity and vertical damping of three dimensional isolation bearings. It effectively suppresses rocking motions as well. The analytical model and motion equations of multi dimensional seismic responses of 3D base isolated frame structures are established. Taking a five storey frame structure as an example, an extensive simulation analysis is carried out. The results show that the 3D base isolated structure with the proposed 3DB is effective in 3D isolation; it can reduce seismic responses by 50 % compared to a non isolated structure. Therefore, the 3D isolation problem in building can be solved easily and effectively with the 3DB proposed in this paper.
文摘The concept of base isolation for storage racks is still a developing subject and has not been addressed in the recently updated seismic codes for storage racks.The friction pendulum bearing system(FPS)generates a natural period independent of the structure's seismic mass.This property makes FPS an ideal choice for isolating rack structures since merchandise may be placed on the racks in several possible arrangements.The results of a comprehensive parametric study aimed at evaluating the seismic performance of a four-shelf,two-bay selective pallet rack isolated with FPS is presented in this paper.The influence of radius of curvature of the FPS,seismic mass,and mass irregularity on the rack's seismic response is examined.The effect of variation of the coefficient of friction due to axial loading is studied by choosing friction values from two distinct friction characterization studies.The coefficient of friction calculated from these studies shows mild and significant variations,respectively,for the whole range of static axial loads expected on the isolator,and from different pallet mass arrangements considered.The optimum radius of curvature and the appropriate range of friction coefficient,for the defined range of static axial loads,to attain a desirable seismic performance are determined.
基金The National Natural Science Foundation of China (No. 50778078)
文摘An inter-story shear model of asymmetric base-isolated structures incorporating deformation of each isolation bearing was built, and a method to simultaneously simulate bi-directional near-fault and far-field ground motions was proposed. A comparative study on the dynamic responses of asymmetric base-isolated structures under near-fault and far-field ground motions were conducted to investigate the effects of eccentricity in the isolation system and in the superstructures, the ratio of the uncoupled torsional to lateral frequency of the superstructure and the pulse period of near-fault ground motions on the nonlinear seismic response of asymmetric base-isolated structures. Numerical results show that eccentricity in the isolation system makes asymmetric base-isolated structure more sensitive to near-fault ground motions, and the pulse period of near-fault ground motions plays an import role in governing the seismic responses of asymmetric base-isolated structures.
文摘The paper deals on a significant retrofit project currently under construction of an existing hospital building in Avellino (Italy). The seismic retrofit was realized by connecting together the first floors of the three existing structures and by creating a unique isolation system composed of high damping rubber bearings and sliding devices. The base isolation is achieved by gradually cutting the building from foundation and installing the isolators at the level of upper edge of the columns. The study allows the verification of the adequacy of the isolation system, showing the benefits of the application of the isolation devices, the limitations and the characteristics of their performance.
基金This project is jointly sponsored by Yunnan Youth Earthquake Science Foundation(2020K06)the National Natural Science Foundation of China(51778149)Xiamen University Tan Kah College School-Enterprise Cooperation Foundation(JGH2020034).
文摘Long-period structures(e.g.Isolated structures)tend to produce pseudo-resonance with low frequency compo-nents of long-period ground motions,resulting in the increase in damage.Stiffness mutation occurs due to the set-back in the upper body of the large chassis structure.In the parts with stiffness mutation,the torsion effect caused by the tower is far greater than that of the chassis itself.In this study,a total of 273 ground motions are collected and then filtered into four types,including the near-field ordinary,near-field pulse,far-field ordinary,and far-field harmonic.An 8-degree(0.2 g)fortified large chassis base-isolated structure is established.Furthermore,ETABS program software is used to conduct nonlinear time history analysis on the isolation and seismic model under bi-directional earthquake ground motions.The comparison results show that the seismic isolation effect of the base-isolated structure under long-period ground motions is worse than that associated with ordinary ground motions when the seismic response reduction rate of the large base floor significantly decreases compared with that of the tower.When the inter-story displacement angle and the displacement of isolation layer of the chassis exceeds the limit of Code for Seismic Design of Buildings(GB 50011-2010),it is recommended to adopt composite seismic isolation technology or add limit devices.Under the condition of long-period ground motions,the base-isolated structure reduces the lateral-torsional coupling effect of the large chassis structure,while the torsion response of large chassis’top layer increases.Under long-period ground motions with the same acceleration peak,the response of the base-isolated structure increases much more than that of the seismic structure and the consideration of this impact is suggested to be added to the Code.
基金National Natural Science Foundation of China Under Grand No.50778006Funding Project for Academic Human Resources Development in Institutions of Higher Learning Under the Jurisdiction of Beijing Municipality
文摘A theoretical model of a friction pendulum system (FPS) is introduced to examine its application for the seismic isolation of spatial lattice shell structures. An equation of motion of the lattice shell with FPS bearings is developed. Then, seismic isolation studies are performed for both double-layer and single-layer lattice shell structures under different seismic input and design parameters of the FPS. The influence of frictional coefficients and radius of the FPS on seismic performance are discussed. Based on the study, some suggestions for seismic isolation design of lattice shells with FPS bearings are given and conclusions are made which could be helpful in the application of FPS.
基金support for this project was provided by the Multidisciplinary Center for Earthquake Engineering Research through a grant from the Earthquake Engineering Research Centers Program of the National Science Foundation under award number EEC 9701471.
文摘The complexity of modem seismically isolated structures requires the analysis of the structural, system and the isolation system in its entirety and the ability to capture potential discontinuous phenomena such as isolator uplift and their effects on the superstructures and the isolation hardware. In this paper, an analytical model is developed and a computational algorithm is formulated to analyze complex seismically isolated superstructures even when undergoing highly-nonlinear phenomena such as uplift. The computational model has the capability of modeling various types of isolation devices with strong nonlinearities, analyzing multiple superstructures (up to five separate superstructures) on multiple bases (up to five bases), and capturing the effects of lateral loads on bearing axial forces, including bearing uplift. The model developed herein has been utilized to form the software platform 3D-BASIS-ME-MB, which provides the practicing engineering community with a versatile tool for analysis and design of complex structures with modem isolation systems.
基金funded by the National Natural Science Foundation of China(No.51778282)the Science Research Foundations of Nanjing Institute of Technology(CKJA201505,JCYJ201618)
文摘To investigate the effect of soil-pile-structure interaction(SPSI effect)on the dynamic response of a baseisolated structure with buried footings on a pile foundation,certain shake table tests are previously conducted.Based on the test results and the existing related studies,an efficient simplified model and a corresponding calculation method are verified for estimating the dynamic characteristics of a base-isolated structure with buried footings on a pile foundation with the SSI effect.In this method,the solutions by Veletsos and co-workers for a non-isolated structure with the SSI effect are verified and advanced for a base-isolated structure,and the solutions by Maravas and co-workers for a non-isolated structure on a pile foundation are introduced to consider the effect of the piles.By comparison with the shake table test,this work proves that the simplified method can efficiently estimate the dynamic responses of a base-isolated structure with buried footings on a pile foundation.Using parameter analysis,this work also shows that the dynamic characteristics of a non-isolated structure are quite similar to those of the base-isolated structure when the soil foundation is sufficiently soft,which means that the isolation layer gradually loses its isolation function as the soil foundation softens.
基金jointly sponsored by the Institute of Engineering Mechanicsthe Natural Science Foundation of China(No.52122811)。
文摘The seismic performance of medical systems is crucial for the seismic resilience of communities.The report summarizes the observed damage to twelve hospital buildings in the area affected by the MW 7.8 and MW 7.5 earthquakes on February 6,2023 in Turkey.They include five base-isolated buildings and seven fixed-base buildings in southcentral Turkey's seven most heavily affected provinces.By relating the post-quake occupancy statuses of the hospitals with the estimated seismic demands during the earthquake doublet,the report offers the following observations:(1)the base-isolated hospital buildings on friction pendulum bearings generally exhibited superior performance of achieving the goal of immediate occupancy and provided better protection for nonstructural elements than fixed-base counterparts did;(2)the fixed-base hospital buildings of reinforced concrete structures constructed after 2001 successfully achieved the goal of collapse prevention even under very high seismic demands;(3)some fixed-base hospitals also remained operational even if they were very close to the fault rupture and were subjected to higher-than-design-level earthquake ground motions.