To address the control accuracy of large fuel flowrate during pressure fluctuation,a novel electro-hydraulic fuel metering unit(FMU)is constructed for afterburner fuel system of military aeroengine.Different from the ...To address the control accuracy of large fuel flowrate during pressure fluctuation,a novel electro-hydraulic fuel metering unit(FMU)is constructed for afterburner fuel system of military aeroengine.Different from the previous FMU,the proposed FMU can achieve the higher precision opening control by a new metering valve with double control chambers(MVDCC),and realize the lower pressure difference fluctuation regulating by a novel two-stage constant pressure difference compensated valve(CPDCV)with dynamic damping orifice and damping piston.The experimental and AMESim simulation results verify the validity and superiority of the novel FMU.Since the temperature-induced variation in fuel properties and device capabilities may degrade or even impair the properties of novel FMU,the discharge flowrate is analyzed by global sensitivity analysis to research the effect proportion of each factor,the temperature effect is explored to ensure the working reliability in long-span temperature variation.Finally,the optimization of structure parameters for novel CPDCV can further reduce pressure difference fluctuation during pressure regulation,and the overshoot,adjust time and the integral of time multiplied by absolute value of error(ITAE)can be reduced by 24%,30%and 26%,respectively.This paper provides a reference for improving the stability of large flowrate during pressure fluctuation.展开更多
Model-based fault diagnosis serves as an efficient and powerful technique in addressing fault detection and isolation(FDI)issues for control systems.However,the standard methods and their modifications still encounter...Model-based fault diagnosis serves as an efficient and powerful technique in addressing fault detection and isolation(FDI)issues for control systems.However,the standard methods and their modifications still encounter some difficulties in algorithm design and application for complex higher-order systems.To avoid these difficulties,a novel fault diagnosis framework based on multiple performance indicators of closed-loop control system is proposed.Under this framework,a socalled performance residual vector is constructed to measure the differences between the real system and the nominal model in terms of system stability,accuracy,and rapidity(SAR)respectively.The criteria for quantification,normalization of the SAR residuals and the explicit mappings between the thresholds and the required performance are given.FDI can be easily achieved simultaneously by monitoring the normalized residual vector length and direction in the SAR performance residual space.A case study on electro-hydraulic servo control system of turbofan engine is adopted to demonstrate the effectiveness of the proposed method.展开更多
基金co-supported by the National Key Basic Research Program of China(No.2014CB046403)the National Science and Technology Major Project(2017-V-0015-0067)。
文摘To address the control accuracy of large fuel flowrate during pressure fluctuation,a novel electro-hydraulic fuel metering unit(FMU)is constructed for afterburner fuel system of military aeroengine.Different from the previous FMU,the proposed FMU can achieve the higher precision opening control by a new metering valve with double control chambers(MVDCC),and realize the lower pressure difference fluctuation regulating by a novel two-stage constant pressure difference compensated valve(CPDCV)with dynamic damping orifice and damping piston.The experimental and AMESim simulation results verify the validity and superiority of the novel FMU.Since the temperature-induced variation in fuel properties and device capabilities may degrade or even impair the properties of novel FMU,the discharge flowrate is analyzed by global sensitivity analysis to research the effect proportion of each factor,the temperature effect is explored to ensure the working reliability in long-span temperature variation.Finally,the optimization of structure parameters for novel CPDCV can further reduce pressure difference fluctuation during pressure regulation,and the overshoot,adjust time and the integral of time multiplied by absolute value of error(ITAE)can be reduced by 24%,30%and 26%,respectively.This paper provides a reference for improving the stability of large flowrate during pressure fluctuation.
基金co-supported by the National Science and Technology Major Project of China(Nos.2017-V-0011-0062,2017-V-0010-0060)National Natural Science Foundation of China(51875014)the Academic Excellence Foundation of BUAA for PhD Students。
文摘Model-based fault diagnosis serves as an efficient and powerful technique in addressing fault detection and isolation(FDI)issues for control systems.However,the standard methods and their modifications still encounter some difficulties in algorithm design and application for complex higher-order systems.To avoid these difficulties,a novel fault diagnosis framework based on multiple performance indicators of closed-loop control system is proposed.Under this framework,a socalled performance residual vector is constructed to measure the differences between the real system and the nominal model in terms of system stability,accuracy,and rapidity(SAR)respectively.The criteria for quantification,normalization of the SAR residuals and the explicit mappings between the thresholds and the required performance are given.FDI can be easily achieved simultaneously by monitoring the normalized residual vector length and direction in the SAR performance residual space.A case study on electro-hydraulic servo control system of turbofan engine is adopted to demonstrate the effectiveness of the proposed method.