It is known from the New Energy and Industry Technology Development Organization (NEDO) roam map Japan, 2017 that the polymer electrolyte fuel cell (PEFC) power generation system is required to operate at 100°C f...It is known from the New Energy and Industry Technology Development Organization (NEDO) roam map Japan, 2017 that the polymer electrolyte fuel cell (PEFC) power generation system is required to operate at 100°C for application of mobility usage from 2020 to 2025. This study aims to clarify the effect of separator thickness on the distribution of the temperature of reaction surface (T<sub>react</sub>) at the initial temperature of cell (T<sub>ini</sub>) with flow rate, relative humidity (RH) of supply gases as well as RH of air surrounding cell of PEFC. The distribution of T<sub>react</sub> is estimated by means of the heat transfer model considering the H<sub>2</sub>O vapor transfer proposed by the authors. The relationship between the standard deviation of T<sub>react</sub>-T<sub>ini</sub> and total voltage obtained in the experiment is also investigated. We can know the effect of the flow rate of supply gas as well as RH of air surrounding cell of PEFC on the distribution of T<sub>react</sub>-T<sub>ini</sub> is not significant. It is observed the wider distribution of T<sub>react</sub>-T<sub>ini</sub> provides the reduction in power generation performance irrespective of separator thickness. In the case of separator thickness of 1.0 mm, the standard deviation of T<sub>react</sub>-T<sub>ini</sub> has smaller distribution range and the total voltage shows a larger variation compared to the other cases.展开更多
文摘It is known from the New Energy and Industry Technology Development Organization (NEDO) roam map Japan, 2017 that the polymer electrolyte fuel cell (PEFC) power generation system is required to operate at 100°C for application of mobility usage from 2020 to 2025. This study aims to clarify the effect of separator thickness on the distribution of the temperature of reaction surface (T<sub>react</sub>) at the initial temperature of cell (T<sub>ini</sub>) with flow rate, relative humidity (RH) of supply gases as well as RH of air surrounding cell of PEFC. The distribution of T<sub>react</sub> is estimated by means of the heat transfer model considering the H<sub>2</sub>O vapor transfer proposed by the authors. The relationship between the standard deviation of T<sub>react</sub>-T<sub>ini</sub> and total voltage obtained in the experiment is also investigated. We can know the effect of the flow rate of supply gas as well as RH of air surrounding cell of PEFC on the distribution of T<sub>react</sub>-T<sub>ini</sub> is not significant. It is observed the wider distribution of T<sub>react</sub>-T<sub>ini</sub> provides the reduction in power generation performance irrespective of separator thickness. In the case of separator thickness of 1.0 mm, the standard deviation of T<sub>react</sub>-T<sub>ini</sub> has smaller distribution range and the total voltage shows a larger variation compared to the other cases.