This paper is dedicated to analytical expression of the maximum electricity-cost ratio (M-ECR) point of the proton exchange membrane (PEM) fuel cell power generation as the function of cell constants and cost constant...This paper is dedicated to analytical expression of the maximum electricity-cost ratio (M-ECR) point of the proton exchange membrane (PEM) fuel cell power generation as the function of cell constants and cost constants. That is to formulize the maximum cost performance (MCP) magnitude and the optimal final operating (OFO) location in the working zone based on the five-constant ideal cell model and the two-constant cost model. The issues are well resolved by introducing the concepts of economic voltage and cost factor and describing the movement of the M-ECR point with cost factor. According to mathematical derivations, the movement can be described in the form of MCP and OFO curves. The derivations lead to a complete set of discriminants and criteria of the M-ECR point of PEM fuel cells that theoretically cover all of cell specialties and all of cost specialties. The discriminants and criteria may act as a general tool for the operation optimization of a diversity of PEM fuel cells and the economic viability estimation of the power generation.展开更多
The energy efficiency of proton exchange membrane (PEM) fuel cells always keeps changing with load and time. Considering cell diversity and operation variety, it’s of necessity to find a simple method to estimate the...The energy efficiency of proton exchange membrane (PEM) fuel cells always keeps changing with load and time. Considering cell diversity and operation variety, it’s of necessity to find a simple method to estimate the changes. The work is done with the recently developed ideal cell model on behalf of various real cells, and results in a complete set of efficiency formulae including one for the instantaneous and three for the average. The formulae stand for a volt-ampere method which permits the average efficiency to be estimated in the form of state function of cell output like the instantaneous efficiency. With cell constants for cell specialty representation in this method, the formulae can extend to cover various real cells and make it realized to broadly overview the instantaneous and average efficiency movements with both load and time throughout cell operating ranges. The energy efficiency formulization and overviews may help make clear the correlative parameters with the efficiency, help deepen acquaintance with efficiency change and assist in cell operation optimization.展开更多
文摘This paper is dedicated to analytical expression of the maximum electricity-cost ratio (M-ECR) point of the proton exchange membrane (PEM) fuel cell power generation as the function of cell constants and cost constants. That is to formulize the maximum cost performance (MCP) magnitude and the optimal final operating (OFO) location in the working zone based on the five-constant ideal cell model and the two-constant cost model. The issues are well resolved by introducing the concepts of economic voltage and cost factor and describing the movement of the M-ECR point with cost factor. According to mathematical derivations, the movement can be described in the form of MCP and OFO curves. The derivations lead to a complete set of discriminants and criteria of the M-ECR point of PEM fuel cells that theoretically cover all of cell specialties and all of cost specialties. The discriminants and criteria may act as a general tool for the operation optimization of a diversity of PEM fuel cells and the economic viability estimation of the power generation.
文摘The energy efficiency of proton exchange membrane (PEM) fuel cells always keeps changing with load and time. Considering cell diversity and operation variety, it’s of necessity to find a simple method to estimate the changes. The work is done with the recently developed ideal cell model on behalf of various real cells, and results in a complete set of efficiency formulae including one for the instantaneous and three for the average. The formulae stand for a volt-ampere method which permits the average efficiency to be estimated in the form of state function of cell output like the instantaneous efficiency. With cell constants for cell specialty representation in this method, the formulae can extend to cover various real cells and make it realized to broadly overview the instantaneous and average efficiency movements with both load and time throughout cell operating ranges. The energy efficiency formulization and overviews may help make clear the correlative parameters with the efficiency, help deepen acquaintance with efficiency change and assist in cell operation optimization.