期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
DC Traction Power Supply System Based on Modular Multilevel Converter Suitable for Energy Feeding and De-icing 被引量:1
1
作者 Lingxi Hou Shuqing Zhang +4 位作者 Yingdong Wei Xiaoqian Li Qirong Jiang Mingrui Li Weirui Li 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第2期649-659,共11页
A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel convert... A novel DC traction power supply system suitable for energy feeding and de-icing is proposed in this paper for an urban rail transit catenary on the basis of the full bridge submodule (FBSM) modular multilevel converter (MMC). The FBSM-MMC is a novel type of voltage source converter (VSC) and can directly control the output DC voltage and conduct bipolar currents, thus flexibly controlling the power flow of the urban rail transit catenary. The proposed topology can overcome the inherent disadvantages of the output voltage drop in the diode rectifier units, increase the power supply distance and reduce the number of traction substations. The flexible DC technology can coordinate multiple FBSM-MMCs in a wide area and jointly complete the bidirectional control of catenary power flow during the operation of the electric locomotive, so as to realize the local consumption and optimal utilization of the recovered braking energy of the train. In addition, the FBSM-MMCs can also adjust the output current when the locomotive is out of service to prevent the catenary from icing in winter. The working modes of the proposed topology are illustrated in detail and the control strategy is specially designed for normal locomotive operations and catenary de-icing. Simulation cases conducted by PSCAD/EMTDC validate the proposed topology and its control strategy. 展开更多
关键词 DC traction power supply system de-icing for catenary energy feeding modular multilevel converter based on full-bridge submodules(FBSM-MMC) urban rail transit
原文传递
DC faults ride-through capability analysis of Full-Bridge MMC-MTDC System 被引量:38
2
作者 ZHAO ChengYong XU JianZhong LI Tan 《Science China(Technological Sciences)》 SCIE EI CAS 2013年第1期253-261,共9页
Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locat... Full-Bridge Modular Multilevel Converter(FBMMC) has strong ability to ride through serious DC faults,thus it is very suitable for multi-terminal flexible HVDC applications.However,no references have reported the locating and isolating of DC faults and corresponding DC faults ride-through capability evaluation index.This paper introduces the topology mechanism of FBMMC and its loss reduction operation mode,theoretically certifies that the universal decoupled control strategy of Voltage Source Converter(VSC) and the similar modulation strategies of Half-Bridge MMC(HBMMC) can be applied to FBMMC for constructing complete closed-loop control system.On the basis of the existing DC faults locating and isolating schemes of 2-level VSC based Multi-Terminal HVDC(VSC-MTDC) system and the particularity of FBMMC,this paper proposes the DC faults wire selection "handshaking" method of the FBMMC-MTDC system,and proposes the DC Fault Ride-Through Capability Index(DFRTI) for evaluating the DC faults suppressing capability of the VSC-MTDC systems,including FBMMC-MTDC.Simulations of FBMMC-MTDC in PSCAD/EMTDC validate the correctness and effectiveness of the proposed control strategy and evaluation index. 展开更多
关键词 full-bridge modular multilevel converter multi-terminal flexible HVDC handshaking method DC fault ride-through capability index(DFRTI)
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部