This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monit...This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monitor the variations in temperature and pressure of the vehicle’s tire, and the TPMS system is involved. It improves the driver’s safety by automatically detecting the tire pressure and temperature and then warning signal is sent to driver to take a measure, which prevents from accident. The proposed system of tire pressure monitoring system using SoC increases the speed of indication time to the driver by using mixed signals. The inflation of the tire can be avoided by preventing from high temperature and high pressure. Limitation of temperature and pressure in the previous system is also elongated i.e. temperature from 40℃ to 125℃ and pressure from 0 to 750 Kpa. Sensors, wireless communication (Bluetooth dongle) and SoC unit are used to design the low power TPMS. Quantitative results are taken and the analogy between temperature and pressure is also verified. The tested results proved by need of the practical system. Signal conditioning voltage and SoC unit is the trace for low power design TPMS. Finally, the performance of the system is tested and executed by using proteus software given as a real time application.展开更多
Because the melting point of the alkalis is very high and the metal activity is strong, the common pressure sensor can't be used to measure pressure of liquid metal. In this paper, a differential transformer differen...Because the melting point of the alkalis is very high and the metal activity is strong, the common pressure sensor can't be used to measure pressure of liquid metal. In this paper, a differential transformer differential pressure sensor for measuring liquid alkalis pressure is designed, the working principle and specific design plan of the sensor are introduced, the standard current signal ( 4 -20 mA) or digital communication RS485 can be output according to the needs, and the functions of remote monitoring and data optimization can be realized through the LAN interface.展开更多
AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract.METHODS: The authors developed a miniature, multifunctional gastrointestinal monitoring syste...AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract.METHODS: The authors developed a miniature, multifunctional gastrointestinal monitoring system, which comprises a set of indigestible biotelemetry capsules and a data recorder.The capsule, after ingested by patients, could measure pressure, temperature and pH value in the gastrointestinal tract and transmit the data to the data recorder outside the body through a 434 MHz radio frequency data link. After the capsule passed out from the body, the data saved in the recorder were downloaded to a workstation via a special software for further analysis and comparison.RESULTS: Clinical experiments showed that the biotelemetry capsules could be swallowed by volunteers without any difficulties. The data recorder could receive the radio frequency signals transmitted by the biotelemetry in the body. The biotelemetry capsule could pass out from the body without difficulties. No discomfort was reported by any volunteer during the experiment. In vivo pressure and temperature data were acquired.CONCLUSION: A non-invasive method for monitoring 24-h gastrointestinal parameters was proposed and tested by the authors. The feasibility and functionality of this method are verified by laboratory tests and clinical experiments.展开更多
Co-cracking is a process where the mixtures of different hydrocarbon feedstocks are cracked in a steam pyrolysis furnace, and widely adopted in chemical industries. In this work, the simulations of the co-cracking of ...Co-cracking is a process where the mixtures of different hydrocarbon feedstocks are cracked in a steam pyrolysis furnace, and widely adopted in chemical industries. In this work, the simulations of the co-cracking of ethane and propane, and LPG and naphtha mixtures have been conducted, and the software packages of COILSIM1 D and Sim CO are used to account for the cracking process in a tube reactor. The effects of the mixing ratio, coil outlet temperature, and pressure on cracking performance have been discussed in detail. The co-cracking of ethane and propane mixture leads to a lower profitability than the cracking of single ethane or single propane. For naphtha, cracking with LPG leads to a higher profitability than single cracking of naphtha, and more LPG can produce a higher profitability.展开更多
文摘This paper presents the tire pressure monitoring system (TPMS) by using the system on chip (SoC) mixed signals with the help of Bluetooth transmission and in advantage of low power consumption design. This is to monitor the variations in temperature and pressure of the vehicle’s tire, and the TPMS system is involved. It improves the driver’s safety by automatically detecting the tire pressure and temperature and then warning signal is sent to driver to take a measure, which prevents from accident. The proposed system of tire pressure monitoring system using SoC increases the speed of indication time to the driver by using mixed signals. The inflation of the tire can be avoided by preventing from high temperature and high pressure. Limitation of temperature and pressure in the previous system is also elongated i.e. temperature from 40℃ to 125℃ and pressure from 0 to 750 Kpa. Sensors, wireless communication (Bluetooth dongle) and SoC unit are used to design the low power TPMS. Quantitative results are taken and the analogy between temperature and pressure is also verified. The tested results proved by need of the practical system. Signal conditioning voltage and SoC unit is the trace for low power design TPMS. Finally, the performance of the system is tested and executed by using proteus software given as a real time application.
文摘Because the melting point of the alkalis is very high and the metal activity is strong, the common pressure sensor can't be used to measure pressure of liquid metal. In this paper, a differential transformer differential pressure sensor for measuring liquid alkalis pressure is designed, the working principle and specific design plan of the sensor are introduced, the standard current signal ( 4 -20 mA) or digital communication RS485 can be output according to the needs, and the functions of remote monitoring and data optimization can be realized through the LAN interface.
基金Supported by the National Natural Science Foundation of China, No. 30270382High Technology Research and Development Program of China, No. 2002AA404280
文摘AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract.METHODS: The authors developed a miniature, multifunctional gastrointestinal monitoring system, which comprises a set of indigestible biotelemetry capsules and a data recorder.The capsule, after ingested by patients, could measure pressure, temperature and pH value in the gastrointestinal tract and transmit the data to the data recorder outside the body through a 434 MHz radio frequency data link. After the capsule passed out from the body, the data saved in the recorder were downloaded to a workstation via a special software for further analysis and comparison.RESULTS: Clinical experiments showed that the biotelemetry capsules could be swallowed by volunteers without any difficulties. The data recorder could receive the radio frequency signals transmitted by the biotelemetry in the body. The biotelemetry capsule could pass out from the body without difficulties. No discomfort was reported by any volunteer during the experiment. In vivo pressure and temperature data were acquired.CONCLUSION: A non-invasive method for monitoring 24-h gastrointestinal parameters was proposed and tested by the authors. The feasibility and functionality of this method are verified by laboratory tests and clinical experiments.
基金Supported by the National Natural Science Foundation of China(21276078)Shanghai Key Technologies R&D Programe(12dz1125100)+1 种基金Natural Science Foundation of Shanghai(13ZR1411300)Shanghai Leading Academic Discipline Project(B504)
文摘Co-cracking is a process where the mixtures of different hydrocarbon feedstocks are cracked in a steam pyrolysis furnace, and widely adopted in chemical industries. In this work, the simulations of the co-cracking of ethane and propane, and LPG and naphtha mixtures have been conducted, and the software packages of COILSIM1 D and Sim CO are used to account for the cracking process in a tube reactor. The effects of the mixing ratio, coil outlet temperature, and pressure on cracking performance have been discussed in detail. The co-cracking of ethane and propane mixture leads to a lower profitability than the cracking of single ethane or single propane. For naphtha, cracking with LPG leads to a higher profitability than single cracking of naphtha, and more LPG can produce a higher profitability.