In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy ...In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy spectrum detectors based on gadolinium gallium aluminum garnet (Ce:GAGG) scintillation crystals are minor. In this work, a 1-inch Ce:GAGG and Silicon Photomultipliers (SiPMs) are employed to construct a detector, and the coupled medium was silicone oil. An optimal SiPMs quantity scheme for the energy resolution was determined by varying the number of SiPMs coupled to Ce:GAGG and studying the effect of the different number of SiPMs on the energy resolution of the detector. Energy-resolution contrast experiments between Ce:GAGG and NaI(Tl) were performed using this scheme. The experimental results demonstrate that increasing the number of SiPMs enhances the energy resolution of the detector significantly. Notably, the energy resolution of the Ce:GAGG detector is comparable to that of the NaI(Tl) detector. Additionally, both detectors exhibit an energy linearity exceeding 99.9%. .展开更多
A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cr...A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.展开更多
Measurements of the potassium content of samples of food, performed with High Purity Germanium detectors, are presented in this paper. The potassium content was measured by identifying the 1460 keV photons produced in...Measurements of the potassium content of samples of food, performed with High Purity Germanium detectors, are presented in this paper. The potassium content was measured by identifying the 1460 keV photons produced in the decay of the isotope 40K. Samples were selected, for which a high potassium content was expected. The measurements confirmed the expectations qualitatively, but not always quantitatively. Especially the expected dependence of the potassium content of chocolate on the listed percentage of cacao could not be confirmed.展开更多
文摘In the field of nuclear radiation detection, sodium iodide (NaI(Tl)) and lanthanum bromide (LaBr<sub>3</sub>) are the primary scintillation crystals used for energy spectrum detectors. Furthermore, energy spectrum detectors based on gadolinium gallium aluminum garnet (Ce:GAGG) scintillation crystals are minor. In this work, a 1-inch Ce:GAGG and Silicon Photomultipliers (SiPMs) are employed to construct a detector, and the coupled medium was silicone oil. An optimal SiPMs quantity scheme for the energy resolution was determined by varying the number of SiPMs coupled to Ce:GAGG and studying the effect of the different number of SiPMs on the energy resolution of the detector. Energy-resolution contrast experiments between Ce:GAGG and NaI(Tl) were performed using this scheme. The experimental results demonstrate that increasing the number of SiPMs enhances the energy resolution of the detector significantly. Notably, the energy resolution of the Ce:GAGG detector is comparable to that of the NaI(Tl) detector. Additionally, both detectors exhibit an energy linearity exceeding 99.9%. .
基金supported by the National Key R&D Program of China(No.2018YFA0404403)the National Natural Science Foundation of China(Nos.12035001,12075006,11675003)the State Key Laboratory of Nuclear Physics and Technology,PKU(No.NPT2020KFY18)。
文摘A newly developed digital data acquisition system,which is based on the digital pulse processor Pixie-16 modules by XIA LLC,was tested with the c-ray detector array of the China Institute of Atomic Energy using the cray source and in-beam c-rays.A comparison between this digital data acquisition system and the conventional analog data acquisition system was made.At a low count rate,both systems exhibit good and comparable energy resolutions.At a high count rate above 8.8 k/s,while the energy resolution obtained by the analog system deteriorates significantly,the energy resolution obtained by the digital system is nearly unchanged.Meanwhile,experimental data with higher statistics can be collected by the digital system.The advantage of this digital system over the conventional analog system can be ascribed to its excellent capability of handling pile-up pulses at higher count rates,and the fact that it has nearly no dead time in data transmission and conversion.
文摘Measurements of the potassium content of samples of food, performed with High Purity Germanium detectors, are presented in this paper. The potassium content was measured by identifying the 1460 keV photons produced in the decay of the isotope 40K. Samples were selected, for which a high potassium content was expected. The measurements confirmed the expectations qualitatively, but not always quantitatively. Especially the expected dependence of the potassium content of chocolate on the listed percentage of cacao could not be confirmed.