This paper simulates the combustion system of a regular tankless gas water heater under different static pressure conditions.The simulation results are in accordance with the test results.It proves that the used physi...This paper simulates the combustion system of a regular tankless gas water heater under different static pressure conditions.The simulation results are in accordance with the test results.It proves that the used physical and mathematical models are reasonable.The results show that the flame height and the excess air ratios depend on the system pressure drop but not on the absolute pressure at the combustion chamber.The pressure drop and the amount of combustion air have an inverse relationship with CO generation,and they also impact on the temperature and velocity fields.To reduce CO emission,a stronger fan is needed to provide extra pressure head to ensure that enough combustion air is introduced into the system.This study provides a useful research tool to develop products through computational fluid dynamic analysis and laboratory testing.展开更多
One of the effective options for energy saving in terms of heat costs for the formation of routine thermal conditions of working areas of large-sized industrial premises is the replacement of traditional convective(wa...One of the effective options for energy saving in terms of heat costs for the formation of routine thermal conditions of working areas of large-sized industrial premises is the replacement of traditional convective(water)heating systems with systems,the main part of which are gas infrared emitters.But the mass introduction of such systems based on emitters was held back until recently by the lack of scientific and technical foundations for ensuring not only the routine thermal conditions of local working areas,but also ensuring acceptable concentrations of carbon dioxide,which is formed during the operation of a gas emitter.Solving the latter problem by the method of experimental selection of heating and air exchange modes is practically impossible due to the multivariate nature of possible solutions to this problem.Therefore,the purpose of the work is to analyze the results of theoretical studies of the possibility of ensuring an acceptable level of carbon dioxide concentrations in local working areas during the operation of gas infrared emitters and an air exchange system.Numerical modeling of heat and mass transfer processes under such conditions was performed in a fairly wide range of the main significant factors:air flow rate in the air exchange system from 0.01 to 0.04 kg/s,the position of the air inlet and outlet channels relative to the radiator and the local workplace(height from 0.3 to 4.1 m).It was found that by varying the numerical values of these factors,it is possible to ensure carbon dioxide concentrations in the local working area within the permissible limits of up to 1400 ppm.展开更多
文摘This paper simulates the combustion system of a regular tankless gas water heater under different static pressure conditions.The simulation results are in accordance with the test results.It proves that the used physical and mathematical models are reasonable.The results show that the flame height and the excess air ratios depend on the system pressure drop but not on the absolute pressure at the combustion chamber.The pressure drop and the amount of combustion air have an inverse relationship with CO generation,and they also impact on the temperature and velocity fields.To reduce CO emission,a stronger fan is needed to provide extra pressure head to ensure that enough combustion air is introduced into the system.This study provides a useful research tool to develop products through computational fluid dynamic analysis and laboratory testing.
基金supported by the Russian Science Foundation(grant number 20-19-00226).
文摘One of the effective options for energy saving in terms of heat costs for the formation of routine thermal conditions of working areas of large-sized industrial premises is the replacement of traditional convective(water)heating systems with systems,the main part of which are gas infrared emitters.But the mass introduction of such systems based on emitters was held back until recently by the lack of scientific and technical foundations for ensuring not only the routine thermal conditions of local working areas,but also ensuring acceptable concentrations of carbon dioxide,which is formed during the operation of a gas emitter.Solving the latter problem by the method of experimental selection of heating and air exchange modes is practically impossible due to the multivariate nature of possible solutions to this problem.Therefore,the purpose of the work is to analyze the results of theoretical studies of the possibility of ensuring an acceptable level of carbon dioxide concentrations in local working areas during the operation of gas infrared emitters and an air exchange system.Numerical modeling of heat and mass transfer processes under such conditions was performed in a fairly wide range of the main significant factors:air flow rate in the air exchange system from 0.01 to 0.04 kg/s,the position of the air inlet and outlet channels relative to the radiator and the local workplace(height from 0.3 to 4.1 m).It was found that by varying the numerical values of these factors,it is possible to ensure carbon dioxide concentrations in the local working area within the permissible limits of up to 1400 ppm.