[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by ga...[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.展开更多
[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by aceto...[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by acetonitrile, and anhydrous magnesium sulfate was used for salting out. The extracts were then purified by dispersive solid phase extraction combining with GCB, C18 and PSA. Samples were analyzed by FPD detector. External standard was used as quantitive method. [ Results] The detection limits were in the range of 0. 001 -0. 008 mg/kg, the average recoveries ranged from 83.5% to 101.2% , and the relative standard deviation (RSD) of the eight organophosphorus pesticide residues were below 5%. [ Conclusions] The method is simple, quick, easy and effective for the determination of pepper.展开更多
This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Vali...This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.展开更多
基金Supported by The Fourth Batch of High-end Talent Project in Hebei Province.
文摘[Objectives]This study was conducted to purify mutton samples by gel permeation chromatography(GPC).[Methods]Fourteen organophosphorus pesticide residues in samples were qualitatively and quantitatively analyzed by gas chromatography-mass spectrometry(GC-MS)in selective ion scanning mode(SIM).[Results]The organophosphorus pesticide standard solutions showed good linearity in the mass concentration range of 0.1-10.0μg/ml with correlation coefficients(r)not lower than 0.999,and the detection limits(S=3 N)ranged from 0.01 to 0.05 mg/kg.The average recovery values were in the range of 80.2%-99.7%,with relative standard deviations(RSDs,n=3)in the range of 1.8%-6.3%,at the addition levels of 0.5,1.0 and 2.0 mg/kg.[Conclusions]The method is simple,sensitive and accurate,and can be used for the determination of organophosphorus pesticide residues in mutton.
基金Supported by Post-doctoral Scientific Fund of China(No.2017M611382)Autonomy Program of Economy,Trade and Information Commission of Shenzhen Municipality(No.20170427160059840)
文摘[ Objectives] This study was conducted to establish a QuEChERS-gas chromatography method for determination of eight kinds of organophosphorus pesticide residues in pepper. [Methods] The samples were extracted by acetonitrile, and anhydrous magnesium sulfate was used for salting out. The extracts were then purified by dispersive solid phase extraction combining with GCB, C18 and PSA. Samples were analyzed by FPD detector. External standard was used as quantitive method. [ Results] The detection limits were in the range of 0. 001 -0. 008 mg/kg, the average recoveries ranged from 83.5% to 101.2% , and the relative standard deviation (RSD) of the eight organophosphorus pesticide residues were below 5%. [ Conclusions] The method is simple, quick, easy and effective for the determination of pepper.
文摘This research paper describes simple analytical method for determination of Camylofin dihydrochloride and Nimesulide in tablet formulation by Gas chromatography method. Benzoic acid was used as internal standard. Validation was carried out in compliance with the International Conference on Harmonization guidelines. The method utilized GC (Agilent Technologies 6890 N Network GC system with FID detector), and RTX-5 capillary column (5% diphenyl-95% dimethyl polysiloxane), 30 m × 0.53 mm, 1.5 μm as stationary phase. Helium was used as the carrier gas at a flow rate of 1.5 mL?min–1. The proposed method was validated for linearity, LOD, LOQ, accuracy, precision, ruggedness and solution stability. It can be conveniently adopted for routine quality control analysis.