固相微萃取/气相色谱/燃烧-同位素比值质谱技术测定水体中微量苯系物单体碳同位素方法研究
1
作者 漆艳 尹希杰 +1 位作者 李玉红 林锡煌 《分析测试学报》 CAS CSCD 北大核心 2024年第9期1474-1480,共7页
该文建立了固相微萃取/气相色谱/燃烧-同位素比值质谱(SPME/GC/C-IRMS)技术测定水体中7种苯系物碳同位素(δ13C)的方法。实验结果表明,萃取温度30℃,萃取时间60 min条件下萃取效果最佳,萃取温度(30~60℃)和萃取时间(15~60 min)对顶空萃... 该文建立了固相微萃取/气相色谱/燃烧-同位素比值质谱(SPME/GC/C-IRMS)技术测定水体中7种苯系物碳同位素(δ13C)的方法。实验结果表明,萃取温度30℃,萃取时间60 min条件下萃取效果最佳,萃取温度(30~60℃)和萃取时间(15~60 min)对顶空萃取(HS-SPME)过程中的碳同位素分馏无影响。最佳萃取条件下,利用HS-SPME和直接萃取(D-SPME)方法分别测试7种苯系物的δ13C值,标准偏差分别为0.08‰~0.45‰和0.05‰~0.39‰,测试误差分别为-0.16‰~0.33‰和-0.41‰~0.46‰,两种SPME方式在萃取过程中均未发生明显碳同位素分馏,HS-SPME的灵敏度比D-SPME方法高1~2个数量级。通过移动平均值算法计算苯、间/对二甲苯、异丙苯的检出限为1μg/L,甲苯、乙苯、邻二甲苯、苯乙烯的检出限为2μg/L。测得江苏某废弃农药场地下水中7种苯系物δ13C值的标准偏差为0.01‰~0.43‰。该方法样品前处理简单、灵敏度高、准确性好,适用于水体中痕量苯系物单体碳同位素的检测。 展开更多
关键词 苯系物 固相微萃取 气相色谱/燃烧-同位素质谱 单体碳稳定同位素分析 水体
下载PDF
Developing an authentication approach using SPME-GC-IRMS based on compound-specific δ^(13)C analysis of six typical volatiles in wine
2
作者 Xinyu Jin Limin Zhang +3 位作者 Shimin Wu Mingquan Huang Wenjuan Yu Shanshan Zhang 《Food Quality and Safety》 SCIE CSCD 2021年第1期56-66,共11页
An analytical method using gas chromatography isotope ratio mass spectrometry(GC-IRMS)combined with solid phase micro-extraction(SPME)was developed to measure the 613C values of six typical volatiles commonly occurrin... An analytical method using gas chromatography isotope ratio mass spectrometry(GC-IRMS)combined with solid phase micro-extraction(SPME)was developed to measure the 613C values of six typical volatiles commonly occurring in wine(isoamyl acetate,2-octanone,limonene,2-phenylethanol,ethyl octanoate and ethyl decanoate)for the first time.SPME selected with a divinylbenzene/carboxen/polydimethylsiloxane fiber was combined with the GC-IRMS for pretreatment optimization.The optimized SPME parameters of extraction time,extraction temperature and salt concentration were 40 min,40℃ and 10%,respectively.The 613C values measured by SPME-GC-IRMS were in good agreement with those measured via elemental analyzer(EA)-IRMS and GC-IRMS.The differences range from 0.02‰to 0.44‰ with EA-IRMS and from 0 to 0.28‰ with GC-IRMS,indicating the high accuracy of the method.This newly established method measured the precision within 0.30‰ and was successfully validated to discriminate imported real wine samples with identical label but amazing price differences from different importers. 展开更多
关键词 AUTHENTICITY δ^(13)C wine volatile compound-specific isotope analysis gas chromatography isotope ratio mass spectrometry solid phase micro-extraction.
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部