THE STUDY ON MEASURING TECHNIQUE OF PARTIAL DISCHARGE IN GAS INSULATED SWITCHGEAR USING ULTRA HIGH FREQUENCY METHOD WITH EXTERNAL SENSORS 被引量:1
1
作者 李忠 冯允平 《Journal of Pharmaceutical Analysis》 SCIE CAS 2005年第2期7-10,15,共5页
Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this ... Objective In order to find early latent faults and prevent catastrophic failures, diagnosis of insulation condition by measuring technique of partial discharge(PD) in gas insulated switchgear (GIS) is applied in this paper, which is one of the most basic ways for diagnosis of insulation condition. Methods Ultra high frequency(UHF) PD detection method by using internal sensors has been proved efficient, because it may avoid the disturbance of corona, but the sensor installation of this method will be limited by the structure and operation condition of GIS. There are some of electromagnetic (E-M) waves leak from the place of insulation spacer, therefore, the external sensors UHF measuring PD technique is applied, which isn't limited by the operation condition of GIS. Results This paper analyzes propagated electromagnetic (E-M) waves of partial discharge pulse excited by using the finite-difference time-domain (FDTD) method. The signal collected at the outer point is more complex than that of the inner point, and the signals' amplitude of outer is about half of the inner, because it propagates through spacer and insulation slot. Set up UHF PD measuring system. The typical PD in 252kV GIS bus bar was measured using PD detection UHF technique with external sensors. Finally, compare the results of UHF measuring technique using external sensors with the results of FDTD method simulation and the traditional IEC60270 method detection. Conclusion The results of experiment shows that the UHF technique can realize the diagnosis of insulation condition, the results of FDTD method simulation and the result UHF method detection can demonstrate each other, which gives references to further researches and application for UHF PD measuring technique. 展开更多
关键词 gas insulated switchgear partial discharge ultra high frequency finite-difference time-domain (FDTD) method MEASUREMENT external sensor
下载PDF
Discharge Characteristics of Long SF6 Gas Gap with and Without Insulator in GIS Under VFTO and LI 被引量:17
2
作者 Tao Wen Qiaogen Zhang +6 位作者 Jingtan Ma Can Guo Haoyang You Yifan Qin Yu Yin Weidong Shi Weijiang Chen 《CSEE Journal of Power and Energy Systems》 SCIE 2015年第3期16-22,共7页
Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient over... Gas insulator switchgears(GISs),widely used in electric power systems for decades,have many advantages due to their compactness,minimal environmental impact,and long maintenance cycles.However,very fast transient overvoltage(VFTO)increases caused by a rise in voltage levels can lead to GIS insulation failures.In this paper,a generating system of VFTO and standard lightning impulse(LI)is established.The insulation characteristics of SF6 gas with and without insulators under VFTO and standard LI are investigated.Experimental results show that the 50%breakdown voltages of the inhomogeneous electric field rod-plane gap under positive VFTO and standard LI are higher than that under negative VFTO and standard LI.The research shows that the 50%breakdown voltage under VFTO could be lower than that under standard LI at 0.5 MPa for the negative polarity.Moreover,the polarity effect of the insulator without defect is different from that with defect.Similarly,the breakdown voltage of the defective insulator under VFTO could be lower than that under standard LI by 8%.The flashover channel under VFTO is seen as more than that under standard LI.Based on the analysis of discharge images and experimental results,it is concluded that the polarity effect is related to the distortion effect of ion clusters formed by SF6 on the electric field.Additionally,the steepness and front time of impulse plays an important role in the initiation and further development of discharge on insulator surface.Finally,the research shows that different discharge characteristics between VFTO and standard LI may be caused by different wave fronts and oscillation on the tails of the impulses. 展开更多
关键词 Breakdown voltage discharge characteristic gas insulated switchgear(GIS) lightning impulse(LI) space charge very fast transient overvoltage(VFTO)
原文传递
佛山地区500kV变电站设备运行缺陷分析 被引量:5
3
作者 郁景礼 高博 《广东电力》 2009年第2期68-72,共5页
对广东佛山地区500kV变电站运行设备从缺陷类别、发现方法、设备种类、出现原因、电压等级等方面进行了统计分析和总结,并提出了针对性较强的消缺和预防措施,对500kV变电站的运行管理、维护、建设有一定的指导意义。
关键词 500 KV变电站 封闭式组合电器(gasinsulated switchgear GIS) 缺陷 措施
下载PDF
单壁碳纳米管气体传感器在GIS局部放电检测中的应用(英文) 被引量:2
4
作者 魏宁 丁卫东 +2 位作者 朱宜东 苏春强 末广纯也 《高电压技术》 EI CAS CSCD 北大核心 2011年第11期2700-2706,共7页
This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by ... This paper describes a realizable fabrication method to manufacture chemical gas sensors by using singlewalled carbon nanotubes(SWCNTs).The sensors were tested for the monitoring of SF_6 decomposition gas produced by partial discharge(PD) in GIS tank.The results showed a superior sensitivity,favorable reliability and good reproducibility. For further clarifying the relativity between sensor response and partial discharge activity,the discharge in GIS tank was monitored simultaneously through conventional pulse current method and a SWCNTs gas sensor,and the measurement results were put together for comparative analysis in this paper.The sensor response showed a great dependence on partial discharge characteristics.The sensor response increased nearly linearly with limits when the energy of discharge was persistently accumulated.Partial discharge power had a great influence on the response rate and the time delay.With the increase of partial discharge power,the response rate augmented almost in proportion while the time delay gradually becomes shorter with limits.The results were quite favorable to assess the partial discharge intensity and duration to some extent.Compared with pulse current method,the sensor was predominant to detect partial discharge exposed to constantly high levels of noise.It was capable of detecting partial discharge which was too weak to be detected with pulse current method.However,the sensor response didn't show much dependency on the apparent discharge of partial discharge. 展开更多
关键词 single-walled carbon nanotubes(SWCNTs) gas sensors partial discharge(PD) detection gas insulated switchgear(GIS) tank SF6 decomposition gas PD parameters
下载PDF
浅谈六氟化硫气体介质的危害
5
作者 张瑞梅 《管理观察》 2008年第14期148-150,共3页
SF6气体因其优异的绝缘、灭弧性能及化学稳定性,已被广泛地应用在电力设备中,如高压断路器、变压器、互感器、电容器、避雷器、熔断器、管道母线等。随着SF6气体使用量的增加,范围的扩大,人们对其在使用过程中产生的危害有进一步的认识... SF6气体因其优异的绝缘、灭弧性能及化学稳定性,已被广泛地应用在电力设备中,如高压断路器、变压器、互感器、电容器、避雷器、熔断器、管道母线等。随着SF6气体使用量的增加,范围的扩大,人们对其在使用过程中产生的危害有进一步的认识。至2030年,六氟化硫气体将被禁止使用。 展开更多
关键词 六氟化硫气体Sulphur HEXAFLUORIDE gas 绝缘材料insulation materials 高压开关设备HV switchgears 环境污染envi ronment pollution
下载PDF
浅论六氟化硫组合开关安装的管理
6
作者 谢飞虎 《中国水能及电气化》 2007年第3期43-45,共3页
随着国民经济的发展需要,高压配电SF6的装置广泛应用于水电站、城区变电站。做好SF6的安装、维护,能保证电力系统的安全运行。
关键词 SF6气体 (gasinsulated switchgear)GIS全封闭组合电器 绝缘 电阻 管理
下载PDF
Estimation of the Type of Low Energy Discharge in GIS Adopting Characteristic Gas 被引量:7
7
作者 CHEN Jun LI Li +5 位作者 YAO Weijian TANG Yang ZHENG Xiaoguang YU Jianhui LUO Yunbai ZHOU Wenjun 《Wuhan University Journal of Natural Sciences》 CAS 2011年第4期319-324,共6页
In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper ai... In order to guarantee safe operations, low energy discharge within gas insulated switchgear (GIS) should be detected as soon as possible before they develop severely and cause final breakdown failures. This paper aims to present a GIS discharge diagnosis technique adopting gaseous decompositions. To reach this aim, needle-plate electrode and the sphere-plate electrode with metallic particles on the plate are designed to simulate two kinds of low energy discharge, namely, corona discharge and spark discharge, respectively. After sampling and analyzing the gases, different yields of gaseous by-products under different types of low energy discharge are obtained. Based on the decomposition mechanisms reported by previous researches and the experiment results, it can be concluded that S2OF10, SO2F2 , and SO2 can be used as the characteristic gas to identify low energy discharge; the increment of S2OF10 can indicate the occurrence of low energy discharges while the volume ratio between SO2F2 and SO2 can define the type of low energy discharge. 展开更多
关键词 gas insulated switchgear (GIS) SF6 decomposition low energy discharge DIAGNOSIS
原文传递