A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with flucona...A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.展开更多
An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracte...An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.展开更多
The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples...The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.展开更多
The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tande...The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines.展开更多
In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purificatio...In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purification.After modified quick,easy,cheap,effective,rugged,and safe(QuEChERS)extraction,extracts were directly injected to the TLX(TurboFlow Liquid Xcalibur)system and brought to TurboFlow™columns for on-line purification and then transferred to analytical column for further separation and analysis.TurboFlow™columns types,transfer flow rate,and transfer time were optimized.Limits of detection and limits of quantification of the method obtained for 15 pesticide residues were ranged between 0.2–1.0μg/kg and 0.5–2.0μg/kg in Chinese cabbage and cucumber samples.Recoveries of pesticide residues were in range of 75.3%–103.7%.Matrix effects for 15 pesticides were in range of 5.6%–106.6%.The developed method has been successfully used for the determination of 15 pesticide residues in real samples.展开更多
The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard fo...The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.展开更多
A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 s...A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.展开更多
A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibit...A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.展开更多
A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standa...A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.展开更多
A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glip...A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.展开更多
Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental condit...Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2―1.0 μg/kg) of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.展开更多
To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated first...To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).展开更多
In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoid...In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-O-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.展开更多
In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Pr...In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.展开更多
A simple, rapid, sensitive and reproducible method for enantiomer analysis of methamphetamine, amphetamine, cathinone and methcathinone was developed and validated. The compounds were extracted from equine plasma and ...A simple, rapid, sensitive and reproducible method for enantiomer analysis of methamphetamine, amphetamine, cathinone and methcathinone was developed and validated. The compounds were extracted from equine plasma and urine using a fast liquid-liquid extraction procedure. Only one milliliter plasma and one hundred microliter urine sample is needed for analysis. The extraction procedure had good recovery (>70%) and the matrix effect was negligible. Enantiomer differentiation and confirmation were achieved using liquid chromatography with chiral stationary phase and mass spectrometry detection. The method demonstrated excellent reproducibility with intra-day and inter-day precision of lower than 5%. The lower limits of detection for all of the compounds studied here were at low pg/mL level for both plasma and urine. This is the first report of the analysis of four chiral compounds in equine plasma and urine. Routine application was demonstrated for (S)- and (R)-enantiomer differentiation.展开更多
Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a si...Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a single step protein precipitation procedure and analyzed using a high performance liquid chromatography (HPLC) electrospray tandem mass spectrometer system. The compounds were eluted isocratically on an Inertsil ODS-SP column (100 min×2.1 mm, 3 μm), ionized using a positive ion atmospheric pressure electrospray ionization source and analyzed using multiple reaction monitoring (MRM) mode. The ion transitions monitored were m/z 412.8→q65.1 for butoconazole and m/z 453.4→230.3 for the internal standard. The chromatographic run time was 3.5 min per injection, with retention time of 2.47 rain and 2.15 min for butoconazole and repaglinide, respectively. The method was validated to be linear over the range of 20 to 8000 pg/mL (r〉0.999) by using a weighted (1/x2) quadratic regression. The mean recovery rate was more than 86.7%, and the intra- and inter-day precision of the quality control samples (QCs) was less than 8.3% and the accuracy ranged from 96.0% to 110.2%, which indicated that the quantitative method was reliable and accurate. The method is simple, rapid, and has been applied successfully to a pharmacokinetics study of butoconazole nitrate suppositories in healthy Chinese females.展开更多
Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In t...Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS.展开更多
An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction...An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).展开更多
With the long -term and irrational use of veterinary drugs and drug additives in the process of animal feeding, the veterinary drug resi- dues in animals and their additives can be ingested into the human body and pos...With the long -term and irrational use of veterinary drugs and drug additives in the process of animal feeding, the veterinary drug resi- dues in animals and their additives can be ingested into the human body and pose potential threat to human health. Detection of veterinary drug resi- dues are extremely important practical significance to protect the ecological environment and human health. In recent years, liquid chromatography -tandem mass spectrometry has been widely used in vetednary drug residue detection because of its applicability, qualitative and quantitative fea- tures as well as high sensitivity. This article summarized the application of liquid chromatography -tandem mass spectrometry in detection veterinary drug residues from feed, animal products, arid udne as well as illicit drugs and harmful additives.展开更多
Over the past decade, the use of hair specimens for the long-term detection of the alcohol biomarker ethyl glucuronide has been increasing in popularity and usage. We evaluated the usefulness of fingernail clippings a...Over the past decade, the use of hair specimens for the long-term detection of the alcohol biomarker ethyl glucuronide has been increasing in popularity and usage. We evaluated the usefulness of fingernail clippings as a suitable alterna-tive to hair for ethyl glucuronide detection. A liquid chromatography-tandem mass spectrometry method for the detection of ethyl glucuronide in fingernail clippings was fully validated and used to analyze the hair and/or fingernail specimens of 606 college-aged study participants. The limit of detection was 2 pg/mg, the limit of quantitation was 8 pg/mg and the method was linear from 8 to 2000 pg/mg. Intra- and inter-assay imprecision studies at three different concentrations (20, 40, 200 pg/mg) were all within 7.8% and all intra- and inter-assay bias studies at these levels were within 115.1% of target concentration. Ethyl glucuronide levels in fingernail (mean = 29.1 ± 55.6 pg/mg) were higher than ethyl glucuronide levels in hair (mean = 9.48 ± 22.3 pg/mg) and a correlation of the matched pairs was observed (r = 0.552, P < 0.01, n = 529). Evaluating each gender separately revealed that the correlation of male fingernail to male hair was large and significant (r = 0.782, P < 0.01, n = 195) while female hair to female fingernail was small yet sig-nificant (r = 0.249, P < 0.01, n = 334). The study results demonstrated that fingernail may be a suitable alternative to hair for ethyl glucuronide detection and may be the preferred sample type due to the lack of a gender bias.展开更多
文摘A sensitive, accurate and robust Liquid Chromatography Tandem Mass Spectrometry method has been developed and validated to measure voriconazole trough levels in human plasma. The plasma samples were mixed with fluconazole as an Internal Standard and directed to protein precipitation and drug extraction. An aliquot of 1 μl was injected into the chromatographic system and separated by the Acquity BEH C18 column at a flow rate of 0.30 ml/min in a gradient mobile phase consisting of acetonitrile, Ultrapure water (UPW), methanol and formic acid. Voriconazole was detected by a Triple Quadrupole Detector (TQD) operating on Multiple Reaction Monitoring (MRM) and a positive ion mode Electrospray ionization (ESI) Q1 mass: 350.1 m/z, Q3 mass: 281.1 m/z. Method linearity of the calibration curve (0.10 - 8.00 μg/ml) indicated a correlation coefficient r ≥ 0.99. The intra and inter-assay accuracy was within 85% - 115% and the intra and inter-assay precision was ≤5.76%. Voriconazole recovery percentage was between 97.69 - 119.62%. The method was successively applied in routine voriconazole TDM.
文摘An ultrahigh performance liquid chromatography-triple quadrupole tandem mass spectrometry(UPLC-MS/MS)was established to quickly and accurately determine the content of oleuropein in cosmetics.The samples were extracted with methanol-aqueous solution,and the mobile phase with methanol-formic acid solution(0.1 mol/L)=40∶60 was separated by Agilent ZORBAX Eclipse Plus C18(2.1 mm×50 mm×1.8μm-Micron)column temperature 30℃,flow rate 0.3 mL/min.The MS end was detected by electrospray negative mode ionization(ESI-)and multiple reaction monitoring(MRM)mode.The results show a good linear relationship in the range of 0.002~5 mg/L,with a correlation coefficient R2 of 0.999,5.Method recovery range from 84.2%~107.6%and the relative standard deviation RSD is 5.8%.The detection time is 5 min,the detection limit is 0.000,6 mg/L,and the limit of quantification is 0.002 mg/L.This method has the advantages of convenient operation,low quantification limit,high precision and good repeatability,and is suitable for measuring the content of oleuropein in many kinds of cosmetics.
基金This work was supported by“National Key Research and Development Program of China”(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D).
文摘The aim of this work was to develop an automated on-line solid phase extraction(SPE)with liquid chromatography-tandem mass spectrometry method for the detection of fifteen sulfonamides in pork and fish samples.Samples were extracted with 0.2%formic acid acetonitrile solution,purified by on-line SPE device with HLB column,then separated by XBridge C18 column,using 0.1%formic acid solution and acetonitrile as the mobile phase.Mass spectrometric data was acquired under multiple reaction monitoring(MRM)mode using positive ionization electrospray.Internal standard method was used in the quantification,good linear relationship was got in range of 0.1–100 ng/mL and correlation coefficient was higher than 0.9990.The limits of detection were in the range of 0.125–2.00g/kg and the limits of quantitation were in the range of 0.250–5.00g/kg.Recoveries of the method were in range of 78.3%–99.3%,relative standard deviation were lower than 10%.The method was simple,sensitivity,and could be used for routine supervision and analysis of fifteen sulfonamides in pork and fish.
文摘The measurement of urine catecholamine and metanephrine concentrations is important for biochemical screening and diagnosis of pheochromocytoma.The goal of this work was to develop a simple liquid chromatography-tandem mass spectrometry(LC-MS/MS)method for determining catecholamines and metanephrines in urine to replace an existing liquid chromatographic method using electrochemical detection.Urine samples were prepared using Oasis weak-cation-exchange cartridges.The eluate was analyzed on an Agilent ZORBAX Eclipse Plus Phenyl-Hexyl column in 3 min.Adrenaline,noradrenaline,dopamine,metanephrine,normetanephrine,and their deuterated internal standards were monitored in positive electrospray ionization mode by multiple reaction monitoring(MRM).No evidence of ion suppression was observed.The assay was linear up to 5μmol/L for adrenaline,5μmol/L for noradrenaline,6.1μmol/L for dopamine,5.6μmol/L for metanephrine,and 34.6μmol/L for normetanephrine,with lower limits of quantification of 5,5,12,6 and 7nmol/L,respectively.The intra-day and inter-day precisions for all analytes ranged from 0.59%to 4.64%and1.98%to 4.80%,respectively.External quality assurance samples were assayed and showed excellent agreement with the target values.This simple method provides an improved assay for determining urine catecholamines and metanephrines.
基金National Key Research and Development Program of China(Project No.2018YFC1603400)Science and Technology Program of Hebei Province(Project No.19225503D)Technical Support Project of State Administration for Market Regulation(Project No.2019YJ009).
文摘In this experiment,a liquid chromatography tandem mass spectrometry method was built to determine 15 pesticide residues in Chinese cabbage and cucumber samples based on online turbulent flow chromatography purification.After modified quick,easy,cheap,effective,rugged,and safe(QuEChERS)extraction,extracts were directly injected to the TLX(TurboFlow Liquid Xcalibur)system and brought to TurboFlow™columns for on-line purification and then transferred to analytical column for further separation and analysis.TurboFlow™columns types,transfer flow rate,and transfer time were optimized.Limits of detection and limits of quantification of the method obtained for 15 pesticide residues were ranged between 0.2–1.0μg/kg and 0.5–2.0μg/kg in Chinese cabbage and cucumber samples.Recoveries of pesticide residues were in range of 75.3%–103.7%.Matrix effects for 15 pesticides were in range of 5.6%–106.6%.The developed method has been successfully used for the determination of 15 pesticide residues in real samples.
文摘The most suitable bio-analytical method based on liquid liquid extraction has been developed and validated for quantification of Rasagiline in human plasma. Rasagiline-13C3 mesylate was used as an internal standard for Rasagiline. Zorbax Eclipse Plus C18 (2.1 mm × 50 mm, 3.5 um) column provided chromatographic separation of analyte followed by detection with mass spectrometry. The method involved simple isocratic chromatographic condition and mass spectrometric detection in the positive ionization mode using an API-4000 system. The lotal run time was 3.0 min. The proposed method has been validated with the linear range of 5 12000 pg/mL for Rasagiline. The intra-run and inter-run precision values were within 1.3% 2.9% and 1.6% 2.2% respectively for Rasagiline. The overall recovery for Rasagiline and Rasagiline-13C3 mesylate analog was 96.9% and 96.7% respectively. This validated method was successfully applied to the bioequivalence and pharmacokinetic study of human volunteers under fasting condition.
基金supported by the Natural Science Foundation of Zhejiang Province,China(No.LY17C200009)the Foundation of Zhejiang Educational Committee(No.Y201328477)
文摘A highly sensitive method was developed for the simultaneous determination of 8 steroid hormones in high-fat fish tissues using ultra high performance liquid chromatography-tandem mass spectrometry(UPLC-MS/MS).The 8 steroid hormones were extracted from the tissues with diethyl ether.Differing from other common purification methods,the extract solutions were cleaned by gel permeation chromatography(GPC) using ethyl acetate-cyclohexane solution(1:1,v/v) as the mobile phase.The separation of target compounds was carried out by a BEH C18 column and a gradient elution consisting of acetonitrile and 0.2% aqueous formic acid(v/v).The compounds were detected under the multiple reaction monitoring(MRM) mode and quantified with external standard method.This method was validated with respect to linearity,specificity,accuracy and precision.A linearity with correlation coefficient larger than 0.995 was achieved in the range of 0.5 to 50 ng m L^(-1).The average recoveries at the spiked levels of 1.0,5.0,and 10.0 μg kg^(–1) varied between 81.7% and 90.8%,with the relative standard deviations(n=5) ranged from 3.50% to 10.0%.The limit of quantification(LOQ) for 8 steroid hormones ranged from 0.2 to 1.5 μg kg^(-1).It was concluded that this method can be successfully applied for the determination of 8 steroid hormones in complicated matrices including high-fat fish tissues.
基金supported by the United States Public Health Service Cancer Center Support Grant P30 CA022453Novartis for providing the study drug and isotope-labeled internal standard and providing financial support for the clinical study
文摘A rapid, sensitive, and robust reversed-phase liquid chromatography with tandem mass spectrometry method was developed and validated for the determination of total and unbound ceritinib, a secondgeneration ALK inhibitor, in patient plasma and brain tumor tissue samples. Sample preparation involved simple protein precipitation with acetonitrile. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C_(18) column using a 4-min gradient elution consisting of mobile phase A(0.1% formic acid in water) and mobile phase B(0.1% formic acid in acetonitrile), at a flow rate of 0.4 m L/min. Ceritinib and the internal standard([^(13)C_6]ceritinib) were monitored using multiple reaction monitoring mode under positive electrospray ionization. The lower limit of quantitation(LLOQ) was 1 n M of ceritinib in plasma. The calibration curve was linear over ceritinib concentration range of 1–2000 n M in plasma. The intra-and interday precision and accuracy were within the generally accepted criteria for bioanalytical method( o15%).The method was successfully applied to assess ceritinib brain tumor penetration, as assessed by the unbound drug brain concentration to unbound drug plasma concentration ratio, in patients with brain tumors.
文摘A reliable,selective and sensitive liquid chromatography tandem mass spectrometry method was developed and validated for the quantification of lamotrigine in human plasma using lamotrigine13C3,d3 as an internal standard.Analyte and internal standard were extracted from human plasma by solid-phase extraction and detected in positive ion mode by tandem mass spectrometry with electrospray ionization(ESI) interface.Chromatographic separation was performed on a Chromolith s SpeedROD;RP-18e column(50-4.6 mm i.d.) using acetonitrile:570.1 mM ammonium formate solution(90:10,v/v) as the mobile phase at a flow rate of 0.500 mL/min.The calibration curves were linear over the range of 5.02-1226.47 ng/mL with the lower limit of quantitation validated at 5.02 ng/mL.The analytes were found stable in human plasma through three freeze(-20℃)-thaw(ice-cold water bath) cycles and under storage on bench-top in ice-cold water bath for at least 6.8 h,and also in the mobile phase at 10℃ for at least 57h.The method has shown good reproducibility,as the intra-and inter-day precisions were within 3.0%,while the accuracies were within 76.0% of nominal values.The validated LC-MS/MS method was applied for the evaluation of pharmacokinetic and bioequivalence parameters of lamotrigine after an oral administration of 50mg lamotrigine tablet to thirty-two healthy adult male volunteers.
文摘A sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry(LC- ES1-MS/MS) was used for the simultaneous determination of metformin and glimepiride in beagle dog plasma with glipizide as internal standard(IS). After simplified protein precipitation with methanol, both the analytes and IS were chromatographed on a Zorbax CN column via gradient elution with methanol(containing 5 mmol/L ammonium ace- tate) and 5 mmol/L aqueous ammonium acetate as the mobile phase. Detection was performed by multiple reaction monitoring(MRM) scanning via ESI source operated in positive ionization mode. Specificity, linearity, accuracy, pre- cision, recovery, matrix effect and stability were validated for metformin and glimepiride in beagle dog plasma. The calibration curves were linear in a concentration range of 10-10000 ng/mL for metformin and 4-4000 ng/mL for glimepiride with both correlation coefficients higher than 0.99. The recoveries obtained for the analytes and IS were all between 82.7% and 101.2%. The method exhibited excellent performance in terms of selectivity, robustness, short analytical time and simplicity of sample preparation. Finally, the proposed method was applied to a bioequivalence study of self-made bilayer tablet and commercial formulation containing 500 mg of metformin and 1 mg of glimepi- ride in beagle dogs.
基金Supported by the Projects of the General Administration of Quality Supervision,Inspection and Quarantine of China(No.2007IK157)
文摘Eighteen sex hormones in antler velvet were determined by high performance liquid chromatography tandem mass spectrometry.The solid phase extraction was applied to eliminating the matrix effect.The experimental conditions were examined and optimized.Under the optimal conditions,the proposed method provides the good linearities and determination limits(0.2―1.0 μg/kg) of the analytes investigated.The recoveries ranging from 72.3% to 149.5% were obtained for the target analytes at two concentration levels.This method was applied to the determination of eighteen sex hormones in different kinds of antler velvet samples and the obtained results are satisfactory.The results indicate that the proposed method is suitable for the determination of sex hormones in antler velvet samples.
文摘To assess uncertainty of determination of MC-LR in environmental samples by solid phase extraction- ultra performance liquid chromatography- tandem mass spectrometry,the sources of the uncertainty were evaluated firstly,and the expanded uncertainty was calculated finally.The results show that when MC-LR concentration in the water samples was 0.50 μg/L,the expanded uncertainty was 0.00628 μg/L(k=2).
文摘In this paper, a sensitive and specific liquid chromatography-electrospray ionisation-mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and determination of seven flavonoids, namely epimedin A, epimedin B, epimedin C, icariin, sagittatoside B, 2"-O-rhamnosyl icariside II, and baohuoside I in Epimedium from different sources.
文摘In this study, a high-performance liquid chromatograph and an electrospray ionization (ESI) triple quadrupole mass spectrometry (TQ MS) detector were used to scan Oriental Beauty tea of different grades and prices. Principle component analysis (PCA) of the profiling data was performed for pattern recognition, clearly showing that the proposed MS profiling method was able to classify Oriental Beauty tea into different grades. The component mass ions primarily responsible for the separation were selected with high loading strength in the PCA for subsequent identification with tandem mass (MS/MS). Caffeine, citrate and salicylate were verified, whereas certain other compounds remained ambiguous. Regression analysis considering caffeine, citrate and salicylate showed a linear relationship between the prices of the Oriental Beauty tea with an adjusted R2 of 0.84. If all the selected marker ions (in addition to caffeine, citrate and salicylate) could have been identified and incorporated into regression analysis, a stronger relationship could have been confirmed. These results suggest that metabolomics can facilitate the determination of real markers in the quality control of Oriental Beauty tea, and may lead to the further application of metabolomics in other food quality controls.
文摘A simple, rapid, sensitive and reproducible method for enantiomer analysis of methamphetamine, amphetamine, cathinone and methcathinone was developed and validated. The compounds were extracted from equine plasma and urine using a fast liquid-liquid extraction procedure. Only one milliliter plasma and one hundred microliter urine sample is needed for analysis. The extraction procedure had good recovery (>70%) and the matrix effect was negligible. Enantiomer differentiation and confirmation were achieved using liquid chromatography with chiral stationary phase and mass spectrometry detection. The method demonstrated excellent reproducibility with intra-day and inter-day precision of lower than 5%. The lower limits of detection for all of the compounds studied here were at low pg/mL level for both plasma and urine. This is the first report of the analysis of four chiral compounds in equine plasma and urine. Routine application was demonstrated for (S)- and (R)-enantiomer differentiation.
基金supported by National Science&Technology Specific Projects in the 12th Five-Year Plan of China(No.2011ZX09302-002-01)
文摘Summary: A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed and validated for the determination of butoconazole in human plasma. Human plasma samples of 0.2 μL were pretreated by a single step protein precipitation procedure and analyzed using a high performance liquid chromatography (HPLC) electrospray tandem mass spectrometer system. The compounds were eluted isocratically on an Inertsil ODS-SP column (100 min×2.1 mm, 3 μm), ionized using a positive ion atmospheric pressure electrospray ionization source and analyzed using multiple reaction monitoring (MRM) mode. The ion transitions monitored were m/z 412.8→q65.1 for butoconazole and m/z 453.4→230.3 for the internal standard. The chromatographic run time was 3.5 min per injection, with retention time of 2.47 rain and 2.15 min for butoconazole and repaglinide, respectively. The method was validated to be linear over the range of 20 to 8000 pg/mL (r〉0.999) by using a weighted (1/x2) quadratic regression. The mean recovery rate was more than 86.7%, and the intra- and inter-day precision of the quality control samples (QCs) was less than 8.3% and the accuracy ranged from 96.0% to 110.2%, which indicated that the quantitative method was reliable and accurate. The method is simple, rapid, and has been applied successfully to a pharmacokinetics study of butoconazole nitrate suppositories in healthy Chinese females.
基金the supports of the National Key Research and Development of BioBased Rubber(2017YFB0306900&2017YFB0306901)the National Natural Science Foundation of China(51673012)+1 种基金the Fundamental Research Funds for the Central Universities(PYBZ1828)the Beijing Technology and Business Universtiy Youth Scholoars Funds(PXM2019014213000007)。
文摘Taraxacum kok-saghyz(TKS)is rich in natural rubber(NR),a natural organic macromolecular compound composed of cis-1,4-polyisoprene,and may become the second NR-bearing plant for biochemical engineering development.In this paper,a rapid and quantitative ultra-high performance liquid chromatography tandem mass spectrometry(UHPLCMS/MS)method was established for determination of macromolecular biosynthesis substrate(dimethylallyl pyrophosphate,DMAPP)and initiator(farnesyl pyrophosphate,FPP)contained in TKS.A Kromasil C18 chromatographic column was used for separation,and the multi-reaction monitoring mode(MRM)of triple quadrupole mass spectrometry was used for detection.Quantification was performed by external calibration method.The results showed that the limit of detection(LOD)and the limit of quantitation(LOQ)of DMAPP were 2.42μg/L and 7.26μg/L,respectively,and the LOQ and the LOD of FPP were 1.02μg/L and 3.05μg/L,respectively.At a concentration of 1—1000μg/L,both analytes had good determination coefficients(>0.999)of calibration curve.The recoveries of DMAPP and FPP were between 99.0%and 117.1%.In real samples detection,the contents of DMAPP and FPP in TKS samples were between 23.32—82.77μg/L and 12.03—85.67μg/L,respectively.Thus,this approach is a reliable method to quantify DMAPP and FPP in TKS.
基金Supported by the Project of Chinese Academy of Inspection and Quanrantine(No.2010JK001)the Project of Xinjiang Entry-exit Inspection and Quarantine Bureau, China(No.2010XK0033)
文摘An accurate and sensitive method for the simultaneous determination of gibberellic acid(GA3), gibberellin A4(GA4) and gibberellin A7(GA7) residues in tomato paste was developed by coupling solid phase extraction to high performance liquid chromatography-tandem mass spectrometry(LC-MS/MS) with electrospray ionization based stable isotope dilution analysis(SIDA). The isotope labeled internal standard can compensate for the losses during the extraction and cleanup steps and for discrimination due to ion suppression. After extraction from methanol, hydrophile lipophilic balance(HLB) solid phase extraction(SPE) column was tested for the capacity of the cleanup of the tomato paste in compared with C18 SPE column which is the common way to the detection of GAs, and the former gained better result. Spiked experiments were performed in the non-contaminated tomato pastes and the recoveries of GA3, GA4 and GA7 were 42.6%―75.0% in external standard method(ESM) and 91.1%―103.8% in internal standard method(ISM) respectively. The validities of this method were investigated and good analytical performance for the three GAs was obtained, including low limits of method detection(2 ng/g for GA3 and GA4, 0.3 ng/g for GA7), excellent linear dynamic ranges(5―500 ng/g for GA3 and GA4, 1―100 ng/g for GA7) and good relative standard deviation ranges(4.8%―9.4% for the intra-day test and 3.5%―11.9% for the inter-day test).
文摘With the long -term and irrational use of veterinary drugs and drug additives in the process of animal feeding, the veterinary drug resi- dues in animals and their additives can be ingested into the human body and pose potential threat to human health. Detection of veterinary drug resi- dues are extremely important practical significance to protect the ecological environment and human health. In recent years, liquid chromatography -tandem mass spectrometry has been widely used in vetednary drug residue detection because of its applicability, qualitative and quantitative fea- tures as well as high sensitivity. This article summarized the application of liquid chromatography -tandem mass spectrometry in detection veterinary drug residues from feed, animal products, arid udne as well as illicit drugs and harmful additives.
文摘Over the past decade, the use of hair specimens for the long-term detection of the alcohol biomarker ethyl glucuronide has been increasing in popularity and usage. We evaluated the usefulness of fingernail clippings as a suitable alterna-tive to hair for ethyl glucuronide detection. A liquid chromatography-tandem mass spectrometry method for the detection of ethyl glucuronide in fingernail clippings was fully validated and used to analyze the hair and/or fingernail specimens of 606 college-aged study participants. The limit of detection was 2 pg/mg, the limit of quantitation was 8 pg/mg and the method was linear from 8 to 2000 pg/mg. Intra- and inter-assay imprecision studies at three different concentrations (20, 40, 200 pg/mg) were all within 7.8% and all intra- and inter-assay bias studies at these levels were within 115.1% of target concentration. Ethyl glucuronide levels in fingernail (mean = 29.1 ± 55.6 pg/mg) were higher than ethyl glucuronide levels in hair (mean = 9.48 ± 22.3 pg/mg) and a correlation of the matched pairs was observed (r = 0.552, P < 0.01, n = 529). Evaluating each gender separately revealed that the correlation of male fingernail to male hair was large and significant (r = 0.782, P < 0.01, n = 195) while female hair to female fingernail was small yet sig-nificant (r = 0.249, P < 0.01, n = 334). The study results demonstrated that fingernail may be a suitable alternative to hair for ethyl glucuronide detection and may be the preferred sample type due to the lack of a gender bias.