Aiming at the problems of large energy consumption and serious pollution of winter heating existing in the rural buildings in Southern Xinjiang,a combined active-passive heating system was proposed,and the simulation ...Aiming at the problems of large energy consumption and serious pollution of winter heating existing in the rural buildings in Southern Xinjiang,a combined active-passive heating system was proposed,and the simulation software was used to optimize the parameters of the system,according to the parameters obtained from the optimization,a test platform was built and winter heating test was carried out.The simulation results showed that the thickness of the air layer of 75 mm,the total area of the vent holes of 0.24 m^(2),and the thickness of the insulation layer of 120 mm were the optimal construction for the passive part;solar collector area of 28 m^(2),hot water storage tank volume of 1.4 m^(3),mass flow rate of 800 kg/h on the collector side,mass flow rate of 400 kg/h on the heat exchanger side,and output power of auxiliary heat source of 5∼9 kWwere the optimal constructions for active heating system.Test results showed that during the heating period,the system could provide sufficient heat to the room under different heating modes,and the indoor temperature reached over 18°C,which met the heating demand.The economic and environmental benefits of the system were analyzed,and the economic benefits of the systemwere better than coal-fired heating,and the CO_(2) emissionswere reduced by 3,292.25 kg compared with coalfiredheating.The results of the study showed that the combinedactive-passiveheating systemcouldeffectively solve the heating problems existing in rural buildings in Southern Xinjiang,and it also laid the theoretical foundation for the popularization of the combined heating systems.展开更多
The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the stu...The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.展开更多
A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the s...A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.展开更多
High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and eco...High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and economic operation of boiler. An on-line life monitoring model of high-temperature heating surface was set up according to the well-known L-M formula of the creep damages. The tube wall metal temperature and working stress was measured by on-line monitoring, and with this model, the real-time calculation of the life expenditure of the heating surface tube bundles were realized. Based on the technique the on-line life monitoring and management system of high-temperature heating surface was developed for a 300 MW utility boiler. An effective device was thus suggested for the implementation of the safe operation and the condition-based maintenance of utility boilers.展开更多
The equation for radiation heat transfer in a multiple combustion boiler furnace with nuidized bed and pulverized coal firing is derived from direct calculation of radiation heat transfer.
Superheater tubes temperature control is a necessity for long lifetime, high efficiency and high load following capability in boiler. This study reports a new approach for the control strategy design of boilers with s...Superheater tubes temperature control is a necessity for long lifetime, high efficiency and high load following capability in boiler. This study reports a new approach for the control strategy design of boilers with special shields. The presented control strategy is developed based on radiation thermal shields with low emissivity coefficient and high reflectivity or scattering coefficient. In order to simulate the combustion event in boiler and heat transfer to superheater tubes, an effective set of computational fluid dynamic (CFD) codes is used. Results indicate a successful identification of over- heated zones on platen superheater tubes and effect of radiation shields for solving this problem.展开更多
Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficien...Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficiencyand raises coal consumption. Additionally, if the exhaust gas temperatureis too high, a lot of water must be used to cool the flue gas for the wetflue gas desulfurization system to function well, which has an impact onthe power plant’s ability to operate profitably. It is consequently vital totake steps to lower exhaust gas temperatures in order to increase boilerefficiency and decrease the amount of coal and water used. Desulfurizationperformance may be enhanced and water use can be decreased by reasonableflue gas characteristics at the entry. This study analyzed the unit’s energyconsumption, investment, and coal savings while proposing four couplingstrategies for regulating flue gas temperature and waste heat recovery. Agraded flue gas conditioning and waste heat recovery plan was presentedunder the condition of ensuring high desulfurization efficiency, along withthe notion of minimizing energy loss owing to energy inflow temperaturedifference. Numerical results show that the proposed methods improved thesystem performance and reduced the water consumption and regulated theboiler temperature.展开更多
In order to determine the sensitivity of influencing factors on NOx emission in gas-fired heating and hot water combi-boilers,the orthogonal method was adopted in this paper.Five predominant factors affecting the form...In order to determine the sensitivity of influencing factors on NOx emission in gas-fired heating and hot water combi-boilers,the orthogonal method was adopted in this paper.Five predominant factors affecting the formation of NOx and four levels were selected to be analyzed,including the diameter of flue restrictor,power of fan,ejection distance of nozzle,aperture of nozzle and relative humidity of air.The test plan was designed by employing L16(45)orthogonal array,and 16 groups of experiments were conducted.The test results were analyzed with range analysis and variance analysis.The results indicated that the power of fan has the greatest influence on the formation of NOx of the gas-fired combi-boilers,followed by the diameter of flue restrictor and the relative humidity of air,while the ejection distance of nozzle and aperture of nozzle have little effect on the formation of NOx.In addition,with the selected optimal combination of five factors,a minimum NOx volume fraction is obtained,which confirms the superiority of the orthogonal test.The research finding has a certain guiding significance for the reduction of NOx formation of gas-fired heating and hot water combi-boiler.展开更多
基金This study was funded by the Xinjiang Production and Construction Corps Southern Xinjiang Key Industry Support Program Project,Grant Number 2019DB007.
文摘Aiming at the problems of large energy consumption and serious pollution of winter heating existing in the rural buildings in Southern Xinjiang,a combined active-passive heating system was proposed,and the simulation software was used to optimize the parameters of the system,according to the parameters obtained from the optimization,a test platform was built and winter heating test was carried out.The simulation results showed that the thickness of the air layer of 75 mm,the total area of the vent holes of 0.24 m^(2),and the thickness of the insulation layer of 120 mm were the optimal construction for the passive part;solar collector area of 28 m^(2),hot water storage tank volume of 1.4 m^(3),mass flow rate of 800 kg/h on the collector side,mass flow rate of 400 kg/h on the heat exchanger side,and output power of auxiliary heat source of 5∼9 kWwere the optimal constructions for active heating system.Test results showed that during the heating period,the system could provide sufficient heat to the room under different heating modes,and the indoor temperature reached over 18°C,which met the heating demand.The economic and environmental benefits of the system were analyzed,and the economic benefits of the systemwere better than coal-fired heating,and the CO_(2) emissionswere reduced by 3,292.25 kg compared with coalfiredheating.The results of the study showed that the combinedactive-passiveheating systemcouldeffectively solve the heating problems existing in rural buildings in Southern Xinjiang,and it also laid the theoretical foundation for the popularization of the combined heating systems.
基金Supported by Key Scientific Research Projects of Sichuan Provincial Department of Technology (2010JY0165)Key Special Scientific Research Projects of Mianyang City of Sichuan Province (09Y003-13)Key Scientific Research Projects of Sichuan Provincial Department of Education (2003A112)
文摘The feasibility of adopting a balanced energy mix mode (domestic solar energy, biogas, coal-fired boiler and radiant floor heating) was proposed. Taking a typical rural residence in Zhengzhou City for example, the study through theoretical analysis and calculation showed that such a balanced energy mix is an economic way and efficient in saving energy and reducing air pollution, and elaborated the theoretical feasibility of popularizing such a heat supply mode in rural areas.
文摘A mathematical model was built for simulating an innovative design system combined solar energy with biogas boiler for floor radiant heating and fuel. Effects of the ambient air temperature on the performance of the system had been examined. And the results also support theoretical feasibility of the system.
文摘High-temperature heating surface such as superheater and reheater of large-sized utility boiler all experiences a relatively severe working conditions. The failure of boiler tubes will directly impact the safe and economic operation of boiler. An on-line life monitoring model of high-temperature heating surface was set up according to the well-known L-M formula of the creep damages. The tube wall metal temperature and working stress was measured by on-line monitoring, and with this model, the real-time calculation of the life expenditure of the heating surface tube bundles were realized. Based on the technique the on-line life monitoring and management system of high-temperature heating surface was developed for a 300 MW utility boiler. An effective device was thus suggested for the implementation of the safe operation and the condition-based maintenance of utility boilers.
文摘The equation for radiation heat transfer in a multiple combustion boiler furnace with nuidized bed and pulverized coal firing is derived from direct calculation of radiation heat transfer.
文摘Superheater tubes temperature control is a necessity for long lifetime, high efficiency and high load following capability in boiler. This study reports a new approach for the control strategy design of boilers with special shields. The presented control strategy is developed based on radiation thermal shields with low emissivity coefficient and high reflectivity or scattering coefficient. In order to simulate the combustion event in boiler and heat transfer to superheater tubes, an effective set of computational fluid dynamic (CFD) codes is used. Results indicate a successful identification of over- heated zones on platen superheater tubes and effect of radiation shields for solving this problem.
文摘Flue gas heat loss accounts for a significant component of theoverall heat loss for coal-fired boilers in power plants. The flue gas absorbsmore heat as the exhaust gas temperature rises, which reduces boiler efficiencyand raises coal consumption. Additionally, if the exhaust gas temperatureis too high, a lot of water must be used to cool the flue gas for the wetflue gas desulfurization system to function well, which has an impact onthe power plant’s ability to operate profitably. It is consequently vital totake steps to lower exhaust gas temperatures in order to increase boilerefficiency and decrease the amount of coal and water used. Desulfurizationperformance may be enhanced and water use can be decreased by reasonableflue gas characteristics at the entry. This study analyzed the unit’s energyconsumption, investment, and coal savings while proposing four couplingstrategies for regulating flue gas temperature and waste heat recovery. Agraded flue gas conditioning and waste heat recovery plan was presentedunder the condition of ensuring high desulfurization efficiency, along withthe notion of minimizing energy loss owing to energy inflow temperaturedifference. Numerical results show that the proposed methods improved thesystem performance and reduced the water consumption and regulated theboiler temperature.
基金funded by the Key Project in the Tianjin Science and Technology Pillar Program under grant number 19YFZCCG00550。
文摘In order to determine the sensitivity of influencing factors on NOx emission in gas-fired heating and hot water combi-boilers,the orthogonal method was adopted in this paper.Five predominant factors affecting the formation of NOx and four levels were selected to be analyzed,including the diameter of flue restrictor,power of fan,ejection distance of nozzle,aperture of nozzle and relative humidity of air.The test plan was designed by employing L16(45)orthogonal array,and 16 groups of experiments were conducted.The test results were analyzed with range analysis and variance analysis.The results indicated that the power of fan has the greatest influence on the formation of NOx of the gas-fired combi-boilers,followed by the diameter of flue restrictor and the relative humidity of air,while the ejection distance of nozzle and aperture of nozzle have little effect on the formation of NOx.In addition,with the selected optimal combination of five factors,a minimum NOx volume fraction is obtained,which confirms the superiority of the orthogonal test.The research finding has a certain guiding significance for the reduction of NOx formation of gas-fired heating and hot water combi-boiler.