Neutron response functions and detection efficiency of a spherical proton recoil proportional counter 被引量:2
1
作者 Wang Xinhua He Tie +4 位作者 Guo Haiping An Li Zhen Pu Mou Yunfeng Yang Jian 《Nuclear Science and Techniques》 SCIE CAS CSCD 2010年第6期330-333,共4页
The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the respon... The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation. 展开更多
关键词 正比计数器 响应函数 探测效率 反冲质子 中子谱 球形 GEANT4 检测效率
下载PDF
Development of a spherical tissue equivalent proportional counter for neutron monitoring
2
作者 姜志刚 袁永刚 +1 位作者 王和义 陈华 《Nuclear Science and Techniques》 SCIE CAS CSCD 2015年第6期90-94,共5页
A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal ^(241)Am al... A spherical tissue equivalent proportional counter(TEPC) for neutron monitoring has been developed. It was properly designed to produce a uniform electric field intensity around the anode wire. An internal ^(241)Am alpha source was adopted for lineal energy calibration. The TEPC was characterized in terms of dose equivalent response in a standard ^(252)Cf neutron field, and was tested with 2.45 MeV neutrons. Microdosimetric spectra, frequency mean lineal energy and dose-average mean lineal energy of 2.45 MeV neutrons were obtained and compared with FLUKA Monte Carlo simulation results. The measurement and simulation results agreed well. The mean quality factor and dose equivalent values evaluated from the 2.45 MeV neutron measurement were in good agreement with the recommended effective quality factor and ambient dose equivalent H*(10),respectively. Preliminary results have proved the availability of the developed TEPC for neutron monitoring. 展开更多
关键词 组织等效正比计数器 中子场 正比计数管 监测 种球 剂量响应 蒙特卡罗模拟 剂量当量
下载PDF
利用数字化仪实现放射性气体^(85)Kr核素活度浓度的绝对测量
3
作者 拓飞 路天翔 +3 位作者 张明 周倩倩 郭贵银 王硕 《计量学报》 CSCD 北大核心 2024年第10期1570-1575,共6页
基于中国计量科学研究院建立的长度补偿法充气正比计数器绝对测量系统,利用CAEN公司开发的DT5730型数字化仪替代多套传统模拟电子学插件,并通过数字化仪对β信号进行采集、重建和数据离线分析,开展^(85)Kr放射性惰性气体活度浓度的绝对... 基于中国计量科学研究院建立的长度补偿法充气正比计数器绝对测量系统,利用CAEN公司开发的DT5730型数字化仪替代多套传统模拟电子学插件,并通过数字化仪对β信号进行采集、重建和数据离线分析,开展^(85)Kr放射性惰性气体活度浓度的绝对测量。实验研究了各种条件的影响,通过对正比计数器端效应、正比计数器壁效应、本底、噪声、死时间漏计数和阈值以下计数进行修正,最终得到^(85)Kr活度浓度绝对测量结果。在相同阈值、主放大倍数100倍、气压50.5 kPa,工作电压1675 V和1700 V的条件下,数字化仪测量和电子学插件测量^(85)Kr放射性活度浓度的相对偏差分别为0.83%和0.74%。测量结果在不确定度范围内一致,证明数字化仪可有效替代传统电子学插件实现放射性惰性气体^(85)Kr活度浓度的绝对测量。 展开更多
关键词 电离辐射计量 数字化仪 ^(85)Kr 正比计数器 放射性活度浓度 绝对测量
下载PDF
流气式低本底α/β测量仪的串道特征及干扰修正
4
作者 李美丽 覃连敬 +2 位作者 蒋岚 郭小敏 梁贵渊 《辐射研究与辐射工艺学报》 CAS CSCD 2024年第2期96-105,共10页
研究了一系列α、β金属平面源、粉末源及薄层样法自制面源在流气式低本底α/β测量仪上的串道现象。结果显示:^(90)Sr-^(90)Y金属面源以及 ^(14)C,^(137)Cs,^(90)Sr-^(90)Y, ^(40)K粉末源β对α通道的串道比均在0.1%以下,基本可以忽略... 研究了一系列α、β金属平面源、粉末源及薄层样法自制面源在流气式低本底α/β测量仪上的串道现象。结果显示:^(90)Sr-^(90)Y金属面源以及 ^(14)C,^(137)Cs,^(90)Sr-^(90)Y, ^(40)K粉末源β对α通道的串道比均在0.1%以下,基本可以忽略不计;α金属平面源串道比大小规律表现为 ^(210)Po<^(209)Po<^(239)Pu<^(239)Pu-^(241)Am混合源<241Am,范围为3.49%~25.4%,发射不同能量粒子的α金属源的串道比差异较大。由于衰变过程产生的内转换电子、俄歇电子以及X射线等在β道产生响应,241Am源的串道比明显高于其他源,241Am粉末源的串道比随单位面积质量厚度增加而增大。α粒子对β通道的串道现象较明显,并与样品制源方式有关,主要是不同制源方式造成的自吸收差异导致的,总体有α粉末源串道比>薄层样法自制α面源>α金属平面源,测量时应重点考虑α粒子对β放射性的串道干扰。通过210Po加标样及牡蛎样品经放化分析制成的电镀源验证,对待测样品源进行一定厚度的铝箔或纸片覆盖,可以有效的减小α粒子对β通道的串道干扰;也可以直接利用串道比对测量计数进行修正,此时需要考虑待测样品源和串道比刻度源的一致性,否则会导致修正结果的偏差较大。 展开更多
关键词 流气式低本底α/β测量仪 串道干扰 串道比 金属平面源 粉末源
下载PDF
基于时间差法的位置灵敏3He正比计数管位置分辨性能研究
5
作者 王欣悦 刘国荣 +3 位作者 李井怀 梁庆雷 周浩 田园 《核技术》 EI CAS CSCD 北大核心 2024年第6期65-75,共11页
中子定位技术可用于乏燃料后处理流程监测,以避免发生核临界安全事故。利用蒙特卡罗(Monte Carlo,MC)算法模拟了不同中子发射方式、^(3)He气压、管径、慢化体厚度等对位置灵敏^(3)He正比计数管位置分辨能力和探测效率的影响。对于管径为... 中子定位技术可用于乏燃料后处理流程监测,以避免发生核临界安全事故。利用蒙特卡罗(Monte Carlo,MC)算法模拟了不同中子发射方式、^(3)He气压、管径、慢化体厚度等对位置灵敏^(3)He正比计数管位置分辨能力和探测效率的影响。对于管径为2.54 cm、灵敏区长80 cm、^(3)He气压为405300 Pa的位置灵敏^(3)He正比计数管,MC模拟结果表明:轴向各处位置分辨能力相同,对热中子点源的位置分辨极限为0.17 cm;慢化体厚5 cm且^(244)Cm源紧贴慢化体外壁时中子探测效率为3.0%,位置分辨为9.25 cm。用时间差法测试了^(244)Cm源在灵敏区不同位置、源管距、慢化体厚度等情况下此位置灵敏^(3)He正比计数管对^(244)Cm源的位置分辨能力与探测效率,测试结果表明:实验装置的理论位置分辨极限可达2.64 cm,当慢化体厚5 cm且^(244)Cm源紧贴慢化体外壁时位置分辨为18.50 cm,为理论值的一半。 展开更多
关键词 位置灵敏 3He正比计数管 中子定位 蒙特卡罗模拟 时间差法 位置分辨
下载PDF
超低本底流气式正比计数器在样品总α/β测量中串道影响修正
6
作者 胥海亮 陈诚 +4 位作者 王亮 朱珠 郭旭影 王茜 粟琨璞 《辐射防护》 CAS CSCD 北大核心 2024年第5期461-468,共8页
超低本底流气式正比计数器是样品总α/β测量的理想探测器,但本身具有较强的串道现象,影响样品测量的准确性。系统研究了流气式正比计数器在同一质量厚度、不同241 Am和40 K质量分数下α→β、β→α串道影响,建立了总α/β串道修正的... 超低本底流气式正比计数器是样品总α/β测量的理想探测器,但本身具有较强的串道现象,影响样品测量的准确性。系统研究了流气式正比计数器在同一质量厚度、不同241 Am和40 K质量分数下α→β、β→α串道影响,建立了总α/β串道修正的二元方程,并与遮盖修正法进行对比,对自制的25组α/β模拟粉末样品进行了测量和串道修正。结果显示α→β串道影响较大,修正因子随着α计数率的变化并非恒定值;β→α串道修正因子影响较小,其平均值为0.001;遮盖修正法对模拟粉末样品中β测量结果的修正效果较差,其相对偏差绝对值介于1.4%~45.0%;二元方程修正法对模拟粉末样品中β测量结果的修正效果较好,其相对偏差绝对值介于0~5.5%。 展开更多
关键词 超低本底流气式正比计数器 串道修正 二元方程修正法
下载PDF
月壤中子辐射环境原位探测任务与载荷设计
7
作者 程雅苹 郭万磊 +2 位作者 唐振宇 杨勇 杨晓宁 《空间科学与试验学报》 CSCD 2024年第1期63-71,共9页
由于月球没有大气层和全球性的磁场保护,使得高能宇宙线直接与月壤物质的原子核发生散裂反应产生大量中子。月球中子既是载人登月和国际月球科研站辐射防护的主要对象之一,也可用于月球水资源勘查及月球起源、演化历史研究。迄今只有阿... 由于月球没有大气层和全球性的磁场保护,使得高能宇宙线直接与月壤物质的原子核发生散裂反应产生大量中子。月球中子既是载人登月和国际月球科研站辐射防护的主要对象之一,也可用于月球水资源勘查及月球起源、演化历史研究。迄今只有阿波罗17任务测量了月壤2米深度内的中子数密度,文章提出将中子探测载荷部署在月壤钻取后形成的钻井中的任务设想,相比阿波罗任务,月壤钻井中子探测在原位、近实时、多能区等方面具有创新性。基于氦-3正比计数管技术的月壤中子探测载荷重量0.9 kg、功率9 W,对月壤内部水的灵敏度可达500微克每克。月壤钻井中子载荷将极大的丰富月球探测任务的科学与工程产出。文章中的相关方案和技术还可应用于后续其他地外天体的深空探测任务。 展开更多
关键词 深空探测 月壤中子辐射 月球水冰 氦-3正比计数管 载荷设计
下载PDF
^(3)He proportional counter development for thermal neutron detection 被引量:1
8
作者 Mohamed Fares Adnane Messai +4 位作者 Samir Begaa Maameri Salem Kassida Negara Mohamed Yacine Debili Mohammed Messaoudi 《Radiation Detection Technology and Methods》 CSCD 2021年第2期264-272,共9页
Neutron detection is used in a wide range of applications in nuclear physics,radiation protection,nuclear fuel cycle,reactor instrumentation,security and industrial measurement.Among the detectors used in this field,w... Neutron detection is used in a wide range of applications in nuclear physics,radiation protection,nuclear fuel cycle,reactor instrumentation,security and industrial measurement.Among the detectors used in this field,we notice the gas-filled 3He proportional counters which have been one of the main detecting tools for thermal and cold neutron detection for many years.This last characteristic has ensured that this detector is one of the best tools for thermal neutron flux measurements in a nuclear reactor control.In the instrumentation and detection laboratory of the Nuclear Research Center,of Birine,we are working toward the design and the development of this type of detectors,indeed,several prototypes of neutron detectors have been realized including the 3He proportional counters.Through this paper,we will present the experimental steps and the obtained results to carry out a 3He proportional counter prototype that was fully developed and tested in our laboratory.A comparison study was made between our detector and a commercial cylindrical 3He neutron detector which was considered in this work as a reference detector:LND252(3He)-PC.The results showed that the characteristics of the gas amplification and the counting plateau for the two counters reference LND 252(3He)-PC and our prototype was of the same order of scale.The experimental tests show that our developed prototype perfect fit with the standard International Electrotechnical Commission(IEC,www.iec.ch)in the operating principle,the technology adopted and obtained technical specifications. 展开更多
关键词 Neutrons detectors 3He proportional counters Counting plateau DISCRIMINATION Gas amplification
原文传递
Boron-10 lined proportional counter development for thermal neutron detection
9
作者 Mohamed Fares Mohamed Yacine Debili +3 位作者 Mohammed Messaoudi Samir Begaa Kassida Negara Adnane Messai 《Radiation Detection Technology and Methods》 CSCD 2021年第1期110-116,共7页
Purpose Neutrons detection is of paramount importance in nuclear physics experiments,reactor physics,monitoring and control of nuclear reactors and in radiation protection.Among the neutron detectors used are Proporti... Purpose Neutrons detection is of paramount importance in nuclear physics experiments,reactor physics,monitoring and control of nuclear reactors and in radiation protection.Among the neutron detectors used are Proportional Counters(PC to BF3,boron deposition,3He),Our Detection and Measurements laboratory has embarked on a project to develop,design and build proportional counters with boron deposition mainly for gas filling,several prototypes of which have been produced.Method This work presents the Boron-10 Lined Proportional Counters(PC),developed and produced in the Detection and Measurements Department(DDM19).The PC was designed by adopting,for the electrodes,a stainless steel cathode 0.5 mm thick and a gold-plated tungsten anode with diameter of 25μm.The detectors are filled with an Ar-CH4 mixture(10%)at a pressure of 20 cmHg.The boron deposition is performed by the technique of electrophoresis.Result The results obtained using the DDM19 prototype PC(Detector produced in our Detection and Measurement laboratory,2019),show the advantage of electrophoresis as a better boron deposition technique,and the limitation of the surface mass of 10B to optimal values is around 0.5 at 0.6 mg/cm2.Conclusions The characteristics of the gas amplification in the mixture(Ar-CH4(CH410%)),were measured by different methods and compared with the values of the proportional reference counter LND232.The counting plates for the two reference meters LND232 and our DDM19 prototype from 200 to 300 V have slopes ranging from 6.5 to 10%/100 V,and gas amplification factors from 1436 to 1380,respectively. 展开更多
关键词 Neutron detector Boron-10 lined proportional counter Reference LND232 Boron deposition technique
原文传递
TEPC及其中子剂量测量应用研究进展
10
作者 肖枫 范子野 刘法邦 《防化研究》 2024年第1期1-7,26,共8页
基于组织等效正比计数器(Tissue-Equivalent Proportional Counter,TEPC)的辐射监测装置在中子周围剂量当量测量领域展现出独特优势和应用潜力,成为各国新型中子剂量测量技术的研究热点。本文阐述了TEPC基本工作原理、各种技术路线的工... 基于组织等效正比计数器(Tissue-Equivalent Proportional Counter,TEPC)的辐射监测装置在中子周围剂量当量测量领域展现出独特优势和应用潜力,成为各国新型中子剂量测量技术的研究热点。本文阐述了TEPC基本工作原理、各种技术路线的工作机理和特点优势,综述了基于TEPC的中子周围剂量当量测量技术的国内外研究和应用现状,并对关键技术的未来发展进行了展望。 展开更多
关键词 中子周围剂量当量 组织等效正比计数器 微剂量学 气体电子倍增器
下载PDF
用于热中子探测的正比管性能研究 被引量:13
11
作者 廖俊辉 谢一冈 +5 位作者 陈元柏 郭萍 郭兰英 欧阳群 凌球 陆双桐 《核电子学与探测技术》 CAS CSCD 北大核心 2007年第2期367-371,共5页
简要对最常用的三种正比管的热中子探测效率及灵敏度进行了实验比较,还给出了一维3He位置灵敏热中子探测器的初步实验研究结果。
关键词 热中子探测 正比管 探测效率 灵敏度 位置灵敏效应
下载PDF
气体正比计数管测量^(37)Ar的效率研究 被引量:4
12
作者 向永春 龚建 +4 位作者 李伟 卞直上 郝樊华 王红侠 王茜 《核技术》 EI CAS CSCD 北大核心 2007年第10期828-832,共5页
采用大体积的正比计数探测器和能谱分析方法对37Ar的测量效率进行了研究。主要分析了影响正比计数管效率的阈修正、端效应和壁效应三大因素。结果表明,阈修正系数与峰面积的计算方法有关。当计数管压力大于200kPa时,计数管的壁效应修正... 采用大体积的正比计数探测器和能谱分析方法对37Ar的测量效率进行了研究。主要分析了影响正比计数管效率的阈修正、端效应和壁效应三大因素。结果表明,阈修正系数与峰面积的计算方法有关。当计数管压力大于200kPa时,计数管的壁效应修正小于1%,可以忽略。最后给出了计数管的效率的计算公式。 展开更多
关键词 气体正比计数管 ^37Ar 能谱法 效率
下载PDF
正比计数器漏电流研究 被引量:4
13
作者 陈国云 魏志勇 +3 位作者 方美华 杨永常 辛勇 张紫霞 《南京航空航天大学学报》 EI CAS CSCD 北大核心 2010年第5期670-674,共5页
利用电介质物理、高电压绝缘以及电磁学相关知识分析了正比计数器填充气体和绝缘材料中的漏电流与击穿问题。选择适当的材料可使正比计数器填充气体中的漏电流达10-17A量级,其绝缘材料中的体漏电流达10-12~10-15A量级,考虑其极化效应... 利用电介质物理、高电压绝缘以及电磁学相关知识分析了正比计数器填充气体和绝缘材料中的漏电流与击穿问题。选择适当的材料可使正比计数器填充气体中的漏电流达10-17A量级,其绝缘材料中的体漏电流达10-12~10-15A量级,考虑其极化效应后还将更小。正比计数器的漏电流与其输出信号电流(10-9A量级)相比小103倍以上,而绝缘材料表面的清洁、干燥程度直接决定其中的表面漏电流。正比计数器填充气体和绝缘材料中的漏电流对输出的影响可忽略且不至于击穿,可应用于强辐射场中的剂量测量。 展开更多
关键词 正比计数器 填充气体 绝缘材料 漏电流
下载PDF
内充气正比计数管系统绝对测量^(87)Kr放射性活度浓度 被引量:7
14
作者 李奇 常永福 +5 位作者 解峰 王世联 李琦 师全林 张子斌 李雪松 《原子能科学技术》 EI CAS CSCD 北大核心 2006年第4期443-446,共4页
本工作研制建立1套气体放射性活度绝对测量装置———内充气正比计数管系统。对该系统的坪特性、本底、死时间、端效应和壁效应等性能进行了测试。在此基础上,采用该系统对放射性气体87Kr的放射性活度浓度进行了绝对测量,测得值为40.64(... 本工作研制建立1套气体放射性活度绝对测量装置———内充气正比计数管系统。对该系统的坪特性、本底、死时间、端效应和壁效应等性能进行了测试。在此基础上,采用该系统对放射性气体87Kr的放射性活度浓度进行了绝对测量,测得值为40.64(1±0.9%)Bq/mL。 展开更多
关键词 内充气正比计数管 绝对测量 放射性活度浓度 87^Kr
下载PDF
产氚回路中氚的在线监测研究 被引量:3
15
作者 官锐 翁葵平 +3 位作者 任兴碧 谢波 侯建平 刘云怒 《核技术》 CAS CSCD 北大核心 2010年第3期215-218,共4页
描述一套产氚回路中氚的在线监测装置——流气式正比计数系统。测试该系统的坪曲线、本底、探测效率等性能后,开展了氚在线监测实验研究。结果表明,该系统性能稳定,控制好测量条件,可作产氚回路中氚的在线监测设备。
关键词 流气式正比计数系统 监测
下载PDF
基于BF_3正比管的宽量程脉冲中子探测技术 被引量:5
16
作者 马烈华 向艳军 +2 位作者 艾杰 马景芳 李涛 《强激光与粒子束》 EI CAS CSCD 北大核心 2017年第9期136-141,共6页
介绍了一种基于BF_3正比计数管的宽量程脉冲中子探测技术。该技术采用多通道、组合式的BF_3管阵列中子探测器组,以适应产额变化范围较宽的脉冲中子测试场合,并同时兼顾测量下限。基于该技术研制了一套BF_3阵列中子探测系统并应用于脉冲... 介绍了一种基于BF_3正比计数管的宽量程脉冲中子探测技术。该技术采用多通道、组合式的BF_3管阵列中子探测器组,以适应产额变化范围较宽的脉冲中子测试场合,并同时兼顾测量下限。基于该技术研制了一套BF_3阵列中子探测系统并应用于脉冲中子源的测试,实验结果表明,该系统的脉冲中子测量范围可达5个数量级(56~8×10~6),测量下限低、输出信号清晰,证明了该技术的可行性和有效性。 展开更多
关键词 BF3正比计数管 中子产额 中子探测
下载PDF
涂硼正比计数管中热中子响应函数理论计算及模拟验证 被引量:7
17
作者 方美华 魏志勇 +3 位作者 张紫霞 陈国云 黄三玻 雷升杰 《南京航空航天大学学报》 EI CAS CSCD 北大核心 2012年第1期81-86,共6页
对涂硼正比计数管的热中子响应函数计算公式进行了理论推导。在圆柱形几何结构下,热中子在垂直柱面径向入射和任意角度入射两种情况时的响应函数得到了一种普适性的响应函数表达式,并选取正比管典型尺寸(内径10 mm,涂层厚度3μm)进行... 对涂硼正比计数管的热中子响应函数计算公式进行了理论推导。在圆柱形几何结构下,热中子在垂直柱面径向入射和任意角度入射两种情况时的响应函数得到了一种普适性的响应函数表达式,并选取正比管典型尺寸(内径10 mm,涂层厚度3μm)进行蒙特卡罗模拟,对理论推导公式进行模拟验证,理论计算结果与模拟结果基本一致。研究表明,在垂直柱面任意角度入射的情况下,热中子的响应率随入射方向与圆柱中心距离y的增加呈规律性分布,即先增加后迅速降低,有一个峰值。在本文尺寸下,正向峰值在9 900~1 000μm之间,而反向峰值在9 700~9 800μm之间,反向较正向数值上偏小。此外,对理论计算值与模拟值、理论值与实验值的偏差进行了分析,并给出了解释。 展开更多
关键词 涂硼正比管 蒙特卡罗模拟 响应函数 热中子 响应率
下载PDF
混凝土配合比设计方案对比分析 被引量:13
18
作者 刘军 王玲玲 +3 位作者 王东山 李和平 姜晓冬 孙凯 《混凝土》 CAS CSCD 2003年第12期25-28,共4页
 详尽叙述普通混凝土配合比设计法,粉煤灰混凝土超量取代法,逆填配比设计法等几种混凝土配合比设计思想并给出流程图和计算实例。在强度基本相近的情况下,逆填配比设计法所配制出的混凝土比传统的配比方法坍落度提高约20mm,且坍落度经...  详尽叙述普通混凝土配合比设计法,粉煤灰混凝土超量取代法,逆填配比设计法等几种混凝土配合比设计思想并给出流程图和计算实例。在强度基本相近的情况下,逆填配比设计法所配制出的混凝土比传统的配比方法坍落度提高约20mm,且坍落度经时损失较少,利于泵送施工及提高工程质量。由于寻求混凝土固态材料在最佳级配时的最大混合单位重,逆填配比设计法比普通混凝土配合比设计节约水泥36%,比粉煤灰混凝土超量取代法节约水泥25%,同时比超量取代法多用工业废渣粉煤灰37%。 展开更多
关键词 逆填配比设计法 最密堆积 强度 流动性 经济分析
下载PDF
新型涂硼正比计数器研制及其实验测试和模拟计算 被引量:4
19
作者 张紫霞 魏志勇 +3 位作者 朱立 方美华 陈国云 强鹏 《原子能科学技术》 EI CAS CSCD 北大核心 2015年第3期545-551,共7页
本文将^10 B粉与1,2-二氯乙烷溶剂、芳华树脂粘结剂混合研制了中子灵敏层^10 B膜,以此制作一新型涂硼正比计数器。为增加探测效率,除管内壁涂硼外,在管内增置了14片双面涂硼环氧薄片,并用^241 Am-Be源测试了其性能。活度为3.7×10^9... 本文将^10 B粉与1,2-二氯乙烷溶剂、芳华树脂粘结剂混合研制了中子灵敏层^10 B膜,以此制作一新型涂硼正比计数器。为增加探测效率,除管内壁涂硼外,在管内增置了14片双面涂硼环氧薄片,并用^241 Am-Be源测试了其性能。活度为3.7×10^9 Bq的^241 Am-Be源实验表明:此新型涂硼正比计数器坪长约150V,坪斜为8.2%/100V(750-900V);工作电压为800V时测得新型涂硼正比计数器的计数率为50s^-1,灵敏度为0.71cm^2。与管内壁仅涂硼的正比计数器相比,新型涂硼正比计数器中子灵敏面积增加到3.15倍后,探测器坪长从80 V增至150 V,坪斜从12.4%/100 V改进到7.58%/100V,灵敏度提高到2.63倍。同时,以基于蒙特卡罗方法的Geant4平台,模拟计算单能中子及^241 Am-Be源中子照射包裹高密度聚乙烯慢化材料的新型涂硼正比计数器的响应和探测效率。^241 AmBe源模拟结果和实验结果吻合较好。实验测试及模拟结果表明,涂硼技术与增加灵敏面积相结合的正比计数器的设计较成功。 展开更多
关键词 中子 涂硼正比计数器 坪曲线 探测效率
下载PDF
^37Ar活度比对测量 被引量:2
20
作者 曹琳 亢武 +6 位作者 向永春 卞直上 李伟 郝樊华 Riedmann R A Purtschert R Loosli H H 《核技术》 CAS CSCD 北大核心 2009年第1期14-18,共5页
37Ar是地下核爆确定的、明确的指示剂,目前已经被CTBTO确定为现场视察的核查核素。中国工程物理研究院核物理与化学研究所研制了适合现场视察的37Ar探测系统--移动式37Ar快速探测系统(Movable37Ar Rapid Detection System,MARDS),该系... 37Ar是地下核爆确定的、明确的指示剂,目前已经被CTBTO确定为现场视察的核查核素。中国工程物理研究院核物理与化学研究所研制了适合现场视察的37Ar探测系统--移动式37Ar快速探测系统(Movable37Ar Rapid Detection System,MARDS),该系统采用LLC方法(Low Level Decay Counting)测量37Ar的活度。目前国际上尚无37Ar活度测量的标准装置,因此开展37Ar活度比对测量是一项很有必要的工作。本文介绍了我所(中国工程物理研究院核物理与化学研究所,INPC)与瑞士伯尔尼大学大气与环境物理研究所(KUP)开展的37Ar活度比对测量工作。比对测量的结果说明MARDS测量37Ar活度的方法和结果有很高的可信度,为MARDS系统应用于现场视察提供了技术支持。 展开更多
关键词 37Ar 活度测量 比对测量 正比计数管