The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples e...The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples exist the optimum annealing temperature and optimum frequency at which the relative change in ribbon voltage is strongest, and the sensitivity of the magnetic response of the annealed Fe_89Zr_7B_4 ribbon is two order of magnitude larger than that of the annealed Fe_86Zr_10 B4 ribbon. The effect of magnetic properties and structural characteristics on giant magneto-impedance was discussed.展开更多
A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-imp...A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-impedance ratio is 475% and magnetic sensitivity of about 120%/Oe (1 Oe=80 A/m) at 20MHz, which is helpful to improve the sensitivity of magnetic sensor. The performances of the sensor were carefully studied in open-loop and closed-loop with negative feedback. The full measurement range of the magnetic field detection is 1.7-4 Oe presently, and the sensitivity achieves 176 mV/Oe. The sensor with negative feedback shows excellent linearity and good stability. The designed magnetic sensor can be applied in geomagnetic field measurement.展开更多
The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to pro...The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction.展开更多
SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potentia...SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potential applications in industry. Amorphous (and nanocrys-talline) soft magnetic alloys have very large magnetic permeability, when an ac driving currentand an external magnetic field (EMF) are applied, the EMF will damp the magnetic fluxchange caused by the ac driving current, thus the magnetic permeability will decrease; as a re-展开更多
利用单辊快淬法制备了Co Fe Ni Si B非晶薄带,经过400 A/mm2电流密度、20 ms脉冲间隔条件下的脉冲退火后具有较好的弱磁场灵敏性能。以该带材为磁敏材料,基于纵向驱动方式研制了一种巨磁阻抗(GMI)磁传感器,该磁传感器尺寸小、灵敏度高...利用单辊快淬法制备了Co Fe Ni Si B非晶薄带,经过400 A/mm2电流密度、20 ms脉冲间隔条件下的脉冲退火后具有较好的弱磁场灵敏性能。以该带材为磁敏材料,基于纵向驱动方式研制了一种巨磁阻抗(GMI)磁传感器,该磁传感器尺寸小、灵敏度高、频率响应好,±0.05 m T弱磁场范围内灵敏度可达到44.15 V/m T,在高灵敏度小型磁传感器领域具有较大的应用潜力。展开更多
文摘The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples exist the optimum annealing temperature and optimum frequency at which the relative change in ribbon voltage is strongest, and the sensitivity of the magnetic response of the annealed Fe_89Zr_7B_4 ribbon is two order of magnitude larger than that of the annealed Fe_86Zr_10 B4 ribbon. The effect of magnetic properties and structural characteristics on giant magneto-impedance was discussed.
文摘A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-impedance ratio is 475% and magnetic sensitivity of about 120%/Oe (1 Oe=80 A/m) at 20MHz, which is helpful to improve the sensitivity of magnetic sensor. The performances of the sensor were carefully studied in open-loop and closed-loop with negative feedback. The full measurement range of the magnetic field detection is 1.7-4 Oe presently, and the sensitivity achieves 176 mV/Oe. The sensor with negative feedback shows excellent linearity and good stability. The designed magnetic sensor can be applied in geomagnetic field measurement.
基金Supported by the National Natural Science Foundation of China(60874100)
文摘The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction.
文摘SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potential applications in industry. Amorphous (and nanocrys-talline) soft magnetic alloys have very large magnetic permeability, when an ac driving currentand an external magnetic field (EMF) are applied, the EMF will damp the magnetic fluxchange caused by the ac driving current, thus the magnetic permeability will decrease; as a re-
文摘利用单辊快淬法制备了Co Fe Ni Si B非晶薄带,经过400 A/mm2电流密度、20 ms脉冲间隔条件下的脉冲退火后具有较好的弱磁场灵敏性能。以该带材为磁敏材料,基于纵向驱动方式研制了一种巨磁阻抗(GMI)磁传感器,该磁传感器尺寸小、灵敏度高、频率响应好,±0.05 m T弱磁场范围内灵敏度可达到44.15 V/m T,在高灵敏度小型磁传感器领域具有较大的应用潜力。