Giant Magneto-Impedance Effect in Fe_(96-x)B_4 (x=7 or 10) Nanocrystalline Ribbons 被引量:1
1
作者 Zhichao LU and Wei HAN (National Amorphous and Nanocrystalline Alloy Engineering Research Center, Center Iron and Steel Research Institute, Beijing 100081, China) Deren LI (Department of Physics, Northeastern University, Shenyang 110006, China) 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2000年第2期148-150,共3页
The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples e... The total ribbon voltage of as-quenched and annealed Fe96-xZr_xB_4 (x=7 or 10) ribbons has been measured as a function of applied dc field and drive current frequency. The experimental results show that both samples exist the optimum annealing temperature and optimum frequency at which the relative change in ribbon voltage is strongest, and the sensitivity of the magnetic response of the annealed Fe_89Zr_7B_4 ribbon is two order of magnitude larger than that of the annealed Fe_86Zr_10 B4 ribbon. The effect of magnetic properties and structural characteristics on giant magneto-impedance was discussed. 展开更多
关键词 giant magneto-impedance Effect in Fe x=7 or 10 x)B4 X Nanocrystalline Ribbons gmi
下载PDF
Giant magneto-impedance and permeability in Fe_(89)Zr_6Hf_1B_4 ribbons
2
作者 YUXiaojun HUJifan +3 位作者 LIBo QINHongwei WANGDonglin LIWei 《Rare Metals》 SCIE EI CAS CSCD 2005年第2期174-177,共4页
The giant magneto-impedance (GMI) effect associated with the variation of transverse permeability for the ribbons Fe89Zr6Hf1B4 with different annealing temperatures T-A = 793, 823, 893, 923, 993, and 1033 K was invest... The giant magneto-impedance (GMI) effect associated with the variation of transverse permeability for the ribbons Fe89Zr6Hf1B4 with different annealing temperatures T-A = 793, 823, 893, 923, 993, and 1033 K was investigated. There is an optimum annealing temperature TA = 993 K for obtaining the largest GMI effect for the ribbons Fe89Zr6Hf1B4. The magneto-impedance GMI (Z) = (Z(H) - Z(0))/Z(0) for the ribbon with T-A = 993 K can reach -55.09% at a frequency f = 900 kHz under H = 7162 A/m. The relative changes of the real part of transverse permeability Delta mu'/mu'(0) = (mu'(H)- mu'(0))/mu'(0) under H = 7162 A center dot m(-1) at f = 1 MHz are -78.83%, -89.98% and -94.77 % for Fe89Zr6Hf1B4 ribbons with T-A = 823, 893, and 993 K, respectively. The strong GMI effect is accompanied by the large change of transverse permeability. A large magnetoreaetance GMI(X) = (X (H) - X (0))/X (0) of -81.09% can be obtained at f = 100 kHz under H = 7162 A/m for the ribbon with T-A = 993 K. Meanwhile, this present result gave an experimental support to the previous concept / assumption that the positive peak in the field dependence of magneto-impedance is connected to the peak of transverse permeability with varying fields. 展开更多
关键词 giant magneto-impedance PERMEABILITY Fe89Zr6Hf1B4 ribbons annealing temperature
下载PDF
GIANT MAGNETO-IMPEDANCE OF PATTERNED FeSiB/Cu/FeSiB TRI-LAYER FILMS
3
作者 X.H. Mao, Y. Zhou, M.S. Wu and B.C. CaiKey Laboratory for Thin Film and Microfabrication of Ministry of Education, Research Institute of Micro/ Nanometer Science and Technology, Shanghai Jiaotong University, Shanghai 200030, China 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 2003年第5期327-331,共5页
Sensitive magnetic field sensor with good performances can be fabricated utilizing the giant magneto-impedance (GMI) effect of soft magnetic multi-layer thin films. The transverse and longitudinal GMI effect in patter... Sensitive magnetic field sensor with good performances can be fabricated utilizing the giant magneto-impedance (GMI) effect of soft magnetic multi-layer thin films. The transverse and longitudinal GMI effect in patterned FeSiB/Cu/FeSiB tri-layer films with the change of external magnetic field and frequency were studied at the same time. The change of the impedance of the films with the external magnetic fieldand frequency was shown. Comparing the longitudinal and transverse effect, the transverse effect has a larger linear range from zero magnetic field to a quite large magnetic field at all frequencies, and the change still were not saturated until the external magnetic field reached 1.2×104A/m, which illustrated that the films can be utilized to detect larger magnetic fields than now presented GMI sensors. 展开更多
关键词 giant magneto-impedance effect FeSiB/Cu/FeSiB films tri- layer films
下载PDF
基于GMI效应的磁传感器研究与发展现状 被引量:9
4
作者 郝建华 郑全普 +1 位作者 胡然 丁丹 《国外电子测量技术》 2011年第4期20-26,共7页
巨磁阻抗(GMI)效应的出现,使磁传感器在弱磁检测领域的小型化、高灵敏度、快速响应和低功耗方面成为可能,基于GMI效应的磁传感器具有广泛的应用发展前景,是近年来磁传感器领域的研究热点之一。本文从不同敏感材料类型的角度介绍了巨磁... 巨磁阻抗(GMI)效应的出现,使磁传感器在弱磁检测领域的小型化、高灵敏度、快速响应和低功耗方面成为可能,基于GMI效应的磁传感器具有广泛的应用发展前景,是近年来磁传感器领域的研究热点之一。本文从不同敏感材料类型的角度介绍了巨磁阻抗磁传感器的国内外研究现状,着重对传感器的敏感材料、结构形式、处理电路及性能做了介绍,并指出了GMI磁传感器研究存在的问题及将来的发展趋势,为巨磁阻抗传感器的实现提供有益的参考。 展开更多
关键词 巨磁阻抗(gmi) 磁传感器 弱磁检测
下载PDF
GMI磁传感器内部灵敏度与噪声特性研究 被引量:2
5
作者 蒋颜玮 房建成 王三胜 《测试技术学报》 2011年第2期183-188,共6页
建立了非晶带GMI敏感元件的灵敏度和噪声理论模型,计算了其灵敏度和磁噪声在不同易轴方向和外磁场应用条件下的响应特性.通过改变易轴方向、外磁场及直流偏置场对非晶带敏感元件进行了优化,其内部磁噪声达到了fT/Hz水平.分析了内部灵敏... 建立了非晶带GMI敏感元件的灵敏度和噪声理论模型,计算了其灵敏度和磁噪声在不同易轴方向和外磁场应用条件下的响应特性.通过改变易轴方向、外磁场及直流偏置场对非晶带敏感元件进行了优化,其内部磁噪声达到了fT/Hz水平.分析了内部灵敏度、工作点和磁噪声水平对GMI磁传感器性能的影响,结果表明,在GMI磁传感器设计时,应综合考虑灵敏度和噪声的指标,采取折衷的方案对敏感元件进行优化是合理的,这为实现高灵敏度、低噪声、稳定性好的GMI磁传感器提供了理论依据. 展开更多
关键词 巨磁阻抗(gmi) 磁传感器 非晶带 灵敏度 磁噪声
下载PDF
热处理对Fe_(79.5)P_(12)C_6Cu_(0.5)Mo_(0.5)Si_(1.5)软磁合金薄带的巨磁致阻抗效应(GMI)的影响
6
作者 库万军 王新颜 +1 位作者 张传历 朱静 《功能材料》 EI CAS CSCD 北大核心 1997年第5期552-554,共3页
研究了不同温度热处理对Fe79.5P12C6Cu0.5Mo0.5Si1.5的巨磁阻抗的影响,发现GMI不仅与磁导率有关,而且也受到磁各向异性的作用。
关键词 巨磁致阻抗效应 热处理 软磁合金 薄带
下载PDF
多层膜的巨磁阻抗(GMI)效应
7
作者 董承远 陈世朴 《磁性材料及器件》 CAS CSCD 2002年第4期14-16,共3页
巨磁阻抗多层膜相比单层膜具有不可比拟的优越性,它可以在很低的频率范围获得非常明显的巨磁阻抗效应。综述了多层膜GMI效应的研究现状,着重探讨了材料、膜尺寸及绝缘层隔离对多层膜GMI效应的影响,并且探讨了多层膜GMI效应的物理本质。
关键词 GIM 多层膜 巨磁阻抗 绝缘层隔离 三明治结构
下载PDF
Three-dimension micro magnetic detector based on GMI effect
8
作者 魏双成 邓甲昊 +1 位作者 韩超 杨雨迎 《Journal of Beijing Institute of Technology》 EI CAS 2014年第2期143-146,共4页
The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to pro... The giant magneto-impedance(GMI)effect of amorphous wire was analyzed theoretically.The amorphous wire had strong GMI effect in the stimulation of sharp pulse of 680kHz and18 mV.A pulse generator was designed to provide high frequency pulse to a magnetic impedance(MI)element.The induced voltage on the pickup coil wound on the amorphous wire was sampled and held with a detect circuit using analog switch.A stable magnetic sensor was constructed.A three-dimension micro magnetic field detector was designed with a central controller MSP430F449.High stability and sensitivity were obtained in the MI sensor with the detect circuit.Experiment results showed that the resolution of the detector was 1nT in the full scale of±2 Oe and the detector worked stably from the room temperature to about 80℃.A small ferromagnetic target was detected by the three-dimension detector in laboratory environment without magnetic shielding.The target moving direction was ascertained with the wave shape of axis parallel in that direction. 展开更多
关键词 giant magneto-impedance(gmi)effect amorphous wire three dimension detector pulse generator analog switch
下载PDF
一种GMI传感器目标探测模型
9
作者 肖晶 段修生 师菁菁 《传感器与微系统》 CSCD 2015年第2期50-53,共4页
为了使巨磁阻抗(GMI)传感器能够在军事目标探测中发挥灵敏度高、探测距离远的特点,对其输出曲线处理方法进行改进,提出了基于幅值功率特征和小波特征的目标探测模型,既充分利用了敏感材料的GMI效应,又保证了测量的精度。最后通过模拟目... 为了使巨磁阻抗(GMI)传感器能够在军事目标探测中发挥灵敏度高、探测距离远的特点,对其输出曲线处理方法进行改进,提出了基于幅值功率特征和小波特征的目标探测模型,既充分利用了敏感材料的GMI效应,又保证了测量的精度。最后通过模拟目标定位实验验证了该模型的有效性。该模型操作简单,易于实现,且定位精度较高,在目标探测与跟踪领域有很大的发展空间。 展开更多
关键词 巨磁阻抗传感器 信号处理 曲线拟合 小波分析 BP神经网络
下载PDF
基于GMI传感器的钢板漏磁无损检测 被引量:3
10
作者 陈德禄 张清 +3 位作者 阮建中 石桂芬 何明辉 赵振杰 《磁性材料及器件》 北大核心 2014年第5期46-48,共3页
基于漏磁检测技术,采用巨磁阻抗GMI传感器搭建了钢板无损检测系统,对镀锡DI材带钢上直径大小为60~140μm的缺陷进行了检测。GMI传感器敏感核心元件采用的是直径16μm、长为5mm的Co68.15Fe4.35Si12.5B15非晶玻璃包裹丝,以非线性非对角模... 基于漏磁检测技术,采用巨磁阻抗GMI传感器搭建了钢板无损检测系统,对镀锡DI材带钢上直径大小为60~140μm的缺陷进行了检测。GMI传感器敏感核心元件采用的是直径16μm、长为5mm的Co68.15Fe4.35Si12.5B15非晶玻璃包裹丝,以非线性非对角模式工作,具有高灵敏度、快速响应、非接触、功耗小、无磁滞等优点。实验表明,这套测试系统在提离值0.5~3 mm范围内能够精确地检测出直径大于60μm的缺陷,根据测量信号可以分析出缺陷所在的位置和大小。实验结果较好地符合磁偶极子模型。 展开更多
关键词 钢板 缺陷 巨磁阻抗传感器 漏磁 无损检测
下载PDF
宽线性GMI磁传感器的研制
11
作者 周初凯 郑金菊 +3 位作者 金林枫 杨光 王红洲 赵静 《传感器与微系统》 CSCD 北大核心 2014年第7期73-74,78,共3页
用单辊快淬法制备的Fe76Si7.6B9.5P5C1.9非晶合金薄带,在540℃空气中退火后具有宽线性的磁敏特性。利用纵向驱动的方法研制一种巨磁阻抗(GMI)传感器,该磁传感器重复性好,迟滞误差小,在-0.3^+0.3 kA·m-1范围具有比较好的线性度,灵... 用单辊快淬法制备的Fe76Si7.6B9.5P5C1.9非晶合金薄带,在540℃空气中退火后具有宽线性的磁敏特性。利用纵向驱动的方法研制一种巨磁阻抗(GMI)传感器,该磁传感器重复性好,迟滞误差小,在-0.3^+0.3 kA·m-1范围具有比较好的线性度,灵敏度达到12.65mV/A·m-1。 展开更多
关键词 巨磁阻抗效应 磁传感器 Fe基非晶薄带 线性度 灵敏度
下载PDF
电流退火及长度对玻璃包裹丝GMI效应的影响
12
作者 蒋申骏 潘海林 赵振杰 《华东师范大学学报(自然科学版)》 CAS CSCD 北大核心 2017年第3期114-119,共6页
采用高频感应加热熔融快淬法制各了Fe_(73.5)Cu_(1.0)Nb_(3.0)Si_(13.5)B_9非晶玻璃包裹丝.首先对制备态包裹丝进行电流退火,结果发现电流密度为4.2×10~7 A/m^2时,退火得到的玻璃包裹丝性能最佳,原因是此时有合适的纳米晶体积比例... 采用高频感应加热熔融快淬法制各了Fe_(73.5)Cu_(1.0)Nb_(3.0)Si_(13.5)B_9非晶玻璃包裹丝.首先对制备态包裹丝进行电流退火,结果发现电流密度为4.2×10~7 A/m^2时,退火得到的玻璃包裹丝性能最佳,原因是此时有合适的纳米晶体积比例.进而研究了长度对其磁性和巨磁阻抗效应的影响.结果表明,随着长度的减小,微丝的各项异性场增大,磁阻抗比减小,采用退磁场模型给予了合理解释. 展开更多
关键词 巨磁阻抗 电流退火 玻璃包裹丝 长度
下载PDF
Improvement of giant magneto impedance of Co-rich melt extraction wires by stress-current annealing
13
作者 ZHANG Shuling SUN Jianfei XING Dawei 《Rare Metals》 SCIE EI CAS CSCD 2011年第4期327-331,共5页
In order to improve the giant magneto impedance (GMI) of Co-rich wires for high sensitive sensor applications, Co6sFe4.sSilsBlz5 wires were prepared by melt an extraction technique and subjected to Joule stress-curr... In order to improve the giant magneto impedance (GMI) of Co-rich wires for high sensitive sensor applications, Co6sFe4.sSilsBlz5 wires were prepared by melt an extraction technique and subjected to Joule stress-current anneal treatments with different tensile slresses applied. And then their GMI response was investigated at a frequency range from 0.1 to 13 MHz. It was found through the comparison of results that the GMI effect of these wires had been improved through stress-current anneal treatments, because the tensile stress applied on these Co-rich wires introduced magnetoelastic energy and increased anisotropy, which improved the circular permeability and GMI effect. Their impedance ratio AZ/Z increased from 244% to 480.9% at 7 MHz and the field sensitivity increased to 0.83%/(A/m) at 5 MHz, when a tensile stress of 244 MPa was applied at an anneal current of 100 mA for 10 min. It was therefore concluded that these annealed wires were suitable for high sensitive sensor applications. 展开更多
关键词 amorphous magnetic materials cobalt alloys WIRES giant magneto-impedance effect ANNEALING
下载PDF
Effect of glass removal on the GMI effect of Co_(71.8)Fe_(4.9)Nb_(0.8)Si_(7.5)B_(15) amorphous glass-covered wires
14
作者 CHEN Zheng BA Shan LI Deren LU Zhichao ZHOU Shaoxiong 《Rare Metals》 SCIE EI CAS CSCD 2006年第z1期633-636,共4页
During the past several years, giant magneto-impedance effect (GMI) in amorphous wires has generated growing interest in the science community because of their applications in sensors. The giant magneto-impedance effe... During the past several years, giant magneto-impedance effect (GMI) in amorphous wires has generated growing interest in the science community because of their applications in sensors. The giant magneto-impedance effect in Co71.8Fe4.9Nb0.8Si7.5B15 amorphous glass-covered wires (AGCW) consists of strong changes in the high frequency impedance with a small DC magnetic field. When f=1 MHz, there is no GMI effect due to the fact that the magnetic penetration depth is higher than their radius. As the frequency increases, the GMI effect becomes important in both the glass-covered wire and the wire after glass removal. Field dependence of the impedance has a similar behaviour to the AGCW ones, when a tensile stress is applied to the wire without glass cover. 展开更多
关键词 giant magneto-impedance amorphous wires frequency
下载PDF
Highly sensitive giant magnetoimpedance in a solenoid containing FeCo-based ribbon
15
作者 方允樟 许启明 +6 位作者 郑金菊 吴锋民 叶慧群 斯剑霄 郑建龙 范晓珍 杨晓红 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第3期423-427,共5页
The highly sensitive giant magneto-impedance effect in a solenoid containing a magnetic core of Fe36Co36Nb4Si4.sB19.2 (FeCo-based) ribbon under a weak magnetic field (WMF) is presented in this paper. The FeCo-base... The highly sensitive giant magneto-impedance effect in a solenoid containing a magnetic core of Fe36Co36Nb4Si4.sB19.2 (FeCo-based) ribbon under a weak magnetic field (WMF) is presented in this paper. The FeCo-based amorphous ribbon is prepared by single roller quenching and annealed with Joule heat in a flowing nitro- gen atmosphere. The giant magnetoimpedance effect in solenoid (GMIES) profiles are measured with an HP4294A impedance analyzer. The result shows that the CMIES responds to the WMF sensitively (as high as 1580 %/A.m-1). The high sensitivity can be obtained in a moderate narrow range of annealing current density (30-34 A/mm2) and closely depends on the driven current frequency. The highest sensitivity (1580 %/A.m-1) is obtained when the FeCo- based amorphous ribbon is annealed at 32 A/mm2 for 10 min and then driven with an alterning current (AC) at the frequency of 350 kHz. The highly sensitive GMIES under the WMF may result from the multiple magnetic-anisotropic structure, which is induced by the temperature gradient produced during Joule-heating the ribbon. 展开更多
关键词 giant magneto-impedance FeCo-based ribbon Joule heat weak magnetic field
下载PDF
磁性MEMS传感器制备技术及生物传感应用研究进展 被引量:2
16
作者 杨真 柳梦雨 +2 位作者 王振宝 黄永 梁晓光 《微纳电子技术》 CAS 北大核心 2023年第2期205-221,共17页
对磁性传感器件的微电子机械系统(MEMS)加工技术以及在生物医学检测方面的应用进行了简单阐述,分析了磁性生物传感技术的工作原理,重点介绍了巨磁阻抗(GMI)、巨磁阻(GMR)和微磁通门传感器的MEMS制备工艺,其中详述了磁性传感器的材料、... 对磁性传感器件的微电子机械系统(MEMS)加工技术以及在生物医学检测方面的应用进行了简单阐述,分析了磁性生物传感技术的工作原理,重点介绍了巨磁阻抗(GMI)、巨磁阻(GMR)和微磁通门传感器的MEMS制备工艺,其中详述了磁性传感器的材料、几何尺寸、结构以及基底对其性能的影响,总结了磁性生物传感器在生物检测中的研究进展,重点阐述了磁性生物传感器在磁性标签、癌症标志物、食源性细菌、病毒以及细胞检测方面的应用。最后,对当前磁性生物传感器在生物医学检测领域面临的问题进行了简要分析,并对磁性生物传感器未来的应用前景进行了展望,以期为研发新一代可用于临床检测磁性生物检测系统打下良好的基础。 展开更多
关键词 微电子机械系统(MEMS) 巨磁阻抗(gmi)传感器 巨磁阻(GMR)传感器 磁通门传感器 生物传感 生物医学检测
下载PDF
Giant magneto-impedance effects in nanocrystalline soft magnetic alloy ribbons 被引量:5
17
作者 Ku, WJ Ge, FD +2 位作者 Yan, G Wang, XY Zhu, J 《Chinese Science Bulletin》 SCIE EI CAS 1997年第12期1049-1052,共4页
SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potentia... SINCE the discovery of the giant magneto-impedance (GMI) effects in amorphous wire (or rib-bon) of CoFeSiB and nanocrystalline wire (or film) of FeCuNbSiB, it has attracted greatattention due to its promising potential applications in industry. Amorphous (and nanocrys-talline) soft magnetic alloys have very large magnetic permeability, when an ac driving currentand an external magnetic field (EMF) are applied, the EMF will damp the magnetic fluxchange caused by the ac driving current, thus the magnetic permeability will decrease; as a re- 展开更多
关键词 giant magneto-impedance effects (gmi) MAGNETIC permeability penetration depth NANOCRYSTALLINE soft MAGNETIC alloy ribbon.
原文传递
Design and Fabrication of Magnetic Sensor Based on Giant Magneto-Impedance Effect 被引量:1
18
作者 Guo Kai, Wang Sansheng, Yang Hui, Chu Xianghua, Xu Yan Beihang University, Beijing 100191, China 《稀有金属材料与工程》 SCIE EI CAS CSCD 北大核心 2011年第S3期315-318,共4页
A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-imp... A large giant magneto-impedance effect was observed in CoFeSiB amorphous ribbon which was treated with the longitudinal field annealing in an atmosphere of Ar for one hour at 10-3 T and 400 ℃. The maximum magneto-impedance ratio is 475% and magnetic sensitivity of about 120%/Oe (1 Oe=80 A/m) at 20MHz, which is helpful to improve the sensitivity of magnetic sensor. The performances of the sensor were carefully studied in open-loop and closed-loop with negative feedback. The full measurement range of the magnetic field detection is 1.7-4 Oe presently, and the sensitivity achieves 176 mV/Oe. The sensor with negative feedback shows excellent linearity and good stability. The designed magnetic sensor can be applied in geomagnetic field measurement. 展开更多
关键词 MAGNETIC SENSOR giant magneto-impedance MAGNETIC field-annealing sensitivity
原文传递
Giant magneto-impedance effect of two paralleled amorphous microwires
19
作者 Shu-Ling Zhang Yue-Sheng Chai +3 位作者 Da-Qing Fang Lu-Cai Wang Da-Wei Xing Jian-Fei Sun 《Rare Metals》 SCIE EI CAS CSCD 2016年第4期344-348,共5页
Giant magneto-impedance (GMI) is effectively enhanced by the mutual magnetic interaction between two amorphous microwires. A comparative study on GMI properties of a single wire and two wires arranged in par- allel ... Giant magneto-impedance (GMI) is effectively enhanced by the mutual magnetic interaction between two amorphous microwires. A comparative study on GMI properties of a single wire and two wires arranged in par- allel mode was reported in this work. Two-peak (TP) of impedance characteristic is presented when the dc external field changed from 0 to 320 A,m-' in two-wire system, which is attributed to successive magnetization process in two wires induced by their magnetic interaction. And the evolution of single peak to TP phenomenon, when the distance between two wires is upto 8 ram, evidences a distance dependence of transformation from successive magnetization to simultaneous via a corresponding dis- tance dependence of magnetostatic interactions. It is pro- posed that the recombination of magnetic interaction and the shielding effect results in a distance dependency of GMI response. When the distance is 8 ram, the magneti- zation process is close to synchronous between two wires, which give rises to higher circular permeability and better GMI response. The impedance ratio AZ/Z increases from 74.5 % of single wire to 172.4 % at 10 MHz. However, when the distance is upto 12 mm, the magnetic interaction is weak and magnetization process is completely independent, and GMI response decreases, relatively. This indicates that the GMI response could be effectively improved in a two-wire connection with an optical distance, which is promising and useful for the application of high-performance GMI sensors. 展开更多
关键词 Amorphous microwire Magnetic interaction giant magneto-impedance MAGNETIZATION
原文传递
巨磁阻抗传感器敏感材料的选择 被引量:10
20
作者 蒋颜玮 房建成 +1 位作者 黄学功 宋玉军 《功能材料》 EI CAS CSCD 北大核心 2009年第1期1-6,共6页
利用巨磁阻抗(GMI)效应来研制传感器,敏感材料的选择非常关键,其GMI性能的好坏直接决定了GMI磁传感器的灵敏度水平。讨论了GMI材料的选择标准,列出了能够产生GMI效应的各种材料,并分析和评述了这些GMI材料的软磁特性、GMI效应及其在传... 利用巨磁阻抗(GMI)效应来研制传感器,敏感材料的选择非常关键,其GMI性能的好坏直接决定了GMI磁传感器的灵敏度水平。讨论了GMI材料的选择标准,列出了能够产生GMI效应的各种材料,并分析和评述了这些GMI材料的软磁特性、GMI效应及其在传感器上的可能应用,提供了设计高性能GMI传感器的候选材料,这些材料以及新型材料的开发为GMI传感器的研制创造了有利的条件,将会促进GMI传感器的发展与应用。 展开更多
关键词 巨磁阻抗(gmi) 敏感材料 磁传感器 gmi比率 磁场灵敏度