An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct curre...An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct current glow discharge mass spectrometry (GD-MS) was established. MnZn ferrite powder was mixed with copper powder, used as a conductor, and pressed. The effects of MnZn ferrite powder preparation conditions and glow discharge parameters for the sensitivity and stability of signal analysis were investigated. By determining the choice of isotope and the application of the mass resolutions of 4000 (MR, medium resolution) and 10000 (HR, high resolution), mass spectral interference was eliminated. The contents of impurity elements in MnZn ferrite powder was calculated by subtraction after normalizing the total signal of Mn, Zn, Fe, O and Cu. The results showed that the detection limit of 26 kinds of impurity elements was between 0.002 and 0.57 μg/g, and the relative standard deviation (RSD) was between 3.33% and 32.35%. The accuracy of this method was verified by the ICP-MS. The method was simple and practical, which is applied to the determination of impurity elements in MnZn ferrite powder.展开更多
A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special as...A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special assembly method, a perfect coaxiality of the two electrodes is obtained. From the gas discharge experiment, it can be seen that the discharge can stably work in normal glow discharge mode. The operating currents of the ion source are in an order of milliamperes and can generate a much larger number and wider variety of reagent ions. The MS experiment shows that the ion source has higher detection sensitivity,展开更多
As a kind of microplasma sustained in air,solution electrode glow discharge(SEGD)ignited between the liquid electrode and metal electrode is attractive to the fields of optical emission spectrometry and mass spectrome...As a kind of microplasma sustained in air,solution electrode glow discharge(SEGD)ignited between the liquid electrode and metal electrode is attractive to the fields of optical emission spectrometry and mass spectrometry due to its unique advantages,such as low power consumption and low carrier gas consumption.Moreover,the complex and efficient reactions in the liquid phase and plasma phase of SEGD make it considerable research potential in the fields of biology and medicine,material synthesis,electrochemistry.Considering the close relationship between the various fields on SEGD,here we are devoted to provide an overview of the development of SEGD in various fields.More importantly,a systematic discussion on the discharge mechanism is conducted based on the research process in various fields for getting deeper insight into the SEGD.展开更多
基金Project(21275162)supported by the National Natural Science Foundation of ChinaProject(KJZH14217)supported by the Achievement Transfer Program of Institutions of Higher Education in Chongqing,ChinaProject(KJ1601224)supported by the Scientific and Technological Research Program of Chongqing Municipal Education Commission,China
文摘An analytical method for the determination of 26 impurity elements (such as Li, Be, Na, Mg, Al, Si, P, S, K, Ca, Sc, Ti, V, Cr, Co, Ni, Ga, Ge, Y, Nb, Mo, Ag, Cd, Sb, W and Pb) in MnZn ferrite powder by direct current glow discharge mass spectrometry (GD-MS) was established. MnZn ferrite powder was mixed with copper powder, used as a conductor, and pressed. The effects of MnZn ferrite powder preparation conditions and glow discharge parameters for the sensitivity and stability of signal analysis were investigated. By determining the choice of isotope and the application of the mass resolutions of 4000 (MR, medium resolution) and 10000 (HR, high resolution), mass spectral interference was eliminated. The contents of impurity elements in MnZn ferrite powder was calculated by subtraction after normalizing the total signal of Mn, Zn, Fe, O and Cu. The results showed that the detection limit of 26 kinds of impurity elements was between 0.002 and 0.57 μg/g, and the relative standard deviation (RSD) was between 3.33% and 32.35%. The accuracy of this method was verified by the ICP-MS. The method was simple and practical, which is applied to the determination of impurity elements in MnZn ferrite powder.
基金supported by the National Natural Science Foundation of China(No.60706030 and No.20827007)the National High Technology Research and Development Plan of China(No.2007AA04Z337)
文摘A novel ambient glow discharge ion source with improved line-cylinder electrodes is put forward and designed in this paper. The diameters of inner and outer electrodes are 0.16 and 4 mm respectively. With a special assembly method, a perfect coaxiality of the two electrodes is obtained. From the gas discharge experiment, it can be seen that the discharge can stably work in normal glow discharge mode. The operating currents of the ion source are in an order of milliamperes and can generate a much larger number and wider variety of reagent ions. The MS experiment shows that the ion source has higher detection sensitivity,
基金supported by the Instrument Development Project of the Chinese Academy of Sciences(No.YZ201539)the National Natural Science Foundation of China(No.21175145)the Shanghai Technical Platform for Testing and Characterization on Inorganic Materials(No.19DZ2290700)。
文摘As a kind of microplasma sustained in air,solution electrode glow discharge(SEGD)ignited between the liquid electrode and metal electrode is attractive to the fields of optical emission spectrometry and mass spectrometry due to its unique advantages,such as low power consumption and low carrier gas consumption.Moreover,the complex and efficient reactions in the liquid phase and plasma phase of SEGD make it considerable research potential in the fields of biology and medicine,material synthesis,electrochemistry.Considering the close relationship between the various fields on SEGD,here we are devoted to provide an overview of the development of SEGD in various fields.More importantly,a systematic discussion on the discharge mechanism is conducted based on the research process in various fields for getting deeper insight into the SEGD.