期刊文献+
共找到535篇文章
< 1 2 27 >
每页显示 20 50 100
Sensitivity Analysis of Computations of the Vapor-Liquid Equilibria of Methane + Methanol or Glycols at Gas Hydrate Formation Conditions
1
作者 Christopher E. Ozigagu Anthony J. Duben 《Modeling and Numerical Simulation of Material Science》 2019年第1期1-15,共15页
The Soave-Redlich-Kwong (SRK-EOS) and Peng-Robinson (PR-EOS) equations of state are used often to describe the behavior of pure substances and mixtures despite difficulties in handling substances, like water, with hig... The Soave-Redlich-Kwong (SRK-EOS) and Peng-Robinson (PR-EOS) equations of state are used often to describe the behavior of pure substances and mixtures despite difficulties in handling substances, like water, with high polarity and hydrogen bonding. They were employed in studying the binary vapor-liquid equilibria (VLE) of methane + methanol, monoethylene glycol (MEG), and triethylene glycol (TEG). These liquids are used to inhibit the formation of gas hydrates. The investigation focused on the conditions at which methane-water clathrates can form 283.89?K to 323.56?K and 5.01?MPa to 18.48?MPa. The pressure of methane in methanol is overestimated by a factor of two by either the SRK-EOS or the PR-EOS. In the methane + MEG system, the predicted pressures for both equations of state are generally less than experimental pressure except for the highest concentration of methane in MEG calculated by the SRK-EOS. In the methane + TEG system, the predictions of both models are close and trend similarly. Because of the comparative lack of extensive experimental methane + TEG data, the similarity of the methane + TEG computed results can be used as a basis for further study of this system experimentally. 展开更多
关键词 VAPOR-LIQUID Equilibrium CUBIC Equations of State CLATHRATE glycols
下载PDF
Poly Ethylene Glycols (PEG) and Micelles as Efficient Catalysts for the Oxidation of Xanthine Derivatives under Conventional and Non-Conventional Conditions
2
作者 Somannagari Shylaja Kola Ramesh +2 位作者 Pochampally Giridhar Reddy Kamatala Chinna Rajanna Pondichery Kuppuswamy Saiprakash 《International Journal of Organic Chemistry》 2011年第4期148-157,共10页
Oxidation of Xanthine alkaloid have been studied with various one and two electron oxidizing agents using PEGs and micelle forming surfactants. The reaction is too sluggish in solution phase, but moderately fast in pr... Oxidation of Xanthine alkaloid have been studied with various one and two electron oxidizing agents using PEGs and micelle forming surfactants. The reaction is too sluggish in solution phase, but moderately fast in presence of PEGs and micelles. However, the reactions are dramatically enhanced under microwave irradiations. Present protocol has several advantages, such as solvent-free conditions, during work-up, fast reaction times, high yields, eco-friendly operational and experimental simplicity, readily available additives as catalysts. 展开更多
关键词 OXIDATION XANTHINE Alkaloids One And Two Electron Oxidizing Agents POLY Ethylene glycols (PEG) Micelle Forming Surfactants Catalysts Microwave Irradiations
下载PDF
Poly Ethylene Glycols as Efficient Media for the Synthesis of <i>β</i>-Nitro Styrenes from <i>α</i>, <i>β</i>-Unsaturated Carboxylic Acids and Metal Nitrates under Conventional and Non-Conventional Conditions
3
作者 Kamatala Chinna Rajanna Kola Ramesh +3 位作者 Soma Ramgopal Somannagari Shylaja Pochampally Giridhar Reddy Pondichery Kuppuswamy Saiprakash 《Green and Sustainable Chemistry》 2011年第4期132-148,共17页
Poly ethylene glycols (PEG-200, 400, 600, 4000 and 6000) supported reactions were conducted with certain α, β-unsaturated acids in presence of metal nitrates under solvent free (solid state) and mineral acid free co... Poly ethylene glycols (PEG-200, 400, 600, 4000 and 6000) supported reactions were conducted with certain α, β-unsaturated acids in presence of metal nitrates under solvent free (solid state) and mineral acid free conditions. The reactants were ground in a mortar with a pestle for about 30 minutes. The aromatic acids underwent nitro decarboxylation and afforded β-nitro styrene derivatives in very good yield while α, β-unsaturated aliphatic carboxylic acids gave corresponding nitro derivatives. Addition of PEG accelerated rate of the reaction enormously. Reaction times substantially decreased from several hours to few minutes followed by highly significant increase in the product yield. Among the several PEGs PEG-300 has been found to be much more effective than other PEGs. 展开更多
关键词 Poly Ethylene glycols (PEG) Rate Accelerations α β-Unsaturated ACIDS Metal Nitrates Solvent Free (Solid State) β-Nitro Styrene Derivatives β-Unsaturated Aliphatic ACIDS NITRO Derivatives
下载PDF
Polyethylene glycols: An effective strategy for limiting liver ischemia reperfusion injury 被引量:3
4
作者 Gianfranco Pasut Arnau Panisello +7 位作者 Emma Folch-Puy Alexandre Lopez Carlos Castro-Benítez Maria Calvo Teresa Carbonell Agustín García-Gil RenéAdam Joan Roselló-Catafau 《World Journal of Gastroenterology》 SCIE CAS 2016年第28期6501-6508,共8页
Liver ischemia-reperfusion injury(IRI) is an inherent feature of liver surgery and liver transplantation in which damage to a hypoxic organ(ischemia) is exacerbated following the return of oxygen delivery(reperfusion)... Liver ischemia-reperfusion injury(IRI) is an inherent feature of liver surgery and liver transplantation in which damage to a hypoxic organ(ischemia) is exacerbated following the return of oxygen delivery(reperfusion). IRI is a major cause of primary nonfunction after transplantation and may lead to graft rejection, regardless of immunological considerations. The immediate response involves the disruption of cellular mitochondrial oxidative phosphorylation and the accumulation of metabolic intermediates during the ischemic period, and oxidative stress during blood flow restoration. Moreover, a complex cascade of inflammatory mediators is generated during reperfusion, contributing to the extension of the damage and finally to organ failure. A variety of pharmacological interventions(antioxidants, anticytokines, etc.) have been proposed to alleviate graft injury but their usefulness is limited by the local and specific action of the drugs and by their potential undesirable toxic effects. Polyethylene glycols(PEGs), which are non-toxic water-soluble compounds approved by the FDA, have been widely used as a vehicle or a base in food, cosmetics and pharmaceuticals, and also as adjuvants for ameliorating drug pharmacokinetics. Some PEGs are also currently used as additives in organ preservation solutions prior to transplantation in order to limit the damage associated with cold ischemia reperfusion. More recently, the administration of PEGs of different molecular weights by intravenous injection has emerged as a new therapeutic tool to protect liver grafts from IRI. In this review, we summarize the current knowledge concerning the use of PEGs as a useful target for limiting liver IRI. 展开更多
关键词 ISCHEMIA REPERFUSION injury Polyethylene GLYCOL LIVER PRECONDITIONING LIVER transplantation UW solut
下载PDF
Vomiting-induced pharyngeal perforation during bowel preparation for colonoscopy:A case report
5
作者 Geonhee Kim Won Hyuk Lee +5 位作者 Seokin Kang Jung Rock Moon Yoon Suk Lee Jun Hyuk Son Nam-Hoon Kim Jong Wook Kim 《World Journal of Clinical Cases》 SCIE 2024年第18期3615-3621,共7页
BACKGROUND Effective bowel cleansing is essential for a successful colonoscopy.Laxatives,such as polyethylene glycol,are commonly used for bowel preparation.Vomiting is a frequent complication during bowel preparation... BACKGROUND Effective bowel cleansing is essential for a successful colonoscopy.Laxatives,such as polyethylene glycol,are commonly used for bowel preparation.Vomiting is a frequent complication during bowel preparation,and forceful vomiting can potentially lead to esophageal perforation,as reported in several previous cases.However,pharyngeal perforation during bowel preparation has not been previously documented.Here,we present a case of pharyngeal perforation induced by forceful vomiting during bowel preparation.CASE SUMMARY A 38-year-old man with a history of hypertension,dyslipidemia,diabetes mellitus,and end-stage renal disease on hemodialysis was admitted for evaluation of recurrent abdominal pain.The patient complained of sudden pain in the neck,throat,and anterior chest following forceful vomiting during bowel preparation.Physical examination revealed crepitus under the skin of the neck and anterior chest on palpation,and upper gastrointestinal endoscopy revealed pharyngeal perforation.The perforation site was located above the upper esophageal sphincter,which distinguished it from Boerhaave’s syndrome.Conservative medical management was chosen after consultation with a thoracic surgeon and an otolaryngologist,considering the patient's mild symptoms,stable vital signs,and the small size of the lesion;the perforation resolved without endoscopic or surgical intervention.The patient was discharged from hospital two weeks after the perforation.CONCLUSION Despite its rarity,pharyngeal perforation should be considered a potential complication of bowel preparation for colonoscopy. 展开更多
关键词 COLONOSCOPY PHARYNX Polyethylene glycols Spontaneous perforation Case report
下载PDF
Reaction pathways and selectivity in the chemo-catalytic conversion of cellulose and its derivatives to ethylene glycol:A review
6
作者 Yao Li Yuchun Zhang +2 位作者 Zhiyu Li Huiyan Zhang Peng Fu 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 2024年第2期310-331,共22页
Biomass-to-ethylene glycol is an effective means to achieve high-value utilisation of cellulose but is hindered by low conversion efficiency and poor catalyst activity and stability.Glucose and cellobiose are derivati... Biomass-to-ethylene glycol is an effective means to achieve high-value utilisation of cellulose but is hindered by low conversion efficiency and poor catalyst activity and stability.Glucose and cellobiose are derivatives of cellulose conversion to ethylene glycol,and it is found that studying the reaction process of both can help to understand the reaction mechanism of cellulose.It is desirable to develop a reusable,highly active catalyst to convert cellulose into ethylene glycol.This ideal catalyst might have one or more active sites described the conversion steps above.Here,we discuss the catalyst development of celluloseto-ethylene glycol,including tungsten,tin,lanthanide,and other transition metal catalysts,and special attention is given to the reaction mechanism and kinetics for preparing ethylene glycol from cellulose,and the economic advantages of biomass-to-ethylene glycol are briefly introduced.The insights given in this review will facilitate further development of efficient catalysts,for addressing the global energy crisis and climate change related to the use of fossil fuels. 展开更多
关键词 Ethylene glycol CELLULOSE Catalyst Retro-aldol condensation HYDROLYSIS Kinetics
下载PDF
Vertically aligned montmorillonite aerogel-encapsulated polyethylene glycol with directional heat transfer paths for efficient solar thermal energy harvesting and storage
7
作者 Qijing Guo Cong Guo +2 位作者 Hao Yi Feifei Jia Shaoxian Song 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2024年第5期907-916,共10页
The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in mon... The conversion and storage of photothermal energy using phase change materials(PCMs)represent an optimal approach for harnessing clean and sustainable solar energy.Herein,we encapsulated polyethylene glycol(PEG)in montmorillonite aerogels(3D-Mt)through vacuum impregnation to prepare 3D-Mt/PEG composite PCMs.When used as a support matrix,3D-Mt can effectively prevent PEG leakage and act as a flame-retardant barrier to reduce the flammability of PEG.Simultaneously,3D-Mt/PEG demonstrates outstanding shape retention,increased thermal energy storage density,and commendable thermal and chemical stability.The phase transition enthalpy of 3D-Mt/PEG can reach 167.53 J/g and remains stable even after 50 heating-cooling cycles.Furthermore,the vertical sheet-like structure of 3D-Mt establishes directional heat transport channels,facilitating efficient phonon transfer.This configuration results in highly anisotropic thermal conductivities that ensure swift thermal responses and efficient heat conduction.This study addresses the shortcomings of PCMs,including the issues of leakage and inadequate flame retardancy.It achieves the development and design of 3D-Mt/PEG with ultrahigh strength,superior flame retardancy,and directional heat transfer.Therefore,this work offers a design strategy for the preparation of high-performance composite PCMs.The 3D-Mt/PEG with vertically aligned and well-ordered array structure developed in this research shows great potential for thermal management and photothermal conversion applications. 展开更多
关键词 montmorillonite aerogel polyethylene glycol phase change materials solar thermal energy storage flame retardant
下载PDF
Polyethylene glycol has immunoprotective effects on sciatic allografts, but behavioral recovery and graft tolerance require neurorrhaphy and axonal fusion
8
作者 Tyler A.Smith Liwen Zhou +6 位作者 Cameron L.Ghergherehchi Michelle Mikesh Cathy Z.Yang Haley O.Tucker JuliAnne Allgood Jared S.Bushman George D.Bittner 《Neural Regeneration Research》 SCIE CAS 2025年第4期1192-1206,共15页
Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripher... Behavioral recovery using(viable)peripheral nerve allografts to repair ablation-type(segmental-loss)peripheral nerve injuries is delayed or poor due to slow and inaccurate axonal regeneration.Furthermore,such peripheral nerve allografts undergo immunological rejection by the host immune system.In contrast,peripheral nerve injuries repaired by polyethylene glycol fusion of peripheral nerve allografts exhibit excellent behavioral recovery within weeks,reduced immune responses,and many axons do not undergo Wallerian degeneration.The relative contribution of neurorrhaphy and polyethylene glycol-fusion of axons versus the effects of polyethylene glycol per se was unknown prior to this study.We hypothesized that polyethylene glycol might have some immune-protective effects,but polyethylene glycol-fusion was necessary to prevent Wallerian degeneration and functional/behavioral recovery.We examined how polyethylene glycol solutions per se affect functional and behavioral recovery and peripheral nerve allograft morphological and immunological responses in the absence of polyethylene glycol-induced axonal fusion.Ablation-type sciatic nerve injuries in outbred Sprague–Dawley rats were repaired according to a modified protocol using the same solutions as polyethylene glycol-fused peripheral nerve allografts,but peripheral nerve allografts were loose-sutured(loose-sutured polyethylene glycol)with an intentional gap of 1–2 mm to prevent fusion by polyethylene glycol of peripheral nerve allograft axons with host axons.Similar to negative control peripheral nerve allografts not treated by polyethylene glycol and in contrast to polyethylene glycol-fused peripheral nerve allografts,animals with loose-sutured polyethylene glycol peripheral nerve allografts exhibited Wallerian degeneration for all axons and myelin degeneration by 7 days postoperatively and did not recover sciatic-mediated behavioral functions by 42 days postoperatively.Other morphological signs of rejection,such as collapsed Schwann cell basal lamina tubes,were absent in polyethylene glycol-fused peripheral nerve allografts but commonly observed in negative control and loose-sutured polyethylene glycol peripheral nerve allografts at 21 days postoperatively.Loose-sutured polyethylene glycol peripheral nerve allografts had more pro-inflammatory and less anti-inflammatory macrophages than negative control peripheral nerve allografts.While T cell counts were similarly high in loose-sutured-polyethylene glycol and negative control peripheral nerve allografts,loose-sutured polyethylene glycol peripheral nerve allografts expressed some cytokines/chemokines important for T cell activation at much lower levels at 14 days postoperatively.MHCI expression was elevated in loose-sutured polyethylene glycol peripheral nerve allografts,but MHCII expression was modestly lower compared to negative control at 21 days postoperatively.We conclude that,while polyethylene glycol per se reduces some immune responses of peripheral nerve allografts,successful polyethylene glycol-fusion repair of some axons is necessary to prevent Wallerian degeneration of those axons and immune rejection of peripheral nerve allografts,and produce recovery of sensory/motor functions and voluntary behaviors.Translation of polyethylene glycol-fusion technologies would produce a paradigm shift from the current clinical practice of waiting days to months to repair ablation peripheral nerve injuries. 展开更多
关键词 allograft rejection AXOTOMY macrophage MYELIN nerve repair polyethylene glycol(PEG) sciatic nerve T cell transplantation Wallerian degeneration
下载PDF
Catalytic Effect of Transition Metal Complexes of Triaminoguanidine on the Thermolysis of Energetic NC/DEGDN Composite
9
作者 Mohammed Dourari Ahmed Fouzi Tarchoun +4 位作者 Djalal Trache Amir Abdelaziz Roufaida Tiliouine Tessnim Barkat Weiqiang Pang 《火炸药学报》 EI CAS CSCD 北大核心 2024年第3期209-219,I0003,共12页
The transition metal complexes of triaminoguanidine(TAG-M,where M=Cobalt(Co)or Iron(Fe))have been prepared.The catalytic effect of these complexes on the thermolysis of energetic composite based on nitrocellulose and ... The transition metal complexes of triaminoguanidine(TAG-M,where M=Cobalt(Co)or Iron(Fe))have been prepared.The catalytic effect of these complexes on the thermolysis of energetic composite based on nitrocellulose and diethylene glycol dinitrate,has been investigated.Extensive characterization of the resulting energetic composites was carried out using scanning electron microscopy(SEM),X-ray diffraction(XRD),Fourier transform infrared spectroscopy(FTIR),and differential scanning calorimetry(DSC).Isoconversional kinetic analysis was performed to determine the Arrhenius parameters associated with the thermolysis of the elaborated energetic formulations.It is found that TAG-M complexes have strong catalytic effect on the thermo-kinetic decomposition of NC/DEGDN by decreasing the apparent activation energy and significantly increased the total heat release.The models that govern the decomposition processes are also studied,and it is revealed that different reaction processes are accomplished by introduction metal complexes of triaminoguanidine.Overall,this study serves as a valuable reference for future research focused on the investigation of catalytic combustion features of solid propellants. 展开更多
关键词 triaminoguanidine transition metal complexes NITROCELLULOSE diethylene glycol dinitrate catalytic effect
下载PDF
Hepatitis B cure:Current situation and prospects
10
作者 Ya-Ping Li Chen-Rui Liu +1 位作者 Ling He Shuang-Suo Dang 《World Journal of Hepatology》 2024年第6期900-911,共12页
Achievement of a‘clinical cure’in chronic hepatitis B(CHB)implies sustained virological suppression and immunological control over the infection,which is the ideal treatment goal according to domestic and internatio... Achievement of a‘clinical cure’in chronic hepatitis B(CHB)implies sustained virological suppression and immunological control over the infection,which is the ideal treatment goal according to domestic and international CHB management guidelines.Clinical practice has shown encouraging results for specific patient cohorts using tailored treatment regimens.These regimens incorporate either nucleos(t)ide analogs,immunomodulatory agents such as pegylated interferonα,or a strategic combination of both,sequentially or concurrently administered.Despite these advancements in the clinical handling of hepatitis B,achieving a clinical cure remains elusive for a considerable subset of patients due to the number of challenges that preclude the realization of optimal treatment outcomes.These include,but are not limited to,the emergence of antiviral resistance,incomplete immune recovery,and the persistence of covalently closed circular DNA.Moreover,the variance in response to interferon therapy and the lack of definitive biomarkers for treatment cessation also contribute to the complexity of achieving a clinical cure.This article briefly overviews the current research progress and existing issues in pursuing a clinical cure for hepatitis B. 展开更多
关键词 Chronic hepatitis B Clinical cure Polyethylene glycol interferon Treatment strategies Research progress
下载PDF
Constipation and colonoscopy
11
作者 Dusan Dj Popovic Branka Filipovic 《World Journal of Gastrointestinal Endoscopy》 2024年第5期244-249,共6页
Constipation is a significant sociomedical problem,which can be caused by various reasons.In the diagnostic approach to patients with constipation,the following data are usually sufficient:History,complete physical ex... Constipation is a significant sociomedical problem,which can be caused by various reasons.In the diagnostic approach to patients with constipation,the following data are usually sufficient:History,complete physical examination(including rectal examination),and additional diagnostic tests.A colonoscopy is not a necessary diagnostic method for all patients with constipation.However,if patients have alarm symptoms/signs,that suggest an organic reason for constipation,a colonoscopy is necessary.The most important alarm symptoms/signs are age>50 years,gastrointestinal bleeding,new-onset constipation,a palpable mass in the abdomen and rectum,weight loss,anemia,inflammatory bowel disease,and family history positive for colorectal cancer.Most endoscopists do not like to deal with patients with constipation.There are two reasons for this,namely the difficulty of endoscopy and the adequacy of preparation.Both are adversely affected by constipation.To improve the quality of colonoscopy in these patients,good examination techniques and often more extensive preparation are necessary.Good colonoscopy technique implies adequate psychological preparation of the patient,careful insertion of the endoscope with minimal insufflation,and early detection and resolution of loops.Bowel preparation for colonoscopy often requires prolonged preparation and sometimes the addition of other laxatives. 展开更多
关键词 CONSTIPATION Functional constipation COLONOSCOPY Bowel preparation Polyethylene glycol
下载PDF
Implementation of a New Solution for the Preservation of Anatomical Specimens Made of Non-Toxic Substances
12
作者 Ma Reyes Pichardo-Molinero Samantha Jardon-Xicotencatl +1 位作者 Misael R. Oliver-González Carlos G. García-Tovar 《Open Journal of Veterinary Medicine》 CAS 2024年第3期56-67,共12页
The preservation of anatomical pieces in Veterinary Anatomy is essential since it is not possible to dissect all domestic species. Most techniques use reagents with high levels of toxicity such as formaldehyde. The ob... The preservation of anatomical pieces in Veterinary Anatomy is essential since it is not possible to dissect all domestic species. Most techniques use reagents with high levels of toxicity such as formaldehyde. The objective of this work was to develop a new preservation technique that uses reagents with zero toxicity and that allows obtaining preserved pieces suitable for anatomical studies. The alcohol propylene glycol technique was developed, the method of which uses a fixation step with alcohol, sodium chloride, commercial vinegar and subsequently the impregnation of the preservation solution made from propylene glycol and commercial vinegar, which are non-toxic. As a result of this work, adequately preserved sheep hearts were obtained that preserved their morphology with slight changes in size and weight, which did not affect their external and internal anatomical structure. Its coloration was not substantially affected, remaining a little lighter. The pieces obtained showed flexibility which allowed dissections to be carried out. The time to develop the technique was 20 days. A comparative study was carried out with the phenolated glycerin technique that uses toxic reagents (formaldehyde and phenol) and the pieces obtained with the alcohol propylene glycol technique were of better quality, observing that the pieces with phenolated glycerin tend to darken and are more rigid. And the time to develop the technique is 24 days. In conclusion, a preservation technique for anatomical pieces was developed that allowed the preservation of the organs under study, which allow their use for anatomical studies, and which have been preserved without changes until the time of this publication (8 months) and there are pieces preserved with this technique for 2 years. 展开更多
关键词 Veterinary Anatomy Heart Preservation Techniques Alcohol Propylene Glycol Technique FIXATION NECROPSY Toxic Chemicals
下载PDF
Research Progress of Bowel Preparation for Colonoscopy
13
作者 Yongquan Huang Xiaoping Tan 《Journal of Biosciences and Medicines》 2024年第5期10-18,共9页
Colorectal cancer ranks third in the global cancer data in 2020. Colorectal scope is the most effective method to diagnose colorectal diseases such as benign and malignant colorectal tumors. The poor quality of intest... Colorectal cancer ranks third in the global cancer data in 2020. Colorectal scope is the most effective method to diagnose colorectal diseases such as benign and malignant colorectal tumors. The poor quality of intestinal preparation causes an increased rate of missed diagnosis of colorectal tumors, reduces the rate of cecal intubation for colorectal examination, increases the discomfort, and reduces the compliance of re-examination. Therefore, we should try our best to improve the quality of intestinal preparation. This study reviewed the latest advances related to the preoperative preparation for colonoscopy. Recent research shows that smartphone apps can provide more detailed education and guidance on bowel preparation;Pre-packaged foods are more suitable as a way to eat before colonoscopy. The use of smaller doses, better taste of cathartic agents, and some auxiliary measures, combined with the patient’s situation to provide personalized intestinal preparation measures to improve the quality of intestinal preparation. Starting from the quality of colonoscopy bowel preparation, continuous improvement of patients’ tolerance to bowel preparation, continuous improvement of bowel preparation plan based on individual factors’ needs, and better communication with examined subjects by using existing scientific information technology, may be the hot spot of colonoscopy bowel preparation research in the next few years. 展开更多
关键词 COLONOSCOPY Bowel Preparation Preoperative Education Quality of Bowel Preparation Polyethylene Glycol
下载PDF
Fabrication of New Transparent and Hydrophilic Hybrid Anti-fog Coating from Silane Coupler Modified by Polyethylene Glycols 被引量:1
14
作者 JIANG Yuhang LI Yao +3 位作者 WANG Xuesong PIAO Linglan SHI Zuosen CUI Zhanchen 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2017年第1期150-154,共5页
A new and effective organic-inorganic hybrid hydrophilic anti-fog coating was proposed and prepared. As is well-known, the presence of an inorganic component typically decreases the hydrophilicity and transparency of ... A new and effective organic-inorganic hybrid hydrophilic anti-fog coating was proposed and prepared. As is well-known, the presence of an inorganic component typically decreases the hydrophilicity and transparency of the coating. To solve this problem, we used polyethylene glycol with two different molecular weights to modify the si- lane coupling agent and mixed it with hydrophilic copolymer to form coating formulas. We coated these formulas on polycarbonate(PC) substrates to measure the anti-fogging properties via contact angle and anti-fogging tests, com- pared their transparency properties using UV-Vis spectra and evaluated the hardness using a pencil hardness tester. The results demonstrate that the molecular weight of PEG has a strong influence on the properties of the anti-fog coatings. After the corresponding optimization, we manufactured an excellent anti-fog coating. In addition to good adhesion and hardness, the coating also exhibited excellent mechanical properties, optical transparency and perfect anti-fogging performance. 展开更多
关键词 HYDROPHILIC Anti-fog HYBRID Polyethylene glycol
原文传递
Research Progress of Bowel Preparation for Colonoscopy
15
作者 Yongquan Huang Xiaoping Tan 《Journal of Biosciences and Medicines》 2024年第5期10-18,共9页
Colorectal cancer ranks third in the global cancer data in 2020.Colorectal scope is the most effective method to diagnose colorectal diseases such as benign and malignant colorectal tumors.The poor quality of intestin... Colorectal cancer ranks third in the global cancer data in 2020.Colorectal scope is the most effective method to diagnose colorectal diseases such as benign and malignant colorectal tumors.The poor quality of intestinal preparation causes an increased rate of missed diagnosis of colorectal tumors,reduces the rate of cecal intubation for colorectal examination,increases the discomfort,and reduces the compliance of re-examination.Therefore,we should try our best to improve the quality of intestinal preparation.This study reviewed the latest advances related to the preoperative preparation for colonoscopy.Recent research shows that smartphone apps can provide more detailed education and guidance on bowel preparation;Pre-packaged foods are more suitable as a way to eat before colonoscopy.The use of smaller doses,better taste of cathartic agents,and some auxiliary measures,combined with the patient’s situation to provide personalized intestinal preparation measures to improve the quality of intestinal preparation.Starting from the quality of colonoscopy bowel preparation,continuous improvement of patients’tolerance to bowel preparation,continuous improvement of bowel preparation plan based on individual factors’needs,and better communication with examined subjects by using existing scientific information technology,may be the hot spot of colonoscopy bowel preparation research in the next few years. 展开更多
关键词 Colonoscopy Bowel Preparation Preoperative Education Quality of Bowel Preparation Polyethylene Glycol
下载PDF
Factors affecting the quality of bowel preparation for colonoscopy in hard-to-prepare patients:Evidence from the literature 被引量:1
16
作者 Endrit Shahini Emanuele Sinagra +4 位作者 Alessandro Vitello Rocco Ranaldo Antonella Contaldo Antonio Facciorusso Marcello Maida 《World Journal of Gastroenterology》 SCIE CAS 2023年第11期1685-1707,共23页
Adequate bowel cleansing is critical for a high-quality colonoscopy because it affects diagnostic accuracy and adenoma detection.Nevertheless,almost a quarter of procedures are still carried out with suboptimal prepar... Adequate bowel cleansing is critical for a high-quality colonoscopy because it affects diagnostic accuracy and adenoma detection.Nevertheless,almost a quarter of procedures are still carried out with suboptimal preparation,resulting in longer procedure times,higher risk of complications,and higher likelihood of missing lesions.Current guidelines recommend high-volume or low-volume polyethylene glycol(PEG)/non-PEG-based split-dose regimens.In patients who have had insufficient bowel cleansing,the colonoscopy should be repeated the same day or the next day with additional bowel cleansing as a salvage option.A strategy that includes a prolonged low-fiber diet,a split preparation regimen,and a colonoscopy within 5 h of the end of preparation may increase cleansing success rates in the elderly.Furthermore,even though no specific product is specifically recommended in the other cases for difficult-to-prepare patients,clinical evidence suggests that 1-L PEG plus ascorbic acid preparation are associated with higher cleansing success in hospitalized and inflammatory bowel disease patients.Patients with severe renal insufficiency(creatinine clearance<30 mL/min)should be prepared with isotonic high volume PEG solutions.Few data on cirrhotic patients are currently available,and no trials have been conducted in this population.An accurate characterization of procedural and patient variables may lead to a more personalized approach to bowel preparation,especially in patients undergoing resection of left colon lesions,where intestinal preparation has a poor outcome.The purpose of this review was to summarize the evidence on the risk factors influencing the quality of bowel cleansing in difficult-to-prepare patients,as well as strategies to improve colonoscopy preparation in these patients. 展开更多
关键词 Colorectal cancer COLONOSCOPY Adenoma detection rate Bowel preparation Polyethylene glycol
下载PDF
Hyponatremic encephalopathy due to polyethylene glycol-based bowel preparation for colonoscopy:A case report 被引量:1
17
作者 Yuan Zhao Hai-Sheng Dong 《World Journal of Clinical Cases》 SCIE 2023年第1期187-192,共6页
BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause ... BACKGROUND Adequate bowel preparation is critical for colonoscopy screening.At present,the most widely used intestinal cleaner recommended at home and abroad is Polyethylene glycol(PEG).Intestinal cleansers can cause electrolyte disturbances and hyponatremia.However,hyponatremic encephalopathy due to hyponatremia induced by PEG solution,although rare,can lead to serious irreversible sequelae and even death.CASE SUMMARY In this report,we discuss a case of neurological dysfunction due to hyponatremia,also known as hyponatremic encephalopathy,observed in a 63-year-old woman who underwent PEG-based bowel preparation for colonoscopy.She was eventually transferred to our intensive care unit for treatment due to her Glasgow Coma Scale score of 9/15(Eye opening 2;Verbal response 1;Motor response 6)and abnormal laboratory tests.CONCLUSION Physicians should be thoroughly familiarized with the patient’s history before prescribing PEG for bowel preparation,and timely identification of patients with hyponatremic encephalopathy is essential as delayed treatment is associated with poor neurological outcomes.An intravenous infusion of 3%sodium chloride is recommended at the onset of early symptoms.The goal of treatment is to adequately treat cerebral edema while avoiding serum sodium correction beyond 15 to 20 m Eq/L within 48 h of treatment to prevent osmotic demyelination syndrome. 展开更多
关键词 Polyethylene glycol Intestinal preparation Hyponatremic encephalopathy HYPONATREMIA BRAIN Case report
下载PDF
Emerging space for non-polyethene-glycol bowel preparations in inflammatory bowel disease-related colonoscopy:Veering toward better adherence and palatability 被引量:1
18
作者 Raffaele Pellegrino Antonietta Gerarda Gravina 《World Journal of Gastroenterology》 SCIE CAS 2023年第46期6022-6027,共6页
Patients with inflammatory bowel diseases(IBDs)require repeated endoscopic evaluations over time by colonoscopy to weigh disease activity but also for different and additional indications(e.g.,evaluation of postoperat... Patients with inflammatory bowel diseases(IBDs)require repeated endoscopic evaluations over time by colonoscopy to weigh disease activity but also for different and additional indications(e.g.,evaluation of postoperative recurrence,colorectal cancer surveillance).Colonoscopy,however,requires adequate bowel preparation to be of quality.The latter is achieved as long as the patient takes a certain amount of product to have a number of bowel movements suitable to clean the colon and allow optimal visualization of the mucosa during endoscopy.However,significant guidelines recommend preparations for patients with IBD not excelling in palatability.This recommendation originates from the fact that most of the studies conducted on bowel preparations in patients with IBD have been done with isosmolar preparations based on polyethylene glycol(PEG),for which,therefore,more safety data exist.As a result,the low-volume non-PEG preparations(e.g.,magnesium citrate plus picosulphate,oral sulphate solutions)have been set aside for the whole range of warnings to be heeded because of their hyperosmolarity.New studies,however,are emerging,leaning in overall for a paradigm shift in this matter.Indeed,such non-PEG preparations seem to show a particularly encouraging and engaging safety profile when considering their broad potential for tolerability and patient preference.Indeed,such evidence is insufficient to indicate such preparations in all patients with IBD but may pave the way for those with remission or well-controlled disease.This article summarizes the central studies conducted in IBD settings using non-PEG preparations by discussing their results. 展开更多
关键词 Inflammatory bowel disease Crohn’s disease Ulcerative colitis Bowel preparation COLONOSCOPY Polyethylene glycol Low-volume
下载PDF
Analysis of Ethylene Glycol Degumming Process and Characterization of Hemp Fibers 被引量:1
19
作者 池虹 秦智慧 +3 位作者 赵树元 刘柳 张瑞云 程隆棣 《Journal of Donghua University(English Edition)》 CAS 2023年第3期255-260,共6页
To overcome the shortcomings of traditional degumming process,an efficient and environmentally friendly ethylene glycol(EG) degumming process was adopted to degum hemp fibers.The surface morphology,chemical compositio... To overcome the shortcomings of traditional degumming process,an efficient and environmentally friendly ethylene glycol(EG) degumming process was adopted to degum hemp fibers.The surface morphology,chemical composition,chemical structures,and mechanical properties of the fiber samples were analyzed to explore the mechanism of the degumming process.It was found that the EG degumming process could be divided into the main degumming stage(heating) and the supplementary degumming stage(insulation).The removal rates of hemicellulose and lignin in the main degumming stage were 70.56% and 60.17%,respectively.In the supplementary degumming stage,9.95% hemicellulose and 25.39% lignin were removed.It is confirmed that EG can separate hemp fibers effectively with less damage,which holds great potential for the biomass fiber separation technology. 展开更多
关键词 hemp fiber degumming process ethylene glycol(EG) HEMICELLULOSE LIGNIN
下载PDF
High-Performance Quasi-Solid-State Pouch Cells Enabled by in situ Solidification of a Novel Polymer Electrolyte 被引量:1
20
作者 Qingwen Lu Changhong Wang +9 位作者 Danni Bao Hui Duan Feipeng Zhao Kieran Doyle-Davis Qiang Zhang Rennian Wang Shangqian Zhao Jiantao Wang Huan Huang Xueliang Sun 《Energy & Environmental Materials》 SCIE EI CAS CSCD 2023年第4期15-21,共7页
Conventional lithium-ion batteries(LIBs)with liquid electrolytes are challenged by their big safety concerns,particularly used in electric vehicles.All-solid-state batteries using solid-state electrolytes have been pr... Conventional lithium-ion batteries(LIBs)with liquid electrolytes are challenged by their big safety concerns,particularly used in electric vehicles.All-solid-state batteries using solid-state electrolytes have been proposed to significantly improve safety yet are impeded by poor interfacial solid–solid contact and fast interface degradation.As a compromising strategy,in situ solidification has been proposed in recent years to fabricate quasi-solid-state batteries,which have great advantages in constructing intimate interfaces and cost-effective mass manufacturing.In this work,quasi-solid-state pouch cells with high loading electrodes(≥3 m Ah cm^(-2))were fabricated via in situ solidification of poly(ethylene glycol)diacrylate-based polymer electrolytes(PEGDA-PEs).Both single-layer and multilayer quasi-solid-state pouch cells(2.0 Ah)have demonstrated stable electrochemical performance over500 cycles.The superb electrochemical stability is closely related to the formation of robust and compatible interphase,which successfully inhibits interfacial side reactions and prevents interfacial structural degradation.This work demonstrates that in situ solidification is a facile and cost-effective approach to fabricate quasi-solid-state pouch cells with both excellent electrochemical performance and safety. 展开更多
关键词 high areal capacity high-energy-density pouch cells in situ solidification poly(ethylene glycol)diacrylate-based polymer electrolyte
下载PDF
上一页 1 2 27 下一页 到第
使用帮助 返回顶部