Gradient-index rod lens (GRIN-lens) whose pitch is ordinary value with bevel ferrule coupling system is analyzed, an equivalent method which can be used to analyze this system is put forward, and a general formula for...Gradient-index rod lens (GRIN-lens) whose pitch is ordinary value with bevel ferrule coupling system is analyzed, an equivalent method which can be used to analyze this system is put forward, and a general formula for determining the coupling loss with axes mismatch, radial mismatch, and angular mismatch is derived by use of the Gaussian field approximation and mode-field coupling theory. The experimental results are in good agreement with the theory prediction. It indicates that these formulas are suitable to analyze the gradient-index rod lens coupling system with pigtail fiber.展开更多
In order to verify the properties of the light propagating through a gradient-index (GRIN) fibre probe for optical coherence tomography (OCT), numerical simulation using the optical software GLAD is carried out. F...In order to verify the properties of the light propagating through a gradient-index (GRIN) fibre probe for optical coherence tomography (OCT), numerical simulation using the optical software GLAD is carried out. Firstly, the model of the GRIN fibre probe is presented, which is consisted of a single mode fibre (SMF), a no-core fibre (NCF), a GRIN fibre lens and an air path. Then, the software GLAD is adopted to numerically investigate how the lengths of the NCF and the GRIN fibre lens influence the performance of the Gaussian beam focusing through the GRIN fibre probe. The simulation results are well consistent with the experimental ones, showing that the GLAD based numerical simulation technique is an intuitive and effective tool for the verification of the properties of the light propagation. In this paper, we find that on the conditions of a constant GRIN fibre lens length of 0.1 mm and an NCF length of 0.36 mm, the working distance of the probe will be 0.75 mm and the focus spot size is 32 μm.展开更多
An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical c...An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.展开更多
Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- ...Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- expanding effect of no-core fiber (NCF) and the focusing properties of the GRIN fiber lens were analyzed based on the model of GRIN fiber probe consisting of single-mode fiber (SMF), NCF and GRIN fiber lens. A stereo micro- scope based system was developed to fabricate the GRIN fiber probe. A fiber fusion splicer and an ultrasonic cleaver were used to weld and cut the fiber respectively. A con- focal microscopy was used to measure the dimensions of probe components. The results show that the sizes of probe components developed are at the level of millimeter. Therefore, the proposed experimental system meets the fabrication requirements of an ultra-small self-focusing GRIN fiber probe. This shows that this fabrication device and method can be employed in the fabrication of ultra- small self-focusing GRIN fiber probe and applied in the study of miniaturized optical probes and OCT systems.展开更多
文摘Gradient-index rod lens (GRIN-lens) whose pitch is ordinary value with bevel ferrule coupling system is analyzed, an equivalent method which can be used to analyze this system is put forward, and a general formula for determining the coupling loss with axes mismatch, radial mismatch, and angular mismatch is derived by use of the Gaussian field approximation and mode-field coupling theory. The experimental results are in good agreement with the theory prediction. It indicates that these formulas are suitable to analyze the gradient-index rod lens coupling system with pigtail fiber.
基金supported by the International Cooperation Project of Shanghai Science and Technology Committee,China(Grant No.09530708700)
文摘In order to verify the properties of the light propagating through a gradient-index (GRIN) fibre probe for optical coherence tomography (OCT), numerical simulation using the optical software GLAD is carried out. Firstly, the model of the GRIN fibre probe is presented, which is consisted of a single mode fibre (SMF), a no-core fibre (NCF), a GRIN fibre lens and an air path. Then, the software GLAD is adopted to numerically investigate how the lengths of the NCF and the GRIN fibre lens influence the performance of the Gaussian beam focusing through the GRIN fibre probe. The simulation results are well consistent with the experimental ones, showing that the GLAD based numerical simulation technique is an intuitive and effective tool for the verification of the properties of the light propagation. In this paper, we find that on the conditions of a constant GRIN fibre lens length of 0.1 mm and an NCF length of 0.36 mm, the working distance of the probe will be 0.75 mm and the focus spot size is 32 μm.
基金supported by the World Class University Program funded by the Ministry of Education, Science, and Technology through the National Research Foundation of Korea (No. R31-10008)supported in part by NIH (No. BRP 1R01 EB 007969- 01)
文摘An integrated microball lens fiber catheter probe is demonstrated, which has better lateral resolution and longer working distance than a corresponding bare fiber probe with diverging beam for Fourier domain optical coherence tomography (FDOCT). Simulation results are shown to gain the effect of the distance between the mieroball lens and the bare fiber to the focusing plane and beam width. The freedom of modifying the working distance and lateral resolution is shown. This is achieved by changing the gap distance between the single-mode fiber and the microball lens within the packaged surgical needle catheter without using an additional beam expander having a fixed length. The probe successfully acquired crosssectional images of ocular tissues from an animal sample with the proposed miniaturized imaging probe.
基金supported by the National Natural Science Foundation of China(Grant No.41104065)the Dawn Planning Foundation of Shanghai Municipal Education Commission (Grant No.12CG047)by the Scientific Research Innovation Project of Shanghai Municipal Education Commission(Grant No. 13YZ022)
文摘Fabrication method and device of ultra-small gradient-index (GRIN) fiber probe were investigated in order to explore the development of ultra-small probes for optical coherence tomography (OCT) imaging. The beam- expanding effect of no-core fiber (NCF) and the focusing properties of the GRIN fiber lens were analyzed based on the model of GRIN fiber probe consisting of single-mode fiber (SMF), NCF and GRIN fiber lens. A stereo micro- scope based system was developed to fabricate the GRIN fiber probe. A fiber fusion splicer and an ultrasonic cleaver were used to weld and cut the fiber respectively. A con- focal microscopy was used to measure the dimensions of probe components. The results show that the sizes of probe components developed are at the level of millimeter. Therefore, the proposed experimental system meets the fabrication requirements of an ultra-small self-focusing GRIN fiber probe. This shows that this fabrication device and method can be employed in the fabrication of ultra- small self-focusing GRIN fiber probe and applied in the study of miniaturized optical probes and OCT systems.