期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
Lateral femoral tunnel preparation and graft fixation for anterior cruciate ligament reconstruction–A discussion
1
作者 Mehak Chandanani Andrea Volpin 《World Journal of Clinical Cases》 SCIE 2024年第17期3277-3280,共4页
This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft ... This article provides a discussion and commentary around the recent advances in arthroscopic anterior cruciate ligament reconstruction(ACLR),with a focus on the aspects of lateral femoral tunnel preparation and graft fixation techniques.The paper explores and comments on a recently published review by Dai et al,titled"Research progress on preparation of lateral femoral tunnel and graft fixation in ACLR",while providing insight into its relevance within the field of ACLR,and recommendations for future research. 展开更多
关键词 Anterior cruciate ligament reconstruction Arthroscopic surgery Lateral femoral tunnel Graft fixation techniques Anterior cruciate ligament tear BIOMECHANICS Knee injuries
下载PDF
Tunable wavelength filters using polymer long-period waveguide gratings based on metal-cladding directly defined technique
2
作者 王继厚 陈长鸣 +5 位作者 郑洋 王希斌 衣云骥 孙小强 王菲 张大明 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第2期268-273,共6页
In this work, long-period waveguide grating-based tunable wavelength filters using organic–inorganic grafting poly(methyl methacrylate)(PMMA) materials are designed and fabricated by metal-cladding directly defin... In this work, long-period waveguide grating-based tunable wavelength filters using organic–inorganic grafting poly(methyl methacrylate)(PMMA) materials are designed and fabricated by metal-cladding directly defined technique.The thermal stabilities and optical properties of the organic–inorganic grafting PMMA core materials are analyzed. Structures and performance parameters of the waveguide gratings and self-electrode heaters are designed and simulated. The contrast of the filter is about 15 d B and the resonant wavelength can be tuned by different electric powers applied to the metal-cladding self-electrode heaters. The temperature sensitivity is 3.5 nm/℃ and the switching time is about 1 ms. The technique is very suitable for realizing the optoelectronic integrated wavelength-division-multiplexing systems. 展开更多
关键词 organic–inorganic grafting materials polymer optical waveguide long-period grating filter metalcladding defined technique
下载PDF
Outflow reconstruction with arterial patch in domino liver transplantation: a new technical option 被引量:1
3
作者 Laura Lladó Emilio Ramos +1 位作者 Sofia De LaSerna Joan Fabregat 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2014年第5期551-554,共4页
Domino liver transplantation(LT), using livers from familial amyloidotic polyneuropathy(FAP) patients, is a well described technique useful to expand donor pool. One of the main difficulties of this type of LT ari... Domino liver transplantation(LT), using livers from familial amyloidotic polyneuropathy(FAP) patients, is a well described technique useful to expand donor pool. One of the main difficulties of this type of LT arises from the necessity to share the vascular pedicles between the graft and the donor. The most important challenge resides in restoring a proper hepatic venous outflow in the FAP-liver recipient.This is specially challenging when using the piggy-back technique, because the hepatic stumps may be too short. To overcome this issue, surgeons explored several techniques using different types of venous grafts. We describe a new technical option by using an arterial graft from the deceased donor. By using both iliac arteries a long graft is created and sutured as needed to the hepatic vein stump. We describe herein this new technique employed in a domino liver recipient who underwent retransplantation for ischemic cholangitis. The procedure was performed using the piggy-back technique; the venous stump of the FAP liver was reconstructed with the arterial graft. The patient had uneventful postoperative and mid-term hepatic function, and anastomosis was patent 24 months after LT. 展开更多
关键词 liver transplantation technique graft hepatic vein iliac artery
下载PDF
A Procedure of Combination of Sequential Internal Thoracic Artery Grafting and Cooley's Technique for Complicated Case With Multi-vessel Disease,Left Ventricular Aneurysm and Mitral Regurgitation
4
作者 梁孟亚 陈光献 +1 位作者 吴钟凯 张希 《South China Journal of Cardiology》 CAS 2009年第3期159-163,共5页
INTRODUCTIONLeft ventricular aneurysm and ischemic mitral regurgitation are two of most common complications of acute myocardial infarction (AMI). Combination of both these two fatal complications is not rare and th... INTRODUCTIONLeft ventricular aneurysm and ischemic mitral regurgitation are two of most common complications of acute myocardial infarction (AMI). Combination of both these two fatal complications is not rare and the management of these complicated cases is always a challenge to cardiac surgeon because of its relatively high mortality. We reported a rare case of AMI in which a singlestage correction of mitral valve replacement with preservation of mitral apparatus, sequential left internal thoracic artery (ITA) grafting and Cooley's technique. 展开更多
关键词 LAD A Procedure of Combination of Sequential Internal Thoracic Artery grafting and Cooley’s technique for Complicated Case With Multi-vessel Disease Left Ventricular Aneurysm and Mitral Regurgitation
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部