Objective Antiretroviral drugs covered by medical insurance have been gradually used by people living with human immunodeficiency virus(PLWH)in recent years in China.This study aimed to analyze their willingness to pa...Objective Antiretroviral drugs covered by medical insurance have been gradually used by people living with human immunodeficiency virus(PLWH)in recent years in China.This study aimed to analyze their willingness to pay(WTP)for antiretroviral drugs.Methods A mixed-methods study design involving a cross-sectional survey and in-depth interviews was conducted.A cross-sectional survey was performed to collect data on the general characteristics,economic status,antiretroviral therapy(ART)status,and WTP of PLWH in 18 Chinese cities from August 2022 to February 2023.Multivariate logistic regression was used to analyze the factors associated with WTP.Representatives of PLWH were interviewed via in-depth interviews,and the data were thematically analyzed.Results Among the 941 PLWH,271(28.80%)were willing to pay for antiretroviral drugs covered by medical insurance.For basic medical insurance for urban and rural residents,PLWH with the following characteristics were more willing to pay:an educational level of senior high school or technical secondary school,having an undergraduate degree or higher,frequently working away from their hometowns,and homosexual transmission.Off-farm workers and recipients of government medical aid were more unwilling to pay.For basic medical insurance for urban employees,PLWH with the following characteristics were more willing to pay:frequently working away from their hometowns;homosexual transmission;personal annual income≥100,000 CNY;and adverse events of antiretroviral drugs.The main reasons for PLWH’s WTP for antiretroviral drugs covered by medical insurance were that the drugs had fewer adverse events and were easier to administer.The main reasons for PLWH’s unwillingness to pay were financial difficulties and privacy concerns.Conclusion Nearly one-third of PLWH are willing to pay for antiretroviral drugs covered by medical insurance.In the future,PLWH with a high WTP can be guided to use these drugs.展开更多
AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks...AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks (n=5) from July 2007 to February 2012 that had received placement of fully covered self-expanding metal stents (FCSEMs). Fourteen patients had endoscopic placement of VIABIL (Conmed, Utica, New York, United States) stents and three had Wallflex (Boston Scientific, Mass) stents. FCSEMS were 8 mm or 10 mm in diameter and 4 cm to 10 cm in length. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. FCSEMS were removed after 4 or more weeks. Resolution of BBS and leak was documented cholangiographically following stent removal. Stent patency can be defined as adequate bile and contrast flow from the stent and into the ampulla during endoscopic retrograde cholangiopancreatography (ERCP) without clinical signs and/or symptoms of biliary obstruction. Criterion for bile leak resolution at ERCP is defined as absence of contrast extravasation from the common bile duct, cystic duct remanent, or gall blad-der fossa. Rate of complications such as migration, and instent occlusion were recorded. Failure of endoscopic therapy was defined as persistent biliary stenosis or continuous biliary leakage after 12 mo of stent placement. RESULTS: All 17 patients underwent successful FC- SEMS placement and removal. Etiologies of BBS included: cholecystectomies (n=8), cholelithiasis (n=2), hepatic artery compression (n=1), pancreatitis (n=2), and Whipple procedure (n=1). All bile leaks occurred following cholecystectomy. The anatomic location of BBS varied: distal common bile duct (n=7), common hepatic duct (n=1), hepaticojejunal anastomosis (n=2), right intrahepatic duct (n=1), and choledochoduo-denal anastomatic junction (n=1). All bile leaks were found to be at the cystic duct. Twelve of 17 patients had failed prior stent placement or exchange. Resolution of the biliary strictures and bile leaks was achieved in 16 of 17 patients (94%). The overall median stent time was 63 d (range 27-251 d). The median stent time for the BBS group and bile leak group was 62 ± 58 d (range 27-199 d) and 92 ± 81 d (range 48-251 d), respectively. All 17 patients underwent successful FCSEMS removal. Long term follow-up was obtained for a median of 575 d (range 28-1435 d). Complications occurred in 5 of 17 patients (29%) and included: migration (n=2), stent clogging (n=1), cholangitis (n=1), and sepsis with hepatic abscess (n=1). CONCLUSION: Placement of fully covered self-expanding metal stents may be used in the management of benign biliary strictures and bile leaks with a low rate of complications.展开更多
BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic...BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic retrograde cholangiopancreatography.Fully covered self-expanding metal stent(FCSEMS)has gained increasing attention in the management of difficult CBDS.AIM To manufacture a drug-eluting FCSEMS,which can achieve controlled release of stone-dissolving agents and speed up the dissolution of CBDS.METHODS Customized covered nitinol stents were adopted.Sodium cholate(SC)and disodium ethylene diamine tetraacetic acid(EDTA disodium,EDTA for short)were used as stone-dissolving agents.Three different types of drug-eluting stents were manufactured by dip coating(Stent I),coaxial electrospinning(Stent II),and dip coating combined with electrospinning(Stent III),respectively.The drugrelease behavior and stone-dissolving efficacy of these stents were evaluated in vitro to sort out the best manufacturing method.And the selected stonedissolving stents were further put into porcine CBD to evaluate their biosecurity.RESULTS Stent I and Stent II had obvious burst release of drugs in the first 5 d while Stent III presented controlled and sustainable drug release for 30 d.In still buffer,the final stone mass-loss rate of each group was 5.19%±0.69%for naked FCSEMS,20.37%±2.13%for Stent I,24.57%±1.45%for Stent II,and 33.72%±0.67%for Stent III.In flowing bile,the final stone mass-loss rate of each group was 5.87%±0.25%for naked FCSEMS,6.36%±0.48%for Stent I,6.38%±0.37%for Stent II,and 8.15%±0.27%for Stent III.Stent III caused the most stone mass-loss no matter in still buffer or in flowing bile,which was significantly higher than those of other groups(P<0.05).In vivo,Stent III made no difference from naked FCSEMS in serological analysis(P>0.05)and histopathological examination(P>0.05).CONCLUSION The novel SC and EDTA-eluting FCSEMS is efficient in diminishing CBDS in vitro.When conventional endoscopic techniques fail to remove difficult CBDS,SC and EDTA-eluting FCSEMS implantation may be considered a promising alternative.展开更多
AIM:To present a series of covered self-expandable metal stents(CSEMS) placed for different indications and to evaluate the effectiveness,complications and extractability of these devices.METHODS:We therefore retrospe...AIM:To present a series of covered self-expandable metal stents(CSEMS) placed for different indications and to evaluate the effectiveness,complications and extractability of these devices.METHODS:We therefore retrospectively reviewed the courses of patients who received CSEMS due to malignant as well as benign biliary strictures and postsphincterotomy bleeding in our endoscopic unit between January 2010 and October 2011.RESULTS:Twenty-six patients received 28 stents due to different indications(20 stents due to malignant biliary strictures,six stents due to benign biliary strictures and two stents due to post-sphincterotomy bleeding).Biliary obstruction was relieved in all cases,regardless of the underlying cause.Hemostasis could be achieved in the two patients who received the stents for this purpose.Complications occurred in five patients(18%).Two patients(7%) developed cholecystitis,stents dislocated/migrated in other two patients(7%),and in one patient(3.6%) stent occlusion was documented during the study period.Seven stents were extracted endoscopically.Removal of stents was easily possible in all cases in which it was desired using standard forceps.Twelve patients underwent surgery with pylorus preserving duodenopancreatectomy.In all patients stents could be removed during the operation without difficulties.CONCLUSION:Despite the higher costs of these devices,fully covered self-expanding metal stents may be suitable to relief biliary obstruction due to bile duct stenosis,regardless of the underlying cause.CSEMS may also represent an effective treatment strategy of severe post-sphincterotomy bleeding,not controlled by other measures.展开更多
Background Despite the current availability of flow diverter devices(FDD), problems remains regarding optimal endovascular treatment(EVT) for blood blister-like aneurysms(BBAs) of the internal carotid artery(ICA). Obj...Background Despite the current availability of flow diverter devices(FDD), problems remains regarding optimal endovascular treatment(EVT) for blood blister-like aneurysms(BBAs) of the internal carotid artery(ICA). Objective To evaluate the safety and efficacy of EVT of BBAs in the ICA with a Willis covered stent. Methods 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Results 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Conclusion Our initial results demonstrate that reconstructive EVT using a Willis covered stent provides a viable approach to treat ICA BBAs. However, an expanded clinical evaluation and larger cohort are needed to confirm the results.展开更多
Reactive fragment enhances lethality by incorporating the defeat mechanisms of kinetic energy and chemical energy into a unitary damage unit. Combined studies on the behavior of reactive fragment initiating covered ex...Reactive fragment enhances lethality by incorporating the defeat mechanisms of kinetic energy and chemical energy into a unitary damage unit. Combined studies on the behavior of reactive fragment initiating covered explosive are performed theoretically and experimentally. The results in- dicate that the response of the covered explosive subjected to reactive fragment is not consistent with the classical shock initiation model. When impacting and penetrating into the covered explosive, the reactive fragment releases great amounts of thermo-chemical energy up to 5. 68 times of its kinetic energy into the explosive due to violent chemical reactions. This impact-induced chemical energy re- lease behavior of the reactive fragment significantly enhances the initiation capability and damage effects on the covered explosive.展开更多
Delayed intra-abdominal hemorrhage after pancreatic surgery is a potentially lethal complication.Transarterial coil embolization and/or the placing of an endovascular stent are minimally invasive and effective procedu...Delayed intra-abdominal hemorrhage after pancreatic surgery is a potentially lethal complication.Transarterial coil embolization and/or the placing of an endovascular stent are minimally invasive and effective procedures.An artery that is extensively eroded and rendered friable due to operative skeletonization or postoperative inflammation sometimes contributes to delayed intra-abdominal hemorrhage or rebleeding after coil embolization.This report presents a case of successful management of postoperative hemorrhage in a-74-year-old Japanese male.He experienced bleeding from a pseudoaneurysm of the brittle hepatic artery following total pancreatectomy.Initially the pseudoaneurysm was successfully treated with covered coronary stent-grafts,but rebleeding occurred 1 mo later due to the brittleness of the artery.Rebleeding was definitively managed by the complete packing of the stent by coil embolization.He remains stable at 18 mo following the f inal embolization.A stent graft can be used for protecting a brittle artery to avoid injury by coil embolization.展开更多
AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(...AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour展开更多
Plastic stent insertion is a treatment option for pancreatic duct stricture with chronic pancreatitis.However, recurrent stricture is a limitation after removing the plastic stent.Self-expandable metal stents have lon...Plastic stent insertion is a treatment option for pancreatic duct stricture with chronic pancreatitis.However, recurrent stricture is a limitation after removing the plastic stent.Self-expandable metal stents have long diameters and patency.A metal stent has become an established management option for pancreatic duct stricture caused by malignancy but its use in benign stricture is still controversial.We introduce a young patient who had chronic pancreatitis and underwent several plastic stent insertions due to recurrent pancreatic duct stricture.His symptoms improved after using a fully covered self-expandable metal covered stent and there was no recurrence found at follow-up at the outpatient department.展开更多
In order to improve the wetting properties of graphite with Al melt and reduce the oxidation of the graphite, by which the segregation of components during the liquid-stir-casting process could be prevented. In this p...In order to improve the wetting properties of graphite with Al melt and reduce the oxidation of the graphite, by which the segregation of components during the liquid-stir-casting process could be prevented. In this paper, a uniform thin nano-film of CeO2, about 20 nm thick, was successfully prepared onto graphite powder surface by heterogeneous nu-cleation process. The results show that an obvious chemical reaction did exit between CeO2 film and graphite with the formation of Ce-O-C bond, leading to a shift of the binding energy of C and Ce. The cover with CeO2 film illustrates a distinct change of surface state of graphite with a decrease of angle of contact.展开更多
Exploration for buried gold ores and other deeply buried ores, especially in high altitude localities, is one of the tough challenges facing the geological world today.Fast and efficient ore prospecting methods are ba...Exploration for buried gold ores and other deeply buried ores, especially in high altitude localities, is one of the tough challenges facing the geological world today.Fast and efficient ore prospecting methods are badly needed to deal with the situation. This paper documents a test that, for the first time, uses an electrogeochemical approach to prospect ores in the alpine meadow-covered Bangzhuoma area and its periphery in Qinghai–Tibet Plateau.The results were compared with conventional soil measurements from a 2 D prospection, and an ideal model of electrogeochemical anomaly formation in the area was established based on the comparison in order to provide theoretical guidance to buried ore prospecting in areas with similar conditions. The research shows that:(1) For exploration of deeply-buried mineral deposits, an electrogeochemical approach is better than soil measurements in terms of correspondence between element content values and anomaly forms and spatial distribution of known deposits in sections. Anomalies of high to low temperature element associations(Bi–Mo; Au–Ag–As–Bi and Au–Ag)and clear zonation were also observed along vertical vein runs in the sections. Based on integration of the observation with geological characteristics of the sections, we propose to use Au, Ag and As as the electrogeochemical indicators and Bi and Mo as the electrogeochemical tracing elementsto guide further analysis.(2) Judging from element statistics and the scale, intensity, and range of anomalies in plan maps, we found that an electrogeochemical approach is less affected by topography and secondary actions. The plan maps also show that elemental differentiation coefficients of the study area are in an ascending order of Ag(0.67) \ Mo(0.85) \ Bi(0.97) \ Au(1.51) \ As(2.35),better representing the element distribution in the area and yielding more striking and concentrated anomalies for known deposits than that of the soil measurements. Apart from that, electrogeochemical anomalies were observed in the south of lines 002 and 003 and the central of lines 008 and 009. We suggest the existence of deeply-buried mineral deposits based on analyses of element combinations and gold grade variations in samples taken from exploratory trenches in the area.(3) A three-stage(referring to the ore body dissolution, the mineralogenetic particle migration, and the mineralogenetic particle unloading) electrogeochemical ideal model was established for the study area, which takes into account moderate rainfall, high altitude, low air pressure, well-developed vegetation and roots, and an Upper Triassic Nieru Formation carbonaceous sandy slate as overburden.展开更多
By using a degree-day based distributed hydrological model, regimes of glacial runoff from the Koxkar glacier during 2007-2011 are simulated, and variations and characteristics of major hydrological components are dis...By using a degree-day based distributed hydrological model, regimes of glacial runoff from the Koxkar glacier during 2007-2011 are simulated, and variations and characteristics of major hydrological components are discussed. The results show that the meltwater runoff contributes 67.4%, of the proglacial discharge, out of which snowmelt, clean ice melting, buried-ice ablation and ice-cliff backwasting account for 22.4%, 21.9%, 17.9% and 5.3% of the total melt runoff, respectively. Rainfall runoff is significant in mid-latitude glacierized mountain areas like Tianshan and Karakorum. In the Koxkar glacier catchment, about 11.5% of stream water is initiated from liquid precipitation. Spatial distributions for each glacial runoff component reveal the importance of climatic gradients, local topography and morphology on glacial runoff generation, and temporal variations of these components is closely related to the annual cycle of catchment meteorology and glacier storage. Four stages are recognized in the seasonal variations of glacier storage, reflecting changes in meltwater yields, meteorological conditions and drainage systems in the annual hydrological cycle.展开更多
Several techniques have been reported to address different endovascular device failures. We report the case of a premature deployment of a covered balloon mounted stent during endovascular repair of a posttraumatic ca...Several techniques have been reported to address different endovascular device failures. We report the case of a premature deployment of a covered balloon mounted stent during endovascular repair of a posttraumatic carotid-cavernous fistula(CCF). A 50-year-old male suffered a fall resulting in loss of consciousness and multiple facial fractures. Five weeks later, he developed decreased left visual acuity, proptosis, chemosis, limited eye movements and cranial/orbit bruit. Cerebral angiography demonstrated a direct left CCF and endovascular repair with a 5.0 mm × 19 mm covered stent was planned. Once in the lacerum segment, increased resistance was encountered and the stent was withdrawn resulting in premature deployment. A 3 mm × 9 mm balloon was advanced over an exchange length microwire and through the stent lumen. Once distal to the stent, the balloon was inflated and slowly pulled back in contact with the stent. All devices were successfully withdrawn as a unit. The use of a balloon to retrieve a prematurely deployed balloon mounted stent is a potential rescue option if leaving the stent in situ carries risks.展开更多
AIM: To evaluate transjugular intrahepatic portosystemic shunt (TIPS) with covered stents for hepatocellular carcinoma (HCC) with main portal vein tumor thrombus (PVTT).
Fully covered self-expandable metal stents(FCSEMS)represent the latest advancement of metal biliary stents used to endoscopically treat a variety of obstructive biliary pathology.A large stent diameter and synthetic c...Fully covered self-expandable metal stents(FCSEMS)represent the latest advancement of metal biliary stents used to endoscopically treat a variety of obstructive biliary pathology.A large stent diameter and synthetic covering over the tubular mesh prolong stent patency and reduce risk for tissue hyperplasia and tumor ingrowth.Additionally,FCSEMS can be easily removed.All these features address issues faced by plastic and uncovered metal stents.The purpose of this paper is to comprehensively review the application of FCSEMS in benign and malignant biliary strictures,biliary leak,and post-sphincterotomy bleeding.展开更多
Remote sensing data have been widely applied to extract minerals in geologic exploration, however, in areas covered by vegetation, extracted mineral information has mostly been small targets bearing little information...Remote sensing data have been widely applied to extract minerals in geologic exploration, however, in areas covered by vegetation, extracted mineral information has mostly been small targets bearing little information. In this paper, we present a new method for mineral extraction aimed at solving the difficulty of mineral identification in vegetation covered areas. The method selected six sets of spectral difference coupling between soil and plant(SVSCD). These sets have the same vegetation spectra reflectance and a maximum different reflectance of soil and mineral spectra from Hyperion image based on spectral reflectance characteristics of measured spectra. The central wavelengths of the six, selected band pairs were 2314 and 701 nm, 1699 and 721 nm, 1336 and 742 nm, 2203 and 681 nm, 2183 and 671 nm, and 2072 and 548 nm. Each data set's reflectance was used to calculate the difference value. After band difference calculation, vegetation information was suppressed and mineral abnormal information was enhanced compared to the scatter plot of original band. Six spectral difference couplings, after vegetation inhibition, were arranged in a new data set that requires two components that have the largest eigenvalue difference from principal component analysis(PCA). The spatial geometric structure features of PC1 and PC2 was used to identify altered minerals by spectral feature fitting(SFF). The collecting rocks from the 10 points that were selected in the concentration of mineral extraction were analyzed under a high-resolution microscope to identify metal minerals and nonmetallic minerals. Results indicated that the extracted minerals were well matched with the verified samples, especially with the sample 2, 4, 5 and 8. It demonstrated that the method can effectively detect altered minerals in vegetation covered area in Hyperion image.展开更多
Background:Symptomatic vertebral artery dissecting aneurysm(VADA)is a challenging disease with controversy on treatment strategy due to anatomic configuration and their nature.Moreover,the outcomes of reconstructive t...Background:Symptomatic vertebral artery dissecting aneurysm(VADA)is a challenging disease with controversy on treatment strategy due to anatomic configuration and their nature.Moreover,the outcomes of reconstructive treatment have not been well established.Objective:To evaluate the safety and efficacy of reconstructive endovascular treatment(EVT)for symptomatic VADAs with Willis covered stent.Methods:We evaluated retrospectively 13 patients with symptomatic VADAs who treated with Willis covered stent,compared with stent-assisted coiling(SAC)on the characteristics,posttreatment course,angiographic and clinical follow-up outcomes at an average of 14.4 months(range,3-48 months).Results:A total of 33 patients with symptomatic VADAs were reviewed,23 of these patients with ruptured VADAs.The technical successful rate is 100%respectively in Willis covered stent(Group A)and SAC(Group B,n=20).The initial complete occlusion rate was significant higher in group A(100%)than group B(30%)(p<0.01).Major procedure-related complications were not significant different in the two groups.Serial follow-up angiograms revealed 5 recurrent VADAs in group B and no recurrence in group A(p>0.05).No obvious in-stent stenosis and no re-hemorrhage and delayed ischemic symptoms during the follow-up period.The final angiograms of all survived patients demonstrated the complete occlusion rate was higher in group A(100%)than group B(80%),but no significant statistical difference(p>0.05).Clinical outcomes were favorable in 31(93.9%),severe disability occurred in one in group B,and only one death in group A.The final clinical outcomes were also not significant difference in the two groups(p>0.05).Conclusions:Our initial result demonstrated reconstructive EVT with Willis covered stent provides a viable approach for selected symptomatic VADAs involving the intracranial and extracranial segments,which is similar to favorable results with SAC.However,an expanded clinical experiences and larger cohort studies are needed.展开更多
Blood blister-like aneurysms(BBAs)are fragile and difficult to treat.However,the optimal treatment has yet to be determined.Pipeline embolization devices and Willis covered stent implementation are still controversial...Blood blister-like aneurysms(BBAs)are fragile and difficult to treat.However,the optimal treatment has yet to be determined.Pipeline embolization devices and Willis covered stent implementation are still controversial strategies for treating BBA.Herein,we report a case of recurrent BBA successfully treated with a Willis covered stent.A long-term follow-up angiography after the procedure indicated complete occlusion of the aneurysm.This case demonstrates the safety and efficacy of applying the Wills cover stent in the treatment of recurrent BBA after Pipeline implantation.展开更多
Biliary fully covered self-expanding metal stents (FCSEMS) are now being used to treat several benign biliary conditions. Advantages include small predeployment and large postexpansion diameters in addition to an easy...Biliary fully covered self-expanding metal stents (FCSEMS) are now being used to treat several benign biliary conditions. Advantages include small predeployment and large postexpansion diameters in addition to an easy insertion technique. Lack of imbedding of the metal into the bile duct wall enables removability. In benign biliary strictures that usually require multiple procedures, despite the substantially higher cost of FCSEMS compared with plastic stents, the use of FCSEMS is offset by the reduced number of endoscopic retrograde cholangiopancreatography interventions required to achieve stricture resolution. In the same way, FCSEMS have also been employed to treat complex bile leaks, perforation and bleeding after endoscopic biliary sphincterotomy and as an aid to maintain permanent drainage tracts obtained by means of Endoscopic Ultrasound-guided biliary drainage. Good success rates have been achieved in all these conditions with an acceptable number of complications. FCSEMS were successfully removed in all patients. Comparative studies of FCSEMS and plastic stents are needed to demonstrate efficacy and cost-effectiveness展开更多
Background:To report the clinical results and experiences of endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases(ICAVDs)using Willis covered st...Background:To report the clinical results and experiences of endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases(ICAVDs)using Willis covered stents.METHODS:Seventy-three patients with ICAVD who received Willis covered stent implantation between November 2013 and September 2018 were retrospectively reviewed.The clinical data of endoleak management and postoperative surveillance were analyzed.RESULTS:Seventy-three cases with ICAVD,including 57 aneurysms,11 carotid-cavernous sinus fistulas(CCF),and 5 surgical injuries,were all successfully installed with covered stents.Total isolation of ICAVDs was achieved in 59 patients(80.8%),and endoleaks were observed in 14 patients(19.2%).Of the 14 patients with endoleaks,12 had type I endoleaks and 2 had type II;13 had aneurysms and one had CCF.10 patients with type I endoleaks received balloon dilatation,and 7 of them underwent a second stent-graft implantation after then.One patient with type II endoleak received embolization of the branch artery,and another one received follow-up observation.Endoleaks resolved in 6 patients and were minimal in 5 patients after balloon dilatation or the second stent implantation.During the follow-up period,minor endoleaks spontaneously resolved in 4 patients and minimal endoleaks were still demonstrated in 4 patients without enlargement of residual lumen and rupture.CONCLUSIONS:Endoleaks are the major complication after endovascular repair of ICAVDs and represent one of the limitations of this procedure.Improving the understanding and management of endoleaks can be beneficial in the clinical setting,including the popularization and application of this technique.展开更多
基金supported by the National Natural Science Foundation of China[Grant No.72374186]。
文摘Objective Antiretroviral drugs covered by medical insurance have been gradually used by people living with human immunodeficiency virus(PLWH)in recent years in China.This study aimed to analyze their willingness to pay(WTP)for antiretroviral drugs.Methods A mixed-methods study design involving a cross-sectional survey and in-depth interviews was conducted.A cross-sectional survey was performed to collect data on the general characteristics,economic status,antiretroviral therapy(ART)status,and WTP of PLWH in 18 Chinese cities from August 2022 to February 2023.Multivariate logistic regression was used to analyze the factors associated with WTP.Representatives of PLWH were interviewed via in-depth interviews,and the data were thematically analyzed.Results Among the 941 PLWH,271(28.80%)were willing to pay for antiretroviral drugs covered by medical insurance.For basic medical insurance for urban and rural residents,PLWH with the following characteristics were more willing to pay:an educational level of senior high school or technical secondary school,having an undergraduate degree or higher,frequently working away from their hometowns,and homosexual transmission.Off-farm workers and recipients of government medical aid were more unwilling to pay.For basic medical insurance for urban employees,PLWH with the following characteristics were more willing to pay:frequently working away from their hometowns;homosexual transmission;personal annual income≥100,000 CNY;and adverse events of antiretroviral drugs.The main reasons for PLWH’s WTP for antiretroviral drugs covered by medical insurance were that the drugs had fewer adverse events and were easier to administer.The main reasons for PLWH’s unwillingness to pay were financial difficulties and privacy concerns.Conclusion Nearly one-third of PLWH are willing to pay for antiretroviral drugs covered by medical insurance.In the future,PLWH with a high WTP can be guided to use these drugs.
文摘AIM: To investigate the use of fully covered metal stents in benign biliary strictures (BBS) and bile leaks. METHODS: We studied 17 patients, at Harbor-UCLA Medical center (Los Angeles), with BBS (n=12) and bile leaks (n=5) from July 2007 to February 2012 that had received placement of fully covered self-expanding metal stents (FCSEMs). Fourteen patients had endoscopic placement of VIABIL (Conmed, Utica, New York, United States) stents and three had Wallflex (Boston Scientific, Mass) stents. FCSEMS were 8 mm or 10 mm in diameter and 4 cm to 10 cm in length. Patients were followed at regular intervals to evaluate for symptoms and liver function tests. FCSEMS were removed after 4 or more weeks. Resolution of BBS and leak was documented cholangiographically following stent removal. Stent patency can be defined as adequate bile and contrast flow from the stent and into the ampulla during endoscopic retrograde cholangiopancreatography (ERCP) without clinical signs and/or symptoms of biliary obstruction. Criterion for bile leak resolution at ERCP is defined as absence of contrast extravasation from the common bile duct, cystic duct remanent, or gall blad-der fossa. Rate of complications such as migration, and instent occlusion were recorded. Failure of endoscopic therapy was defined as persistent biliary stenosis or continuous biliary leakage after 12 mo of stent placement. RESULTS: All 17 patients underwent successful FC- SEMS placement and removal. Etiologies of BBS included: cholecystectomies (n=8), cholelithiasis (n=2), hepatic artery compression (n=1), pancreatitis (n=2), and Whipple procedure (n=1). All bile leaks occurred following cholecystectomy. The anatomic location of BBS varied: distal common bile duct (n=7), common hepatic duct (n=1), hepaticojejunal anastomosis (n=2), right intrahepatic duct (n=1), and choledochoduo-denal anastomatic junction (n=1). All bile leaks were found to be at the cystic duct. Twelve of 17 patients had failed prior stent placement or exchange. Resolution of the biliary strictures and bile leaks was achieved in 16 of 17 patients (94%). The overall median stent time was 63 d (range 27-251 d). The median stent time for the BBS group and bile leak group was 62 ± 58 d (range 27-199 d) and 92 ± 81 d (range 48-251 d), respectively. All 17 patients underwent successful FCSEMS removal. Long term follow-up was obtained for a median of 575 d (range 28-1435 d). Complications occurred in 5 of 17 patients (29%) and included: migration (n=2), stent clogging (n=1), cholangitis (n=1), and sepsis with hepatic abscess (n=1). CONCLUSION: Placement of fully covered self-expanding metal stents may be used in the management of benign biliary strictures and bile leaks with a low rate of complications.
基金the National Natural Science Foundation of China,No.81470904and Shanghai Committee of Science and Technology,No.14411963000
文摘BACKGROUND The treatment of difficult common bile duct stones(CBDS)remains a big challenge around the world.Biliary stenting is a widely accepted rescue method in patients with failed stone extraction under endoscopic retrograde cholangiopancreatography.Fully covered self-expanding metal stent(FCSEMS)has gained increasing attention in the management of difficult CBDS.AIM To manufacture a drug-eluting FCSEMS,which can achieve controlled release of stone-dissolving agents and speed up the dissolution of CBDS.METHODS Customized covered nitinol stents were adopted.Sodium cholate(SC)and disodium ethylene diamine tetraacetic acid(EDTA disodium,EDTA for short)were used as stone-dissolving agents.Three different types of drug-eluting stents were manufactured by dip coating(Stent I),coaxial electrospinning(Stent II),and dip coating combined with electrospinning(Stent III),respectively.The drugrelease behavior and stone-dissolving efficacy of these stents were evaluated in vitro to sort out the best manufacturing method.And the selected stonedissolving stents were further put into porcine CBD to evaluate their biosecurity.RESULTS Stent I and Stent II had obvious burst release of drugs in the first 5 d while Stent III presented controlled and sustainable drug release for 30 d.In still buffer,the final stone mass-loss rate of each group was 5.19%±0.69%for naked FCSEMS,20.37%±2.13%for Stent I,24.57%±1.45%for Stent II,and 33.72%±0.67%for Stent III.In flowing bile,the final stone mass-loss rate of each group was 5.87%±0.25%for naked FCSEMS,6.36%±0.48%for Stent I,6.38%±0.37%for Stent II,and 8.15%±0.27%for Stent III.Stent III caused the most stone mass-loss no matter in still buffer or in flowing bile,which was significantly higher than those of other groups(P<0.05).In vivo,Stent III made no difference from naked FCSEMS in serological analysis(P>0.05)and histopathological examination(P>0.05).CONCLUSION The novel SC and EDTA-eluting FCSEMS is efficient in diminishing CBDS in vitro.When conventional endoscopic techniques fail to remove difficult CBDS,SC and EDTA-eluting FCSEMS implantation may be considered a promising alternative.
文摘AIM:To present a series of covered self-expandable metal stents(CSEMS) placed for different indications and to evaluate the effectiveness,complications and extractability of these devices.METHODS:We therefore retrospectively reviewed the courses of patients who received CSEMS due to malignant as well as benign biliary strictures and postsphincterotomy bleeding in our endoscopic unit between January 2010 and October 2011.RESULTS:Twenty-six patients received 28 stents due to different indications(20 stents due to malignant biliary strictures,six stents due to benign biliary strictures and two stents due to post-sphincterotomy bleeding).Biliary obstruction was relieved in all cases,regardless of the underlying cause.Hemostasis could be achieved in the two patients who received the stents for this purpose.Complications occurred in five patients(18%).Two patients(7%) developed cholecystitis,stents dislocated/migrated in other two patients(7%),and in one patient(3.6%) stent occlusion was documented during the study period.Seven stents were extracted endoscopically.Removal of stents was easily possible in all cases in which it was desired using standard forceps.Twelve patients underwent surgery with pylorus preserving duodenopancreatectomy.In all patients stents could be removed during the operation without difficulties.CONCLUSION:Despite the higher costs of these devices,fully covered self-expanding metal stents may be suitable to relief biliary obstruction due to bile duct stenosis,regardless of the underlying cause.CSEMS may also represent an effective treatment strategy of severe post-sphincterotomy bleeding,not controlled by other measures.
基金financially supported by the National Natural Scientific Fund of China(grant number 81771951)the Science and Technology Commission of Shanghai(grant number 14DZ1941204)
文摘Background Despite the current availability of flow diverter devices(FDD), problems remains regarding optimal endovascular treatment(EVT) for blood blister-like aneurysms(BBAs) of the internal carotid artery(ICA). Objective To evaluate the safety and efficacy of EVT of BBAs in the ICA with a Willis covered stent. Methods 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Results 20 consecutive patients(5 men and 15 women) with ruptured BBAs underwent EVT using a Willis covered stent in two institutions from March 2013 to March 2018. Clinical observations, angiographic characteristics, and procedural and follow-up outcomes were retrospectively evaluated. Conclusion Our initial results demonstrate that reconstructive EVT using a Willis covered stent provides a viable approach to treat ICA BBAs. However, an expanded clinical evaluation and larger cohort are needed to confirm the results.
基金Supported by the National Innovation Funds(7130619)
文摘Reactive fragment enhances lethality by incorporating the defeat mechanisms of kinetic energy and chemical energy into a unitary damage unit. Combined studies on the behavior of reactive fragment initiating covered explosive are performed theoretically and experimentally. The results in- dicate that the response of the covered explosive subjected to reactive fragment is not consistent with the classical shock initiation model. When impacting and penetrating into the covered explosive, the reactive fragment releases great amounts of thermo-chemical energy up to 5. 68 times of its kinetic energy into the explosive due to violent chemical reactions. This impact-induced chemical energy re- lease behavior of the reactive fragment significantly enhances the initiation capability and damage effects on the covered explosive.
文摘Delayed intra-abdominal hemorrhage after pancreatic surgery is a potentially lethal complication.Transarterial coil embolization and/or the placing of an endovascular stent are minimally invasive and effective procedures.An artery that is extensively eroded and rendered friable due to operative skeletonization or postoperative inflammation sometimes contributes to delayed intra-abdominal hemorrhage or rebleeding after coil embolization.This report presents a case of successful management of postoperative hemorrhage in a-74-year-old Japanese male.He experienced bleeding from a pseudoaneurysm of the brittle hepatic artery following total pancreatectomy.Initially the pseudoaneurysm was successfully treated with covered coronary stent-grafts,but rebleeding occurred 1 mo later due to the brittleness of the artery.Rebleeding was definitively managed by the complete packing of the stent by coil embolization.He remains stable at 18 mo following the f inal embolization.A stent graft can be used for protecting a brittle artery to avoid injury by coil embolization.
文摘AIM To investigate the efficacy of double-layered covered stent in the treatment of malignant oesophageal obstructions.METHODS A systematic review and meta-analysis was performed following the PRISMA process. Pub Med(Medline),EMBASE(Excerpta Medical Database),AMED(Allied and Complementary medicine Database),Scopus and online content,were searched for studies reporting on the Ni Ti-S polyurethane-covered double oesophageal stent for the treatment of malignant dysphagia. Weighted pooled outcomes were synthesized with a random effects model to account for clinical heterogeneity. All studies reporting the outcome of palliative management of dysphagia due to histologically confirmed malignant oesophageal obstruction using double-layered covered nitinol stent were included. The level of statistical significance was set at α = 0.05.RESULTS Six clinical studies comprising 250 patients in total were identified. Pooled technical success of stent insertion was 97.2%(95%CI: 94.8%-98.9%; I2 = 5.8%). Pooled complication rate was 27.6%(95%CI: 20.7%-35.2%; I2 = 41.9%). Weighted improvement of dysphagia on a scale of 0-5 scoring system was-2.00 [95%CI:-2.29%-(-1.72%); I2 = 87%]. Distal stent migration was documented in 10 out of the 250 cases examined.Pooled stent migration rate was 4.7%(95%CI: 2.5%-7.7%; I2 = 0%). Finally,tumour overgrowth was reported in 34 out of the 250 cases with pooled rate of tumour overgrowth of 11.2%(95%CI: 3.7%-22.1%; I2 = 82.2%). No funnel plot asymmetry to suggest publication bias(bias = 0.39,P = 0.78). In the sensitivity analysis all results were largely similar between the fixed and random effects models.CONCLUSION The double-layered nitinol stent provides immediate relief of malignant dysphagia with low rates of stent migration and tumour
文摘Plastic stent insertion is a treatment option for pancreatic duct stricture with chronic pancreatitis.However, recurrent stricture is a limitation after removing the plastic stent.Self-expandable metal stents have long diameters and patency.A metal stent has become an established management option for pancreatic duct stricture caused by malignancy but its use in benign stricture is still controversial.We introduce a young patient who had chronic pancreatitis and underwent several plastic stent insertions due to recurrent pancreatic duct stricture.His symptoms improved after using a fully covered self-expandable metal covered stent and there was no recurrence found at follow-up at the outpatient department.
基金Project supported by the National '973' Project (G19990649)
文摘In order to improve the wetting properties of graphite with Al melt and reduce the oxidation of the graphite, by which the segregation of components during the liquid-stir-casting process could be prevented. In this paper, a uniform thin nano-film of CeO2, about 20 nm thick, was successfully prepared onto graphite powder surface by heterogeneous nu-cleation process. The results show that an obvious chemical reaction did exit between CeO2 film and graphite with the formation of Ce-O-C bond, leading to a shift of the binding energy of C and Ce. The cover with CeO2 film illustrates a distinct change of surface state of graphite with a decrease of angle of contact.
基金supported by the National Key Research and Development Program of China(Grant No.2016YFC0600603)
文摘Exploration for buried gold ores and other deeply buried ores, especially in high altitude localities, is one of the tough challenges facing the geological world today.Fast and efficient ore prospecting methods are badly needed to deal with the situation. This paper documents a test that, for the first time, uses an electrogeochemical approach to prospect ores in the alpine meadow-covered Bangzhuoma area and its periphery in Qinghai–Tibet Plateau.The results were compared with conventional soil measurements from a 2 D prospection, and an ideal model of electrogeochemical anomaly formation in the area was established based on the comparison in order to provide theoretical guidance to buried ore prospecting in areas with similar conditions. The research shows that:(1) For exploration of deeply-buried mineral deposits, an electrogeochemical approach is better than soil measurements in terms of correspondence between element content values and anomaly forms and spatial distribution of known deposits in sections. Anomalies of high to low temperature element associations(Bi–Mo; Au–Ag–As–Bi and Au–Ag)and clear zonation were also observed along vertical vein runs in the sections. Based on integration of the observation with geological characteristics of the sections, we propose to use Au, Ag and As as the electrogeochemical indicators and Bi and Mo as the electrogeochemical tracing elementsto guide further analysis.(2) Judging from element statistics and the scale, intensity, and range of anomalies in plan maps, we found that an electrogeochemical approach is less affected by topography and secondary actions. The plan maps also show that elemental differentiation coefficients of the study area are in an ascending order of Ag(0.67) \ Mo(0.85) \ Bi(0.97) \ Au(1.51) \ As(2.35),better representing the element distribution in the area and yielding more striking and concentrated anomalies for known deposits than that of the soil measurements. Apart from that, electrogeochemical anomalies were observed in the south of lines 002 and 003 and the central of lines 008 and 009. We suggest the existence of deeply-buried mineral deposits based on analyses of element combinations and gold grade variations in samples taken from exploratory trenches in the area.(3) A three-stage(referring to the ore body dissolution, the mineralogenetic particle migration, and the mineralogenetic particle unloading) electrogeochemical ideal model was established for the study area, which takes into account moderate rainfall, high altitude, low air pressure, well-developed vegetation and roots, and an Upper Triassic Nieru Formation carbonaceous sandy slate as overburden.
基金supported by the Knowledge Innovation Program of the Chinese Academy of Sciences under Grant No. KZCX2-YW-GJ04National Nature Science Foundation of China (NSFC) under Grant Nos. 41130641 and 41271078
文摘By using a degree-day based distributed hydrological model, regimes of glacial runoff from the Koxkar glacier during 2007-2011 are simulated, and variations and characteristics of major hydrological components are discussed. The results show that the meltwater runoff contributes 67.4%, of the proglacial discharge, out of which snowmelt, clean ice melting, buried-ice ablation and ice-cliff backwasting account for 22.4%, 21.9%, 17.9% and 5.3% of the total melt runoff, respectively. Rainfall runoff is significant in mid-latitude glacierized mountain areas like Tianshan and Karakorum. In the Koxkar glacier catchment, about 11.5% of stream water is initiated from liquid precipitation. Spatial distributions for each glacial runoff component reveal the importance of climatic gradients, local topography and morphology on glacial runoff generation, and temporal variations of these components is closely related to the annual cycle of catchment meteorology and glacier storage. Four stages are recognized in the seasonal variations of glacier storage, reflecting changes in meltwater yields, meteorological conditions and drainage systems in the annual hydrological cycle.
文摘Several techniques have been reported to address different endovascular device failures. We report the case of a premature deployment of a covered balloon mounted stent during endovascular repair of a posttraumatic carotid-cavernous fistula(CCF). A 50-year-old male suffered a fall resulting in loss of consciousness and multiple facial fractures. Five weeks later, he developed decreased left visual acuity, proptosis, chemosis, limited eye movements and cranial/orbit bruit. Cerebral angiography demonstrated a direct left CCF and endovascular repair with a 5.0 mm × 19 mm covered stent was planned. Once in the lacerum segment, increased resistance was encountered and the stent was withdrawn resulting in premature deployment. A 3 mm × 9 mm balloon was advanced over an exchange length microwire and through the stent lumen. Once distal to the stent, the balloon was inflated and slowly pulled back in contact with the stent. All devices were successfully withdrawn as a unit. The use of a balloon to retrieve a prematurely deployed balloon mounted stent is a potential rescue option if leaving the stent in situ carries risks.
基金Supported by Science and Technology Planning Project of Guangdong Province,China,No.2012B010200027The Key Technologies RD Program of Guangzhou,ChinaThe Presidential Foundation of the Nanfang Hospital,Southern Medical University,Guangzhou,China,No.2011B006
文摘AIM: To evaluate transjugular intrahepatic portosystemic shunt (TIPS) with covered stents for hepatocellular carcinoma (HCC) with main portal vein tumor thrombus (PVTT).
文摘Fully covered self-expandable metal stents(FCSEMS)represent the latest advancement of metal biliary stents used to endoscopically treat a variety of obstructive biliary pathology.A large stent diameter and synthetic covering over the tubular mesh prolong stent patency and reduce risk for tissue hyperplasia and tumor ingrowth.Additionally,FCSEMS can be easily removed.All these features address issues faced by plastic and uncovered metal stents.The purpose of this paper is to comprehensively review the application of FCSEMS in benign and malignant biliary strictures,biliary leak,and post-sphincterotomy bleeding.
基金Under the auspices of National Science and Technology Major Project of China(No.04-Y20A35-9001-15/17)the Program for JLU Science and Technology Innovative Research Team(No.JLUSTIRT,2017TD-26)the Changbai Mountain Scholars Program,Jilin Province,China
文摘Remote sensing data have been widely applied to extract minerals in geologic exploration, however, in areas covered by vegetation, extracted mineral information has mostly been small targets bearing little information. In this paper, we present a new method for mineral extraction aimed at solving the difficulty of mineral identification in vegetation covered areas. The method selected six sets of spectral difference coupling between soil and plant(SVSCD). These sets have the same vegetation spectra reflectance and a maximum different reflectance of soil and mineral spectra from Hyperion image based on spectral reflectance characteristics of measured spectra. The central wavelengths of the six, selected band pairs were 2314 and 701 nm, 1699 and 721 nm, 1336 and 742 nm, 2203 and 681 nm, 2183 and 671 nm, and 2072 and 548 nm. Each data set's reflectance was used to calculate the difference value. After band difference calculation, vegetation information was suppressed and mineral abnormal information was enhanced compared to the scatter plot of original band. Six spectral difference couplings, after vegetation inhibition, were arranged in a new data set that requires two components that have the largest eigenvalue difference from principal component analysis(PCA). The spatial geometric structure features of PC1 and PC2 was used to identify altered minerals by spectral feature fitting(SFF). The collecting rocks from the 10 points that were selected in the concentration of mineral extraction were analyzed under a high-resolution microscope to identify metal minerals and nonmetallic minerals. Results indicated that the extracted minerals were well matched with the verified samples, especially with the sample 2, 4, 5 and 8. It demonstrated that the method can effectively detect altered minerals in vegetation covered area in Hyperion image.
基金financially supported by the National Natural Science Foundation of China[grant numbers 81771951]
文摘Background:Symptomatic vertebral artery dissecting aneurysm(VADA)is a challenging disease with controversy on treatment strategy due to anatomic configuration and their nature.Moreover,the outcomes of reconstructive treatment have not been well established.Objective:To evaluate the safety and efficacy of reconstructive endovascular treatment(EVT)for symptomatic VADAs with Willis covered stent.Methods:We evaluated retrospectively 13 patients with symptomatic VADAs who treated with Willis covered stent,compared with stent-assisted coiling(SAC)on the characteristics,posttreatment course,angiographic and clinical follow-up outcomes at an average of 14.4 months(range,3-48 months).Results:A total of 33 patients with symptomatic VADAs were reviewed,23 of these patients with ruptured VADAs.The technical successful rate is 100%respectively in Willis covered stent(Group A)and SAC(Group B,n=20).The initial complete occlusion rate was significant higher in group A(100%)than group B(30%)(p<0.01).Major procedure-related complications were not significant different in the two groups.Serial follow-up angiograms revealed 5 recurrent VADAs in group B and no recurrence in group A(p>0.05).No obvious in-stent stenosis and no re-hemorrhage and delayed ischemic symptoms during the follow-up period.The final angiograms of all survived patients demonstrated the complete occlusion rate was higher in group A(100%)than group B(80%),but no significant statistical difference(p>0.05).Clinical outcomes were favorable in 31(93.9%),severe disability occurred in one in group B,and only one death in group A.The final clinical outcomes were also not significant difference in the two groups(p>0.05).Conclusions:Our initial result demonstrated reconstructive EVT with Willis covered stent provides a viable approach for selected symptomatic VADAs involving the intracranial and extracranial segments,which is similar to favorable results with SAC.However,an expanded clinical experiences and larger cohort studies are needed.
文摘Blood blister-like aneurysms(BBAs)are fragile and difficult to treat.However,the optimal treatment has yet to be determined.Pipeline embolization devices and Willis covered stent implementation are still controversial strategies for treating BBA.Herein,we report a case of recurrent BBA successfully treated with a Willis covered stent.A long-term follow-up angiography after the procedure indicated complete occlusion of the aneurysm.This case demonstrates the safety and efficacy of applying the Wills cover stent in the treatment of recurrent BBA after Pipeline implantation.
文摘Biliary fully covered self-expanding metal stents (FCSEMS) are now being used to treat several benign biliary conditions. Advantages include small predeployment and large postexpansion diameters in addition to an easy insertion technique. Lack of imbedding of the metal into the bile duct wall enables removability. In benign biliary strictures that usually require multiple procedures, despite the substantially higher cost of FCSEMS compared with plastic stents, the use of FCSEMS is offset by the reduced number of endoscopic retrograde cholangiopancreatography interventions required to achieve stricture resolution. In the same way, FCSEMS have also been employed to treat complex bile leaks, perforation and bleeding after endoscopic biliary sphincterotomy and as an aid to maintain permanent drainage tracts obtained by means of Endoscopic Ultrasound-guided biliary drainage. Good success rates have been achieved in all these conditions with an acceptable number of complications. FCSEMS were successfully removed in all patients. Comparative studies of FCSEMS and plastic stents are needed to demonstrate efficacy and cost-effectiveness
基金supported by the Project from Shanghai Natural Science Fund Project(Grant no.19ZR1449000)Training Program of Shanghai Tongji hospital(Grant no.GJPY1812 and ITJ(ZD)1907)+1 种基金Shanghai“Rising Stars of Medical Talent”Youth Development Program(Grant no.[2019]72)Program of Outstanding Young Scientists of Tongji Hospital of Tongji University no.HBRC1808。
文摘Background:To report the clinical results and experiences of endoleak management and postoperative surveillance following endovascular repair of internal carotid artery vascular diseases(ICAVDs)using Willis covered stents.METHODS:Seventy-three patients with ICAVD who received Willis covered stent implantation between November 2013 and September 2018 were retrospectively reviewed.The clinical data of endoleak management and postoperative surveillance were analyzed.RESULTS:Seventy-three cases with ICAVD,including 57 aneurysms,11 carotid-cavernous sinus fistulas(CCF),and 5 surgical injuries,were all successfully installed with covered stents.Total isolation of ICAVDs was achieved in 59 patients(80.8%),and endoleaks were observed in 14 patients(19.2%).Of the 14 patients with endoleaks,12 had type I endoleaks and 2 had type II;13 had aneurysms and one had CCF.10 patients with type I endoleaks received balloon dilatation,and 7 of them underwent a second stent-graft implantation after then.One patient with type II endoleak received embolization of the branch artery,and another one received follow-up observation.Endoleaks resolved in 6 patients and were minimal in 5 patients after balloon dilatation or the second stent implantation.During the follow-up period,minor endoleaks spontaneously resolved in 4 patients and minimal endoleaks were still demonstrated in 4 patients without enlargement of residual lumen and rupture.CONCLUSIONS:Endoleaks are the major complication after endovascular repair of ICAVDs and represent one of the limitations of this procedure.Improving the understanding and management of endoleaks can be beneficial in the clinical setting,including the popularization and application of this technique.