期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Power Control Based on State Space Strategies for Grid⁃Oriented Inverters with LCL Filters
1
作者 Chunyu Lu Wei Hua Mingjin Hu 《Journal of Harbin Institute of Technology(New Series)》 CAS 2022年第2期1-12,共12页
Through a third⁃order mathematical model of grid⁃oriented LCL⁃type converters,this paper analyzes the complicated dynamic characteristics and resonance problems which may influence the system stability.To realize acti... Through a third⁃order mathematical model of grid⁃oriented LCL⁃type converters,this paper analyzes the complicated dynamic characteristics and resonance problems which may influence the system stability.To realize active damping for LCL filters and improve dynamic performance of current regulators,a state space current PI controller is proposed whose parameters can be tuned based on the polynomial equations approach.An extended state observer is integrated with the regulation scheme,where additional sensors are not necessary in contrast with conventional active damping strategies.Synchronous reference frame PLL(SRF⁃PLL)equipped with filter technology is proposed for grid voltage disturbance suppression.This method is then applied to establish a double⁃closed⁃loop power regulator that demonstrates improved performance compared with other controllers.The simulation results are displayed to illustrate the efficiency of the regulation methods. 展开更多
关键词 LCL⁃type grid⁃oriented converters state space current control SRF⁃PLL closed loop power control
下载PDF
Improved Model Predictive Direct Power Control of Grid Side Converter in Weak Grid Using Kalman Filter and DSOGI 被引量:4
2
作者 Liang Chen Heng Nian Yunyang Xu 《Chinese Journal of Electrical Engineering》 CSCD 2019年第4期22-32,共11页
When grid side converter(GSC)is connected to weak grid,the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance.This issue is not of wide concern... When grid side converter(GSC)is connected to weak grid,the small signal instability can happen due to terminal characteristics of the GSC that are incompatible with the grid impedance.This issue is not of wide concern in previous studies of direct power control(DPC)of GSC.By small signal analysis,it is shown that the impedance characteristic of the conventional direct power control GSC is not compatible with the inductive grid impedance in weak grid due to its constant power load behavior.To solve the problem,instead of feeding the DPC controller with direct measured voltage and current,a Kalman filter(KF)is used to obtain filtered output current and a double second-order generalized integrator(DSOGI)is used to obtain filtered voltage at the point of common coupling(PCC).These strategies change the impedance characteristic of the GSC dramatically and make it suitable to operate in weak grid where SCR is 2,while the rapid power response is preserved.The proposed strategy is verified through simulation and controller hardware in loop(CHIL)tests. 展开更多
关键词 Direct power control weak grid grid side converter STABILITY
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部