期刊文献+
共找到412篇文章
< 1 2 21 >
每页显示 20 50 100
Comprehensive Evaluation of Distributed PV Grid-Connected Based on Combined Weighting Weights and TOPSIS-RSR Method
1
作者 Yue Yang Jiarui Zheng +2 位作者 Long Cheng Yongnan Zhu Hao Wu 《Energy Engineering》 EI 2024年第3期703-728,共26页
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj... To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified. 展开更多
关键词 Distributed PV grid-connected comprehensive evaluation evaluation indicator system combined subjective and objective empowerment TOPSIS-RSR method
下载PDF
Dynamic phasor-based hybrid simulation for multi-inverter grid-connected system
2
作者 Peng Yang Qian Li +2 位作者 Junyu Zhao Juanjuan Lu Yunfei Xu 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期197-204,共8页
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient... To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation. 展开更多
关键词 Multi-inverter grid-connected system Electromagnetic transient Dynamic phasor Hybrid simulation
下载PDF
Robust Dichotomy Solution-Based Model Predictive Control for the Grid-Connected Inverters with Disturbance Observer 被引量:5
3
作者 Huanyue Liao Xin Zhang Zhijun Ma 《CES Transactions on Electrical Machines and Systems》 CSCD 2021年第2期81-89,共9页
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima... This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach. 展开更多
关键词 Dichotomy solution-based model predictive control(DS-MPC) three-phase grid-connected inverter(GCI) weak grid voltage vector dichotomy
下载PDF
Grid-connected inverter for wind power generation system 被引量:1
4
作者 杨勇 阮毅 +2 位作者 沈欢庆 汤燕燕 杨影 《Journal of Shanghai University(English Edition)》 CAS 2009年第1期51-56,共6页
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T... In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response. 展开更多
关键词 grid-connected inverter space vector pulse width modulation (SVPWM) grid voltage vector-oriented power factor
下载PDF
An Improved Repetitive Control Strategy for LCL Grid-Connected Inverter
5
作者 Ning He Chenlu Song +1 位作者 Feng Gao Cheng Qian 《Journal of Beijing Institute of Technology》 EI CAS 2022年第4期391-400,共10页
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of... This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved. 展开更多
关键词 grid-connected inverter LCL filter harmonic suppression repetitive control
下载PDF
A Modified-Simplified MPPT Technique for Three-Phase Single-State Grid-Connected PV Systems
6
作者 Anuchit Aurairat Boonyang Plangklang 《Computers, Materials & Continua》 SCIE EI 2022年第8期2375-2395,共21页
Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focus... Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1. 展开更多
关键词 Single-state grid-connected model predictive control maximum power point estimation perturbation and observation
下载PDF
Dual-loop Control Strategy for Grid-connected Inverter with LCL Filter
7
作者 Qiubo Peng Hongbin Pan +1 位作者 Yong Liu Lidan Xiang 《Energy and Power Engineering》 2013年第4期97-101,共5页
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin... As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results. 展开更多
关键词 Virtual DAMPING LCL Filter THREE-PHASE grid-connected Inverter DECOUPLING Control
下载PDF
Bi-Level Energy Management Model of Grid-Connected Microgrid Community
8
作者 Haibin Cao Houqi Dong +3 位作者 Yongjie Ren Yuqing Wang Na Li Ming Zeng 《Energy Engineering》 EI 2022年第3期965-984,共20页
As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro... As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro-Grid Community(MGC).In order to reduce the operation and maintenance costs of a single micro grid and reduce the adverse effects caused by unnecessary energy interaction between the micro grid and the main grid while improving the overall economic benefits of the micro grid community,this paper proposes a bi-level energy management model with the optimization goal of maximizing the social welfare of the micro grid community and minimizing the total electricity cost of a single micro grid.The lower-level model optimizes the output of each equipment unit in the system and the exchange power between the system and the external grid with the goal of minimizing the operating cost of each microgrid.The upper-level model optimizes the goal ofmaximizing the socialwelfare of themicrogrid.Taking amicrogrid community with four microgrids as an example,the simulation analysis shows that the proposed optimization model is beneficial to reduce the operating cost of a single microgrid,improve the overall revenue of the microgrid community,and reduce the power interaction pressure on the main grid. 展开更多
关键词 Renewable energy grid-connected micro-grid community bi-level energy management model
下载PDF
Forecast of Power Generation for Grid-Connected Photo-voltaic System Based on Grey Theory and Verification Model
9
作者 Ying-zi Li Jin-cang Niu Li Li 《Energy and Power Engineering》 2013年第4期177-181,共5页
Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected... Being photovoltaic power generation affected by radiation strength, wind speed, clouds cover and environment temperature, the generating in each moment is fluctuating. The operational characteristics of grid-connected PV systems are coincided with gray theory application conditions. A gray theory model has been applied in short-term forecast of grid-connected photovoltaic system. The verification model of the probability of small error will help to check the accuracy of the gray forecast results. The calculated result shows that the ?model accuracy has been greatly enhanced. 展开更多
关键词 FORECAST of Power Generation grid-connected Photovoltaic SYSTEM Data DISCRETIZATION GREEDY Algorithm Continuous Attributes ROUGH Sets
下载PDF
Quasi-Z Source Inverter Control of PV Grid-Connected Based on Fuzzy PCI
10
作者 Tao Hou Chen-Yang Zhang Hong-Xia Niu 《Journal of Electronic Science and Technology》 CAS CSCD 2021年第3期274-286,共13页
The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the powe... The photovoltaic grid-connected inverter is an important interface between the photovoltaic power generation system and power grid.Its high-quality operation is directly related to the output power quality of the power grid.In order to further optimize the control effect of the quasi-Z source grid-connected photovoltaic inverter,a fuzzy proportional complex integral control(PCI)method is proposed for the current internal loop control.This method can eliminate the steady-state error,and has the characteristic of zero steady-state error adjustment for the AC disturbance signal of a specific frequency.The inductance-capacitance-inductance(LCL)filter is adopted in the grid-connected circuit,and the feedback capacitive current is taken as the control variable of the inner loop to form the active damping control method,which can not only effectively suppress the resonance of the LCL circuit,but also significantly inhibit the high-order harmonics in the grid-connected current.Finally,a system simulation model is built in MATLAB/Simulink to verify the superiority and effectiveness of the proposed method. 展开更多
关键词 Frequency of harmonic distortion fuzzy proportional complex integral inductance-capacitance-inductance(LCL)filtering circuit photovoltaic grid-connection quasi-Z source inverter
下载PDF
Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal
11
作者 P. W. Tavares H. D. Ndiath +3 位作者 M. Kane B. Mbow A. T. Niang I. Youm 《International Journal of Clean Coal and Energy》 2020年第1期1-14,共14页
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura... This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection. 展开更多
关键词 Analysis of the PERFORMANCES The PHOTOVOLTAIC SOLAR Energy grid-connected PV System Senegal
下载PDF
FCS-MPC Strategy for PV Grid-Connected Inverter Based on MLD Model
12
作者 Xiaojuan Lu Qingbo Zhang 《Energy Engineering》 EI 2021年第6期1729-1740,共12页
In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-conn... In the process of grid-connected photovoltaic power generation,there are high requirements for the quality of the power that the inverter breaks into the grid.In this work,to improve the power quality of the grid-connected inverter into the grid,and the output of the system can meet the grid-connected requirements more quickly and accurately,we exhibit an approach toward establishing a mixed logical dynamical(MLD)model where logic variables were introduced to switch dynamics of the single-phase photovoltaic inverters.Besides,based on the model,our recent efforts in studying the finite control set model predictive control(FCS-MPC)and devising the output current full state observer are exciting for several advantages,including effectively avoiding the problem of the mixed-integer quadratic programming(MIQP),lowering the THD value of the output current of the inverter circuit,improving the quality of the power that the inverter breaks into the grid,and realizing the current output and the grid voltage same frequency and phase to meet grid connection requirements.Finally,the effectiveness of the mentioned methods is verified by MATLAB/Simulink simulation. 展开更多
关键词 Photovoltaic grid-connected inverter hybrid logic dynamic model finite control set model predictive control full state observer
下载PDF
Influence of Control Modes of Grid-Connected Solar Photovoltaic Generation on Grid Power Flow
13
作者 Zakaria Al-Omari 《Engineering(科研)》 2014年第13期914-922,共9页
Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but... Integration of Solar Photovoltaic (PV) generation into an existing distribution system has many impacts on the system, with the power flow being one of the major issues. This impact is not generic for any network, but it may manifest itself either positively or negatively, depending on the grid configuration, interface control modes, operation mode, and load profile. Grid-connected PV systems have three control options of the local voltage controller of the interface DC-AC converter. These control modes are Power Factor control, voltage control, and Droop Voltage control. This paper aims at evaluating and comparing the impacts of those control modes on the grid power flow. A set of evaluation criteria and indices is defined and mathematically formulated. Based on the requirements of the used program (Power Factory Dig Silent V14.1.3), a computation plan (algorithm) has been proposed. The algorithm has been applied to a typical weak network and a wide range of simulations has been carried out. Simulation results have been thoroughly discussed and important findings have been concluded. 展开更多
关键词 grid-connected PV Control MODES POWER Flow POWER FACTORY DIG SILENT Software
下载PDF
A Simulation Research on the Grid-Connected Control Technology of Single-Phase Inverters Based on MATLAB
14
作者 Jinjie Chen 《Journal of Electronic Research and Application》 2022年第4期7-12,共6页
This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-... This paper primarily discusses the main circuit of single-phase inverter circuits.It begins by introducing the research context and the significance of the subject,then discusses the topology of grid-connected single-phase inverter circuits,continues by discussing the control strategy for grid-connected single-phase inverter circuits,realizes a sinusoidal pulse width modulation(SPWM)signal generation circuit and an inverse control algorithm program,and finally ensures good output waveform and fast dynamic response.In view of the hysteresis feature of the grid voltage’s synchronous signal sampling circuit,the acquisition function in digital signal processing(DSP)control chips is applied,and the reasons for the hysteresis phenomenon are thoroughly investigated.The reliability of the SPWM control algorithm is revealed through the results. 展开更多
关键词 Solar energy Photovoltaic power generation grid-connected inverter circuit MATLAB simulation
下载PDF
Performance Assessment of a Real PV System Connected to a Low-Voltage Grid
15
作者 Gaber Magdy Mostafa Metwally +1 位作者 Adel A.Elbaset Esam Zaki 《Energy Engineering》 EI 2024年第1期13-26,共14页
The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Th... The generation of photovoltaic(PV)solar energy is increasing continuously because it is renewable,unlimited,and clean energy.In the past,generation systems depended on non-renewable sources such as oil,coal,and gas.Therefore,this paper assesses the performance of a 51 kW PV solar power plant connected to a low-voltage grid to feed an administrative building in the 6th of October City,Egypt.The performance analysis of the considered grid-connected PV system is carried out using power system simulator for Engineering(PSS/E)software.Where the PSS/E program,monitors and uses the power analyzer that displays the parameters and measures some parameters such as current,voltage,total power,power factor,frequency,and current and voltage harmonics,the used inverter from the type of grid inverter for the considered system.The results conclude that when the maximum solar radiation is reached,the maximum current can be obtained from the solar panels,thus obtaining the maximum power and power factor.Decreasing total voltage harmonic distortion,a current harmonic distortion within permissible limits using active harmonic distortion because this type is fast in processing up to 300 microseconds.The connection between solar stations and the national grid makes the system more efficient. 展开更多
关键词 Low-voltage grid photovoltaic(PV)system total harmonic distortion grid-connected PV system
下载PDF
车用电动空调压缩机ECU测试方法研究
16
作者 丛宪冬 李秋实 《自动化与仪表》 2024年第1期160-164,共5页
基于目前车用电动空调压缩机ECU测试项繁多、工序复杂以及无法针对性测试等问题,设计了一套结构合理、操作便捷、自动化水平较高的控制器测试方案。方案涵盖参数标定、过欠压保护、负载模拟和通讯功能等多个模块的测试,并搭建测试台进... 基于目前车用电动空调压缩机ECU测试项繁多、工序复杂以及无法针对性测试等问题,设计了一套结构合理、操作便捷、自动化水平较高的控制器测试方案。方案涵盖参数标定、过欠压保护、负载模拟和通讯功能等多个模块的测试,并搭建测试台进行硬件在环测试。最后对测试结果分析,表明测试方案能满足某型号ECU性能测试需求,测试系统稳定可靠。 展开更多
关键词 空调压缩机 电控单元 测试方案 硬件在环
下载PDF
汽车中控饰板刀口抽芯双色注射模设计
17
作者 刘益环 童金 《模具制造》 2024年第6期5-8,共4页
针对一款车型的中控饰板壳体,设计了一副活动刀口抽芯在同一个模腔内实现切换双色的一种新型双色注射模,该类型的双色模具采用双色注塑腔内切换机构,第一射与第二射相交之间设计一个抽芯滑块作为一个刀口开关阀门,用于控制以下所述第一... 针对一款车型的中控饰板壳体,设计了一副活动刀口抽芯在同一个模腔内实现切换双色的一种新型双色注射模,该类型的双色模具采用双色注塑腔内切换机构,第一射与第二射相交之间设计一个抽芯滑块作为一个刀口开关阀门,用于控制以下所述第一注射位置与第二注射位置之间切换,从而相比与传统的旋转式双色模具质量更稳定,生产成本更低,产品品质合格率更高。通过实际验证,结果表明,该种滑块刀口抽芯式双色模具运行稳定可靠,满足生产要求,实现提高了生产效率并降低了成本。 展开更多
关键词 汽车中控饰板 双色模具 模内抽芯 滑块抽芯
下载PDF
基于奥密克戎变异株的新冠肺炎疫情期间综合医院口腔门、急诊感控策略
18
作者 张宇 王淑敏 +2 位作者 王振宁 薛蕊 徐璐璐 《口腔颌面修复学杂志》 2023年第2期132-137,共6页
新冠肺炎疫情的爆发,给综合医院口腔门、急诊的管理和诊疗带来了极大挑战。并且,随着新冠病毒的不断变异,出现了多个传染性和致病性强的变异株。其中奥密克戎变异株具有传播速度快、传染性强、隐匿性强、免疫逃避能力强等特点,给口腔门... 新冠肺炎疫情的爆发,给综合医院口腔门、急诊的管理和诊疗带来了极大挑战。并且,随着新冠病毒的不断变异,出现了多个传染性和致病性强的变异株。其中奥密克戎变异株具有传播速度快、传染性强、隐匿性强、免疫逃避能力强等特点,给口腔门、急诊感控工作带来了前所未有的考验。本文依据国家卫生健康委员会颁发的相关规范标准,紧密结合疫情防控最新相关规定以及近期疫情情况,参考疫情爆发以来部分医疗机构的感控策略,结合对基于奥密克戎变异株的新冠肺炎疫情的特点,综合医院口腔门、急诊诊疗面临挑战,以及感控策略等方面进行阐述,希望为今后类似疫情发生时口腔门、急诊的应对和相关的临床研究提供参考。 展开更多
关键词 新冠肺炎 奥密克戎变异株 口腔门、急诊 感染控制
下载PDF
Inertial PLL of Grid-connected Converter for Fast Frequency Support 被引量:2
19
作者 Xiang Guo Donghai Zhu +3 位作者 Jiabing Hu Xudong Zou Yong Kang Josep M.Guerrero 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2023年第4期1594-1599,共6页
Frequency support capability for the grid-connected converter(GCC)is one of the basic safeguards for the stability of renewables-dominated power systems.In this paper,analogous to the motion equation of a synchronous ... Frequency support capability for the grid-connected converter(GCC)is one of the basic safeguards for the stability of renewables-dominated power systems.In this paper,analogous to the motion equation of a synchronous generator(SG),an inertial phase-locked loop(iPLL)is proposed for GCC to achieve fast frequency support.The iPLL introduces the inertial and damping loops into the classic PLL structure to emulate the natural frequency regulation characteristics of a SG.Compared with the existing methods,the iPLL has a faster frequency response and is simpler in design and implementation.Finally,the proposed iPLL method is validated by experiments.Index Terms-Frequency support,grid-connected converter,inertial phase-locked loop(iPLL),synchronous generation(SG). 展开更多
关键词 Frequency support grid-connected converter inertial phase-locked loop(iPLL) synchronous generation(SG).
原文传递
渤海油田过电缆封隔器无法解封相关复杂情况处理方法 被引量:2
20
作者 陈曦 侯辉 +1 位作者 尹科飞 姚永俊 《石化技术》 CAS 2023年第2期70-72,共3页
为保证油井的完整性安全,目前渤海油田生产管柱普遍使用过电缆封隔器、放气阀和井下安全阀组成井的一级二级屏障。一般情况下,过电缆封隔器在管柱过提18~19t时解封,但个别情况偶尔会发生无法正常解封的情况,产生一系列复杂作业问题,包... 为保证油井的完整性安全,目前渤海油田生产管柱普遍使用过电缆封隔器、放气阀和井下安全阀组成井的一级二级屏障。一般情况下,过电缆封隔器在管柱过提18~19t时解封,但个别情况偶尔会发生无法正常解封的情况,产生一系列复杂作业问题,包括无循环通道、井涌、管柱异常上顶、产生绳类或小件落鱼、复杂打捞等问题。结合渤海修井作业实际案例,对过电缆封隔器遇卡所产生的复杂问题进行全面分析、归纳,并提出解决思路。 展开更多
关键词 过电缆封隔器 修井作业 井控 打捞
下载PDF