期刊文献+
共找到2,108篇文章
< 1 2 106 >
每页显示 20 50 100
Comprehensive Evaluation of Distributed PV Grid-Connected Based on Combined Weighting Weights and TOPSIS-RSR Method
1
作者 Yue Yang Jiarui Zheng +2 位作者 Long Cheng Yongnan Zhu Hao Wu 《Energy Engineering》 EI 2024年第3期703-728,共26页
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj... To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified. 展开更多
关键词 distributed PV grid-connected comprehensive evaluation evaluation indicator system combined subjective and objective empowerment TOPSIS-RSR method
下载PDF
Research on Scheduling Strategy of Flexible Interconnection Distribution Network Considering Distributed Photovoltaic and Hydrogen Energy Storage
2
作者 Yang Li Jianjun Zhao +2 位作者 Xiaolong Yang He Wang Yuyan Wang 《Energy Engineering》 EI 2024年第5期1263-1289,共27页
Distributed photovoltaic(PV)is one of the important power sources for building a new power system with new energy as the main body.The rapid development of distributed PV has brought new challenges to the operation of... Distributed photovoltaic(PV)is one of the important power sources for building a new power system with new energy as the main body.The rapid development of distributed PV has brought new challenges to the operation of distribution networks.In order to improve the absorption ability of large-scale distributed PV access to the distribution network,the AC/DC hybrid distribution network is constructed based on flexible interconnection technology,and a coordinated scheduling strategy model of hydrogen energy storage(HS)and distributed PV is established.Firstly,the mathematical model of distributed PV and HS system is established,and a comprehensive energy storage system combining seasonal hydrogen energy storage(SHS)and battery(BT)is proposed.Then,a flexible interconnected distribution network scheduling optimization model is established to minimize the total active power loss,voltage deviation and system operating cost.Finally,simulation analysis is carried out on the improved IEEE33 node,the NSGA-II algorithm is used to solve specific examples,and the optimal scheduling results of the comprehensive economy and power quality of the distribution network are obtained.Compared with the method that does not consider HS and flexible interconnection technology,the network loss and voltage deviation of this method are lower,and the total system cost can be reduced by 3.55%,which verifies the effectiveness of the proposed method. 展开更多
关键词 Seasonal hydrogen storage flexible interconnection AC/DC distribution network photovoltaic absorption scheduling strategy
下载PDF
Comprehensive Benefit Evaluation of SZ Distributed Photovoltaic Power Generation Project Based on AHP-Matter-Element Extension Model
3
作者 Shuli Jing 《Journal of Electronic Research and Application》 2024年第1期60-68,共9页
With the introduction of the“dual carbon goals,”there has been a robust development of distributed photovoltaic power generation projects in the promotion of their construction.As part of this initiative,a comprehen... With the introduction of the“dual carbon goals,”there has been a robust development of distributed photovoltaic power generation projects in the promotion of their construction.As part of this initiative,a comprehensive and systematic analysis has been conducted to study the overall benefits of photovoltaic power generation projects.The evaluation process encompasses economic,technical,environmental,and social aspects,providing corresponding analysis methods and data references.Furthermore,targeted countermeasures and suggestions are proposed,signifying the research’s importance for the construction and development of subsequent distributed photovoltaic power generation projects. 展开更多
关键词 distributed photovoltaic power generation Comprehensive benefits EVALUATION
下载PDF
Energy Loss Analysis of Distributed Rooftop Photovoltaics in Industrial Parks
4
作者 Yu Xiao Kai Li +2 位作者 HongqiaoHuang Haibo Tan Hua Li 《Energy Engineering》 EI 2023年第2期511-527,共17页
The analysis of the loss of distributed photovoltaic power generation systems involves the interests of energy users,energy-saving service companies,and power grid companies,so it has always been the focus of the indu... The analysis of the loss of distributed photovoltaic power generation systems involves the interests of energy users,energy-saving service companies,and power grid companies,so it has always been the focus of the industry and society in some manner or another.However,the related analysis for an actual case that considers different cooperative corporations’benefits is lacking in the presently available literature.This paper takes the distributed rooftop photovoltaic power generation project in an industrial park as the object,studies the analysis and calculation methods of line loss and transformer loss,analyzes the change of transformer loss under different temperatures and different load rates,and compares the data and trend of electricity consumption and power generation in industrial parks before and after the photovoltaic operation.This paper explores and practices the analysis method of the operating loss of distributed photovoltaic power generation and provides an essential reference for the benefit analysis and investment cost estimation of distributed photovoltaic power generation systems in industrial parks.The analyzed results reveal that the change loss is stable after the photovoltaic is connected,and there is no additional transformer loss.And before and after the photovoltaic system installation,there was no significant change in the total monthly data difference between the total meter and the sub-meter. 展开更多
关键词 distributed photovoltaic generation line loss transformer loss power generation
下载PDF
Coordinated planning for flexible interconnection and energy storage system in low-voltage distribution networks to improve the accommodation capacity of photovoltaic 被引量:2
5
作者 Jiaguo Li Lu Zhang +1 位作者 Bo Zhang Wei Tang 《Global Energy Interconnection》 EI CSCD 2023年第6期700-713,共14页
The increasing proportion of distributed photovoltaics(DPVs)and electric vehicle charging stations in low-voltage distribution networks(LVDNs)has resulted in challenges such as distribution transformer overloads and v... The increasing proportion of distributed photovoltaics(DPVs)and electric vehicle charging stations in low-voltage distribution networks(LVDNs)has resulted in challenges such as distribution transformer overloads and voltage violations.To address these problems,we propose a coordinated planning method for flexible interconnections and energy storage systems(ESSs)to improve the accommodation capacity of DPVs.First,the power-transfer characteristics of flexible interconnection and ESSs are analyzed.The equipment costs of the voltage source converters(VSCs)and ESSs are also analyzed comprehensively,considering the differences in installation and maintenance costs for different installation locations.Second,a bilevel programming model is established to minimize the annual comprehensive cost and yearly total PV curtailment capacity.Within this framework,the upper-level model optimizes the installation locations and capacities of the VSCs and ESSs,whereas the lower-level model optimizes the operating power of the VSCs and ESSs.The proposed model is solved using a non-dominated sorting genetic algorithm with an elite strategy(NSGA-II).The effectiveness of the proposed planning method is validated through an actual LVDN scenario,which demonstrates its advantages in enhancing PV accommodation capacity.In addition,the economic benefits of various planning schemes with different flexible interconnection topologies and different PV grid-connected forms are quantitatively analyzed,demonstrating the adaptability of the proposed coordinated planning method. 展开更多
关键词 Low-voltage distribution network photovoltaic accommodation Flexible interconnection Energy storage system Bilevel programming
下载PDF
Design scheme for fast charging station for electric vehicles with distributed photovoltaic power generation 被引量:12
6
作者 Jing Zhang Chang Liu +5 位作者 Ruiming Yuan Taoyong Li Kang Li Bin Li Jianxiang Li Zhenyu Jiang 《Global Energy Interconnection》 2019年第2期150-159,共10页
The demand for fast charging is increasing owing to the rapid expansion of the market for electric vehicles. In addition, the power generation technology for distributed photovoltaic has matured. This paper presents a... The demand for fast charging is increasing owing to the rapid expansion of the market for electric vehicles. In addition, the power generation technology for distributed photovoltaic has matured. This paper presents a design scheme for a fast charging station for electric vehicles equipped with distributed photovoltaic power generation system taking the area with certain conditions in Beijing as an example construction site. The technical indexes and equipment lectotype covering the general framework and subsystems of the charging station are determined by analyzing the charging service demand of fast charging stations. In this study, the layout of the station is developed and the operation benefits of the station is analyzed. The design scheme realizes the design objective of "rationalization, modularization and intelligentization" of the fast charging station and can be used as reference for the construction of a fast charging network in urban area. 展开更多
关键词 Electric VEHICLE Fast CHARGING STATION CHARGING DEMAND Design scheme distributed photovoltaic
下载PDF
Large-Scale Distributed Photovoltaic Power Dispatching and Operation Management Review 被引量:2
7
作者 Nan Zhang Yuefeng Wang +3 位作者 Yuehui Huang Dewei Liu Yunfeng Gao Haifeng Li 《Journal of Power and Energy Engineering》 2015年第4期326-331,共6页
Distributed photovoltaic power (PV) is the main development model of distributed generation. It is necessary to research on dispatching and operation management with large-scale distributed PV connected. This paper an... Distributed photovoltaic power (PV) is the main development model of distributed generation. It is necessary to research on dispatching and operation management with large-scale distributed PV connected. This paper analyzes development status, technical requirement and dispatching and operation management situation of distributed PV in Germany and China. Then introduce the preparation of distributed PV dispatching and operation management criterion. Through summarizing the experiences and lessons of large-scale distributed PV development in Germany, it gives advice to the development of distributed PV dispatching and operation management in China. 展开更多
关键词 distributed photovoltaic Power grid-connected DISPATCHING and Operation PRIORITY CONSUMPTION
下载PDF
Security Assessment of Distribution System with Distributed Photovoltaic 被引量:1
8
作者 Weiping Zhu Zhicheng Wang +1 位作者 Xiaodong Yuan Ruonan Fan 《Journal of Power and Energy Engineering》 2015年第4期250-261,共12页
In order to evaluate the safe and stable operation of distribution network with the distributed photovoltaic (PV), the?security of distribution network is researched. On the basis of electricity supply security, volta... In order to evaluate the safe and stable operation of distribution network with the distributed photovoltaic (PV), the?security of distribution network is researched. On the basis of electricity supply security, voltage quality and network losses,?the index system of static security is established. The paper simulates the uncertainty and random characteristics of PV by OpenDSS. The typical scenes that PV accessed to the distribution network are designed.?The paper summarizes the results of voltage fluctuation and network losses and uses indices to quantify it under different scenes. Based on the index system, the paper proposes some recommendations on PV permeability, interconnected locations, dispersion degrees and power factors when the distributed PV accessed to the distribution network. 展开更多
关键词 SECURITY ASSESSMENT of distributION System with distributed photovoltaic
下载PDF
Convex decomposition of concave clouds for the ultra-short-term power prediction of distributed photovoltaic system 被引量:1
9
作者 蔡世波 Tong Jianjun +3 位作者 Bao Guanjun Pan Guobing Zhang Libin Xu Fang 《High Technology Letters》 EI CAS 2016年第3期305-312,共8页
Concave clouds will cause miscalculation by the power prediction model based on cloud features for distributed photovoltaic( PV) plant. The algorithm for decomposing concave cloud into convex images is proposed. Adopt... Concave clouds will cause miscalculation by the power prediction model based on cloud features for distributed photovoltaic( PV) plant. The algorithm for decomposing concave cloud into convex images is proposed. Adopting minimum polygonal approximation( MPP) to demonstrate the contour of concave cloud,cloud features are described and the subdivision lines of convex decomposition for the concave clouds are determined by the centroid point scattering model and centroid angle function,which realizes the convex decomposition of concave cloud. The result of MATLAB simulation indicates that the proposed algorithm can accurately detect cloud contour corners and recognize the concave points. The proposed decomposition algorithm has advantages of less time complexity and decomposition part numbers compared to traditional algorithms. So the established model can make the convex decomposition of complex concave clouds completely and quickly,which is available for the existing prediction algorithm for the ultra-short-term power output of distributed PV system based on the cloud features. 展开更多
关键词 distributed photovoltaic(PV) system cloud features MODEL CENTROID point scattering MODEL CONVEX decomposition
下载PDF
A Combined Solar Photovoltaic Distributed Energy Source Appliance
10
作者 Himanshu Dehra 《Natural Resources》 2011年第2期75-86,共12页
The paper has analysed the state-of-art technology for a solar photovoltaic distributed energy source appliance. The success of implementation of photovoltaic (PV) power project is increased when PV module system is i... The paper has analysed the state-of-art technology for a solar photovoltaic distributed energy source appliance. The success of implementation of photovoltaic (PV) power project is increased when PV module system is integrated with building design process and is used as multi purpose appliance for use with building elements. The improvement in overall system efficiency of building integrated PV modules embedded in building fa?ade is achieved by minimizing and capturing energy losses. A novel solar energy utilisation technology for generation of electric and thermal power is presented by integration of ventilation and solar photovoltaic device with the heating, ventilating and air conditioning (HVAC) system. The testing appliance named as photovoltaic duct wall was a wooden frame assembly of double wall with air ventilation: two adjacent glass coated PV modules, air column, plywood board filled with polystyrene and dampers. The measurement data is collected from various sensors to read measurements of solar intensity, ambient air temperature, room air temperature, electric power, surface temperatures of PV modules and plywood board, air velocities and air temperatures in the air column. The enhancement in the air velocity of the air column is fulfilled with an exhaust fan fixed in an outdoor room. The simulation model is used to perform the two dimensional energy analyses with applied one dimensional solution of steady state heat conduction equations. The bases of simulation model are conjugating energy travel paths with network boundary conditions of convection, radiation exchange, heat storage ca- pacity, thermal storage capacity and heat transport. 展开更多
关键词 HVAC ENERGY SOURCE ENERGY APPLIANCE ENERGY distribution photovoltaic DUCT
下载PDF
Evaluation of the Performances of the First Grid-Connected Photovoltaic System in Sénégal
11
作者 P. W. Tavares H. D. Ndiath +3 位作者 M. Kane B. Mbow A. T. Niang I. Youm 《International Journal of Clean Coal and Energy》 2020年第1期1-14,共14页
This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugura... This document presents the evaluation and the monitoring of the performances of the first grid-connected photovoltaic system installed in the Center of Studies and Researches on the Renewable Energies (CERER) inaugurated on December 4th, 2012 by the governmental authorities of Senegal and Tenerife. This mini power plant of 3.15 kWc is a perfect example of the political will of the government which is to reduce the production cost of the electricity, with the diversification of the sources of production, and the greater use of the other sources such as the natural gas, the coal, the renewable energies. The evaluation of the performances of the installation is realized by using the indicators of efficiency and performance as the photovoltaic surface yield, the ratio of photovoltaic performance, the photovoltaic specific yield, and the losses of captures. The obtained results show that a big part of the energy shone during the period of observation was not able to be used further to circumstances such as the losses of conductivity, the heat losses or for example the defects on components. The analysis also shows that a large part of the produced energy is not injected because of the dilapidation of the network, the defects of landing but especially one disjunction sees frequently at the level of the point of injection. 展开更多
关键词 Analysis of the PERFORMANCES The photovoltaic SOLAR Energy grid-connected PV System Senegal
下载PDF
The analysis of distributed photovoltaic access system schemes
12
作者 Yuting Pan Yuchen Chen +1 位作者 Zhiqiang Yuan Bo Liu 《International English Education Research》 2014年第12期70-73,共4页
关键词 光伏发电 接入系统 分布式 经济效益 电力系统 优化选择 功率损失 光伏系统
下载PDF
Analysis and Power Quality Improvement in Hybrid Distributed Generation System with Utilization of Unified Power Quality Conditioner
13
作者 Noor Zanib Munira Batool +4 位作者 Saleem Riaz Farkhanda Afzal Sufian Munawar Ibtisam Daqqa Najma Saleem 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1105-1136,共32页
This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a u... This paper presents a comprehensive study that includes the sizing and power flow by series and parallel inverters in a distributed generation system(DGs)that integrates the system of hybrid wind photovoltaic with a unified power quality conditioner(UPQC).In addition to supplying active power to the utility grid,the system of hybrid wind photovoltaic functions as a UPQC,compensating reactive power and suppressing the harmonic load currents.Additionally,the load is supplied with harmonic-free,balanced and regulated output voltages.Since PVWind-UPQC is established on a dual compensation scheme,the series inverter works like a sinusoidal current source,while the parallel inverter works like a sinusoidal voltage source.Consequently,a smooth alteration from interconnected operating modes to island operating modes and vice versa can be achieved without load voltage transients.Since PV-Wind-UPQC inverters handle the energy generated through the hybrid wind photovoltaic system and the energy demanded through the load,the converters should be sized cautiously.A detailed study of the flow of power via the PV-Wind-UPQC is imperative to gain a complete understanding of the system operation and the proper design of the converters.Thus,curves that allow the sizing of the power converters according to the power flow via the converters are presented and discussed.Simulation results are presented to assess both steady state and dynamic performances of the grid connected hybrid system of PV-Wind-UPQC.This investigation is verified by simulating and analyzing the results with Matlab/Simulink. 展开更多
关键词 photovoltaic wind turbine unified power quality conditioner power flow distributed generation system
下载PDF
Optimization of the Placement and Size of Photovoltaic Source
14
作者 Maawiya Ould Sidi Mustafa Mosbah Rabie Zine 《Computers, Materials & Continua》 SCIE EI 2023年第1期1855-1870,共16页
This paper presents a new optimization study of the placement and size of a photovoltaic source(PVS)in a distribution grid,based on annual records of meteorological parameters(irradiance,temperature).Based on the reco... This paper presents a new optimization study of the placement and size of a photovoltaic source(PVS)in a distribution grid,based on annual records of meteorological parameters(irradiance,temperature).Based on the recorded data,the production output as well as the daily average power(24-h vector)of the PVS is extracted over the year.When a power vector is available,it can be used as an input when searching for the optimal size of the PVS.This allows to take into account the constraint of the variation of the power generated by this source considering the variation of the power consumed by the electrical loads during the whole day.A multi-objective fitness function has been considered.The latter minimizes the active losses and maximizes the voltage stability index during the day,while considering the constraints of the system,that is,the security,technical,geographical,and meteorological constraints.This problem was solved using the Non-dominated Sorting Genetic Algorithm NSGA-II optimization technique under MATLAB 2021.It was applied to the distribution network of Ghardaïa of 59 nodes. 展开更多
关键词 Electric distribution network intermittent generation photovoltaic source multi-objective optimization active losses profile voltage stability index profile
下载PDF
Maximum Power Tracking of Photovoltaic Modules Based on Fuzzy Logic Employing Four-Phase Intervaled Boost Converter
15
作者 Beatriz Leitao Wolia Costa +1 位作者 Fabricio Brito Luis Tomaselli 《Journal of Power and Energy Engineering》 2023年第4期17-38,共22页
Currently, there are significant investments in the study of distributed generation, including solar energy by the photovoltaic conversion method. Basically, a cell directly converts solar energy to electricity. For t... Currently, there are significant investments in the study of distributed generation, including solar energy by the photovoltaic conversion method. Basically, a cell directly converts solar energy to electricity. For this, static converters are required. However, relevant issues arise in this process: point of maximum efficiency of module generation, strategy of control of the flow of energy to the network. The aim of this work is to monitor the main variables of a photovoltaic system, specifically the voltage and current module and their derivates. The goal is to implement the maximum power tracking technique using Fuzzy logic. In addition, the energy provided by the cell will be employed in an inverter stage that can operate as an active filter, voltage regulator, or generator of reactive and active power. The feasibility of using Fuzzy logic will also be studied. The first stage of this work involves parameterization and simulation of photovoltaic modules. The initial study examines the compatibility of a commercial module and its catalog data with the results of simulation. The simulated I-V characteristics show almost identical results to the catalog data. In sequence, a boost or lift DC-DC converter is employed to emulate variable load for maximum power transfer. 展开更多
关键词 distributed Generation CONVERTERS photovoltaic Fuzzy
下载PDF
Plant Community Survey of National Photovoltaic and Energy Storage Empirical Experiment Platform(Daqing Base)
16
作者 Yang WANG Naipeng REN +2 位作者 Siyu LI Xiangping LIU Shanmin QU 《Agricultural Biotechnology》 CAS 2023年第3期42-45,共4页
[Objectives] This study was conducted to explore the characteristics of natural grassland plant communities in the National Photovoltaic and Energy Storage Empirical Experiment Platform(Daqing Base), so as to provide ... [Objectives] This study was conducted to explore the characteristics of natural grassland plant communities in the National Photovoltaic and Energy Storage Empirical Experiment Platform(Daqing Base), so as to provide data reference for local grassland resources. [Methods] June to July, 2022, standard plot site investigation was carried out to investigate vegetation species, relative height, relative coverage, relative abundance, relative frequency and dominance in the National Photovoltaic and Energy Storage Empirical Experiment Platform in Datong District, Daqing City of Heilongjiang Province, and to analyze plant community structures in the photovoltaic DC field. [Results] The photovoltaic DC field contained 22 species of plants, of which Suaeda salsa was the common species. The dominant species in photovoltaic DC field were Leymus chinensis, Eleocharis intersita, Carex duriuscula and Carex rugurosa. [Conclusions] The dominant vegetation types were Poaceae and Cyperaceae in the natural grassland of the National Photovoltaic and Energy Storage Empirical Experiment Platform(Daqing Base). 展开更多
关键词 photovoltaic DC field Plant community distribution characteristics
下载PDF
Synergetic optimization operation method for distribution network based on SOP and PV
17
作者 Lei Chen Ning Zhang +4 位作者 Xingfang Yang Wei Pei Zhenxing Zhao Yinan Zhu Hao Xiao 《Global Energy Interconnection》 EI CSCD 2024年第2期130-141,共12页
The integration of distributed generation brings in new challenges for the operation of distribution networks,including out-of-limit voltage and power flow control.Soft open points(SOP)are new power electronic devices... The integration of distributed generation brings in new challenges for the operation of distribution networks,including out-of-limit voltage and power flow control.Soft open points(SOP)are new power electronic devices that can flexibly control active and reactive power flows.With the exception of active power output,photovoltaic(PV)devices can provide reactive power compensation through an inverter.Thus,a synergetic optimization operation method for SOP and PV in a distribution network is proposed.A synergetic optimization model was developed.The voltage deviation,network loss,and ratio of photovoltaic abandonment were selected as the objective functions.The PV model was improved by considering the three reactive power output modes of the PV inverter.Both the load fluctuation and loss of the SOP were considered.Three multi-objective optimization algorithms were used,and a compromise optimal solution was calculated.Case studies were conducted using an IEEE 33-node system.The simulation results indicated that the SOP and PVs complemented each other in terms of active power transmission and reactive power compensation.Synergetic optimization improves power control capability and flexibility,providing better power quality and PV consumption rate. 展开更多
关键词 Synergetic optimization Soft open point(SOP) photovoltaic(PV) distribution network
下载PDF
Extension of Distribution Transformer Life in the Presence of Smart Inverter-based Distributed Solar Photovoltaic Systems
18
作者 Kanhaiya Kumar Saran Satsangi Ganesh Balu Kumbhar 《CSEE Journal of Power and Energy Systems》 SCIE EI CSCD 2024年第1期88-95,共8页
A transformer is an essential but expensive power delivery equipment for a distribution utility.In many distribution utilities worldwide,a sizable percentage of transformers are near the end of their designed life.At ... A transformer is an essential but expensive power delivery equipment for a distribution utility.In many distribution utilities worldwide,a sizable percentage of transformers are near the end of their designed life.At the same time,distribution utilities are adopting smart inverter-based distributed solar photovoltaic(SPV)systems to maximize renewable generation.The central objective of this paper is to propose a methodology to quantify the effect of smart inverter-based distributed SPV systems on the aging of distribution transformers.The proposed method is first tested on a modified IEEE-123 node distribution feeder.After that,the procedure is applied to a practical distribution system,i.e.,the Indian Institute of Technology(IIT)Roorkee campus,India.The transformer aging models,alongside advanced control functionalities of grid-tied smart inverter-based SPV systems,are implemented in MATLAB.The open-source simulation tool(OpenDSS)is used to model distribution networks.To analyze effectiveness of various inverter functionalities,time-series simulations are performed using exponential load models,considering daily load curves from multiple seasons,load types,current harmonics,etc.Findings show replacing a traditional inverter with a smart inverter-based SPV system can enable local reactive power generation and may extend the life of a distribution transformer.Simulation results demonstrate,simply by incorporating smart inverter-based SPV systems,transformer aging is reduced by 15%to 22%in comparison to SPV systems operating with traditional inverters. 展开更多
关键词 distribution transformer loss of life smart inverter functions solar photovoltaic systems thermal models Volt-VAr control
原文传递
Distributed Photovoltaic Real-Time Output Estimation Based on Graph Convolutional Networks
19
作者 陈利跃 洪道鉴 +5 位作者 何星 卢东祁 张乾 谢妮娜 徐一洲 应煌浩 《Journal of Shanghai Jiaotong university(Science)》 EI 2024年第2期290-296,共7页
The rapid growth of distributed photovoltaic(PV)has remarkable influence for the safe and economic operation of power systems.In view of the wide geographical distribution and a large number of distributed PV power st... The rapid growth of distributed photovoltaic(PV)has remarkable influence for the safe and economic operation of power systems.In view of the wide geographical distribution and a large number of distributed PV power stations,the current situation is that it is dificult to access the current dispatch data network.According to the temporal and spatial characteristics of distributed PV,a graph convolution algorithm based on adaptive learning of adjacency matrix is proposed to estimate the real-time output of distributed PV in regional power grid.The actual case study shows that the adaptive graph convolution model gives different adjacency matrixes for different PV stations,which makes the corresponding output estimation algorithm have higher accuracy. 展开更多
关键词 distributed photovoltaic(PV) graph convolution network power estimation
原文传递
Distribution Line Longitudinal ProtectionMethod Based on Virtual Measurement Current Restraint
20
作者 WeiWang Yang Yu +3 位作者 Simin Luo Wenlin Liu Wei Tang Yuanbo Ye 《Energy Engineering》 EI 2024年第2期315-337,共23页
As an effective approach to achieve the“dual-carbon”goal,the grid-connected capacity of renewable energy increases constantly.Photovoltaics are the most widely used renewable energy sources and have been applied on ... As an effective approach to achieve the“dual-carbon”goal,the grid-connected capacity of renewable energy increases constantly.Photovoltaics are the most widely used renewable energy sources and have been applied on various occasions.However,the inherent randomness,intermittency,and weak support of grid-connected equipment not only cause changes in the original flow characteristics of the grid but also result in complex fault characteristics.Traditional overcurrent and differential protection methods cannot respond accurately due to the effects of unknown renewable energy sources.Therefore,a longitudinal protection method based on virtual measurement of current restraint is proposed in this paper.The positive sequence current data and the network parameters are used to calculate the virtual measurement current which compensates for the output current of photovoltaic(PV).The waveform difference between the virtual measured current and the terminal current for internal and external faults is used to construct the protection method.An improved edit distance algorithm is proposed to measure the similarity between virtual measurement current and terminal measurement current.Finally,the feasibility of the protection method is verified through PSCAD simulation. 展开更多
关键词 photovoltaic interconnection distribution network longitudinal protection method edit distance algorithm
下载PDF
上一页 1 2 106 下一页 到第
使用帮助 返回顶部