期刊文献+
共找到8,823篇文章
< 1 2 250 >
每页显示 20 50 100
A Distributed Photovoltaics Ordering Grid-Connected Method for Analyzing Voltage Impact in Radial Distribution Networks
1
作者 Cuiping Li Kunqi Gao +4 位作者 Can Chen Junhui Li Xiaoxiao Wang Yinchi Shao Xingxu Zhu 《Energy Engineering》 EI 2024年第10期2937-2959,共23页
In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and ba... In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact. 展开更多
关键词 Radial distribution network distributed photovoltaics photovoltaics grid-connected order degree electrical distance photovoltaics action area
下载PDF
Comprehensive Evaluation of Distributed PV Grid-Connected Based on Combined Weighting Weights and TOPSIS-RSR Method
2
作者 Yue Yang Jiarui Zheng +2 位作者 Long Cheng Yongnan Zhu Hao Wu 《Energy Engineering》 EI 2024年第3期703-728,共26页
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj... To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified. 展开更多
关键词 Distributed PV grid-connected comprehensive evaluation evaluation indicator system combined subjective and objective empowerment TOPSIS-RSR method
下载PDF
Enhancement of thermal rectification by asymmetry engineering of thermal conductivity and geometric structure for multi-segment thermal rectifier 被引量:1
3
作者 杜甫烨 张望 +1 位作者 王惠琼 郑金成 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第6期34-43,共10页
Thermal rectification is an exotic thermal transport phenomenon,an analog to electrical rectification,in which heat flux along one direction is larger than that in the other direction and is of significant interest in... Thermal rectification is an exotic thermal transport phenomenon,an analog to electrical rectification,in which heat flux along one direction is larger than that in the other direction and is of significant interest in electronic device applications.However,achieving high thermal rectification efficiency or rectification ratio is still a scientific challenge.In this work,we performed a systematic simulation of thermal rectification by considering both efforts of thermal conductivity asymmetry and geometrical asymmetry in a multi-segment thermal rectifier.It is found that the high asymmetry of thermal conductivity and the asymmetry of the geometric structure of multi-segment thermal rectifiers can significantly enhance the thermal rectification,and the combination of both thermal conductivity asymmetry and geometrical asymmetry can further improve thermal rectification efficiency.This work suggests a possible way for improving thermal rectification devices by asymmetry engineering. 展开更多
关键词 thermal conductivity SIMULATION thermal rectification multi-segment thermal rectifier
下载PDF
High-Efficiency Rectifier for Wireless Energy Harvesting Based on Double Branch Structure 被引量:1
4
作者 崔恒荣 焦劲华 +1 位作者 杨威 荆玉香 《Journal of Donghua University(English Edition)》 CAS 2023年第4期438-445,共8页
A rectifier circuit for wireless energy harvesting(WEH) with a wide input power range is proposed in this paper. We build up accurate models of the diodes to improve the accuracy of the design of the rectifier. Due to... A rectifier circuit for wireless energy harvesting(WEH) with a wide input power range is proposed in this paper. We build up accurate models of the diodes to improve the accuracy of the design of the rectifier. Due to the nonlinear characteristics of the diodes, a new band-stop structure is introduced to reduce the imaginary part impedance and suppress harmonics. A novel structure with double branches and an optimized λ/4 microstrip line is proposed to realize the power division ratio adjustment by the input power automatically. The proposed two branches can satisfy the two cases with input power of-20 dBm to 0 dBm and 0 dBm to 15 dBm, respectively. Here, dBm = 10 log(P mW), and P represents power. An impedance compression network(ICN) is correspondingly designed to maintain the input impedance stability over the wide input power range. A rectifier that works at 2.45 GHz is implemented. The measured results show that the highest efficiency can reach 51.5% at the output power of 0 dBm and higher than 40% at the input power of-5 dBm to 12 dBm. 展开更多
关键词 diode modeling rectifier circuit impedance compression network power division strategy
下载PDF
A Fractional Order Fast Repetitive Control Paradigm of Vienna Rectifier for Power Quality Improvement
5
作者 Sue Wang Xintao Luo +3 位作者 Saleem Riaz Haider Zaman Chaohong Zhou Pengfei Hao 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第2期1159-1176,共18页
Due to attractive features,including high efficiency,low device stress,and ability to boost voltage,a Vienna rectifier is commonly employed as a battery charger in an electric vehicle(EV).However,the 6k±1 harmoni... Due to attractive features,including high efficiency,low device stress,and ability to boost voltage,a Vienna rectifier is commonly employed as a battery charger in an electric vehicle(EV).However,the 6k±1 harmonics in the acside current of the Vienna rectifier deteriorate theTHDof the ac current,thus lowering the power factor.Therefore,the current closed-loop for suppressing 6k±1 harmonics is essential tomeet the desired total harmonic distortion(THD).Fast repetitive control(FRC)is generally adopted;however,the deviation of power grid frequency causes delay link in the six frequency fast repetitive control to become non-integer and the tracking performance to deteriorate.This paper presents the detailed parameter design and calculation of fractional order fast repetitive controller(FOFRC)for the non-integer delay link.The finite polynomial approximates the non-integer delay link through the Lagrange interpolation method.By comparing the frequency characteristics of traditional repetitive control,the effectiveness of the FOFRC strategy is verified.Finally,simulation and experiment validate the steadystate performance and harmonics suppression ability of FOFRC. 展开更多
关键词 Vienna rectifier fast repetitive control fractional order performance analysis
下载PDF
Dynamic phasor-based hybrid simulation for multi-inverter grid-connected system
6
作者 Peng Yang Qian Li +2 位作者 Junyu Zhao Juanjuan Lu Yunfei Xu 《Global Energy Interconnection》 EI CAS CSCD 2023年第2期197-204,共8页
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient... To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation. 展开更多
关键词 Multi-inverter grid-connected system Electromagnetic transient Dynamic phasor Hybrid simulation
下载PDF
Enhancement of holding voltage by a modified low-voltage trigger silicon-controlled rectifier structure for electrostatic discharge protection
7
作者 陈远康 周远良 +3 位作者 蒋杰 饶庭柯 廖武刚 刘俊杰 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第2期514-518,共5页
A novel structure of low-voltage trigger silicon-controlled rectifiers(LVTSCRs) with low trigger voltage and high holding voltage is proposed for electrostatic discharge(ESD) protection. The proposed ESD protection de... A novel structure of low-voltage trigger silicon-controlled rectifiers(LVTSCRs) with low trigger voltage and high holding voltage is proposed for electrostatic discharge(ESD) protection. The proposed ESD protection device possesses an ESD implant and a floating structure. This improvement enhances the current discharge capability of the gate-grounded NMOS and weakens the current gain of the silicon-controlled rectifier current path. According to the simulation results, the proposed device retains a low trigger voltage characteristic of LVTSCRs and simultaneously increases the holding voltage to 5.53 V, providing an effective way to meet the ESD protection requirement of the 5 V CMOS process. 展开更多
关键词 electrostatic discharge floating n-well low-voltage trigger silicon-controlled rectifier
下载PDF
A Hybrid Five-Level Single-Phase Rectifier with Low Common-Mode Voltage
8
作者 TIAN Ruihan WU Xuezhi +2 位作者 XU Wenzheng ZUO Zhiling CHEN Changqing 《ZTE Communications》 2023年第4期78-84,共7页
Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems... Rectifiers with high efficiency and high power density are crucial to the stable and efficient power supply of 5G communication base stations,which deserves in-depth investigation.In general,there are two key problems to be addressed:supporting both alternating current(AC)and direct current(DC)input,and minimizing the common-mode voltage as well as leakage current for safety reasons.In this paper,a hybrid five-level single-phase rectifier is proposed.A five-level topology is adopted in the upper arm,and a half-bridge diode topology is adopted in the lower arm.A dual closed-loop control strategy and a flying capacitor voltage regulation method are designed accordingly so that the compatibility of both AC and DC input is realized with low common voltage and small passive devices.Simulation and experimental results demonstrate the effectiveness and performance of the proposed rectifier. 展开更多
关键词 multilevel rectifier 5L-ANPC low common-mode voltage AC-DC hybrid input
下载PDF
Study on Various Rectifiers for Fan-Filter Units 被引量:3
9
作者 刘俊杰 涂光备 马九贤 《Transactions of Tianjin University》 EI CAS 2002年第2期119-124,共6页
The face velocities of the high efficiency particulate air filters and the ultra low penetration airfilters in fan filter units (FFUs) have large relative standard deviation and turbulivity. It seriously affects the ... The face velocities of the high efficiency particulate air filters and the ultra low penetration airfilters in fan filter units (FFUs) have large relative standard deviation and turbulivity. It seriously affects the unidirectivity of the flow in the unidirectional flow clean zone and cleanroom. The cross contamination in this kind of unidirectional flow area is hardly controlled. It is significant to find optional method for keeping the face velocity uniformity of FFU and reducing the face velocity turbulivity of FFU, furthermore, to keep the cleanliness level under FFUs. The normal and easy method is to add flow rectifiers under filters. FFUs with various flow rectifiers have been tested. The uniformity and turbulivity of facevelocity under the FFU are presented in this paper. The influence of the facevelocity uniformity and turbulivity on the contamination boundary of the unidirectional flow is studiedas well. 展开更多
关键词 unidirectional flow air velocity UNIFORMITY turbulivity flow rectifier fan filter unit (FFU)
下载PDF
Rectifier Configurations Based on Harmonic Injecting and Counteracting Principle
10
作者 何丹 戴先中 +1 位作者 肖仁良 徐以荣 《Journal of Southeast University(English Edition)》 EI CAS 1999年第1期81-88,共8页
On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper pr... On the basis of detailed analysis of a novel harmonic counteracting method which can be used to effectively compensate the supply line harmonic currents of a passive single phase diode bridge rectifier, this paper presents two simpler single phase diode bridge rectifier configurations and their alternatives which can achieve low supply line current THD(total harmonic distortion) too. Moreover, this paper also proposes a few passive hamonic counteracting networks for multi single phase rectifiers which are connected in parallel. 展开更多
关键词 single phase rectifier harmonic compensation current injection THD
下载PDF
Coordinate control strategy for stability operation of offshore wind farm integrated with Diode-rectifier HVDC 被引量:12
11
作者 Lijun Xie Liangzhong Yao +2 位作者 Fan Cheng Yan Li Shuai Liang 《Global Energy Interconnection》 2020年第3期205-216,共12页
Due to low investment cost and high reliability,a new scheme called DR-HVDC(Diode Rectifier based HVDC)transmission was recently proposed for grid integration of large offshore wind farms.However,in this scheme,the ap... Due to low investment cost and high reliability,a new scheme called DR-HVDC(Diode Rectifier based HVDC)transmission was recently proposed for grid integration of large offshore wind farms.However,in this scheme,the application of conventional control strategies for stability operation face several challenges due to the uncontrollability of the DR.In this paper,a coordinated control strategy of offshore wind farms using the DR-HVDC transmission technology to connect with the onshore grid,is investigated.A novel coordinated control strategy for DR-HVDC is proposed based on the analysis of the DC current control ability of the full-bridge-based modular multilevel converter(FB-MMC)at the onshore station and the input and output characteristics of the diode rectifier at the offshore.Considering the characteristics of operation stability and decoupling between reactive power and active power,a simplified design based on double-loop droop control for offshore AC voltage is proposed after power flow and voltage–current(I–V)characteristics of the offshore wind farm being analyzed.Furthermore,the impact of onshore AC fault to offshore wind farm is analyzed,and a fast fault detection and protection strategy without relying on communication is proposed.Case studies carried out by PSCAD/EMTDC verify the effectiveness of the proposed control strategy for the start up,power fluctuation,and onshore and offshore fault conditions. 展开更多
关键词 Diode rectifier HVDC PMSG FB-MMC Control strategy AC fault
下载PDF
Experimental and numerical analyses of high voltage 4H-SiC junction barrier Schottky rectifiers with linearly graded field limiting ring 被引量:2
12
作者 王向东 邓小川 +3 位作者 王永维 王勇 文译 张波 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第5期490-494,共5页
This paper describes the successful fabrication of 4H-SiC junction barrier Schottky (JBS) rectifiers with a linearly graded field limiting ring (LG-FLR). Linearly variable ring spacings for the FLR termination are... This paper describes the successful fabrication of 4H-SiC junction barrier Schottky (JBS) rectifiers with a linearly graded field limiting ring (LG-FLR). Linearly variable ring spacings for the FLR termination are applied to improve the blocking voltage by reducing the peak surface electric field at the edge termination region, which acts like a variable lateral doping profile resulting in a gradual field distribution. The experimental results demonstrate a breakdown voltage of 5 kV at the reverse leakage current density of 2 mA/cm2 (about 80% of the theoretical value). Detailed numerical simulations show that the proposed termination structure provides a uniform electric field profile compared to the conventional FLR termi- nation, which is responsible for 45% improvement in the reverse blocking voltage despite a 3.7% longer total termination length. 展开更多
关键词 4H-SIC junction barrier Schottky rectifier linearly graded field limiting ring breakdown voltage
下载PDF
Application of Single-to-Single Phase Matrix Conversion in Conventional Rectifier-Inverter 被引量:3
13
作者 YANG Xi jun, GONG You min School of Electromechanical Engineering and Automation, Shanghai University, Shanghai 200072, China 《Journal of Shanghai University(English Edition)》 CAS 2001年第3期211-216,共6页
The principle of single to single phase matrix electric power conversioin is further studied and the conversioin switch function is introduced into conventional rectifier inverter, thus a general character of the t... The principle of single to single phase matrix electric power conversioin is further studied and the conversioin switch function is introduced into conventional rectifier inverter, thus a general character of the two conversion techniques is discovered. It is characteristic of the switch functiion to follow mains voltage distortion and mains frequency drift. By utilizing the merit, unidirectional switch duty rations of the inverter follow the variation of DC link voltage automatically, thus the size of DC link electrolytic capacitor can be reduced considerably, bringing about improved mains side power factor. Corresponding topologies and theoretical and theoretical derivations are given, and so are the simulation results, based on which it is confirmed that the single to single phase matrix conversion technique is potentially useful in large scale production, and the introduction of switch function can yield good economic returns. 展开更多
关键词 sinele to sinele phase matrix electric power conversion introduction rectifier inverter DC link electrolytic capacitor mains side power factor
下载PDF
Trapezoid mesa trench metal-oxide semiconductor barrier Schottky rectifier:an improved Schottky rectifier with better reverse characteristics 被引量:1
14
作者 李惟一 茹国平 +1 位作者 蒋玉龙 阮刚 《Chinese Physics B》 SCIE EI CAS CSCD 2011年第8期376-383,共8页
An improved structure of Schottky rectifier, called a trapezoid mesa trench metal oxide semiconductor (MOS) barrier Schottky rectifier (TM-TMBS), is proposed and studied by two-dimensional numerical simulations. B... An improved structure of Schottky rectifier, called a trapezoid mesa trench metal oxide semiconductor (MOS) barrier Schottky rectifier (TM-TMBS), is proposed and studied by two-dimensional numerical simulations. Both forward and especially better reverse I-V characteristics, including lower leakage current and higher breakdown voltage, are demonstrated by comparing our proposed TM-TMBS with a regular trench MOS barrier Schottky rectifier (TMBS) as well as a conventional planar Schottky barrier diode rectifier. Optimized device parameters corresponding to the requirement for high breakdown voltage are given. With optimized parameters, TM-TMBS attains a breakdown voltage of 186 V, which is 6.3% larger than that of the optimized TMBS, and a leakage current of 4.3×10^-6 A/cm2, which is 26% smaller than that of the optimized TMBS. The relationship between optimized breakdown voltage and some device parameters is studied. Explanations and design rules are given according to this relationship. 展开更多
关键词 Schottky rectifier pinch-off effect breakdown power device
下载PDF
Numerical and experimental study of the mesa configuration in high-voltage 4H–SiC PiN rectifiers 被引量:1
15
作者 邓小川 陈茜茜 +2 位作者 李诚瞻 申华军 张金平 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第8期317-321,共5页
The effect of the mesa configuration on the reverse breakdown characteristic of a SiC PiN rectifier for high-voltage applications is analyzed in this study.Three geometrical parameters,i.e.,mesa height,mesa angle and ... The effect of the mesa configuration on the reverse breakdown characteristic of a SiC PiN rectifier for high-voltage applications is analyzed in this study.Three geometrical parameters,i.e.,mesa height,mesa angle and mesa bottom corner,are investigated by numerical simulation.The simulation results show that a deep mesa height,a small mesa angle and a smooth mesa bottom(without sub-trench) could contribute to a high breakdown voltage due to a smooth and uniform surface electric field distribution.Moreover,an optimized mesa structure without sub-trench(mesa height of 2.2 μm and mesa angle of 20°) is experimentally demonstrated.A maximum reverse blocking voltage of 4 kV and a forward voltage drop of 3.7 V at 100 A/cm^2 are obtained from the fabricated diode with a 30-μm thick N^- epi-layer,corresponding to 85% of the ideal parallel-plane value.The blocking characteristic as a function of the JTE dose is also discussed for the PiN rectifiers with and without interface charge. 展开更多
关键词 silicon carbide mesa configuration PiN rectifier breakdown voltage
下载PDF
A Nonlinear Control Strategy for Vienna Rectifier Under Unbalanced Input Voltage 被引量:1
16
作者 REN Xiaoyong CHEN Yu +2 位作者 TONG Dan ZHANG Zhiliang CHEN Qianhong 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI CSCD 2019年第5期703-714,共12页
The Vienna rectifier with unbalanced input voltage and load transient is analyzed.A nonlinear control strategy for Vienna rectifier under unbalanced input is proposed.From the view of positive and negative sequence co... The Vienna rectifier with unbalanced input voltage and load transient is analyzed.A nonlinear control strategy for Vienna rectifier under unbalanced input is proposed.From the view of positive and negative sequence components,the proposed nonlinear control strategy suppresses the twice frequency ripple and guarantees the dynamic response characteristic at the same time.Thanks to the proposed nonlinear control strategy,the DC bus capacitor can be reduced a lot since the voltage ripple and drop can be suppressed.A 10 kW Vienna rectifier is built to verify the proposed control strategy.After applying the proposed nonlinear control strategy,the voltage ripple is only7 V and decreases over 75%over the traditional PI control when the unbalanced degree is 20%.The voltage drop can be reduced about 80%than former control strategy which is helpful to reduce the DC bus capacitor and achieve higher power density.The volume of the capacitor can be reduced by 83.3%with the new control method. 展开更多
关键词 VIENNA rectifier radars unbalanced INPUT voltage NONLINEAR control strategy DC BUS CAPACITANCE
下载PDF
Differential Effects of d, l-Sotalol and d-Sotalol on Isoproterenol-Increased Delayed Rectifier Outward Potassium Current in Guinea Pig Single Ventricular Myocytes 被引量:1
17
作者 姚晓宙 陆再英 赵华月 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1998年第1期13-17,共5页
The aim of this study was to compare the effects of d, l-Sotalol and dSotalol on the delayed rectifier K+ outward current in the presence of isoproterenol at different concentrations. Time-dependent delayed rectifier... The aim of this study was to compare the effects of d, l-Sotalol and dSotalol on the delayed rectifier K+ outward current in the presence of isoproterenol at different concentrations. Time-dependent delayed rectifier K+ outward currents were measured in isolated guinea pig single myocytes using the whole-cell configuration of the patch-clamp technique. Currents were measured in response to 300 ms depolarizing pulses from a holding potential of -40 mV in three experimental protocols [control, isoproterenol (10^(9)mol/L - 10^(-6) mol/L ), and isoproterenol (10^(-9)mol/L - 10^(-6)mol/L ) plus either d, l-Sotalol (10^(-4) mol/L) or d-Sotalol (10^(-4) mol/L)]. IK tail currents were measured upon repolarization to -40 mV. It was found that Ik was significantly amplified in the presence. of isoproterenol (10^(-9) mol/L- 10^(-6) mol/L) plus d-Sotalol. At 10-8 mol/L isoproterenol, Ik was increased by 92. 7%±17. 1 % (P<0. 05) and 54. 3 %±13. 4 % after d-Sotalol addition (P<0. 05). In contrast, d, l-Sotalol completely conteracted the increase of iK by isoproterenol (<10^(-8) mol/L), and compared to control, Ic was decreased by 35. 6 % ±8. 1% at 10^(-8) mol/L isoproterenol plus d, l-Sotalol (P<0. 05). It is concluded that the β-adrenergic blocking property of d, l-Sotalol but not that of dSotalol maintains the delayed rectifier K+ outward current blockade in the presence of isoproterenol in guinea pig myocytes. This might contribute to a superior antiarrhythmic efficacy as compared to d-Sotalol. 展开更多
关键词 potassium channel delayed rectifier current antiarrhythmia agents cardiomyocytes CATECHOLAMINES
下载PDF
Study of a double epi-layers SiC junction barrier Schottky rectifiers embedded P layer in the drift region 被引量:1
18
作者 宋庆文 张玉明 +2 位作者 张义门 张倩 吕红亮 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期548-553,共6页
This paper proposes a double epi-layers 4H-SiC junction barrier Schottky rectifier (JBSR) with embedded P layer (EPL) in the drift region. The structure is characterized by the P-type layer formed in the n-type dr... This paper proposes a double epi-layers 4H-SiC junction barrier Schottky rectifier (JBSR) with embedded P layer (EPL) in the drift region. The structure is characterized by the P-type layer formed in the n-type drift layer by epitaxial overgrowth process. The electric field and potential distribution are changed due to the buried P-layer, resulting in a high breakdown voltage (BV) and low specific on-resistance (Ron,sp). The influences of device parameters, such as the depth of the embedded P+ regions, the space between them and the doping concentration of the drift region, etc., on BV and Ron,sp are investigated by simulations, which provides a particularly useful guideline for the optimal design of the device. The results indicate that BV is increased by 48.5% and Baliga's figure of merit (BFOM) is increased by 67.9% compared to a conventional 4H-SiC JBSR. 展开更多
关键词 junction barrier Schottky rectifier 4H-SiC breakdown voltage specific on-resistance
下载PDF
A novel dynamic equivalence method for grid-connected wind farm 被引量:2
19
作者 Jia-geng QIAO Zong-xiang LU Yong MIN 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第4期558-563,共6页
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a... Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method. 展开更多
关键词 grid-connected wind farm Dynamic equivalence Squirrel-Cage Induction Generator (SCIG) Genetic algorithm
下载PDF
Structure-dependent behaviors of diode-triggered silicon controlled rectifier under electrostatic discharge stress 被引量:1
20
作者 张立忠 王源 何燕冬 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第12期507-513,共7页
The comprehensive understanding of the structure-dependent electrostatic discharge behaviors in a conventional diode-triggered silicon controlled rectifier (DTSCR) is presented in this paper. Combined with the devic... The comprehensive understanding of the structure-dependent electrostatic discharge behaviors in a conventional diode-triggered silicon controlled rectifier (DTSCR) is presented in this paper. Combined with the device simulation, a mathematical model is built to get a more in-depth insight into this phenomenon. The theoretical studies are verified by the transmission-line-pulsing (TLP) test results of the modified DTSCR structure, which is realized in a 65-nm complementary metal-oxide-semiconductor (CMOS) process. The detailed analysis of the physical mechanism is used to provide predictions as the DTSCR-based protection scheme is required. In addition, a method is also presented to achieve the tradeoff between the leakage and trigger voltage in DTSCR. 展开更多
关键词 electrostatic discharge (ESD) diode-triggered silicon controlled rectifier (DTSCR) transmission-line-pulsing (TLP) mathematical modeling
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部