In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and ba...In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.展开更多
To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and obj...To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified.展开更多
Background:Mental health literacy(MHL)refers to one’s knowledge and understanding of mental health disorders and their treatments.This literacy may be influenced by cultural norms and values that shape individuals’e...Background:Mental health literacy(MHL)refers to one’s knowledge and understanding of mental health disorders and their treatments.This literacy may be influenced by cultural norms and values that shape individuals’experiences,beliefs,attitudes,and behaviors regarding mental health.This study focuses on adapting the Mental health literacy scale(MHLS)for use in the multicultural context of Israel.Objectives include validating its construct,assessing its accuracy in measuring MHL in this diverse setting and examining and comparing levels of MHL across different cultural groups.Methods:The data collection included 1057 participants,representing all the ethnic groups of the Israeli population aged 18 and over.The tools included the MHLS and a demographic questionnaire.Confirmatory factor analysis(CFA)was employed to assess the original structure of the MHLS.Results:The results revealed that after evaluating the original MHLS,five items were excluded,leading to the validation of a modified version—Israeli mental health scale(IMHLS)with four factors and 25 items.CFA and reliability analyses supported an established and robust four-factor model.Significant ethnic differences in MHLS scores were identified,with Muslim participants showing the highest familiarity with mental disorders,followed by Druze and Christian participants,while Jewish participants had the lowest familiarity.Conclusion:The study concluded that the IMHLS is a valid and reliable tool for assessing MHL in Israel’s diverse and multicultural population.The revised scale better reflects the cultural nuances of the Israeli context.The significant ethnic differences that the study revealed in IMHLS emphasize the importance of culturally sensitive mental health interventions tailored to different ethnic groups in Israel.展开更多
Geological strength index(GSI)has been widely used as an input parameter in predicting the strength and deformation properties of rock masses.This study derived a series of equations to satisfy the original GSI lines ...Geological strength index(GSI)has been widely used as an input parameter in predicting the strength and deformation properties of rock masses.This study derived a series of equations to satisfy the original GSI lines on the basic GSI chart.Two axes ranging from 0 to 100 were employed for surface conditions of the discontinuities and the structure of rock mass,which are independent of the input parameters.The derived equations can analyze GSI values ranging from 0 to 100 within±5%error.The engineering dimensions(EDs)such as the slope height,tunnel width,and foundation width were used together with representative elementary volume(REV)in jointed rock mass to define scale factor(sf)from 0.2 to 1 in evaluating the rock mass structure including joint pattern.The transformation of GSI into a scaledependent parameter based on engineering scale addresses a crucial requirement in various engineering applications.The improvements proposed in this study were applied to a real slope which was close to the time of failure.The results of stability assessments show that the new proposals have sufficient capability to define rock mass quality considering EDs.展开更多
The complexity of distribution network model mainly depends on the model scale of grid-connected distributed photovoltaic (PV) power generation. Therefore, the simulation performance of multi-scale PV model is the key...The complexity of distribution network model mainly depends on the model scale of grid-connected distributed photovoltaic (PV) power generation. Therefore, the simulation performance of multi-scale PV model is the key factor of the simulation accuracy in the specific operating scenarios of distribution network. In this paper, a multi-scale model of grid connected PV distributed generation system is proposed based on the mathematical model of grid-connected distributed PV power generation. It is analyzed that differences of simulation performance, such as adaptability of simulation step size, accuracy of output and the effect on voltage profile of distribution network, between PV models with different scales in IEEE 33 node example. Simulation results indicate that the multi-scale model is effective in improving the accuracy and efficiency of simulation under different operating conditions of distribution network.展开更多
Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, a...Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.展开更多
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima...This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.展开更多
In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. T...In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.展开更多
For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection int...For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.展开更多
A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditi...A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.展开更多
For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear l...For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy.展开更多
In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and batte...In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and battery bank for electrification to North-east region of Afghanistan to meet winter power shortages of the area. In the proposed model, there are three decision variables namely, the total area occupied by the set of PV panels, total swept area by the rotating turbines' blades, and the number of batteries. GA (genetic algorithm) is defined to find the optimal values of the decision variables. The objective of this research is to minimize the LCC (life cycle cost) of the hybrid renewable energy system, and ensuring at the same time systems reliability level which is measured in terms of LPSP (loss of power supply probability).展开更多
Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Th...Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment.展开更多
This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of...This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved.展开更多
To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient...To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.展开更多
Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focus...Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1.展开更多
As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, dampin...As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.展开更多
As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro...As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro-Grid Community(MGC).In order to reduce the operation and maintenance costs of a single micro grid and reduce the adverse effects caused by unnecessary energy interaction between the micro grid and the main grid while improving the overall economic benefits of the micro grid community,this paper proposes a bi-level energy management model with the optimization goal of maximizing the social welfare of the micro grid community and minimizing the total electricity cost of a single micro grid.The lower-level model optimizes the output of each equipment unit in the system and the exchange power between the system and the external grid with the goal of minimizing the operating cost of each microgrid.The upper-level model optimizes the goal ofmaximizing the socialwelfare of themicrogrid.Taking amicrogrid community with four microgrids as an example,the simulation analysis shows that the proposed optimization model is beneficial to reduce the operating cost of a single microgrid,improve the overall revenue of the microgrid community,and reduce the power interaction pressure on the main grid.展开更多
Background:In recent years,there has been increased research interest in both smartphone addiction and social media addiction as well as the development of psychometric instruments to assess these constructs.However,t...Background:In recent years,there has been increased research interest in both smartphone addiction and social media addiction as well as the development of psychometric instruments to assess these constructs.However,there is a lack of psychometric evaluation for instruments assessing smartphone addiction and social media addiction in Thailand.The present study evaluated the psychometric properties and gender measurement invariance of the Thai version of the Smartphone Application-Based Addiction Scale(SABAS)and Bergen Social Media Addiction Scale(BSMAS).Method:A total of 801 Thai university students participated in an online survey from January 2022 to July 2022 which included demographic information,SABAS,BSMAS,and the Internet Gaming Disorder Scale-Short Form(IGDS9-SF).Results:Confirmatory Factor Analyses(CFAs)found that both the SABAS and BSMAS had a one-factor structure.Findings demonstrated adequate psychometric properties of both instruments and also supported measurement invariance across genders.Moreover,scores on the SABAS and BSMAS were correlated with scores on the IGDS9-SF.Conclusion:The results indicated that the SABAS and BSMAS are useful psychometric instruments for assessing the risk of smartphone addiction and social media addiction among Thai young adults.展开更多
基金supported by North China Electric Power Research Institute’s Self-Funded Science and Technology Project“Research on Distributed Energy Storage Optimal Configuration and Operation Control Technology for Photovoltaic Promotion in the Entire County”(KJZ2022049).
文摘In recent years,distributed photovoltaics(DPV)has ushered in a good development situation due to the advantages of pollution-free power generation,full utilization of the ground or roof of the installation site,and balancing a large number of loads nearby.However,under the background of a large-scale DPV grid-connected to the county distribution network,an effective analysis method is needed to analyze its impact on the voltage of the distribution network in the early development stage of DPV.Therefore,a DPV orderly grid-connected method based on photovoltaics grid-connected order degree(PGOD)is proposed.This method aims to orderly analyze the change of voltage in the distribution network when large-scale DPV will be connected.Firstly,based on the voltagemagnitude sensitivity(VMS)index of the photovoltaics permitted grid-connected node and the acceptance of grid-connected node(AoGCN)index of other nodes in the network,thePGODindex is constructed to determine the photovoltaics permitted grid-connected node of the current photovoltaics grid-connected state network.Secondly,a photovoltaics orderly grid-connected model with a continuous updating state is constructed to obtain an orderly DPV grid-connected order.The simulation results illustrate that the photovoltaics grid-connected order determined by this method based on PGOD can effectively analyze the voltage impact of large-scale photovoltaics grid-connected,and explore the internal factors and characteristics of the impact.
基金support of the project“State Grid Corporation Headquarters Science and Technology Program(5108-202299258A-1-0-ZB)”.
文摘To effectively quantify the impact of distributed photovoltaic(PV)access on the distribution network,this paper proposes a comprehensive evaluation method of distributed PV grid connection combining subjective and objective combination of assignment and technique for order preference by similarity to an ideal solution(TOPSIS)—rank sum ratio(RSR)(TOPSIS-RSR)method.Based on the traditional distribution network evaluation system,a comprehensive evaluation system has been constructed.It fully considers the new development requirements of distributed PV access on the environmental friendliness and absorptive capacity of the distribution grid and comprehensively reflects the impact of distributed PV grid connection.The analytic hierarchy process(AHP)was used to determine the subjective weights of the primary indicators,and the Spearman consistency test was combined to determine the weights of the secondary indicators based on three objective assignment methods.The subjective and objective combination weights of each assessment indicator were calculated through the principle of minimum entropy.Calculate the distance between the indicators to be evaluated and the positive and negative ideal solutions,the relative closeness ranking,and qualitative binning by TOPSIS-RSR method to obtain the comprehensive evaluation results of different scenarios.By setting up different PV grid-connected scenarios and utilizing the IEEE33 node simulation algorithm,the correctness and effectiveness of the proposed subject-object combination assignment and integrated assessment method are verified.
文摘Background:Mental health literacy(MHL)refers to one’s knowledge and understanding of mental health disorders and their treatments.This literacy may be influenced by cultural norms and values that shape individuals’experiences,beliefs,attitudes,and behaviors regarding mental health.This study focuses on adapting the Mental health literacy scale(MHLS)for use in the multicultural context of Israel.Objectives include validating its construct,assessing its accuracy in measuring MHL in this diverse setting and examining and comparing levels of MHL across different cultural groups.Methods:The data collection included 1057 participants,representing all the ethnic groups of the Israeli population aged 18 and over.The tools included the MHLS and a demographic questionnaire.Confirmatory factor analysis(CFA)was employed to assess the original structure of the MHLS.Results:The results revealed that after evaluating the original MHLS,five items were excluded,leading to the validation of a modified version—Israeli mental health scale(IMHLS)with four factors and 25 items.CFA and reliability analyses supported an established and robust four-factor model.Significant ethnic differences in MHLS scores were identified,with Muslim participants showing the highest familiarity with mental disorders,followed by Druze and Christian participants,while Jewish participants had the lowest familiarity.Conclusion:The study concluded that the IMHLS is a valid and reliable tool for assessing MHL in Israel’s diverse and multicultural population.The revised scale better reflects the cultural nuances of the Israeli context.The significant ethnic differences that the study revealed in IMHLS emphasize the importance of culturally sensitive mental health interventions tailored to different ethnic groups in Israel.
文摘Geological strength index(GSI)has been widely used as an input parameter in predicting the strength and deformation properties of rock masses.This study derived a series of equations to satisfy the original GSI lines on the basic GSI chart.Two axes ranging from 0 to 100 were employed for surface conditions of the discontinuities and the structure of rock mass,which are independent of the input parameters.The derived equations can analyze GSI values ranging from 0 to 100 within±5%error.The engineering dimensions(EDs)such as the slope height,tunnel width,and foundation width were used together with representative elementary volume(REV)in jointed rock mass to define scale factor(sf)from 0.2 to 1 in evaluating the rock mass structure including joint pattern.The transformation of GSI into a scaledependent parameter based on engineering scale addresses a crucial requirement in various engineering applications.The improvements proposed in this study were applied to a real slope which was close to the time of failure.The results of stability assessments show that the new proposals have sufficient capability to define rock mass quality considering EDs.
文摘The complexity of distribution network model mainly depends on the model scale of grid-connected distributed photovoltaic (PV) power generation. Therefore, the simulation performance of multi-scale PV model is the key factor of the simulation accuracy in the specific operating scenarios of distribution network. In this paper, a multi-scale model of grid connected PV distributed generation system is proposed based on the mathematical model of grid-connected distributed PV power generation. It is analyzed that differences of simulation performance, such as adaptability of simulation step size, accuracy of output and the effect on voltage profile of distribution network, between PV models with different scales in IEEE 33 node example. Simulation results indicate that the multi-scale model is effective in improving the accuracy and efficiency of simulation under different operating conditions of distribution network.
文摘Dynamic equivalence of the wind farm is a fundamental problem in the simulation of a power system connected with wind farms because it is unpractical to model every generator in a wind farm in detail. In this paper, an Equivalence Method based on the Output Characteristics (EMOC) is proposed, with which the wind farm composed of Squirrel-Cage Induction Generators (SCIGs) can be equivalent to one generator. By considering the diversity of wind generators and special operating characteristics of a wind farm, the equivalent generator based on EMOC responds accurately in various faults. No matter whether the wind farm is integrated in grid or just programmed, EMOC can be used to acquire an accurate equivalent generator. Simulation of the dynamic equivalence of an SCIG wind farm validated the method.
文摘This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.
基金supported by Delta Power Electronic Science and Education Development in 2007 (Grant No.DRES2007002)
文摘In wind power generation system the grid-connected inverter is an important section for energy conversion and transmission, of which the performance has a direct influence on the entire wind power generation system. The mathematical model of the grid-connected inverter is deduced firstly. Then, the space vector pulse width modulation (SVPWM) is analyzed. The power factor can be controlled close to unity, leading or lagging, which is realized based on H-type current controller and grid voltage vector-oriented control. The control strategy is verified by the simulation and experimental results with a good sinusoidal current, a small harmonic component and a fast dynamic response.
文摘For a standalone PV (photovoltaic) power generation system, the author previously proposed a new MPPT (maximum power point tracking) control method in which the I-V characteristics are scanned with a detection interval control that operates at specified intervals and monitors the maximum power point. The author has obtained satisfactory results using this new MPPT control method. This paper investigates the application of the new MPPT control method for a PCS (power conditioning system) in a grid-connected type PV power generation system. The experimental results clearly demonstrate that the developed PCS offers outstanding effectiveness in tracking the maximum power point in partially shaded environments.
基金supported by the Shanghai Leading Academic Discipline Project (Grant No.T0103)
文摘A novel topology of the current-source grid-connected inverter is proposed based on the immittance converter theory. A control strategy of sine-sine pulse width modulation (PWM) is studied. Compared with the traditional current-source inverter, the power frequency inductors and power frequency transformer are replaced with high frequency inductors and a high frequency transformer. Thus, the proposed inverter has advantages of small volume, low cost, low total harmonic distortion (THD), low power losses, high power factor (PF) and simple control. Furthermore, grid voltage cannot influence output current of the grid-connected inverter and the current-source inverter with a high PF that approaches one has been realized. Finally, validity of the theory analysis and feasibility of the control scheme are shown by simulation and experimental results.
基金Project(51107111)supported by the National Natural Science Foundation of China
文摘For multiple grid-connected inverters with active filter function,it makes sense to regulate every unit to output maximum active power from photovoltaic arrays,as well as eliminate the harmonic due to the non-linear loads connected to the electric networks.Naturally,a centralized control coordination strategy was proposed for the purpose of high facility utilization,good harmonic compensation ability and unwanted overcompensation condition.Based on a vector decoupling control scheme and generalized instantaneous reactive power theory,the solution was to allocate the harmonic eliminating task for every inverter according to the instantaneous power margin of each.The grid current always keeps sinusoidal in spite of non-linear load change and output active power change for any inverter.The simulation results validate the efficacy of the proposed coordination strategy.
文摘In this paper, an optimized model is proposed to find the best values for decision variables to optimize the grid connected hybrid renewable energy system which consists of photovoltaic panels, wind turbines and battery bank for electrification to North-east region of Afghanistan to meet winter power shortages of the area. In the proposed model, there are three decision variables namely, the total area occupied by the set of PV panels, total swept area by the rotating turbines' blades, and the number of batteries. GA (genetic algorithm) is defined to find the optimal values of the decision variables. The objective of this research is to minimize the LCC (life cycle cost) of the hybrid renewable energy system, and ensuring at the same time systems reliability level which is measured in terms of LPSP (loss of power supply probability).
基金Project(51307009)supported by the National Natural Science Foundation of ChinaProject(12JJ4045)supported by Hunan Provincial Natural Science Foundation,China+2 种基金Project(2011KFJJ003)supported by the Key Laboratory for Power Technology of Renewable Energy Sources of Hunan Province,ChinaProject(2011kfj14)supported by the Fund of Key Laboratory of Hunan Province about Power System Operation and Control,ChinaProject(454.13S-20)supported by the Enterprises’Postdoctoral Funds of Pudong Area of Shanghai,China
文摘Modeling method for the current control loop of a grid-connected PWM inverter with the LCL output filter was discussed.Firstly,the current control loop with the LCL inverter-side current as feedback was established.Then,parameters of PI controller were calculated on the basis of an equivalent controlled object.Finally,Norton equivalent circuit for the current control loop of grid-connected system was derived by integrating one control equation,which connected the PWM inverter output voltage and the LCL inverter-side current,with two circuit equations,separately using the LCL inverter-side current and the injected current as loop currents.With the induced Norton equivalent circuit,system-level resonant and unstable issues on real grid-connected system applied in weak distributed power systems can be easily analyzed.The validity of substituting Norton equivalent circuit for grid-connected system is verified by simulation and experiment.
基金supported by the National Natural Science Foundation of China(No.61903291)。
文摘This paper proposes a cascade repetitive control strategy based on odd internal mode,and combines it with proportional-integral(PI)control to establish a compound repetitive control system for improving the quality of grid connected current of LCL grid connected inverter.More specifically,the proposed method could effectively improve the control effect of grid-connected current of LCL inverter,restrain current harmonics and reduce the distortion rate of grid-connected current.Simulation experiment is conducted to verify the proposed repetitive control strategy,and the verification results show that,compared with traditional PI control,the proposed improved compound repetitive control strategy has a higher response speed,and the steady-state and dynamic performance have also been significantly improved.
基金supported by the State Grid Science and Technology Project (grant no. KJ2021-069)。
文摘To realize the efficient transient simulation of a grid-connected power generation system based on multiple inverters, this paper proposes a hybrid simulation method integrating the models of electromagnetic transient and dynamic phasors. Based on a demonstration of the concepts and properties of dynamic phasors, the models of single-phase and three-phase inverters described by dynamic phasors are established first. Considering the numerical compatibility problem between dynamic phasors and instantaneous values, an interface scheme between dynamic phasors and instantaneous values is designed, and the efficiency and precision differences of various transformation methods are compared in detail.Finally, by utilizing MATLAB/Simulink, a hybrid simulation platform of a multi-inverter grid-connected system is built, and the efficiency and accuracy of the hybrid simulation are validated via comparison with the full electromagnetic transient simulation.
基金This research is supported by the MATLAB/Simulink,Rajamangala University of Technology Rattanakosin.
文摘Nowadays,the single state inverter for the grid-connected photovoltaic(PV)systems is becoming more and more popular as they can reduce circuit complexity resulting in less power losses of the inverter.This paper focuses on the use of model predictive control(MPC)to control a 3-phase and 2-level single-state grid-connected inverter in order to regulate the PV maximum power point(MPP).The algorithm of MPC scheme was done to measure the simultaneous current signal including predicting the next sampling current flow.The reference current(Id∗)was used to control the distribution of electrical power from the solar cell to the grid.To be able to control the maximum power point tracking(MPPT)when the sunlight suddenly changes,so that a developing MPPT based on estimation current perturbation and observation(ECP&O-MPPT)technique was used to control the reference current.This concept was experimented by using MATLAB/Simulink software package.The proposed technique was tested and compared with the old technique.The simulation results showed that the developed MPPT technique can track the MPP faster when the light changes rapidly under 1,000W/m2,25℃ standard climatic conditions.The MPPT time was 0.015 s.The total harmonic distortion(THD)was 2.17%and the power factor was 1.
文摘As to the concrete topology of three-phase LCL type grid-connected inverter with damping resistance, mathematical model was deduced in detail, using method of equivalent transformation to the structure diagram, damping resistance was virtualized, mathematical model under the DQ frame that can realize decoupling control was established, a dual-loop control strategy for grid-connected inverter with LCL filter was proposed, the system stability was analyzed and the design method of controller was given. The proposed method overcame the flaws of loss increase, efficiency reduce and cost increase which were caused by damping resistance in LCL type grid-connected inverter, the system efficiency and power supply quality of the output were improved. Feasibility and effectiveness of the new method were validated by simulation and experimental results.
基金This paper is supported by Science and Technology Project of State Grid(The construction of provincial energy big data ecosystem and the application practice research of data value-added service for the park,5400-202012224A-0-0-00).
文摘As the proportion of renewable energy power generation continues to increase,the number of grid-connected microgrids is gradually increasing,and geographically adjacent microgrids can be interconnected to form a Micro-Grid Community(MGC).In order to reduce the operation and maintenance costs of a single micro grid and reduce the adverse effects caused by unnecessary energy interaction between the micro grid and the main grid while improving the overall economic benefits of the micro grid community,this paper proposes a bi-level energy management model with the optimization goal of maximizing the social welfare of the micro grid community and minimizing the total electricity cost of a single micro grid.The lower-level model optimizes the output of each equipment unit in the system and the exchange power between the system and the external grid with the goal of minimizing the operating cost of each microgrid.The upper-level model optimizes the goal ofmaximizing the socialwelfare of themicrogrid.Taking amicrogrid community with four microgrids as an example,the simulation analysis shows that the proposed optimization model is beneficial to reduce the operating cost of a single microgrid,improve the overall revenue of the microgrid community,and reduce the power interaction pressure on the main grid.
基金This research was funded by the Ministry of Science and Technology,Taiwan(MOST 110-2410-H-006-115)the Higher Education Sprout Project,Ministry of Education to the Headquarters of University Advancement at National Cheng Kung University(NCKU)the 2021 Southeast and South Asia and Taiwan Universities Joint Research Scheme(NCKU 31),and the E-Da Hospital(EDAHC111004).
文摘Background:In recent years,there has been increased research interest in both smartphone addiction and social media addiction as well as the development of psychometric instruments to assess these constructs.However,there is a lack of psychometric evaluation for instruments assessing smartphone addiction and social media addiction in Thailand.The present study evaluated the psychometric properties and gender measurement invariance of the Thai version of the Smartphone Application-Based Addiction Scale(SABAS)and Bergen Social Media Addiction Scale(BSMAS).Method:A total of 801 Thai university students participated in an online survey from January 2022 to July 2022 which included demographic information,SABAS,BSMAS,and the Internet Gaming Disorder Scale-Short Form(IGDS9-SF).Results:Confirmatory Factor Analyses(CFAs)found that both the SABAS and BSMAS had a one-factor structure.Findings demonstrated adequate psychometric properties of both instruments and also supported measurement invariance across genders.Moreover,scores on the SABAS and BSMAS were correlated with scores on the IGDS9-SF.Conclusion:The results indicated that the SABAS and BSMAS are useful psychometric instruments for assessing the risk of smartphone addiction and social media addiction among Thai young adults.