In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of ro...In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.展开更多
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv...This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions.展开更多
This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction g...This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller.展开更多
Disconnections due to voltage drops in the grid cannot be permitted if wind turbines(WTs)contribute significantly to electricity pro-duction,as this increases the risk of production loss and destabilizes the grid.To m...Disconnections due to voltage drops in the grid cannot be permitted if wind turbines(WTs)contribute significantly to electricity pro-duction,as this increases the risk of production loss and destabilizes the grid.To mitigate the negative effects of these occurrences,WTs must be able to ride through the low-voltage conditions and inject reactive current to provide dynamic voltage support.This paper investigates the low-voltage ride-through(LVRT)capability enhancement of a Type-3 WT utilizing a dynamic voltage restorer(DVR).During the grid voltage drop,the DVR quickly injects a compensating voltage to keep the stator voltage constant.This paper proposes an active disturbance rejection control(ADRC)scheme to control the rotor-side,grid-side and DVR-side converters in a wind–DVR integrated network.The performance of the Type-3 WT with DVR topology is evaluated under various test conditions using MATLAB®/Simulink®.These simulation results are also compared with the experimental results for the LVRT capability performed on a WT emulator equipped with a crowbar and direct current(DC)chopper.The simulation results demonstrate a favourable transient and steady-state response of the Type-3 wind turbine quantities defined by the LVRT codes,as well as improved reactive power support under balanced fault conditions.Under the most severe voltage drop of 95%,the stator currents,rotor currents and DC bus voltage are 1.25 pu,1.40 pu and 1.09 UDC,respectively,conforming to the values of the LVRT codes.DVR controlled by the ADRC technique significantly increases the LVRT capabilities of a Type-3 doubly-fed induction generator-based WT under symmetrical voltage dip events.Although setting up ADRC controllers might be challenging,the proposed method has been shown to be extremely effective in reducing all kinds of internal and external disturbances.展开更多
As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power syst...As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model.展开更多
Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far fr...Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far from the load centers. Generally series compensated AC transmission and high voltage DC transmission are made use of to improve the transmission capacity as two main effective ways which can solve the problem of large scale wind power transmission. The paper describes the three kinds of impact varieties and impact mechanisms in the sub-synchronous oscillation phenomena of wind power system based on doubly fed induction generator (DFIG) wind generators. At last, we point out the important problem that should be stressed in the wind power system.展开更多
For doubly-fed induction generator(DFIG)-based wind turbines(WTs),various advanced control schemes have been proposed to achieve the low voltage ride through(LVRT)capability,whose parameters design is significantly re...For doubly-fed induction generator(DFIG)-based wind turbines(WTs),various advanced control schemes have been proposed to achieve the low voltage ride through(LVRT)capability,whose parameters design is significantly reliant on the rotor electromotive force(EMF)of DFIG-based WTs.However,the influence of the rotor current on EMF is usually ignored in existing studies,which cannot fully reflect the transient characteristics of EMF.To tackle with this issue,this study presents a comprehensive and quantitative analysis of EMF during grid faults considering various control modes.First,the DFIG model under grid faults is established.Subsequently,the transient characteristics of EMF are analyzed under different control modes(that is,rotor open-circuit and connected to converter).Furthermore,the EMF transient eigenvolumes(that is,accessorial resistance item,transient decay time constant,and frequency offset)are quantitatively analyzed with the typical parameters of MW-level DFIG-based WT.The analysis results contribute to the design of the LVRT control scheme.Finally,the analysis is validated by the hardware-in-the-loop experiments.展开更多
In this paper,an overview of several strategies for fault ride-through(FRT)capability improvement of a doubly-fed induction generator(DFIG)-based wind turbine is presented.Uncertainties and parameter variations have a...In this paper,an overview of several strategies for fault ride-through(FRT)capability improvement of a doubly-fed induction generator(DFIG)-based wind turbine is presented.Uncertainties and parameter variations have adverse effects on the performance of these strategies.It is desirable to use a control method that is robust to such distur-bances.Auto disturbance rejection control(ADRC)is one of the most common methods for eliminating the effects of disturbances.To improve the performance of the conventional ADRC,a modified ADRC is introduced that is more robust to disturbances and offers better responses.The non-derivability of the fal function used in the conventional ADRC degrades its efficiency,so the modified ADRC uses alternative functions that are derivable at all points,i.e.,the odd trigonometric and hyperbolic functions(arcsinh,arctan,and tanh).To improve the effciency of the proposed ADRC,fuzzy logic and fractional-order functions are used simultaneously.In fuzzy fractional-order ADRC(FFOADRC),all disturbances are evaluated using a nonlinear fractional-order extended state observer(NFESO).The performance of the suggested structure is investigated in MATLAB/Simulink.The simulation results show that during disturbances such as network voltage sag/swell,using the modified ADRCs leads to smaller fluctuations in stator flux amplitude and DC-link voltage,lower variations in DFIG velocity,and lower total harmonic distortion(THD)of the stator current.This demonstrates the superiority over conventional ADRC and a proportional-integral(PI)controller.Also,by chang-ing the crowbar resistance and using the modified ADRCs,the peak values of the waveforms(torque and currents)can be controlled at the moment of fault occurrence with no significant distortion.展开更多
This paper presents a new control strategy for the rotor side converter of Doubly-Fed Induction Generator based Wind Turbine systems,under severe voltage dips.The main goal is to fulfill the Low Voltage Ride Through p...This paper presents a new control strategy for the rotor side converter of Doubly-Fed Induction Generator based Wind Turbine systems,under severe voltage dips.The main goal is to fulfill the Low Voltage Ride Through performance,required by modern grid codes.In this respect,the key point is to limit oscillations(particularly on rotor currents)triggered by line faults,so that the system keeps operating with graceful behavior.To this aim,a suitable feedforward-feedback control solution is proposed for the DFIG rotor side.The feedforward part exploits oscillation-free reference trajectories,analytically derived for the system internal dynamics.State feedback,designed accounting for control voltage limits,endows the system with robustness and further tame oscillations during faults.Moreover,improved torque and stator reactive power tracking during faults is achieved,proposing an exact mapping between such quantities and rotor-side currents,which are conventionally used as controlled outputs.Numerical simulations are provided to validate the capability of the proposed approach to effectively cope with harsh faults.展开更多
The current paper talks about the variable speed wind turbine generation system (WTGS). So, the WTGS is equipped with a doubly-fed induction generator (DFIG) and two bidirectional converters in the rotor open circ...The current paper talks about the variable speed wind turbine generation system (WTGS). So, the WTGS is equipped with a doubly-fed induction generator (DFIG) and two bidirectional converters in the rotor open circuit. A vector control (VC) of the rotor side converter (RSC) offers independent regulation of the stator active and reactive power and the optimal rotational speed tracking in the power maximization operating mode. A VC scheme for the grid-side converter (GSC) allows an independent regulation of the active and reactive power to exchange with the grid and sinusoidal supply currents and keeps the DC-link voltage constant. A fuzzy inference system (FIS) is adopted as an alternative of the conven- tional proportional and integral (PI) controller to reject some uncertainties or disturbance. The performances have been verified using the Matlab/Simulink soft-ware.展开更多
The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The cont...The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment.展开更多
Wind power(WP)is considered as one of the main renewable energy sources(RESs)for future low-carbon and high-cost-efficient power system.However,its low inertia characteristic may threaten the system frequ-ency stabili...Wind power(WP)is considered as one of the main renewable energy sources(RESs)for future low-carbon and high-cost-efficient power system.However,its low inertia characteristic may threaten the system frequ-ency stability of the power system with a high penetration of WP generation.Thus,the capability of WP participating in the system frequency regulation has become a research hotspot.In this paper,the impact of WP on power system frequency stability is initially presented.In addition,various existing control strategies of WP participating in frequency regulation are reviewed from the wind turbine(WT)level to the wind farm(WF)level,and their perfor-mances are compared in terms of operating principles and practical applications.The pros and cons of each control strategy are also discussed.Moreover,the WP combing with energy storage system(ESS)for system frequency regulation is explored.Furthermore,the prospects,future challenges,and solutions of WP participating in power system frequency regulation are summarized.展开更多
A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper ...A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper is on the experimental validation of a generic electromagnetic transient-type(EMT-type)model of aggregated WTGs or wind parks suitable for transient studies.The phasor domain equivalent of the generic model,suitable for protection tools based on steady-state solvers,is also considered.The model has been validated using two sets of actual relay records for the fault response of two wind parks consisting of Type-III WTGs and connected to115 kV and 230 kV transmission systems.The objective is to show that the generic model can reproduce the actual fault response in simulations,and protection engineers can obtain accurate models of wind parks using fault records.A distinctive characteristic of a WTG is its substantially different negative sequence fault current contribution compared to a synchronous generator.The paper shows that the generic model provides enough options to reproduce the negative sequence behavior and hence is suitable for fault studies involving negative sequence-based protection.展开更多
With the increasing share of wind power,it is expected that wind turbines would provide frequency regulation ancillary service.However,the complex wake effect intensifies the difficulty in controlling wind turbines an...With the increasing share of wind power,it is expected that wind turbines would provide frequency regulation ancillary service.However,the complex wake effect intensifies the difficulty in controlling wind turbines and evaluating the frequency regulation potential from the wind farm.We propose a novel frequency control scheme for doubly-fed induction generator(DFIG)-based wind turbines,in which the wake effect is considered.The proposed control scheme is developed by incorporating the virtual inertia control and primary frequency control in a holistic way.To facilitate frequency regulation in timevarying operation status,the control gains are adaptively adjusted according to wind turbine operation status in the proposed controller.Besides,different kinds of power reserve control approaches are explicitly investigated.Finally,extensive case studies are conducted and simulation results verify that the frequency behavior is significantly improved via the proposed control scheme.展开更多
This paper presents an enhanced control strategy for Wind Energy Conversion System(WECS)using Doubly-Fed Induction Generator(DFIG).A robust Super-Twisting(STW)sliding mode control for variable speed wind turbine is de...This paper presents an enhanced control strategy for Wind Energy Conversion System(WECS)using Doubly-Fed Induction Generator(DFIG).A robust Super-Twisting(STW)sliding mode control for variable speed wind turbine is developed to produce the optimal aerodynamic torque and improve the dynamic performance of the WECS.The electromagnetic torque of the DFIG is directly tracked using the proposed control to achieve maximum power extraction.The performance and the effectiveness of the STW control strategy are compared to conventional Sliding Mode(SM)and Proportional-Integral(PI)controllers.The proposed STW algorithm shows interesting features in terms of chattering reduction,finite convergence time and robustness against parameters variations and system disturbances.展开更多
The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid c...The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.This paper shows otherwise and how the control strategy of converters plays a key role in the formation of the active and reactive current components.After investigating the existing control strategies from the perspective of grid code compliance and showing how they fail in addressing emerging requirements on the negative-sequence reactive current,we propose a new coordinated control strategy that complies with reactive current requirements in grid codes in the positive-and negative-sequence systems.The proposed method fully takes advantage of the current and voltage capacities of both the rotor-side converter(RSC)and grid-side converter(GSC),which enables the grid code compliance of the DFIG under unbalanced three-phase voltages due to asymmetrical faults.The mathematical investigations and proposed strategy are validated with detailed simulation models using the Electric Power Research Institute(EPRI)benchmark system.The derived mathematical expressions provide analytical clarifications on the response of the DFIG in the negative-sequence system from the grid perspective.展开更多
基金The authors highly acknowledge the technology financial assistance provided by Jiangsu Frontier Electric Technology Co.,Ltd.(KJ202003).
文摘In order to solve the problems of rotor overvoltage,overcurrent and DC side voltage rise caused by grid voltage drops,a coordinated control strategy based on symmetrical and asymmetrical low voltage ride through of rotor side converter of the doubly-fed generator is proposed.When the power grid voltage drops symmetrically,the generator approximate equation under steady-state conditions is no longer applicable.Considering the dynamic process of stator current excitation,according to the change of stator flux and the depth of voltage drop,the system can dynamically provide reactive power support for parallel nodes and suppress the rise of DC side voltage and rotor over-current.When the grid voltage drops asymmetrically,the positive and negative sequence components are separated in the rotating coordinate system.The doubly fed generator model is established to suppress the rotor positive sequence current and negative sequence current respectively.At the same time,the output voltage limit of the converter is discussed,and the reference value is adjusted within the allowable output voltage range.In order to adapt to the occurrence of different types of power grid faults and complex operating conditions,a fast switching module of fault type detection and rotor control mode is designed to detect the type of power grid faults and voltage drop depth in real time and switch the rotor side control mode dynamically.Finally,the simulation model of the doubly fed wind turbine is constructed in Matlab/Simulink.The simulation results verify that the proposed control strategy can improve the low-voltage ride through performance of the system when dealing with the symmetrical and asymmetric voltage drop of the power grid and identify the power grid fault type and provide the correct control strategy.
基金Project (No. 50577056) supported by the National Natural Science Foundation of China
文摘This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions.
文摘This paper aims to address the issue of control of a variable-speed wind turbine based on doubly-fed induction generators. In this work,an effort is made to extract the maximum efficiency from a doubly-fed induction generator-based variable-speed wind turbine by controlling the rotor current. In the first step, a maximum power point tracking technique is used to extract the maximum power from theturbine. Then a stator-flux-oriented vector control strategy is employed to control the rotor-side current. Subsequently, a grid voltagevector-oriented control strategy is used to control the grid-side system of the grid-connected generator. Considering the nonlinearityand parameter uncertainty of the system, an active disturbance rejection controller with a sliding-mode-based extended-state observeris developed for the above-mentioned control strategies. Furthermore, the stability of the controller is tested and the performance of thecontroller is compared with the classical proportional-integral controller based on disturbance rejection, robustness and tracking capability in a highly non-linear wind speed variation scenario. Modelling, control and comparison are conducted in the MATLAB®/Simulink®environment. Finally, a real-time hardware set-up is presented using the dSPACE ds-1104 R&D processing board to validate the controlscheme. From the result of the experiments, it is seen that the proposed controller takes 10-15 control cycles to settle to its steady-statevalues, depending on the control loop, whereas the conventional proportional-integral controller takes 60-75 control cycles. As a result,the settling time for the proposed control scheme is shorter than that of the proportional-integral controller.
文摘Disconnections due to voltage drops in the grid cannot be permitted if wind turbines(WTs)contribute significantly to electricity pro-duction,as this increases the risk of production loss and destabilizes the grid.To mitigate the negative effects of these occurrences,WTs must be able to ride through the low-voltage conditions and inject reactive current to provide dynamic voltage support.This paper investigates the low-voltage ride-through(LVRT)capability enhancement of a Type-3 WT utilizing a dynamic voltage restorer(DVR).During the grid voltage drop,the DVR quickly injects a compensating voltage to keep the stator voltage constant.This paper proposes an active disturbance rejection control(ADRC)scheme to control the rotor-side,grid-side and DVR-side converters in a wind–DVR integrated network.The performance of the Type-3 WT with DVR topology is evaluated under various test conditions using MATLAB®/Simulink®.These simulation results are also compared with the experimental results for the LVRT capability performed on a WT emulator equipped with a crowbar and direct current(DC)chopper.The simulation results demonstrate a favourable transient and steady-state response of the Type-3 wind turbine quantities defined by the LVRT codes,as well as improved reactive power support under balanced fault conditions.Under the most severe voltage drop of 95%,the stator currents,rotor currents and DC bus voltage are 1.25 pu,1.40 pu and 1.09 UDC,respectively,conforming to the values of the LVRT codes.DVR controlled by the ADRC technique significantly increases the LVRT capabilities of a Type-3 doubly-fed induction generator-based WT under symmetrical voltage dip events.Although setting up ADRC controllers might be challenging,the proposed method has been shown to be extremely effective in reducing all kinds of internal and external disturbances.
文摘As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model.
文摘Nowadays with the improvement in the degree of emphasis on new energy, the wind power system has developed more and more rapidly over the world. Usually the wind plants are located in the remote areas which are far from the load centers. Generally series compensated AC transmission and high voltage DC transmission are made use of to improve the transmission capacity as two main effective ways which can solve the problem of large scale wind power transmission. The paper describes the three kinds of impact varieties and impact mechanisms in the sub-synchronous oscillation phenomena of wind power system based on doubly fed induction generator (DFIG) wind generators. At last, we point out the important problem that should be stressed in the wind power system.
基金Supported in part by the National Natural Science Foundation of China under Grant 51907072in part by the Fundamental Research Funds for the Central Universities under Grant 2021XXJS004。
文摘For doubly-fed induction generator(DFIG)-based wind turbines(WTs),various advanced control schemes have been proposed to achieve the low voltage ride through(LVRT)capability,whose parameters design is significantly reliant on the rotor electromotive force(EMF)of DFIG-based WTs.However,the influence of the rotor current on EMF is usually ignored in existing studies,which cannot fully reflect the transient characteristics of EMF.To tackle with this issue,this study presents a comprehensive and quantitative analysis of EMF during grid faults considering various control modes.First,the DFIG model under grid faults is established.Subsequently,the transient characteristics of EMF are analyzed under different control modes(that is,rotor open-circuit and connected to converter).Furthermore,the EMF transient eigenvolumes(that is,accessorial resistance item,transient decay time constant,and frequency offset)are quantitatively analyzed with the typical parameters of MW-level DFIG-based WT.The analysis results contribute to the design of the LVRT control scheme.Finally,the analysis is validated by the hardware-in-the-loop experiments.
文摘In this paper,an overview of several strategies for fault ride-through(FRT)capability improvement of a doubly-fed induction generator(DFIG)-based wind turbine is presented.Uncertainties and parameter variations have adverse effects on the performance of these strategies.It is desirable to use a control method that is robust to such distur-bances.Auto disturbance rejection control(ADRC)is one of the most common methods for eliminating the effects of disturbances.To improve the performance of the conventional ADRC,a modified ADRC is introduced that is more robust to disturbances and offers better responses.The non-derivability of the fal function used in the conventional ADRC degrades its efficiency,so the modified ADRC uses alternative functions that are derivable at all points,i.e.,the odd trigonometric and hyperbolic functions(arcsinh,arctan,and tanh).To improve the effciency of the proposed ADRC,fuzzy logic and fractional-order functions are used simultaneously.In fuzzy fractional-order ADRC(FFOADRC),all disturbances are evaluated using a nonlinear fractional-order extended state observer(NFESO).The performance of the suggested structure is investigated in MATLAB/Simulink.The simulation results show that during disturbances such as network voltage sag/swell,using the modified ADRCs leads to smaller fluctuations in stator flux amplitude and DC-link voltage,lower variations in DFIG velocity,and lower total harmonic distortion(THD)of the stator current.This demonstrates the superiority over conventional ADRC and a proportional-integral(PI)controller.Also,by chang-ing the crowbar resistance and using the modified ADRCs,the peak values of the waveforms(torque and currents)can be controlled at the moment of fault occurrence with no significant distortion.
文摘This paper presents a new control strategy for the rotor side converter of Doubly-Fed Induction Generator based Wind Turbine systems,under severe voltage dips.The main goal is to fulfill the Low Voltage Ride Through performance,required by modern grid codes.In this respect,the key point is to limit oscillations(particularly on rotor currents)triggered by line faults,so that the system keeps operating with graceful behavior.To this aim,a suitable feedforward-feedback control solution is proposed for the DFIG rotor side.The feedforward part exploits oscillation-free reference trajectories,analytically derived for the system internal dynamics.State feedback,designed accounting for control voltage limits,endows the system with robustness and further tame oscillations during faults.Moreover,improved torque and stator reactive power tracking during faults is achieved,proposing an exact mapping between such quantities and rotor-side currents,which are conventionally used as controlled outputs.Numerical simulations are provided to validate the capability of the proposed approach to effectively cope with harsh faults.
文摘The current paper talks about the variable speed wind turbine generation system (WTGS). So, the WTGS is equipped with a doubly-fed induction generator (DFIG) and two bidirectional converters in the rotor open circuit. A vector control (VC) of the rotor side converter (RSC) offers independent regulation of the stator active and reactive power and the optimal rotational speed tracking in the power maximization operating mode. A VC scheme for the grid-side converter (GSC) allows an independent regulation of the active and reactive power to exchange with the grid and sinusoidal supply currents and keeps the DC-link voltage constant. A fuzzy inference system (FIS) is adopted as an alternative of the conven- tional proportional and integral (PI) controller to reject some uncertainties or disturbance. The performances have been verified using the Matlab/Simulink soft-ware.
文摘The purpose of this paper is to improve the control performance of the variable speed, constant frequency doubly-fed induction generator in the wind turbine generation system by using fuzzy logic controllers. The control of the rotor-side converter is realized by stator flux oriented control, whereas the control of the grid-side converter is performed by a control strategy based on grid voltage orientation to maintain the DC-link voltage stability. An intelligent fuzzy inference system is proposed as an alternative of the conventional proportional and integral (PI) controller to overcome any disturbance, such as fast wind speed variation, short grid voltage fault, parameter variations and so on. Five fuzzy logic controllers are used in the rotor side converter (RSC) for maximum power point tracking (MPPT) algorithm, active and reactive power control loops, and another two fuzzy logic controllers for direct and quadratic rotor currents components control loops. The performances have been tested on 1.5 MW doubly-fed induction generator (DFIG) in a Matlab/Simulink software environment.
基金supported by the State Grid Corporation Headquarters Science and Technology Project(Grant No.5100-202199273A-0-0-00).
文摘Wind power(WP)is considered as one of the main renewable energy sources(RESs)for future low-carbon and high-cost-efficient power system.However,its low inertia characteristic may threaten the system frequ-ency stability of the power system with a high penetration of WP generation.Thus,the capability of WP participating in the system frequency regulation has become a research hotspot.In this paper,the impact of WP on power system frequency stability is initially presented.In addition,various existing control strategies of WP participating in frequency regulation are reviewed from the wind turbine(WT)level to the wind farm(WF)level,and their perfor-mances are compared in terms of operating principles and practical applications.The pros and cons of each control strategy are also discussed.Moreover,the WP combing with energy storage system(ESS)for system frequency regulation is explored.Furthermore,the prospects,future challenges,and solutions of WP participating in power system frequency regulation are summarized.
文摘A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG)models to study the impact of increasing wind integration on system protection.Thispaper is on the experimental validation of a generic electromagnetic transient-type(EMT-type)model of aggregated WTGs or wind parks suitable for transient studies.The phasor domain equivalent of the generic model,suitable for protection tools based on steady-state solvers,is also considered.The model has been validated using two sets of actual relay records for the fault response of two wind parks consisting of Type-III WTGs and connected to115 kV and 230 kV transmission systems.The objective is to show that the generic model can reproduce the actual fault response in simulations,and protection engineers can obtain accurate models of wind parks using fault records.A distinctive characteristic of a WTG is its substantially different negative sequence fault current contribution compared to a synchronous generator.The paper shows that the generic model provides enough options to reproduce the negative sequence behavior and hence is suitable for fault studies involving negative sequence-based protection.
基金This work was partially supported by Natural Science Foundation of China(No.72071100)Guangdong Basic and Applied Basic Research Fund(No.2019A1515111173)Department of Education of Guangdong Province,and Young Talent Program(No.2018KQNCX223).
文摘With the increasing share of wind power,it is expected that wind turbines would provide frequency regulation ancillary service.However,the complex wake effect intensifies the difficulty in controlling wind turbines and evaluating the frequency regulation potential from the wind farm.We propose a novel frequency control scheme for doubly-fed induction generator(DFIG)-based wind turbines,in which the wake effect is considered.The proposed control scheme is developed by incorporating the virtual inertia control and primary frequency control in a holistic way.To facilitate frequency regulation in timevarying operation status,the control gains are adaptively adjusted according to wind turbine operation status in the proposed controller.Besides,different kinds of power reserve control approaches are explicitly investigated.Finally,extensive case studies are conducted and simulation results verify that the frequency behavior is significantly improved via the proposed control scheme.
文摘This paper presents an enhanced control strategy for Wind Energy Conversion System(WECS)using Doubly-Fed Induction Generator(DFIG).A robust Super-Twisting(STW)sliding mode control for variable speed wind turbine is developed to produce the optimal aerodynamic torque and improve the dynamic performance of the WECS.The electromagnetic torque of the DFIG is directly tracked using the proposed control to achieve maximum power extraction.The performance and the effectiveness of the STW control strategy are compared to conventional Sliding Mode(SM)and Proportional-Integral(PI)controllers.The proposed STW algorithm shows interesting features in terms of chattering reduction,finite convergence time and robustness against parameters variations and system disturbances.
文摘The doubly-fed induction generator(DFIG)is considered to provide a low-reactance path in the negative-sequence system and naturally comply with requirements on the negative-sequence reactive current in emerging grid codes.This paper shows otherwise and how the control strategy of converters plays a key role in the formation of the active and reactive current components.After investigating the existing control strategies from the perspective of grid code compliance and showing how they fail in addressing emerging requirements on the negative-sequence reactive current,we propose a new coordinated control strategy that complies with reactive current requirements in grid codes in the positive-and negative-sequence systems.The proposed method fully takes advantage of the current and voltage capacities of both the rotor-side converter(RSC)and grid-side converter(GSC),which enables the grid code compliance of the DFIG under unbalanced three-phase voltages due to asymmetrical faults.The mathematical investigations and proposed strategy are validated with detailed simulation models using the Electric Power Research Institute(EPRI)benchmark system.The derived mathematical expressions provide analytical clarifications on the response of the DFIG in the negative-sequence system from the grid perspective.