期刊文献+
共找到188篇文章
< 1 2 10 >
每页显示 20 50 100
Simulation on DC Current Distribution in AC Power Grid under HVDC Ground-Return-Mode 被引量:1
1
作者 Guihua Mei Yuanzhang Sun Yancun Liu 《Journal of Electromagnetic Analysis and Applications》 2010年第7期418-423,共6页
This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupli... This paper focus on the Modeling and Calculation of DC current distribution in AC power grid induced under HVDC Ground-Return-Mode. Applying complex image method and boundary element method, a new field-circuit coupling model was set up. Based on the calculation result with complex image method, this paper derived the modification factor for induced earth potential from practical measurement, which increased the accuracy of calculation. The modification method is helpful for evaluation on the effect of means used for blocking the dc-bias current in transformer neutral and also useful for the forecast of the DC current distribution when the power grid is in different line connection mode. The DC distribution character in Guangdong power grid is shown and suggestion is proposed that the mitigation of dc-bias should start from those substations whose earth-potential is highest. 展开更多
关键词 HVDC DC-Bias DC DISTRIBUTION ground-return Current SIMULATION
下载PDF
多端直流输电工程大地-金属回线转换策略
2
作者 赵倩 张群 《电气技术》 2024年第3期74-78,共5页
针对国内首个常规多端直流输电系统在不同功率水平进行大地回线至金属回线转换的过程中,金属回线转换开关(MRTB)保护动作,导致开关拒动及大地金属回线转换失败的问题,本文通过对大地金属回线转换过程中的电流回路进行分析,推导大地回线... 针对国内首个常规多端直流输电系统在不同功率水平进行大地回线至金属回线转换的过程中,金属回线转换开关(MRTB)保护动作,导致开关拒动及大地金属回线转换失败的问题,本文通过对大地金属回线转换过程中的电流回路进行分析,推导大地回线与金属回线共存时各个换流站电流的数学表达式,在此基础上分析MRTB拒动原因,并提出改进策略和运行建议,为工程设计和运行维护提供参考。最后,通过仿真证明了本文分析结论的正确性,表明所提改进策略具备工程应用推广价值。 展开更多
关键词 多端直流 大地回线 金属回线 转换开关保护 回路分析
下载PDF
高速铁路牵引变电所亭地网回流动态验收标准的修改方案研究
3
作者 陈劲草 《铁路工程技术与经济》 2024年第1期60-65,70,共7页
本文介绍了现行的高速铁路牵引所回流指标,介绍了高速铁路牵引供电回流系统的组成,计算了牵引供电回流各支路的分流系数,分析了影响回流分配的各种因素。结合直接供电加回流和AT供电方式的地回流特征与差异,指出根据方差偏离均值的程度... 本文介绍了现行的高速铁路牵引所回流指标,介绍了高速铁路牵引供电回流系统的组成,计算了牵引供电回流各支路的分流系数,分析了影响回流分配的各种因素。结合直接供电加回流和AT供电方式的地回流特征与差异,指出根据方差偏离均值的程度进行地回流指标判定和质量分级标准存在的缺陷。最后,综合全路高速铁路牵引供电接地系统和地网回流的情况,提出高速铁路牵引变电所地网回流动态验收标准的修改方案建议。 展开更多
关键词 高速铁路 牵引变电所 地网 回流 验收标准
下载PDF
基于车体接地电流的故障列车精准识别方法
4
作者 郭世成 刘永生 +5 位作者 吴晶 侯炜 江鑫 张向亮 陈恺 石祥建 《中国电力》 CSCD 北大核心 2024年第7期143-150,共8页
针对专用回流轨直流牵引供电系统发生正极与车体短路故障时,故障列车不能被精准识别的问题,首先给出了双边供电牵引系统等值模型,其次分析了故障列车和正常列车的车体接地电流特征差异,最后提出了一种基于车体接地电流的故障列车精准识... 针对专用回流轨直流牵引供电系统发生正极与车体短路故障时,故障列车不能被精准识别的问题,首先给出了双边供电牵引系统等值模型,其次分析了故障列车和正常列车的车体接地电流特征差异,最后提出了一种基于车体接地电流的故障列车精准识别方法。所提方法采用列车的车体接地电流幅值和方向作为故障识别判据,当其幅值小于整定值时判断列车正常,当大于等于整定值时继而采用其方向进行判断,电流为正方向的列车被判为故障车,电流为反方向的列车被判为正常车。该方法原理简单,实现方便,实用性强,采用双重判据能有效避免误判,可靠性高。通过Matlab仿真和现场试验录波验证了方法的可行性和有效性。 展开更多
关键词 单轨交通 专用回流轨 直流牵引供电系统 车体接地电流 故障列车 精准识别
下载PDF
Triple-Band L-Shaped Monopole Antenna with Defected Ground Plane for WLAN and WiMAX Application
5
作者 Yih-Chien Chen Min-Zhe Weng 《Journal of Electronic Science and Technology》 CAS CSCD 2015年第2期135-138,共4页
This paper presents the simulation and measured results of a triple-band L-shaped monopole antenna with defected ground plane for applications in wireless local area networks(WLANs) and worldwide interoperability fo... This paper presents the simulation and measured results of a triple-band L-shaped monopole antenna with defected ground plane for applications in wireless local area networks(WLANs) and worldwide interoperability for microwave access(WiMAX) bands.The triple-band L-shaped monopole antenna with defected ground plane was fabricated on a FR4 substrate. The lower band is associated with the shorted parasitic strip in the protruding stub of the ground plane; the middle band is expected to be controlled by the longer strip of L-shaped monopole in the front side,while the higher band is associated with the short strip of L-shaped monopole in the front side. The proposed antenna has a good agreement between the measured and the simulation results. It has a 10 d B return loss with the bandwidth of 250 MHz(2270 MHz to 2520MHz) in the lower band, 600 MHz(3320 MHz to 3,920MHz) in the middle band, and 1110 MHz(5030 MHz to6140 MHz) in the higher band. The proposed antenna covers the ISM(industrial, scientific and medical),HIPERLAN(high performance radio local area network), UNII(unlicensed national information infrastructure), and WiM AX bands. 展开更多
关键词 antenna Triple bandwidth shaped infrastructure triple bands ground microwave return
下载PDF
城市轨道交通专用轨回流系统保护设计分析
6
作者 贾国兴 《智能建筑电气技术》 2024年第2期21-24,共4页
随着《城市轨道交通工程项目规范》GB55033-2022的实施,将杂散电流防护设计提到了新的高度,并提高了杂散电流的泄漏标准,专用轨回流系统将是轨道交通工程杂散电流防护设计的有效解决方案。本文以宁波轨道交通项目设计为例,对专用轨回流... 随着《城市轨道交通工程项目规范》GB55033-2022的实施,将杂散电流防护设计提到了新的高度,并提高了杂散电流的泄漏标准,专用轨回流系统将是轨道交通工程杂散电流防护设计的有效解决方案。本文以宁波轨道交通项目设计为例,对专用轨回流系统的保护设置进行分析,本方案特有的保护设施包括专用轨接地装置和地负单向导通装置,提出将专用轨接地装置与地负单向导通装置合并设置建议。 展开更多
关键词 轨道交通 专用轨接地装置 地负单向导通装置 合并设置
下载PDF
Evaluation of Horizontal Electric Field Under Different Lightning Current Models by Perfect Ground Assumption
7
作者 LIANG Jianfeng LI Yanming 《高电压技术》 EI CAS CSCD 北大核心 2012年第8期2112-2116,共5页
关键词 局部放电 射频信号 放电量 高电压技术
下载PDF
乡村振兴背景下大学生返乡创业影响因素研究 被引量:1
8
作者 张之剑 范翠英 《武汉理工大学学报(信息与管理工程版)》 CAS 2023年第6期949-954,982,共7页
为激发大学生返乡创业动力,助力乡村振兴,以返乡创业的大学生为研究对象,探讨大学生返乡创业的影响因素。通过扎根理论,对不同高校与地区的大学生返乡创业者进行访谈调研,构建了大学生返乡创业影响因素“钻石模型”,大学生返乡创业者受... 为激发大学生返乡创业动力,助力乡村振兴,以返乡创业的大学生为研究对象,探讨大学生返乡创业的影响因素。通过扎根理论,对不同高校与地区的大学生返乡创业者进行访谈调研,构建了大学生返乡创业影响因素“钻石模型”,大学生返乡创业者受心理资本、创业项目实现、创业教育资本、创业社会资本4个因素影响。研究表明,各因素间有着主次关系、相互促进,具有时代与地区差异性。社会、高校、家庭加强创新创业综合素质与技能的教育,给予学生创业政策指导,提供多方面创业支持将有助于推进大学生返乡创业。 展开更多
关键词 创业管理 钻石模型 扎根理论 返乡创业 乡村振兴
下载PDF
Feasibility of using polypropylene ground cover upon consideration of long-term responses of sweet cherry nutrition and profitability 被引量:3
9
作者 Xinhua Yin Clark F. Seavert 《Agricultural Sciences》 2012年第4期594-601,共8页
The impacts of synthetic polypropylene ground cover in the row area of sweet cherry (Prunus avium L.) trees (‘Regina’/’Gisela 6’) on soil nutrient availability, tree mineral nutrition and productivity, and economi... The impacts of synthetic polypropylene ground cover in the row area of sweet cherry (Prunus avium L.) trees (‘Regina’/’Gisela 6’) on soil nutrient availability, tree mineral nutrition and productivity, and economic returns were investigated on a Van Horn fine sandy loam soil at Hood River OR, from 2000 to 2007. Treatments included 2.44-m wide synthetic fabric ground cover made of black, woven poly-propylene over the row area of cherry trees (woven fabric), and no ground cover but with herbicide applications in the row area with the same width as the polypropylene ground cover (herbicide strip) – standard industry practice. This article reports the plant nutrition and soil fertility results of 2006 and 2007 and profitability and feasibility results of 2000 to 2007. Tree leaf nitrogen (N) concentrations were significantly higher with 9 to 14% increases using woven fabric compared with herbicide strip in 2006 and 2007. However, leaf sulfur (S) concentrations were significantly lowered with woven fabric in the two seasons. Woven fabric resulted in fruit with comparable quality and possible greater storability under enhanced fruit yields than herbicide strip in both years. Woven fabric was more profitable than herbicide strip based on an additional net present value of $2,606 ha-1 by the end of this study. Woven fabric had annual gross returns greater than annual costs in the fourth year after planting by $8,181 ha-1 relative to herbicide strip, and had cumulative net returns greater than total costs of all previous years in the sixth year after planting by $17,796 ha-1 over herbicide strip. However, to establish a sweet cherry orchard with woven fabric, the grower would spend an additional $4,332 ha-1 over herbicide strip. In conclusion, woven fabric is a profitable and sustainable in-row ground management alternative to herbicide strip for orchards from a long-term perspective. 展开更多
关键词 POLYPROPYLENE ground Cover Sweet CHERRY Leaf NUTRITION Fruit STORABILITY ANNUAL Gross returns ANNUAL Cost ANNUAL NET returns Cumulative NET returns Present Value
下载PDF
计轴室外干扰故障的分析与解决方案 被引量:2
10
作者 田文礼 马学霞 谢志明 《铁路通信信号工程技术》 2023年第3期72-76,共5页
杭州地铁1号线三期信号系统在动车调试和运营初期出现计轴红光带故障,经示波器监测计轴磁头板,确定故障原因为外界干扰。介绍计轴的工作原理,重点分析故障产生的原因,详细介绍采取的对应措施。测试及实际运营表现证明车辆增加牵引逆变... 杭州地铁1号线三期信号系统在动车调试和运营初期出现计轴红光带故障,经示波器监测计轴磁头板,确定故障原因为外界干扰。介绍计轴的工作原理,重点分析故障产生的原因,详细介绍采取的对应措施。测试及实际运营表现证明车辆增加牵引逆变器与制动电阻双端屏蔽线、轨旁加装均流线可有效降低红光带故障率,可作为其他线路类似故障处理参考方案。 展开更多
关键词 计轴故障 电磁干扰 屏蔽接地 牵引回流
下载PDF
基于雷电定位系统的雷电多回击地闪参数统计及影响因素分析
11
作者 杨雷 韩永霞 +6 位作者 廖志铭 李谦 赵晓凤 李志峰 黄健宁 张杰 刘柏炫 《广东电力》 2023年第7期115-123,共9页
根据2010—2021年广东省雷电定位系统(lightning location system,LLS)数据,以不同定位站数的筛选方式对多回击地闪参数进行统计,发现随着选取的定位站数增加,多回击地闪的占比、雷电流幅值和时间间隔增加,由此指出:开展多回击地闪次数... 根据2010—2021年广东省雷电定位系统(lightning location system,LLS)数据,以不同定位站数的筛选方式对多回击地闪参数进行统计,发现随着选取的定位站数增加,多回击地闪的占比、雷电流幅值和时间间隔增加,由此指出:开展多回击地闪次数及占比统计时应选取定位站数S≥2,避免大部分小雷被忽略;开展雷电流幅值统计时应选取定位站数S≥3,确保雷电流幅值精度。对比分析人工引雷时LLS测量的雷电流幅值差异,发现雷电流幅值越大,LLS中能监测到雷电流的定位站数越多,此时LLS测量的雷电流幅值与人工引雷测量结果的偏差越小。选取定位站数S≥3,统计分析多回击地闪中首次回击雷电流幅值与后续回击的关系及其变化趋势,发现首次至后续回击雷电流幅值中值依次递减、回击时间间隔依次递增,但随着回击次数的增加,所有后续回击的雷电流幅值大于首次回击的概率呈现先增大后略减小的趋势,由此提出后续回击雷电流幅值大于首次回击雷电流幅值的概率计算公式。 展开更多
关键词 多回击地闪 雷电定位系统 人工引雷 定位站数 回击次数 雷电流峰值 时间间隔
下载PDF
市域列车接地回流动态变化规律分析与优化
12
作者 石慧 《电气工程学报》 CSCD 2023年第3期81-89,共9页
市域列车通过车体-轮对-钢轨形成接地回流通道,过大的接地回流会造成轴承电腐蚀、碳刷的异常磨耗等问题,严重威胁动车的安全运行。在Matlab/Simulink中建立了市域列车在供电区间内行驶时接地回流动态过程仿真模型,并结合现场测试数据验... 市域列车通过车体-轮对-钢轨形成接地回流通道,过大的接地回流会造成轴承电腐蚀、碳刷的异常磨耗等问题,严重威胁动车的安全运行。在Matlab/Simulink中建立了市域列车在供电区间内行驶时接地回流动态过程仿真模型,并结合现场测试数据验证了模型的准确性,探明了市域列车在供电区间内运行时接地电流的变化趋势。从接地电流热效应出发,提出市域列车接地电流的“等效值”的概念。从工作接地方式与保护接地方式两个方面出发,探究接地回流的影响因素。根据接地电流的等效值,提出市域列车接地系统的优化方案,仿真结果表明,优化后保护接地电流等效值由53 A下降到17 A,下降幅度达到67%,接地回流分布较为均匀,车体电位也控制在安全的范围内,为设计更优良的接地方案提供了理论基础。 展开更多
关键词 市域列车 接地回流 接地系统 保护接地 工作接地 仿真模型
下载PDF
110 kV电缆单端接地系统回流线加装的仿真研究 被引量:1
13
作者 李崔延 侯赞 《电力勘测设计》 2023年第5期24-27,共4页
为指导高压电缆工程设计中回流线的加装,利用ATPDraw仿真软件,按照不同的短路电流水平和电缆长度范围,对单端接地系统方式的电缆线路进行建模。分别建立站联电缆、纯电缆外电源线路及架空电缆混合线路的仿真模型,重点分析单相接地故障... 为指导高压电缆工程设计中回流线的加装,利用ATPDraw仿真软件,按照不同的短路电流水平和电缆长度范围,对单端接地系统方式的电缆线路进行建模。分别建立站联电缆、纯电缆外电源线路及架空电缆混合线路的仿真模型,重点分析单相接地故障时回流线对金属护层感应过电压的影响,以电缆线路类型、长度为指标给出是否敷设回流线的指导意见。 展开更多
关键词 高压电缆 回流线 ATPDRAW 单相接地 感应电压
下载PDF
基于雷电定位系统和实测的多回击地闪雷电流参数及模型分析
14
作者 赵晓凤 杨雷 +5 位作者 李谦 廖志铭 李昭廷 黄健宁 杨贤 韩永霞 《广东电力》 2023年第8期97-103,共7页
多回击地闪可能造成同一输电线路连续遭受多次雷电冲击,进而引起线路重合闸失败,以及变电站内断路器和避雷器等设备事故。传统以单次雷击设计线路和变电站雷电防护的方法已不足以对现有输电线路和变电站进行很好的防护。为此,依据广东省... 多回击地闪可能造成同一输电线路连续遭受多次雷电冲击,进而引起线路重合闸失败,以及变电站内断路器和避雷器等设备事故。传统以单次雷击设计线路和变电站雷电防护的方法已不足以对现有输电线路和变电站进行很好的防护。为此,依据广东省内12年雷电定位系统数据及人工引雷数据,研究多回击地闪雷电流参数及模型,为线路和变电站的雷电防护提供基础参数和模型。广东地区12年内雷电定位数据统计分析表明:多回击地闪占比为52.58%,而负地闪占多回击地闪的96.84%;正负极性多回击地闪平均频次为2.2和4.1次,时间间隔的平均值分别为140 ms和103 ms;对此提出负极性雷电流幅值概率分布公式。最后,结合人工引雷试验的后续雷击雷电流波形参数及拟合函数、IEEE和GB 50057—2010标准等推荐的首次回击的波形参数,提出可以应用于防雷设计的多回击地闪雷电流参数及模型。 展开更多
关键词 多回击地闪 雷电定位系统 人工引雷 雷电流参数 雷电流模型
下载PDF
某纪念馆空调末端形式分析
15
作者 张萍 《制冷与空调》 2023年第2期68-72,共5页
为呈现扬州某纪念馆建筑本体效果、隐藏空调风口,采用2种空调末端形式:地板嵌入式空调器和风机盘管机组暗藏土建空腔内侧送风。对比分析地板嵌入式空调器与地板送风系统,对冬季幕墙内表面进行防结露计算,对风机盘管机组侧送风系统进行... 为呈现扬州某纪念馆建筑本体效果、隐藏空调风口,采用2种空调末端形式:地板嵌入式空调器和风机盘管机组暗藏土建空腔内侧送风。对比分析地板嵌入式空调器与地板送风系统,对冬季幕墙内表面进行防结露计算,对风机盘管机组侧送风系统进行气流组织模拟计算,结果显示:纪念馆幕墙内表面温度≥11.2℃,大于室内空气露点(4.1℃),没有结露风险;采用侧送风空调形式,人员活动区域夏季室内温度约25℃,冬季约22℃,这2种空调末端形式既能满足人员舒适性需求又能巧妙隐藏空调设备。 展开更多
关键词 空调 纪念馆 气流组织 地板嵌入式空调器 侧送侧回
下载PDF
葛南直流输电系统中大地回线和金属回线转换的研究 被引量:28
16
作者 严宇 朱伟江 +3 位作者 刘皓 陈刚 王轶禹 邹精 《电网技术》 EI CSCD 北大核心 2005年第21期5-8,共4页
以葛南直流输电系统为例,将顺控逻辑及动作整定值作为切入点,利用ABB公司的故障录波软件,分析了大地回线和金属回线转换过程中因非转换极极线路电流过低所造成的切换失败率高的问题,并提出更改控制系统中关于钳制电位点顺控逻辑的解决方... 以葛南直流输电系统为例,将顺控逻辑及动作整定值作为切入点,利用ABB公司的故障录波软件,分析了大地回线和金属回线转换过程中因非转换极极线路电流过低所造成的切换失败率高的问题,并提出更改控制系统中关于钳制电位点顺控逻辑的解决方法,采取该方法后上述问题在调试和实际运行中未再次出现。 展开更多
关键词 电力系统 直流输电 大地回线 金属回线 大地回线转换开关(GRTS) 金属回线转换开关(MRTB)
下载PDF
高压直流输电单极大地方式运行时地表电位分布规律 被引量:42
17
作者 郝治国 余洋 +4 位作者 张保会 程临燕 曹瑞峰 丁茂生 张军 《电力自动化设备》 EI CSCD 北大核心 2009年第6期10-14,共5页
采用有限元方法分析了直流单极大地方式运行时大范围的地表电位分布特征,并通过ANSYS软件计算了浅层和深层2种土壤结构模型下的地电位分布;同时考虑了有变电所出线、不同变电所接地电阻、江河以及湖泊等多种情况下对地电位分布的影响。... 采用有限元方法分析了直流单极大地方式运行时大范围的地表电位分布特征,并通过ANSYS软件计算了浅层和深层2种土壤结构模型下的地电位分布;同时考虑了有变电所出线、不同变电所接地电阻、江河以及湖泊等多种情况下对地电位分布的影响。研究结果表明:土壤结构对地表电位分布影响较大,采用土壤深层模型时计算结果更为准确;变电所架空出线距离直接接地极越近、线路越长、线路回数越少,其两端的电位差越大;河流对地表电位影响较小,湖泊边缘处对地表电位影响较大。 展开更多
关键词 高压直流输电 有限元方法 ANSYS 单极大地方式 地表电位 分布规律
下载PDF
HVDC地中直流对交流系统的影响及规律分析 被引量:38
18
作者 曾嵘 张波 +4 位作者 赵杰 蔡宗远 王琦 何金良 张铮 《高电压技术》 EI CAS CSCD 北大核心 2009年第3期678-682,共5页
直流输电系统在系统调试或故障情况下会处于单极大地回路运行方式,这时地中直流会对交流系统的正常运行带来不利影响。为此全面总结了我国龙政、天广、三广直流输电线路在调试与运行过程中对附近交流电网运行带来的噪声、谐波、振动等... 直流输电系统在系统调试或故障情况下会处于单极大地回路运行方式,这时地中直流会对交流系统的正常运行带来不利影响。为此全面总结了我国龙政、天广、三广直流输电线路在调试与运行过程中对附近交流电网运行带来的噪声、谐波、振动等不利影响;通过贵广调试现场实验及对实测数据的详细分析,归纳得到变压器中性点直流、谐波、噪声等与入地直流之间的关系规律;通过建立理论模型,对于地中直流的分布特性进行了分析,并以春城变电站为例就中性点直流电流进行了计算。计算结果验证了所提理论模型和计算方法的有效性。 展开更多
关键词 高压直流 直流接地极 中性点直流 大地回路 可听噪声 谐波电压
下载PDF
宁东直流大地回线转金属回线转换失败原因分析与改进建议 被引量:8
19
作者 林少伯 王明新 +4 位作者 王华伟 李新年 吴娅妮 杨鹏 庞广恒 《电力系统保护与控制》 EI CSCD 北大核心 2015年第24期129-134,共6页
在我国高压直流输电投入实际运行以来,在大地回线转金属回线过程中,多次发生由于金属回线转换开关(MRTB)并联的吸能避雷器损坏而导致转换失败的事件,迫切需要精确反应开关动作机理的研究手段。通过对宁东直流输电系统现场大地回线转金... 在我国高压直流输电投入实际运行以来,在大地回线转金属回线过程中,多次发生由于金属回线转换开关(MRTB)并联的吸能避雷器损坏而导致转换失败的事件,迫切需要精确反应开关动作机理的研究手段。通过对宁东直流输电系统现场大地回线转金属回线转换成功的与失败的录波波形对比分析,得出转换失败前后的系统电气特征。采用宁东直流实际的主回路设备参数和控制保护功能,建立起以直流电磁暂态程序(EMTDC)为基础的详细模型,再现了开关转换和故障过程的暂态现象。不仅验证避雷器由于四柱并联,长期运行操作使每个柱特性变化不一致,较小阻抗单柱承受较大的能量而损坏,而且,通过对转换失败之后逆变站金属回线接地保护动作闭锁直流系统事件进行分析,得出由于逆变站金属回线接地保护软件策略缺陷,导致保护动作闭锁直流系统。根据分析结果,对宁东直流大地转金属回线过程提出改进建议,同时对后续直流工程的MRTB并联避雷器的成套设计提出建议。 展开更多
关键词 大地回线 金属回线 大地回路转换开关 金属回线转换开关 金属回线接地保护 避雷器
下载PDF
中国内陆高原地闪特征的统计分析 被引量:66
20
作者 郄秀书 余晔 +1 位作者 王怀斌 张翠华 《高原气象》 CSCD 北大核心 2001年第4期395-401,共7页
利用微秒级时间分辨率的宽带慢天线电场变化仪首次在中国内陆高原地区对雷暴过程中的正、负地闪特征进行了测量和系统分析 ,发现每次雷暴过程中正闪的比例有随总闪频数增大而减少的趋势 ,弱雷暴过程更有利于正地闪的产生。平均来讲 ,正... 利用微秒级时间分辨率的宽带慢天线电场变化仪首次在中国内陆高原地区对雷暴过程中的正、负地闪特征进行了测量和系统分析 ,发现每次雷暴过程中正闪的比例有随总闪频数增大而减少的趋势 ,弱雷暴过程更有利于正地闪的产生。平均来讲 ,正地闪占闪电总数的 16 % ,介于美国夏季雷暴和日本冬季雷暴之间。负地闪闪击间隔的算术平均值和几何平均值分别为 6 4.3ms和 46 .6ms。 5 4%的负地闪有至少一次继后回击强度大于首次回击 ,而且有 2 0 %的继后回击其强度大于首次回击强度。继后回击强度与首次回击强度的比例几何平均值为 0 .46 ,算术平均值为 0 .70 ,平均回击数为 3.76 ,39.8%为单次回击地闪。正地闪的多次回击只占 13.0 % ,且闪击之间的时间间隔也较大 ,算术平均值为 91.7ms。 展开更多
关键词 中国 内陆高原 雷暴 正地闪 负地闪 回击强度
下载PDF
上一页 1 2 10 下一页 到第
使用帮助 返回顶部